Telecom Networking Solutions
S9500-30XS
DISAGGREGATED
CELL SITE GATEWAY ROUTER
The UfiSpace S9500-30XS is the first open design cell site gateway router that enables service providers
to deploy Open and Disaggregated Transport Network (ODTN) services. The S9500-30XS cell site gateway
router conforms to the Open Compute Project (OCP) Cell Site Gateway Router specifications.
With temperature-hardened, high port density, high-throughput, and small form factor features, the
S9500-30XS gateway router is designed for both outdoor and indoor deployments, supporting 4G and 5G
base stations with full IEEE 1588v2 and SyncE timing functions and providing backhaul uplinks at 25GbE
and 100GbE.
The UfiSpace S9500-30XS enables carrier service providers to deploy disaggregated open network
infrastructure to lower costs and rapidly scale existing services for edge computing, mobile backhaul, and
broadband access applications.
KEY FEATURES
■ Supports full SyncE and IEEE 1558v2 (T-GM, T-BC, T-TC, and T-TSC)
■ Integrated Stratum 3E OCXO with optional hold over performances
■ Integrated GNSS receiver with passive or active antenna support
■ Rich timing interfaces: ToD, BITS, 1PPS and 10MHz
KEY BENEFITS
■ Supports 100M/1G for legacy and 10G/25G for 5G
■ COCP Accepted and TIP Compliant. ■ Supports backhaul data rates up to 100 Gbps
■ Temperature hardened router meeting TP76200 requirements designed for
operation in GR‐3108 Class 2 OSP (Outside Plant) cabinets (NEBS Level 3) for cell ■ 3GB deep buffering and Intel® 1.5 GHz quad core CPU for network
site backhauls. operation
■ Ultra-low forwarding latency, high precision frequency and phase timing ■ Individual BMC allowing automatic and remote operations for
synchronization supporting the inputs and outputs needed to accommodate the
evolving requirements of 5G. monitoring and managing platform health status
■ High port density applications with versatile 1/10/25/100 Gbps through optimum ■ 1 RU small form factor with 300mm depth
heat dissipation and electromagnetic shielding.
■ Hot swappable power supplies with 1+1 redundancy support
■ WAN and long haul markets, designed for long-reach, up to 120 km applications
with MACSec feature.
■ Hot swappable fan modules with 4+1 redundancy support
■ Open NOS applications for highly reliable composable networks.
SPECIFICATIONS
PHYSICAL ENVIRONMENTAL
2 x 100GE QSFP28 ports Power Supply AC input: 100 ~ 240V, 6 ~ 3A, 50 ~ 60Hz
8 x 25GE SFP28 ports DC input: -36 ~ -75V, 16 ~ 8A
Max power: 400 Watts
20 x 10GE SFP+ ports
1 x RJ45 + Micro USB console/management ports Max. Operating Operating temperature: -40°C to 65°C (-40°F to 149°F)
1 x 1000 Base-T Ethernet port for OOB Specs. Operating humidity: 5% to 93% (RH), noncondensing
1 x USB 2.0 Type-A general purpose port
Max. Non-Operating Storage temperature: -40°C to 70°C (-40°F to 158°F)
Processor Intel Broadwell-DE D1519 4 Cores @1.5GHz Specs. Storage humidity: 5% to 85% (RH), non-condensing
Memory 2 x 8GB DDR4 SO-DIMM with ECC
Storage 1 x 128GB M.2 SSD
PERFORMANCE
ASIC Broadcom Qumran-AX BCM88470
Timing 1 x GNSS input Switching Capacity 300 Gbps
Interfaces 1 x 1PPS input/output
1 x 10MHz input/output
1 x ToD input/output REGULATORY COMPLIANCE
1 x BITS input
Safety NEBS Level 3 EMC NEBS Level 3
Hardware ITU-T Synchronous Ethernet (SyncE) FCC Part 15, Subpart B, Class A
UL 62368-1
Timing IEEE 1588v2 (Default, G.8265.1, G.8275.1, G.8275.2, EN55032, Class A
IEC/EN 60950-1
Capabilities T-TC, T-BC/OC, T-GM) EN300 386
IEC/EN 62368-1
EN55024
Chassis 1 RU, 440 x 302 x 43.5 mm BSMI CNS 14336-1 EN301 489-1
(WxDxH) EN301 489-19
or 17.32” x 11.89“ x 1.713"
Net weight: 6.6 kg. or 14.55 lbs. EN303413
BSMI (CNS 13438), Class A
Redundancy Hot swappable, 1+1 redundant PSU VCCI-CISPR 32:2016, Class A
Hot swappable, 4+1 redundant fans VCCI 32-1:2016, Class A
Specifica�ons are subject to change without no�ce.
S9500-30XS Front and Back Views
S9500-30XS
SUPPORTED ACCESSORIES
Transceivers
100GBASE SR4 QSFP28, 100GBASE CWDM4 QSFP28, 100GBASE LR4 QSFP28,
100GBASE ER4 QSFP28, 25GBASE SR SFP28, 25GBASE LR SFP28, 10GBASE SR SFP+,
10GBASE LR SFP+, 10GBASE ER SFP+, 10GBASE ZR SFP+, 1GBASE-T, 1GBASE SX SFP,
1GBASE LX SFP, 1GBASE EX SFP, 1GBASE ZX SFP
Cable Types
50 ohms SMA coaxial cable with 1/4-36UNS-2B connector for GNSS, 1PPS, and 10MHz
Shield cable with RJ45 for ToD
Shield cable with RJ48 for BITS
Telecom Power Supply Types
Networking PSU-401-DISB, 400W DC PSU, intake air flow
PSU-401-AISB, 400W AC PSU, intake air flow
Solutions Fan Types
FAN-402825-HD, exhaust air flow
© 2020 All other marks that may be men�oned herein are the property of their respec�ve owners. References in this publica�on to branded products, programs, or services do not imply that they will be made available in
all countries. Product specifica�ons provided are sample specifica�ons and do not cons�tute a warranty. Actual specifica�ons for unique part numbers may vary. Please visit our website for addi�onal informa�on on product
specifica�ons. Pictures shown may vary from actual products.