Installing Cgtech Products
Installing Cgtech Products
The term "VERICUT", used the following installation instruction sections, unless
specifically stated otherwise, refers to both VERICUT Verification and VERICUT
Composite software. Installing and configuring VERICUT is simple, typically requiring
only a few minutes for most installations.
Overview
A VERICUT software installation involves adding the VERICUT product files to your
computer and setting-up licensing.
Files are added to your computer with a typical "wizard" installation process, where you
run an installer program which prompts you through various options in a sequence of
screens, and ultimately adds the VERICUT software product files to your computer.
VERICUT is a licensed program, meaning that it requires authorization from another
software program (the license server) before it can run. When the VERICUT software
starts, it communicates with the license server program, gets authorization to continue,
and then displays the VERICUT software on your computer, ready to use.
1
Installing CGTech Products
Terminology
It is important you understand 3 terms frequently used throughout the installation
instructions.
License Server Program — The program providing licenses for VERICUT.
VERICUT requires a license, thus the License Server Program must be running for
VERICUT to operate. VERICUT uses the Sentinel RMS license server program from
SafeNet. The license server program and VERICUT communicate using network
protocols. Only one Sentinel RMS license server program may run on a computer.
License Server Computer — The computer running the license server program. It
may be the same computer running VERICUT, such as in a simple single computer
installation. For this type of installation the License Server Computer must be a
Windows computer.
The License Server Computer may only be a computer supplying licenses to other
computers running VERICUT in your company’s network. In this case the License
Server computer can be either a Windows computer or a UNIX computer.
Client Computer — The computer that runs the VERICUT software. Client
Computers can only be Windows computers.
Where you decide to put VERICUT product files depends on whether you have a simple
single computer installation, or multiple networked computers. However, the License
Server Computer and License Server Program are configured exactly the same for any
type of installation, from a simple single computer to multiple networked computers with
Windows Client Computers on a wide area network.
NOTE: The VERICUT Verification software and VERICUT Composite Software is
only supported on Windows Client computers.
You do not need to request a license for a major release (such as 6.0, 6.2, 7.0, 7.1 etc) if
you are currently running VERICUT software and are current on software maintenance.
CGTech automatically emails updated license keys to existing customers with current
software maintenance when a new VERICUT software major version is shipped. CGTech
emails license keys to your company's primary VERICUT contact shortly before shipping
VERICUT CDs.
You also do not need to request a license if you have already received one specific for
this major version and are installing a point release, such as 7.0.1.
You must request a license for a new installation, to add new modules to an existing
installation, to change license server computers, or to update to a new major version after
renewing expired maintenance. If this is a new installation or if you are changing to a
new license server computer, you need to tell CGTech the HOST ID of the license server
computer. The HOST ID of your license server computer is determined during the
installation steps below.
2
Installing CGTech Products
Installation Steps
NOTES:
1. For best results follow the outline below in sequence. Each subsequent step relies
on completion and/or information from the previous one.
2. If errors occur, visit the VERICUT Users’ Forum or contact CGTech technical
support via our website, just click on the support link.
2. Check VERICUT System Requirements and make sure that your system meets them.
3. If this is a new installation or you do not already have a VERICUT 7.1 license,
determine your license server computer HOST ID and request a VERICUT license.
6. Test VERICUT to verify correct operation and licensing on the License Server
Computer: Windows
7. If you have other computers that will access the same license server, configure and
test VERICUT client computers, Windows
3
Installing CGTech Products
4
Installing CGTech Products
• To install the CAD Model Interface modules, go to Installing the Model Interface
Modules.
• Windows Start Menu License Administration Choices
• Determine Your License Server's Host ID, Windows or UNIX
• Check Network Configuration, Windows or UNIX
• Mount a UNIX CD
• Change License Servers, Windows or UNIX
• Update an Existing License, Windows or UNIX
• Stop and Remove a License Server, Windows or UNIX
• Starting a Temporary License Server, Windows or UNIX
• Uninstall an old version of VERICUT software
• Installing Microsoft C++ redistributable run-time libraries for XP64 or Vista64
• Configure Redundant License Servers on Windows or UNIX.
5
Installing CGTech Products
There are several different ways to configure your VERICUT software installation.
Following are three common configurations: a simple single computer or stand-alone
installation and two different multiple-computer installations.
6
Installing CGTech Products
• The license server program supplies licenses to the VERICUT software running
on multiple computers on the network.
• The VERICUT software is installed on one computer's disk. The disk is mounted
or mapped on all computers using the same path.
• The license server program is running on one of the computers.
• The license server program supplies licenses to the VERICUT software running
on multiple computers on the network.
NOTE: If the license server program is running on a UNIX computer,
VERICUT will not be installed on the License Server Computer.
There is always a license server computer in all three types of installations. The license
server computer can be any computer on the network capable of running the license
server program. The license server is installed and configured in exactly the same way
regardless of the type of installation. The only difference between these installations is
the client computer configuration.
In the case of the "Single Stand-alone Computer" installation, the license server
program and the VERICUT software both run on the same computer. The client
computer and the license server computer are the same computer. However, it is
important to note that the VERICUT software and the license server program must still
communicate with each other using network protocols, even thought they are on the same
physical computer.
The "Multiple Computer Installation" consists of one computer configured the same as
the single stand-alone computer described above, but with additional VERICUT software
installations on other computers on the network, the Client Computers. These client
computers do not run the license server program, but rather communicate with the license
server computer and request licenses from the license server program over the network.
The communication protocol is TCP/IP.
7
Installing CGTech Products
Finally, the "Multiple Computer Network Installation" is similar to the single stand-
alone configuration in that there is only one copy of the VERICUT software installed. In
this case the VERICUT software is installed on a disk that is network mounted or
mapped on one or more client computers. Generally the license server computer is the
computer with the disk physically attached, but this is not necessary. The client
computers do not have the VERICUT software installed on a local disk. Instead they
access the VERICUT software on a network mounted or mapped disk. The disk where
the VERICUT software is installed must be mounted or mapped to exactly same path on
all the computers by the site's system administrator.
Thus if the VERICUT software is installed on H:\CGTECH in a Windows environment,
then all computers must map the disk with the same letter and path.
The Multiple Computer Network Installation is the simplest installation to maintain
for a medium to large corporate network environment since there is only one license
server computer and one installation of the VERICUT software shared by all users.
However it does require some custom configuration on each client computer (adding a
start menu or desktop shortcut) in order to give users on the client computers easy access
to the VERICUT software. This work is generally done by the systems administrator.
Next installation task: Check System Requirements
8
Installing CGTech Products
General Requirements
9
Installing CGTech Products
http://download.vericut.net/downloads/redistributables.zip
10
Installing CGTech Products
UNIX Requirements
UNIX minimum operating system versions for VERICUT’s license server are:
HP HP-UX 11.11
IBM AIX 5.2
Sun Solaris 10 (SPARC processors only)
To install the license server program only choose "Custom" on the Type of Installation
install screen. Then on the Choose VERICUT Components install window, check only
the "License" choice.
11
Installing CGTech Products
License overview
VERICUT software is licensed by a license server program, running on the license
server computer. Any computer capable of running VERICUT software can be used as
the license server computer. When the license server program starts it reads encrypted
license keys from a file and compares them with the HOST ID of the computer it is
running on. If the encrypted keys match the HOST ID, the license keys are added to the
license server. Once the license server is fully up and available it contains a pool of
VERICUT software licenses. When the VERICUT software runs it obtains licenses from
the license server.
NOTE: If this is a new installation or you are changing license server computers you
must first Determine the HOST ID of the new license server computer, then request
license keys via CGTech's website (see below).
Determining the HOST ID of the license server computer
Windows
1. Insert the VERICUT CD into the license server computer's CD-ROM drive.
2. Cancel from the install screen (if it appears).
3. Double-click on the 'hostinfo.bat' file located in the CD's top level directory.
A command prompt window should appear displaying the host name of the computer you
are on and the address of all enabled Ethernet devices. Your HOST ID is the Ethernet
address displayed in the window. If more than one address is shown choose the one most
likely to be always enabled. If no Ethernet address is displayed, enable a network adaptor
and try again.
If you do not have access to the VERICUT CD, see Alternate Method to Determine Your
Windows License Server Computer’s HOST ID.
UNIX
1. Insert the CD into the license server computer’s CD-ROM drive.
2. Mount the CD (if your computer does not automatically mount it).
3. Change directories to the CD-ROM mount directory (e.g. cd /cdrom).
4. Type ./hostinfo.ux to run the program that determines the HOST ID.
5. The HOST ID is the “ID Prom” value returned from the command. Valid HOST IDs
are eight characters containing only 0-9 and A-F.
12
Installing CGTech Products
If you do not have access to the VERICUT CD, see Alternate Method to Determine Your
UNIX License Server Computer’s HOST ID.
13
Installing CGTech Products
14
Installing CGTech Products
VERICUT Installation
1. Insert the CD and run the Windows installation program.
If your computer does not automatically start the installation program, double-click on or
run the "install.exe" program from the CD.
2. Follow the installation "Wizard".
VERICUT uses a typical "Wizard" type installation where you step through a series of
screens to configure your installation. The last choice, prior to the "Finish" screen, begins
the installation.
Overview of the installation steps:
• Choose the installation language, then OK.
• Read through the Introduction screen, then Next.
• Accept the License Agreement then Next.
• Specify the folder path where VERICUT will be installed, then Next.
• Choose the type of installation. Choose Full (Full is recommended), Partial,
Minimal or Custom, then Next.
• Select the VERICUT platforms to install. Choose Windows (32 bit) or Windows
64 bit, depending on your operating system.
• Read through the VERICUT Platform Setup screen, then Next.
• Select desktop icon and start menu button to add to the installing user's profile.
Choose VERICUT, or VERICUT Limited, or Cutter Grinder, or Mold and Die,
then Next.
• Enter the license server host name (assumes the installing computer's host name,
but can be changed), then Next.
• Select default units, then Next.
• Install VERICUT by pressing the Install button.
• When the software install is complete, a screen will display enabling you choose
whether or not to display the post-installation configuration instructions, then
Next. You must have an Internet Browser to display the post-installation
configuration instructions.
• Finally press the Done button to quit the installer.
15
Installing CGTech Products
Where "hostname1" is the actual host name of the leader (or main) redundant server, and
"hostname2" and "hostname3" are the names of the follower servers.
Next installation task: Configure and Start the Windows License Server
16
Installing CGTech Products
The license server computer runs the license server program. This program must be
running on a computer that is network-accessible by VERICUT client computers. Valid
VERICUT licenses must be available on the license server in order for The VERICUT
software to operate.
VERICUT licensing is specific to each major version of VERICUT (6.2, 7.0, 7.1, etc.).
Licensing from earlier major versions will not allow newer versions to run. Point
releases, such as 7.0.1, are licensed by the major version. For example, VERICUT 7.0.1
only works with a 7.0 (or higher) license.
The following steps assume that you have a license email from CGTech for this major
VERICUT version, and you are ready to configure the license server and apply your
license. If you have not requested a license from CGTech, go back to the Introduction for
information about how to request a license.
The license email contains instructions on how to create a license file. Those instructions
are repeated here as well. Follow the instructions carefully and DO NOT ALTER ANY of
the content of the license email. Doing so may invalidate the license file and result in
errors when running VERICUT.
VERICUT uses the Sentinel RMS license server program from SafeNet . The Sentinel
RMS license server is a full featured software licensing tool used by several software
companies to license their application programs. Sentinel RMS contains optional features
not mentioned in this brief discussion of basic license server configuration. For more
information about advanced license server configuration options, see the Sentinel RMS
License Manager System Administrator's Guide.
17
Installing CGTech Products
1. Select Start > All Programs > CGTech VERICUT 7.2 > License Server Only >
Configure License & Setup Server.
2. In the command prompt window read the informational messages then press any key
to continue.
3. When the Create VERICUT License File screen displays, drag and drop the
VERICUT license email from Microsoft Outlook, or Outlook Express, into the Create
VERICUT License File screen. If you use another email program or cannot access the
license email from the license server computer, save the license email as a "Text
Only" or plain text file, then drag and drop the saved file into the Create VERICUT
License File screen. You can also Copy/Paste the email contents into the Create
VERICUT License File screen.
4. Close the Create VERICUT License File screen after the license file has been created.
5. Continue reading messages displayed in the command prompt screen, press any key
to continue.
6. When the command prompt window closes, the license server should be configured
for use and you can proceed to the next step.
18
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
19
Installing CGTech Products
The license server computer runs the license server program. This program must be
running on a computer that is network-accessible by VERICUT client computers. Valid
VERICUT licenses must be available on the license server in order for VERICUT to
operate.
VERICUT licensing is specific to each major version of VERICUT (5.4, 6.0, 6.1, etc.).
Licensing from earlier major versions will not allow newer versions to run. Point
releases, such as 6.1.1, are licensed by the major version. For example, VERICUT 6.1.1
only works with a 6.1 (or higher) license.
The following steps assume that you have a license email from CGTech for this major
VERICUT version, and you are ready to configure the license server and apply your
license. If you have not requested a license from CGTech, go back to the Introduction for
information about how to request a license.
The license email contains instructions on how to create a license file. Those instructions
are repeated here as well. Follow the instructions carefully and DO NOT ALTER ANY of
the content of the license email. Doing so may invalidate the license file and result in
errors when running VERICUT.
VERICUT uses the Sentinel RMS license server program from SafeNet. The Sentinel
RMS license server is a full-featured software licensing tool used by several software
companies to license their application programs. Sentinel RMS contains optional features
not mentioned in this brief discussion of a basic license server configuration. For more
information about advanced license server configuration options see the Sentinel RMS
License Manager System Administrator's Guide.
20
Installing CGTech Products
21
Installing CGTech Products
program. The program is called 'lswhere' and is located in the 'platform/license' directory
of your VERICUT installation. Execute the lswhere program from a command or
terminal shell to determine if the license server program is running. For example, if your
license server computer is a Sun computer running the SOLARIS operating system, and
VERICUT is installed in the /usr/cgtech60 directory, then type the following command:
/usr/cgtech60/solaris/license/lswhere
If the license server is running you should see the following information displayed by the
lswhere utility:
Sentinel RMS 8.0.5 Search Tool For License Servers
Copyright (C) 2006 SafeNet, Inc.
3. Copy the license keys from the CGTech license email to a text file.
4. Add the license keys to the license server and license file using lslic.
Add the license keys to the running license server and save them in the license file. In a
UNIX command or terminal shell execute the 'lslic' utility program from the
'platform/license' directory in your VERICUT installation. Continuing with our example
from above, the command would look like:
/usr/cgtech60/solaris/license/lslic –F
/users/mylogin/vericut60_license_keys.txt
22
Installing CGTech Products
23
Installing CGTech Products
The VERICUT license server computer is now configured to automatically start the
license server program, the VERICUT license keys exist in …/platform/license/cgtech.lf,
and the license server program is configured to read VERICUT license keys from the file.
You should now be able to run VERICUT on the license server computer using licenses
provided by the license server.
If errors occur, visit the VERICUT Users'Forum or contact CGTech technical support
via our website, just click on the support link.
24
Installing CGTech Products
Run VERICUT using the icon added to your desktop, or by clicking Taskbar: Start >
Programs > CGTech VERICUT x.x > VERICUT x.x (where "x.x" is the installed
version).
After the VERICUT window opens, press the green "Play to End" button (located
in the lower right corner of the VERICUT window). A short simulation will run.
If you do not have a "Machine Simulation" license, a notice displays. After pressing OK
in the notice dialogue, the workpiece will be cut but the machine will not move- this is
normal, since no Machine Simulation license is available.
You can check that you are running the expected VERICUT version by selecting Help >
About VERICUT. Available licenses are displayed by selecting Help > License ….
When finished, select File > Exit (located in the menu bar in the upper left corner of the
VERICUT window) to close the VERICUT window.
Congratulations!
Continue on to the next step if you have other computers that will run VERICUT and get
their licenses from the license server computer you just finished installing.
If errors occur, visit the VERICUT Users’ Forum or contact CGTech technical support
via our website, just click on the support link.
25
Installing CGTech Products
Once VERICUT is installed on the license server computer, and the license server is
running, you can setup VERICUT on each Windows client computer. In order to receive
licenses from the license server computer the client and license server computers must
communicate with each other over the network. Verification of client/server
communication was covered in previous instructions. See the section, Check Windows
Network Configuration for more information.
Follow the steps below to configure client computers to run VERICUT and receive
licenses from the license server. Steps differ depending on the type of network
configuration:
Multiple Computer installation — VERICUT is installed on the local disk of each
computer (client and license server) that will run VERICUT.
Multiple Computer Network installation — VERICUT is installed on a network
mapped disk. VERICUT is not locally installed on the client computer. The client
computer accesses VERICUT from the mapped disk.
NOTE: Do not create a license file or start the license server program on the client
computer. The license server computer was configured in previous installation
instructions.
26
Installing CGTech Products
2. Copy the file "Shortcut to VERICUT x.x" from the "windows\commands" directory
of your VERICUT installation to the desktop of each client computer. Rename the
shortcut as desired.
3. Optionally, copy the entire CGTech VERICUT x.x Start Menu folder from the license
server computer Start Menu to each client computer’s Start Menu.
1. Run VERICUT using the icon added to the client computers desktop (or other
desktop or Start Menu shortcut you created).
2. After the VERICUT window opens, press the green "Play to End" button
(located in the lower right corner of the VERICUT window). A short simulation will
run.
3. If your licensing does not include the "Machine Simulation" option, a notice displays.
After pressing OK in the notice dialogue, the workpiece will be cut but the machine
will not move- this is normal, since no Machine Simulation license is available.
4. You can also check that you are running the correct VERICUT version and the proper
licenses are available by selecting Help > About VERICUT.
5. When finished, select File > Exit (located in the menu bar in the upper left corner of
the VERICUT window) to close the VERICUT window.
If errors occur, visit the VERICUT Users’ Forum or contact CGTech technical support
via our website, just click on the support link.
If you need to configure one of the CAM Interface modules, go to one of the following:
Configuring the CATIA V5-to-VERICUT Interface for CATIA version 5
Configuring the EdgeCAM-to-VERICUT Interface
Configuring the ESPRIT-to-VERICUT Interface
Configuring the GibbsCam-to-VERICUT Interface (GibbsV)
Configuring the Mastercam-to-VERICUT Interface (MCAMV)
Configuring the NX-to-VERICUT Interface (NXV)
Configuring the Pro/E-to-VERICUT Interface (PROEV)
If you need to install the CAD Model Interface modules, go to Installing the Model
Interface Modules.
27
Installing CGTech Products
If you need to install the VERICUT TDM Interface, go to Installing the VERICUT TDM
Systems Interface.
28
Installing CGTech Products
Select to install only the license server program by choosing "Custom" on the Type of
Installation install screen. Then on the Choose VERICUT Components install window,
check only the "License" choice. Continue with the installation as directed. This choice
only applies to a Multiple Computer or Multiple Computer Network installation. When
installing the VERICUT License Server only, the License Server computer can be either
a Windows Computer or a UNIX computer.
29
Installing CGTech Products
Silent Mode
Silent mode, which enables an installer to run without any user interaction, is fully
supported on all UNIX platforms. A near-silent mode is possible on Windows. If you
choose to run this option, there will be no console or GUI output during installation.
Silent mode supports the setting of a target directory, shortcuts directory, and
Components/Features via either command-line arguments or a properties file. Silent
mode is supported in both the installer and uninstaller runtime environments.
InstallAnywhere and end-user-defined variables may be set through command-line
parameters and/or a properties file.
An installer properties file or a command-line parameter may trigger silent mode.
Tip: If the install.properties file is in the same directory as your installer, it will be
invoked automatically. However, if it is in a different directory or a different name, you
may use the following command line option to direct it to the relative path:
C:\\ <path to the installer> -f <path to the properties file>
30
Installing CGTech Products
NOTES:
1. File separators should be denoted by the "$/$" InstallAnywhere variable, or be
escaped.
2. Values may ignore case.
3. Silent mode will override action panel values.
4. In any mode on Windows systems, installers and uninstallers will always display the
very last "Cleaning-up" dialog box, as well as the "Preparing to install" panel.
INSTALLER_UI=Silent
USER_INSTALL_DIR=C:$/$cgtech7.1.1
CHOSEN_INSTALL_SET=Partial
VERICUT_PLATFORMS="Windows 32-bit",""
LICENSE_SERVER_HOSTNAME="LicenseServer"
DEFAULT_BASE_LIC_VAR="1) VERICUT"
DEFAULT_UNITS_VAR="","2) Millimeter"
USER_INPUT_DESKTOP_FLAG=1
USER_INPUT_QUICK_LAUNCH_FLAG=1
USER_INPUT_PROGRAM_GROUP_FLAG=1
USER_INPUT_ALL_USERS_FLAG=1
USER_INPUT_PROGRAM_GROUP_NAME=CGTech VERICUT 7.1.1
INSTALLER_UI=Silent
USER_INSTALL_DIR=C:$/$cgtech71
CHOSEN_INSTALL_SET=Full
VERICUT_PLATFORMS="Windows 64-bit",""
LICENSE_SERVER_HOSTNAME="LicenseServer"
31
Installing CGTech Products
DEFAULT_BASE_LIC_VAR="1) VERICUT"
DEFAULT_UNITS_VAR= "1) Inch",""
USER_INPUT_DESKTOP_FLAG=1
USER_INPUT_QUICK_LAUNCH_FLAG=1
USER_INPUT_PROGRAM_GROUP_FLAG=1
USER_INPUT_ALL_USERS_FLAG=1
USER_INPUT_PROGRAM_GROUP_NAME=CGTech VERICUT 7.1.1
DEFAULT_UNITS_VAR= "1) Inch",""
NOTES:
1. To install Windows 32 bit platform only:
VERICUT_PLATFORMS="Windows 32-bit",""
2. To install Windows 64 bit platform only:
VERICUT_PLATFORMS="","Windows 64-bit"
3. To install both the Windows 32 bit & 64 bit platforms:
VERICUT_PLATFORMS="Windows 32-bit"," Windows 64-bit"
4. Installing on UNIX Platforms:
VERICUT_PLATFORMS="HP - HP-UX","RS - IBM AIX","Solaris - Sun
Solaris"
5. The following new properties were added in VERICUT 7.1.1 for Silent Installer:
USER_INPUT_DESKTOP_FLAG=value
The USER_INPUT_DESKTOP_FLAG variable is used for adding icons to the
Desktop. A value of 0 does not add any icons to the Desktop. A value of 1 adds
icons to the Desktop. If the option is not specified, it defaults to 0.
USER_INPUT_QUICK_LAUNCH_FLAG=value
The USER_INPUT_QUICK_LAUNCH_FLAG variable is used for adding icons
to the Quick Launch taskbar. A value of 0 does not add any icons to the Quick
Launch taskbar. A value of 1 adds icons to the Quick Launch taskbar. If the
option is not specified, it defaults to 0.
USER_INPUT_PROGRAM_GROUP_FLAG=value
The USER_INPUT_PROGRAM_GROUP_FLAG variable is used for adding
icons and menus to the Programs Menu. A value of 0 does not add any icons or
32
Installing CGTech Products
menus to the Programs Menu. A value of 1 adds icons and menus to the Programs
Menu. If the option is not specified, it defaults to 0.
USER_INPUT_ALL_USERS_FLAG=value
The USER_INPUT_ALL_USERS_FLAG variable indicates if any icons added
by the previous three options are added for all users of the computer or only the
current user. A value of 0 adds icons for the current user only. A value of 1 adds
icons for all users (NOTE: this option requires Administrative privileges). If the
option is not specified, it defaults to 0.
33
Installing CGTech Products
If you plan to configure redundant license servers you should have identified the three (3)
required license server computers, provided their Host ID's to CGTech, and received a
license email containing the special license keys for redundant license servers. You
should also have specified the three license servers (in the order,
leader:follower1:follower2) during the VERICUT installation.
A redundant license server configuration requires a special license configured for three
(3) license servers. Earlier installation instructions explained how to request the license.
Redundant license server configuration should only be done by experienced system
administrators with networking experience.
NOTE: Each redundant server must have a static IP address. Dynamic IP addresses
cause poor performance or failure.
Follow the steps below to setup a Windows redundant license server configuration. These
steps must be done by an "Administrator" user. The steps assume you have received the
license email from CGTech.
1. Save License File from License Email.
(requires privileges to write to the VERICUT installation folders)
A. Select Start > All Programs > CGTech VERICUT 7.0.x > License Server
Only > Save License File from License Email.
B. When the Create VERICUT License File screen displays, drag and drop the
VERICUT license email from Microsoft Outlook, or Outlook Express, into
the Create VERICUT License File screen. If you use another email program
or cannot access the license email from the license server computer, save the
license email as a "Text Only" or plain text file, then drag and drop the saved
file into the Create VERICUT License File screen. You can also Copy/Paste
the email contents into the Create VERICUT License File screen.
34
Installing CGTech Products
C. The Create VERICUT License File screen's text area displays all the added
license keys, followed by the message:
D. "License file C:\cgtech60x\windows\license\cgtech.lf created successfully".
E. Close the Create VERICUT License File screen after the license file has been
created.
A. Run …\windows\license\WrlfTool.exe.
B. In the WRlfTool panel select File -> New.
C. Press the Add Server button (in the upper half of the window).
D. In Add Server to Pool panel, enter the Hostname and IP Address (or IPX
Address) for the "leader" license server computer, and then press OK.
E. Press the Add Server button two more times to add the Host Names and IP
addresses for each of the two "follower" license server computers. All three
redundant server host names and IP addresses should now appear in the
Redundant Servers list.
F. Press the Add License button (in the lower half of the window).
G. In the Add Redundant License panel, select "Read License(s) from file".
H. Press Browse and navigate to, and select, the cgtech.lf file you saved in step
1C above. Press Open, and then press OK.
I. The Edit License panel opens, showing the first VERICUT license key in the
License Code field on the right side of the panel, and the number of available
licenses displayed in the Number of Tokens field (lower left in the panel).
J. On the right side of the panel the 3 license server host names appear in the
Server column. Check the Include checkboxes for all 3.
K. Enter the value from Number of Tokens (lower left) in the Num Tokens
column to the right of the first or "leader" server. This assigns all tokens for
the displayed license key to the leader license server. Make sure that the Num
Tokens values, for the two "follower" servers, is set to zero.
L. Select Next License >> at the bottom of the panel to display the information
for the next VERICUT feature. Repeat the previous step to assign all tokens
for this license key to the leader license server.
M. Repeat for each license key.
N. Press Done at the bottom of the panel after the last license key is completed.
O. Select File->Save As and save the redundant license file as "cgtech.lf" in the
…/windows/license folder of the leader license server's VERICUT
installation.
35
Installing CGTech Products
NOTES:
1. The license server computer requires TCP/IP network protocol installed on the
network adaptor. See the section, Check Windows Network Configuration for more
information.
2. The following steps must be done by an Administrator user.
3. If you are installing on a computer running Windows 7 Pro you will need to do the
following before continuing with the Configure License & Setup Server steps.
• Go to Control Panel > User Accounts > Change User Account Control
settings (aka UAC).
• Change it from Default to Never notify
The Never Notify setting is to be used when using a program not certified for
Windows 7 because it does not support User Account Control (like Sentinel or
VERICUT).
36
Installing CGTech Products
NOTES:
1. Be sure to start the 3 redundant license server computers in the same order
specified when the redundant license file was created. Starting them out-of-
order could cause problems designating the “leader” computer and assigning
tokens. You should wait 1 or 2 minutes between starting each license server
computer to make sure that it is fully started and ready to communicate with
the next one. There is no "maximum" time limit between starting the license
server computers.
2. When starting a redundant license server, the error message "lservrc not
found" may display. This message can be ignored.
37
Installing CGTech Products
Where "hostname1", etc. are the names of your 3 redundant license servers. The
names MUST be specified in the same order used when the redundant license file
was created. The three hostnames are separated by colons ( : ).
NOTE: For more detailed information about setting up a redundant license server
configuration, see Chapter 3 in the Sentinel RMS License Manager System
Administrator's Guide. A pdf version of this document is available directly on the
VERICUT CD in the file SLM71sys.pdf.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
38
Installing CGTech Products
If you plan to configure redundant license servers you should have identified the three (3)
required license server computers, provided their Host ID's to CGTech, and received a
license email containing the special license keys for redundant license servers. You
should also have specified the three license servers (in the order,
leader:follower1:follower2) during the VERICUT installation.
A redundant license server configuration requires a special license configured for three
(3) license servers. Earlier installation instructions explained how to request the license.
Redundant license server configuration should only be done by experienced system
administrators with networking experience.
NOTE: Each redundant server must have a static IP address. Dynamic IP addresses
cause poor performance or failure.
Follow the steps below to setup a UNIX redundant license server configuration. These
steps must be done by a "root" user. The steps assume you have received the license
email from CGTech.
1. Save the license email to a text file.
39
Installing CGTech Products
C. In the rlftool menus, add licenses from the file saved in step 1 above.
40
Installing CGTech Products
The rlftool program automatically saves the redundant license file as "lservrlf" in
your current working directory.
4. Copy the redundant license file to all 3 license server’s VERICUT installations.
Copy the file lservrlf to …/platform/license/cgtech.lf for all 3 redundant license
server's VERICUT installations.
$CGTECH_PRODUCTS/license/lserv -rlf
$CGTECH_PRODUCTS/license/cgtech.lf
41
Installing CGTech Products
Reboot the leader license server computer after adding the license server program to
your system's startup process to verify that it starts correctly upon reboot. If it is not
possible to reboot your license server computer now, start the license server program
manually using your platform's system management utility.
7. Configure and Start the Remaining 2 "follower" License Servers
Configure and start the license server on the remaining 2 "follower" license servers,
as you did for the "leader" license server in the steps 5 and 6.
NOTES:
1. Be sure to start the 3 redundant license server computers in the same order
specified when the redundant license file was created. Starting them out-of-
order could cause problems designating the "leader" computer and assigning
tokens. You should wait 1 or 2 minutes between starting each license server
computer to make sure that it is fully started and ready to communicate with
the next one. There is no "maximum" time limit between starting the license
server computers.
2. When starting a redundant license server, the error message "lservrc not
found" may display. This message can be ignored.
If the license server is running you should see the following information displayed by
the lswhere utility:
Sentinel RMS Development Kit 8.0.5.0 Search Tool For License Servers Copyright
(C) 2006 SafeNet, Inc.
Server Address : 199.1.1.123
Server Name : mycomputer
(in this example the server computer's host name is 'mycomputer' and its IP
address is 199.1.1.123)
42
Installing CGTech Products
NOTE: For more detailed information about setting up a redundant license server
configuration, see Chapter 3 in the Sentinel RMS License Manager System
Administrator's Guide. A pdf version of this document is available directly on the
VERICUT CD in the file SLM71sys.pdf.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
43
Installing CGTech Products
The following describe the different Windows "Start Menu" choices under Start > All
Programs > CGTech VERICUT 7.0 > License Administration. Some of these choices
only display information and some require a Windows administrative user in order to
make changes to system settings.
License Utilities
"License Utilities" choices are intended to help setup licensing or diagnose license
problems on either the license server computer or the VERICUT client computer.
44
Installing CGTech Products
45
Installing CGTech Products
Display Host ID
Display the Ethernet address of all enabled network adapters on this computer. The
user selects one of these displayed Ethernet addresses as the HOST ID used to lock
the license server to this computer. The program that displays the Ethernet addresses
uses the exact same logic as the license server program. When a license is added to
the license server program, it is compared against enabled network adapters. If the
network adaptor encrypted in the license key does not match any of the enabled
network adaptors, the key is not added to the license server.
46
Installing CGTech Products
The Create License panel's text area displays all the added license keys, followed by
the message "License file C:\cgtech70\windows\license\cgtech.lf created
successfully". The license server program reads the cgtech.lf license file when it
starts, and adds valid license keys to the running license server.
47
Installing CGTech Products
program to remove the current licenses, then re-reads the license keys in the cgtech.lf
license file and adds them to the running license server. For more information about
the lslic program see the Sentinel RMS License Manager System Administrator's
Guide.
48
Installing CGTech Products
If you do not have access to the VERICUT CD you can display the HOST ID as follows:
• Open a Command Prompt window (also called a DOS window)
• Type in the window: Ipconfig /all
The value shown to the right of "Physical Address" is typically the HOST ID. Valid IDs
are 12 characters and contain only the characters 0-9 and A-F. If your computer has
multiple network adapters, the license server program compares the address encrypted in
the license keys with enabled network adapters. If a network adapter address matching
the encrypted key address is found then the license is added to the server.
The following Physical Addresses are not valid, and indicate something is wrong with the
TCP/IP network protocol configuration for the Ethernet device, or indicates the card is
not enabled or available:
000000000000
204c4f4f5020
ffffffff
ffffffffffff
NOTE: The license server delivered with this version of VERICUT only requires
the device to be enabled. It no longer requires it to be connected or have an active
network transport such as IPX/SPX.
See the section on Check Windows Network Configuration if you are having trouble
getting a valid Physical Address.
49
Installing CGTech Products
If you do not have access to the VERICUT CD, one of the following commands will
display the HOST ID on each of the different UNIX platforms.
HP: /usr/bin/uname -i convert the decimal number that is returned to a hex
number
RS: /usr/sbin/hostid returns a nine or ten character number, remove the first
2 characters
(a zero is added to the front of a 9 character Prom ID for the license file)
Solaris: /usr/ucb/hostid use the number as displayed
50
Installing CGTech Products
In any VERICUT installation there is a computer that functions as the license server
computer. There are also one or more client computers that run VERICUT and
communicate with the license server computer to get licenses. In a stand-alone
configuration the license server computer and the VERICUT client computer are one-in-
the-same, but the same network communication requirements apply. The following
checks ensure that the license server computer and the VERICUT client computer(s) can
communicate, and that the VERICUT client computers can successfully run VERICUT.
Checks for both the License Server Computer and VERICUT Client
Computers
51
Installing CGTech Products
52
Installing CGTech Products
3. Verify client and license server computers can communicate with each other.
Both client and license server computers must have host names and valid IP
addresses. The mechanism for assigning host names and IP addresses varies with the
network configuration. See your site's network administrator if you are not familiar
with how your network is configured.
The easiest way to verify communication between computers is to "ping" each one
from the other. Open a command prompt window and type:
ping COMPUTER1
(where 'COMPUTER1' is the host name of the computer you need to
communicate with)
53
Installing CGTech Products
You should ping the client from the license server computer and the license server
computer from the client since both computers must know about each other for proper
communication. If the ping test fails contact your site's network administrator to
correct the problem.
In some network configurations there may be a router, gateway or other network device
that acts like a firewall between the client and license server computer. In this case, the
ping test will succeed but licensing will fail since the router or firewall must be
configured to allow TCP/IP to pass UDP packets through port 5093. For this and other
complex network configurations contact your site's network administrator and see the
Sentinel RMS License Manager System Administrator's Guide, for more information
about configuring the Sentinel RMS license server and clients. A pdf version of this
document is available directly on the VERICUT CD in the file SLM71sys.pdf.
54
Installing CGTech Products
Use the appropriate section below to properly configure your network device for
VERICUT on Windows computers.
In any VERICUT installation there is a computer that functions as the license server
computer. There are also one or more client computers that run VERICUT and
communicate with the license server computer to get licenses. The following checks
ensure that the license server computer and the VERICUT client computer(s) can
communicate, and that the VERICUT client computers can successfully run VERICUT.
Verify the client and license server computers can communicate with each other.
Both client and license server computers must have host names and valid IP addresses.
The mechanism for assigning host names and IP addresses varies with the network
configuration, but most UNIX system use the /etc/hosts file to specify host names and IP
addresses on a network. See your site's network administrator if you are not familiar with
how your network is configured.
The easiest way to verify communication between computers is to "ping" each one from
the other. In a UNIX terminal shell type:
55
Installing CGTech Products
ping COMPUTER1
(where 'computer1' is the host name of the computer you want to communicate with)
You should ping the client from the license server computer and the license server
computer from the client since both computers must know about each other for proper
communication. If the ping test fails contact your site's network administrator to correct
the problem.
If you do not have a network or system administrator, and you have access to the 'root'
login, you can modify the /etc/hosts file in order to establish communication between the
license server computer and the client computers. See the section, UNIX hosts File for
basic hosts file configuration instructions.
In some network configurations there may be a router, gateway or other network device
that acts like a firewall between the client and license server computers. In this case, the
ping test will succeed but licensing will fail since the router or firewall must be
configured to allow TCP/IP to pass UDP packets through port 5093. For this and other
complex network configurations contact your site’s network administrator and see the
Sentinel RMS License Manager System Administrator's Guide for more information
about configuring the Sentinel RMS license server and clients.
56
Installing CGTech Products
Edit the /etc/hosts file for each client computer, adding a line for the license server
computer.
NOTE: If you do not know the IP address of the license server computer, you can use
the ping command while logged-in on the license server computer. In a terminal or
command shell, type:
ping mycomputer
Where 'mycomputer' is the name of the license server computer.
If ping is not in your execution path, you can try /usr/sbin/ping. If the ping
command does not display the IP address of the license server computer, try ping
with the –s option.
Verify client and license server computers can communicate with each
other
Both client and license server computers must have host names and valid IP addresses.
The mechanism for assigning host names and IP addresses varies with the network
configuration, but most UNIX system use the /etc/hosts file to specify host names and IP
57
Installing CGTech Products
addresses on a network. See your site’s network administrator if you are not familiar with
how your network is configured.
The easiest way to verify communication between computers is to “ping” each one from
the other. In a UNIX terminal shell type:
ping COMPUTER1
(where 'computer1' is the host name of the computer you want to communicate with)
You should ping the client from the license server computer and the license server
computer from the client since both computers must know about each other for proper
communication.
In some network configurations there may be a router, gateway or other network device
that acts like a firewall between the client and license server computer. In this case, the
ping test will succeed but licensing will fail since the router or firewall must be
configured to allow TCP/IP to pass UDP packets through port 5093. For this and other
complex network configurations contact your site’s network administrator and see the
Sentinel RMS License Manager System Administrator's Guide, for more information
about configuring the Sentinel RMS license server and clients. A pdf version of this
document is available directly on the VERICUT CD in the file SLM71sys.pdf.
58
Installing CGTech Products
An NX part file can be opened directly in VERICUT. The following describe the
environment variables that need to be set.
Additional requirements:
59
Installing CGTech Products
Mount a UNIX CD
The CD-ROM drive must be mounted with "read" and "execute" access to run the
VERICUT installation program. Some systems, may automatically mount the CD without
the proper access and must be dismounted and re-mounted manually
• Use the "df" command to list mounted file systems. If mounted, the device name
will appear under the "Filesystem" heading (beginning with "/dev") and the mount
directory will appear under the "Mounted on" heading (e.g. "/cdrom" or
"/CDROM").
• If /cdrom has "read" and "execute"— return to the previous installation task.
• If /cdrom does NOT have "read" and "execute — Unmount the incorrectly
mounted device using the "umount /CDROM" command.
Tips:
• Avoid typing errors by cutting and pasting device names.
• If the "mount" command is not in your execution path, try "/etc/mount".
60
Installing CGTech Products
1. Make sure the directory containing the PFS utilities (/usr/sbin) is in your
execution PATH.
2. Edit (or create) the /etc/pfs_fstab file to contain a line like this:
Where:
You can now continue with the VERICUT installation. When you are finished with the
install you can unmount the CD with:
61
Installing CGTech Products
62
Installing CGTech Products
63
Installing CGTech Products
64
Installing CGTech Products
A. Select Start > All Programs > CGTech VERICUT 7.0 > License Server Only >
Save License File from License Email.
B. Drag and drop the VERICUT license email from Microsoft Outlook, or Outlook
Express, into the Create License File panel. If you use another email program, or
cannot access the license email from the license server computer, then save the
license email as a "Text Only" or plain text file and drag/drop the saved file into
the Create License File panel.
C. Close the Create License File panel after the "success" message displays.
If errors occur, visit the VERICUT Users’ Forum or contact CGTech technical support
via our website, just click on the support link.
65
Installing CGTech Products
These instructions assume you have received a new license from CGTech via email. If
you have not, and you need to request a new license, see the Request a VERICUT
License instructions in the section Determine the HOST ID and Request a License. To
update your VERICUT license on a UNIX license server, do the following (on the license
server computer):
1. Copy the license keys from the CGTech license email to a text file.
NOTE: When pasting into the plain text editor make sure that the long license key
lines are not automatically truncated or split into separate lines.
2. Add the license keys to the license server and license file using lslic.
Add the license keys to the running license server and save them in the license file. In
a UNIX command or terminal shell execute the 'lslic' utility program from the
'platform/license' directory in your VERICUT installation. Continuing with our
example from above, the command would look like:
/usr/cgtech70/solaris/license/lslic –F /users/mylogin/vericut70_license_keys.txt
Where /usr/cgtech70 is the VERICUT installation folder on a Sun SOLARIS
platform.
The license keys are loaded from the file saved in step 1D above. The –F option
adds the keys to the license server from the specified file, and saves them in
'cgtech.lf' located in the 'platform/license' directory in your VERICUT
installation.
66
Installing CGTech Products
67
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
68
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
69
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
70
Installing CGTech Products
The following describes how to start a temporary license server. But, it is strongly
recommended that you configure the license server program to automatically start using
Windows services. If for some reason you cannot configure the license server service,
then it can be temporarily started.
To start a temporary license server select:
Start > All Programs > CGTech VERICUT 7.2 > License Server Only > Run
Temporary License Server.
You could add a Windows shortcut to your desktop to make access to this procedure
easier.
This Start menu item could also be added to the Windows Startup folder so that it
automatically starts when you log-in.
NOTES:
1. A temporary license server can only be started by an Administrator user.
2. The temporary license server process is owned by the specific user that starts it.
When that user logs-out, the license server program terminates.
3. Starting a temporary license server stops the Windows license server service if it
is running.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
71
Installing CGTech Products
NOTE: The following must be done logged-in as the computer's 'root' user. Do not 'set
user' (su) to root as this does not always correctly execute the root account's login
process.
The following describes how to start a temporary license server. But, it is strongly
recommended that you configure the license server program to automatically start using
your UNIX system manager’s utility. If for some reason you cannot configure the license
server to start automatically, then it can be temporarily started.
The VERICUT installation includes a UNIX script that launches the license server
program. The script file name is "start_server" and is located in the 'platform/license'
directory of your VERICUT installation, where platform is: hp, solaris, or rs.
To start the license server temporarily:
1. Open a command shell.
2. Execute the start_server script from a command or terminal shell.
…/cgtech72/platform/license/start_server
NOTE: The temporary license server process is owned by the "root" user that starts it.
When that user logs-out, the license server program terminates.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
72
Installing CGTech Products
NOTE: There may be program folder/files that are not removed by uninstalling. These
were created after VERICUT was installed and will have to be removed manually.
73
Installing CGTech Products
VERICUT point releases for Windows are available on the CGTech web site. The
following steps will guide you through downloading and installing a VERICUT point
release (we'll use 7.1.6 as an example below):
Download Instructions:
The VERICUT 7.1.6 Windows version (Windows Win7, Win7 64, XP, and XP64)
is available for download from our web site. Follow this link to open the on-line
form to begin the download process:
http://www.cgtech.com/usa/support/software-update/
To download the file, you will need your Company ID and the access code from the
"VERICUT 7.1.6 is available for download" email that was sent to all customers on
maintenance. If you are not currently on maintenance, contact your CGTech
representative.
74
Installing CGTech Products
VERICUT on Win7 64, Vista 64 and XP 64 will likely require installation of the correct
version of Microsoft’s C++ run-time libraries. You may also need to install the correct
version of Microsoft’s C++ run-time libraries if you are installing the Model Interface
Modules. The following describes the 64 bit version of the libraries. To install the 32 bit
version of the libraries use the vcredist_x86.exe installer.
75
Installing CGTech Products
VERICUT 5.2 and 5.3 require an environment variable setting to specify the version of
the license file.
NOTE: VERICUT 5.2.1 (or higher) is required if you want to use a later version
license, such as a 5.3 or 5.4 license.
For example, to run VERICUT 5.2.1 using a later VERICUT license, such as 5.4. the
environment variable CGTECH_LICENSE_VERSION must be set to the value "5.4".
This can be done by modifying the following file:
\cgtech521\windows\commands\cgtenv.bat (or the UNIX 'cgtenv') Either add or
modify the following line at the end of the file:
WINDOWS
set CGTECH_LICENSE_VERSION=5.4
UNIX
CGTECH_LICENSE_VERSION=5.4; export CGTECH_LICENSE_VERSION
76
Installing CGTech Products
77
Installing CGTech Products
Prerequisites
CATV 7.0 requires CATIA V5 (R16 or later) and VERICUT 7.0 (or later). It is only
available for the 32bit and 64bit Windows platforms.
1. "Windows Script" should be version 5.6 or later. The latest version of Windows
Script is available from Microsoft's download site. Search for "Windows Script"
and pick the latest version offered. Note that there is one download for Windows
2000 and XP, and another for 98, ME and NT.
2. Two dynamic link libraries, FM20.dll and FM20ENU.dll, which are distributed
with Microsoft Office. If some portion of Office is installed then FM20.dll and
FM20ENU.dll should already be present (in the "Windows\System32" folder or
an equivalent) and registered.
Configuration
The CGTech software installation procedure places the files required by CATV in a sub-
folder. If you elected to install the software in the default folder "C:\Program
Files\cgtech\x.x.x\" (where x.x.x is the VERICUT release number), then for VERICUT
7.14, the CATV folder will be "C:\Program Files\cgtech\7.1.4\windows\catv5" or
"C:\Program Files\cgtech\7.1.4\\windows64\catv5".
One of the files is "CATV.bat", which sets at least two environment variables before
invoking the executable "CATV.exe". The first environment variable is
CGTECH_PRODUCTS and it points to the platform specific folder of the CGTech
software. For CATV the platform is either "windows" or "windows64". The second
environment variable is CGTECH_LIBRARY and it points to the folder containing
VERICUT specific files distributed with the product. These include "init.VcProject" and
"initm.VcProject" which are used by "CATV.exe" as project and setup templates if no
other file is specified by the user. "CATV.bat" is generated during the installation
procedure and there should be no need to edit the definition of either of these mandatory
environment variables.
78
Installing CGTech Products
You can place a shortcut to the CATV batch file on your Windows Desktop. If you do
so, we suggest that you alter the properties of the shortcut so that it runs in a minimized
window. This will avoid having an almost empty command window on screen for the
batch process. An alternative is to trigger the batch file from an icon on one or more of
CATIA's toolbars. To assist in setting this up, there is a CATIA macro script in the
CATV5 folder, called "CATV.CATScript". There are two icon files in sub-folders,
"Small\I_CATV.bmp" and "Normal\I_CATV.bmp".
If you wish to have an icon ( ) on a CATIA toolbar, the two icon files must be placed
where CATIA expects to find them. The paths depend on where you have CATIA
installed, but typically you will find a "small" and "normal" folder under "C:\Program
Files\Dassault Systemes\B16\intel_a\resources\graphic\icons". Place the two versions of
the CATV icon, both called "I_CATV.bmp", in the appropriate folders.
79
Installing CGTech Products
brief period. The CATV icon ( ) will probably be on the twelfth page. Pick it
and "Close" the "Icon Browser".
16. Back on the "Customize" dialog, position the mouse cursor over the name of the
macro, CATV.CATScript, in the right-hand list, depress the left mouse button,
and drag the cursor to the toolbar where you want the icon to appear. It's counter-
intuitive, but you drag the macro name, not the icon! Repeat this step if you want
the icon to appear on more than one toolbar.
17. "Close" the "Customize" dialog.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the CATIA V5-to-VERICUT Interface. For
complete details on using the CATIA V5-to-VERICUT Interface, see CATIA V5-to-
VERICUT Interface, in the CAD/CAM Interfaces section of Converters and
CAD/CAM Interfaces, located in the CGTech Help Library.
80
Installing CGTech Products
Six files are required by the VERICUT interface in an existing Edgecam 10.0 system.
Four of these files are language dependent and must be copied from the appropriate
English, French, or German folder. The distributed files are:
VericutPDI.exe
VericutSetPDI.exe
VericutPDI.dfn (language dependent)
VericutPDI.pdi (language dependent)
VericutSetPDI.pdi (language dependent)
VericutPDI.lan (language dependent)
81
Installing CGTech Products
Edgecam checks file dates of "dfn" and "pdi" each time it executes and updates the
master menu file when new files are detected. The file date for the VericutPDI.dfn,
VericutPDI.pdi, and VericutSetPDI.pdi files must be newer than the last time Edgecam
updated its master menu file. After moving the above files to their proper locations, use a
text editor to force the VericutPDI.dfn, VericutPDI.pdi, and VericutSetPDI.pdi file dates
to a current value. You only need to do this once before starting Edgecam.
The folder path where VERICUT is installed must be defined in an environment variable
for the Edgecam interface PDI to spawn the VERICUT process.
For example
CGTECH_INSTALL=C:\Program Files\cgtech\x.x.x\
Where x.x.x is the VERICUT release number. For VERICUT 7.1.4 the environment
variable would be set to CGTECH_INSTALL=C:\Program Files\cgtech\7.1.4\.
The following is included to enable you to create a .bat file that, when executed, copies
the necessary VERICUT-to-EdgecamInterface files from the VERICUT installation to
the correct Edgecam locations and renames the Edgekrnl.mnu to be Edgekrnl.old thus
forcing Edgecam to recompile its menus.
82
Installing CGTech Products
@echo on
rem Following line references the installation folder for VERICUT, change as
required.
set CGTECH_INSTALL=C:\Program Files\cgtech\x.x.x\
rem Where x.x.x is the VERICUT version number.
Copy %CGTECH_INSTALL%\windows\edgecam\*.exe
%EDGECAM_INSTALL%\Cam\PDI\Menu-Run
Copy %CGTECH_INSTALL%\windows\edgecam\English\vericutpdi.lan
%EDGECAM_INSTALL%\Language
Copy %CGTECH_INSTALL%\windows\edgecam\English\VericutPDI.dfn
%EDGECAM_INSTALL%\Language
Copy %CGTECH_INSTALL%\windows\edgecam\English\VericutPDI.pdi
%EDGECAM_INSTALL%\Cam\PDI\Src
Copy %CGTECH_INSTALL%\windows\edgecam\English\VericutPDI.dfn
%EDGECAM_INSTALL%\Cam\PDI\Src
pause
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the Edgecam-to-VERICUT Interface. For
complete details on using the Edgecam-to-VERICUT Interface, see Edgecam-to-
VERICUT Interface, in the CAD/CAM Interfaces section of Converters and
CAD/CAM Interfaces, located in the CGTech Help Library.
83
Installing CGTech Products
Seven files are required for the VERICUT interface in an existing Edgecam system. Four
of these files are language dependent and must be copied from the appropriate English,
French, or German folder.
The distributed files are:
VericutPDI.exe
VericutSetPDI.exe
VericutPDI.dfn (language dependent)
VericutPDI.pdi (language dependent)
VericutSetPDI.pdi (language dependent)
VericutPDI.lan (language dependent)
Vericut.commands
These files are located in the \cgtech\x.x.x\windows\edgecam or
\cgtech\x.x.x\windows64\edgecam folder of your VERICUT installation. The x.x.x
represents the VERICUT version number. For VERICUT 7.1.4 the x.x.x would be 7.1.4.
84
Installing CGTech Products
Edgecam checks file dates of "dfn" and "pdi" each time it executes and updates the
master menu file when new files are detected. The file date for the VericutPDI.dfn,
VericutPDI.pdi, and VericutSetPDI.pdi files must be newer than the last time EdgeCAM
updated its master menu file. After moving the above files to their proper locations, use a
text editor to force the VericutPDI.dfn, VericutPDI.pdi, and VericutSetPDI.pdi file dates
to a current value. You only need to do this once before starting EdgeCAM.
The folder path where VERICUT is installed must be defined in an environment variable
for the Edgecam interface PDI to spawn the VERICUT process.
For example:
CGTECH_INSTALL=C:\Program Files\cgtech\x.x.x\
Where x.x.x is the VERICUT release number. For VERICUT 7.1.4 the environment
variable would be set to CGTECH_INSTALL=C:\Program Files\cgtech\7.1.4\.
The following is included to enable you to create a .bat file that, when executed, copies
the necessary VERICUT-to-Edgecam Interface files from the VERICUT installation to
the correct Edgecam locations and renames the Edgekrnl.mnu to be Edgekrnl.old thus
forcing Edgecam to recompile its menus.
85
Installing CGTech Products
The lines shown below need to be copied to the Edgecam_Inst.bat file (watch line wrap):
@echo on
Copy %CGTECH_INSTALL%windowsedgecam*.exe
%EDGECAM_INSTALL%CamPDIMenu-Run
Copy %CGTECH_INSTALL%windowsedgecamEnglishvericutpdi.lan
%EDGECAM_INSTALL%Language
Copy %CGTECH_INSTALL%windowsedgecamEnglishVericutPDI.dfn
%EDGECAM_INSTALL%Language
Copy %CGTECH_INSTALL%windowsedgecamEnglishVericutPDI.pdi
%EDGECAM_INSTALL%CamPDISrc
Copy %CGTECH_INSTALL%windowsedgecamEnglishVericutPDI.dfn
%EDGECAM_INSTALL%CamPDISrc
pause
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the Edgecam-to-VERICUT Interface. For
complete details on using the Edgecam-to-VERICUT Interface, see Edgecam-to-
VERICUT Interface, in the CAD/CAM Interfaces section of Converters and
CAD/CAM Interfaces, located in the CGTech Help Library.
86
Installing CGTech Products
Five files are required for the VERICUT interface in an existing Edgecam system. Four
of these files are language dependent and must be copied from the appropriate English,
French, or German folder.
The distributed files are:
VericutPDI.exe
VericutPDI.dfn (language dependent)
VericutPDI.pdi (language dependent)
VericutPDI.lan (language dependent)
Vericut.commands
Edgecam checks file dates of "dfn" and "pdi" each time it executes and updates the
master menu file when new files are detected. The file date for the VericutPDI.dfn and
VericutPDI.pdi files must be newer than the last time Edgecam updated its master menu
file. After moving the above files to their proper locations, use a text editor to force the
VericutPDI.dfn and VericutPDI.pdi file dates to a current value. You only need to do this
once before starting Edgecam.
87
Installing CGTech Products
To enable the Edgecam interface PDI to spawn the VERICUT process, you also need to
define three environment variables, CGTECH_INSTALL, CGTECH_PRODUCTS
and LSHOST.
For example;
C:\Program Files\cgtech\x.x.x\windows
CGTECH_PRODUCTS or
C:\Program Files\cgtech\x.x.x\windows64
LSHOST server_name
CGTECH_INSTALL is set to the top level folder where VERICUT is installed. In the
above table, x.x.x represents the VERICUT release number. For VERICUT 7.1.4 the
environment variable would be set to C:\Program Files\cgtech\7.1.4.
CGTECH_PRODUCTS is set to the folder for the specific operating system of the
computer running VERICUT: either "windows" or "windows64". For a typical
VERICUT 7.1.4 installation this variable is set to C:\Program Files\cgtech\7.1.4\windows
or C:\Program Files\cgtech\7.1.4\windows64.
LSHOST is set to the name of the license server computer.
Use the Microsoft Windows Control Panel > System Properties: Advanced tab,
Environment Variables feature to define these environment variables. See Microsoft
Windows Help for more information.
To add an Edgecam-to-VERICUT menu option to the Edgecam main menu bar, complete
the following:
1. Start Edgecam
2. Open an Edgecam part with an existing machining sequence.
3. In the Edgecam main menu bar select Options > Manufacture, or click on the
(Switch to Manufacture Mode) icon to switch to manufacturing mode.
88
Installing CGTech Products
4. Once in Manufacturing mode, right click on the menu bar and choose Customise
from the pull-down list.
5. Select the Transfer tab and click on the Menu option, Load button.
89
Installing CGTech Products
6. Select Vericut.commands, then Open. The Vericut menu and pull-down option
list should now be added to the Edgecam main menu bar as shown below.
90
Installing CGTech Products
Edgecam 2011
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the Edgecam-to-VERICUT Interface. For
complete details on using the Edgecam-to-VERICUT Interface, see Edgecam-to-
VERICUT Interface, in the CAD/CAM Interfaces section of Converters and
CAD/CAM Interfaces, located in the CGTech Help Library.
91
Installing CGTech Products
First, create a directory named VericutAddin in your ESPRIT AddIns folder. If you have
ESPRIT installed in the default location, the folder you will need to create will be at
C:\Program Files (x86)\D.P.Technology\ESPRIT\AddIns\VericutAddin.
Next, copy all the provided source files into your VericutAddin directory. For reference,
here is the list of files you should copy:
blank.bat
cgtech_esprit.dll
extensibility.dll
Interop.Esprit.dll
Interop.EspritComBase.dll
register-dll.bat
register-vericut-addin-32.reg
register-vericut-addin-64.reg
unregister-dll.bat
VericutAddin.dll
VericutAddin.tlb
Next, you will need to register your files with the Windows registry and with ESPRIT so
that it will be able to find the Add-In when starting up.
You need to determine if your operating system is 32-bit or 64-bit. You can easily check
this by going to the Start menu, Right-clicking on the "My Computer" entry, and
selecting Properties. This should show you the name of your operating system. If there is
a 64 or 64-bit or x64 or x86-64, this means that your operating system is 64-bit and you
will need to double-click the file register-with-esprit-64.reg. If you don't see anything
indicating 64-bit, you're operating system is 32-bit and you will need to double-click the
file register-with-esprit-32.reg. After double-clicking the appropriate file, you will be
asked to confirm if you want to add an entry to the registry. Select yes and you should
receive a confirmation message that the value was added successfully to the registry.
The other file you need to run is register-dll.bat. You will first need to edit this file to
point to your specific ESPRIT AddIns folder. To edit, you must right-click and select
Edit, choosing Notepad to edit it with if prompted. By default, the folder specified is the
default install location for ESPRIT. Even if you have ESPRIT installed in the default
location, it is strongly recommended to double-check that the folder specified in
92
Installing CGTech Products
register-dll.bat is the same folder where you copied the files previously. If you need
to edit the install location, only change text on the line highlighted in red below:
C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\RegAsm.exe "C:\Program
Files (x86)\D.P.Technology\ESPRIT\Addins\VericutAddin\VericutAddin.dll"
/codebase /tlb
For example, if you have ESPRIT installed under T:\Applications\cad_cam\, the line in
your file would look like this:
C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\RegAsm.exe
"T:\Applications\cad_cam\D.P.Technology\ESPRIT\Addins\VericutAddin\VericutA
ddin.dll" /codebase /tlb
Also keep in mind that all the above text should be on the same line. It's only split onto
multiple lines in Word. When you're done editing, save and close the file, then double-
click to run it. You should see a console window with the text from the file in it. This will
tell you if there were any problems running the script.
If everything was successful, you should be able to open ESPRIT and see that the
ESPRIT-to-VERICUT Interface been loaded as an Add-In. There should also be a menu
entry under Tools => VERICUT.
Environment Variables
In order to use the ESPRIT-to-VERICUT interface, you also need to define four
environment variables, CGTECH_INSTALL, CGTECH_PRODUCTS, LSHOST and
CGTECH_LANGUAGE.
For example;
Environment Variable
Variable Value
Name
C:\Program Files\cgtech\x.x.x\windows
CGTECH_PRODUCTS or
C:\Program Files\cgtech\x.x.x\windows64
LSHOST server_name
93
Installing CGTech Products
C:\Program Files\cgtech\x.x.x\windows\Esprit\language
CGTECH_LANGUAGE or
C:\Program Files\cgtech\x.x.x\windows64\ Esprit\language
CGTECH_INSTALL is set to the top level folder where VERICUT is installed. In the
above table, x.x.x represents the VERICUT release number. For VERICUT 7.1.4 the
environment variable would be set to C:\Program Files\cgtech\7.1.4.
CGTECH_PRODUCTS is set to the folder for the specific operating system of the
computer running VERICUT: either "windows" or "windows64". For a typical
VERICUT 7.1.4 installation this variable is set to C:\Program Files\cgtech\7.1.4\windows
or C:\Program Files\cgtech\7.1.4\windows64.
LSHOST is set to the name of the license server computer.
CGTECH_LANGUAGE is used to specify the \path\ to the folder containing the Esprit-
to-VERICUT Interface language file (EspritRes.local) that you want to use.
Use the Microsoft Windows Control Panel > System > System Properties: Advanced
tab, Environment Variables feature to define these environment variables. See
Microsoft Windows Help for more information.
License
At the time that the ESPRIT-to-VERICUT Interface is launched for the first time, it tries
to connect with license server. License server name can be specified by environmental
variables LSHOST or LSFORCEHOST.
If neither of these two environment variables is defined, the window shown below will
display, enabling you to specify the license server name manually. The Name specified
will be saved for future use, so that you only have to define the license server name once.
94
Installing CGTech Products
Language
At the time that the “VericutAddin.dll” is loaded with ESPRIT CAM system, the
ESPRIT-to-VERICUT Interface looks for CGTECH_LANGUAGE environment
variable. If it is defined, the interface loads the “EspritRes.local” file found at that
location.
If the CGTECH_LANGUAGE environment variable is not set, then the ESPRIT-to-
VERICUT Interface looks for the CGTECH_LOCALE environment variable to get the
location of the language file.
If the CGTECH_LOCALE environment variable is not defined, the ESPRIT–to-
VERICUT Interface will look for the “EspritRes.local” file in the folder where
“VericutAddin.dll” is located, in a subfolder named the same as the language that you
want to use.
If the location of the language file is not found in any of these places, English will be
used as the application language. Also, if the “EspritRes.local” file for specified language
is not found, English will be used as the application language.
Initially the ESPRIT-to-VERICUT Interface will look for the environment variable
CGTECH_PRODUCTS. If it is defined, then execution continues, otherwise the
following window displays, enabling you to specify the location of the “commands”
folder of your VERICUT installation. Enter the \path\ to the “commands” folder of your
VERICUT installation in the VERICUT Command Path: text field or use the
(Browse) icon to display a directory selection window and use it to specify the \path\ to
the “commands” folder.
For example, “C:\Program Files\cgtech\7.2\windows64\commands”.
95
Installing CGTech Products
Based on the path that you provide, the value for CGTECH_PRODUCTS is determined.
You only need to specify the path the first time that the ESPRIT-to-VERICUT Interface
is used. The value of CGTECH_PRODUCTS will be saved for future use.
The location of the VERICUT installation will be retrieved from the
CGTECH_INSTALL environment variable, if defined, or will be determined from the
value of CGTECH_PRODUCTS.
If either of these variables remains undefined, the ESPRIT-to-VERICUT Interface will
not load up.
96
Installing CGTech Products
Troubleshooting
If there is no entry for the VERICUT Interface in the available add-ins list, there is most
likely a problem with registering the Interface.
97
Installing CGTech Products
For a typical VERICUT installation, these files are located in the C:\Program
Files\CGTech\7.2\windows\GibbsV\ or C:\Program
Files\CGTech\7.2\windows64\GibbsV\ folder . x.x.x represents the VERICUT release
number. For VERICUT 7.1.6 the x.x.x would be 7.1.6.
The GibbsV.dll file should be placed in the GibbsCAM plugins directory (for example,
C:\Program Files\Gibbs\GibbsCAM\8.0.19_NLO\plugins\.
The localization file should be left in the \GibbsV\ directory of your VERICUT
installation directory.
98
Installing CGTech Products
LSHOST server_name
CGTECH_PRODUCTS is set to the folder for the specific operating system of the
computer running VERICUT: either "windows" or "windows64". In the above table, x.x.x
represents the VERICUT release number. For a typical VERICUT 7.2 installation this
variable is set to C:\Program Files\cgtech\7.2\windows or C:\Program
Files\cgtech\7.2\windows64.
LSHOST is set to the name of the license server computer.
Use the Microsoft Windows Control Panel > System Properties: Advanced tab,
Environment Variables feature to define these environment variables. See Microsoft
Windows Help for more information.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the GibbsCAM-to-VERICUT Interface. For
complete details on using the GibbsCAM-to-VERICUT Interface, see GibbsCAM-to-
VERICUT Interface (GibbsV), in the CAD/CAM Interfaces section of Converters and
CAD/CAM Interfaces, located in the CGTech Help Library.
99
Installing CGTech Products
NOTE: MCAMV requires the installation of the Microsoft C++ run time environment.
This is not distributed automatically by Microsoft. A copy of the installer is on the
VERICUT CD, or at:
http://download.vericut.net/downloads/redistributables.zip
Administrator privileges are required to install this.
You do not need this if you have Microsoft Visual Studio C++ 2005 installed (not likely
for most VERICUT users).
Configuration
The VERICUT C-Hook is for Mastercam Xv. It is distributed as four files located in the
C:\Program Files\cgtech\x.x.x\windows\mcamv\Xv\ or C:\Program
Files\cgtech\x.x.x\windows64\mcamv\Xv\ directory of your VERICUT installation. The
x.x.x represents the VERICUT release number. For VERICUT 7.1.4 the x.x.x would be
7.1.4. The v represents the Mastercam version number. For Mastercam X5, v would be 5.
NOTE: Please be aware that with MCAMV X6 there are now 32bit and 64bit specific
versions. Make sure you use the correct version.
A 32 bit MasterCAM X6 requires a 32 bit MCAMV Interface dll
A 64 bit MasterCAM X6 requires a 64 bit MCAMV Interface dll
They are NOT interchangeable.
100
Installing CGTech Products
The two .dll files and the .ft file should be placed in Mastercam's "chooks" folder, which
is one level down from the Mastercam installation folder (for example
C:\McamX\chooks). The file mcRes.local should be placed in the Mastercam installation
folder.
To enable the C-Hook to find VERICUT, you also need to define three environment
variables, CGTECH_INSTALL, CGTECH_PRODUCTS and LSHOST.
For example;
C:\Program Files\cgtech\x.x.x\windows
CGTECH_PRODUCTS or
C:\Program Files\cgtech\x.x.x\windows64
LSHOST server_name
CGTECH_INSTALL is set to the top level folder where VERICUT is installed. In the
above table, x.x.x represents the VERICUT release number. For a typical VERICUT 7.2
installation the environment variable would be set to C:\Program Files\cgtech\7.2.
CGTECH_PRODUCTS is set to the folder for the specific operating system of the
computer running VERICUT: either "windows" or "windows64". For a typical
VERICUT 7.2 installation this variable is set to C:\Program Files\cgtech\7.2\windows or
C:\Program Files\cgtech\7.2\windows64.
LSHOST is set to the name of the license server computer.
Use the Microsoft Windows Control Panel > System Properties: Advanced tab,
Environment Variables feature to define these environment variables. See Microsoft
Windows Help for more information.
Access
To trigger the Net-Hook while in Mastercam, hold down the Alt key and click the C key
(referred to as Alt-C). Alternatively, you could select Settings > Run User Application.
You will see a file selection dialog offering all the installed C-Hooks. Pick
VERICUT.dll and click on the Open button.
101
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the Mastercam-to-VERICUT Interface. For
complete details on using the Mastercam-to-VERICUT Interface, see Mastercam-to-
VERICUT Interface (MCAMV), in the CAD/CAM Interfaces section of Converters
and CAD/CAM Interfaces, located in the CGTech Help Library.
102
Installing CGTech Products
This section documents supported versions of NX, and the procedure for configuring the
NX-to-VERICUT Interface (NXV). These instructions apply only when VERICUT will
be run via NXV. If VERICUT will only be run outside of NX, then ignore this section.
NX version support
NXV can be operated on Windows computers with NX versions NX5, NX6, NX7,
NX7.5 and NX8.
VERICUT Interfaces for old Unigraphics versions (V16, V17, V18, NX, NX2, NX3, and
NX4) are no longer distributed with the VERICUT installation. You can copy the old
interface files forward from a previous installation, or contact VERICUT technical
support for the older Unigraphics interface files.
Upward compatibility of the old interfaces is not tested with this release and not
guaranteed. However nothing is intentionally changed to prevent them from continuing to
work.
Configuration
Follow the general procedure below to configure NXV. Integrating NXV into your
standard UG startup may require "root" or administrator permissions - see your system
administrator for assistance.
NOTE: The following NX products, ufunc_execute (P2_ufunc_execute for NX2,
product name "UG/Open API Execute") and the grip_execute (product name "UG/Open
Grip Execute") are required for NXV.
Assuming NX is installed, install VERICUT (includes the NXV software) per the
VERICUT installation instructions.
Windows
1. Locate the NXV batch file for your version of NX
Look in VERICUT’s 'commands' folder (C:\Program
Files\cgtech\x.x.x\platform\commands\ directory of your VERICUT installation.
The x.x.x represents the VERICUT release number. For VERICUT 7.2 the x.x.x
would be 7.2. The platform represents windows, or windows64) for the batch file
named ugv_nxV.bat (where V represents the NX version, i.e. ugv_nx2.bat,
ugv_nx3.bat, etc). The batch file sets the environment for NXV, then runs NX
using %UGII_ROOT_DIR%\UGII.BAT.
103
Installing CGTech Products
NOTE: If you need a batch file for a newer/higher version of NX use the
highest nxV.bat available in the folder. The interfaces are usually upward
compatible with newer versions of NX.
NOTE: The NXV batch file will NOT work correctly from its location in the
VERICUT’s ‘commands’ folder because users usually do not have write
permissions there. You must either create a desktop shortcut with a start-in path
where you have write permissions, or copy the batch file to a directory where you
have permission to write files.
104
Installing CGTech Products
You can change VERICUT’s default settings by modifying ug_init.Vc Project (or
ug_initm.VcProject). We recommend you save a backup copy of these files before
modifying them. The files are located in the "library" folder in your VERICUT
installation.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the NX-to-VERICUT Interface. For complete
details on using the NX-to-VERICUT Interface, see NX-to-VERICUT Interface
(NXV), in the CAD/CAM Interfaces section of Converters and CAD/CAM Interfaces,
located in the CGTech Help Library.
105
Installing CGTech Products
Overview
Teamcenter (formerly IMAN and UG Manager) is a Product Lifecycle Management
(PLM) application that manages NX data files. When using the NX-to-VERICUT
Interface (NXV), it is necessary to modify the NX Teamcenter environment in order for
NXV to operate correctly.
NXV uses Teamcenter functions for reading data and writing files when running within
Teamcenter. For example:
• If Teamcenter is not used, NXV asks NX to write VERICUT model files to the
path specified in the NXV interface.
• If Teamcenter is used, NXV asks Teamcenter to ask NX to write model files.
Teamcenter then places the files in a "temporary" Teamcenter folder.
NXV detects when it is running within Teamcenter and uses Teamcenter data
management functions when requesting and writing data.
All VERICUT files for the current session are placed by Teamcenter in the "temporary"
Teamcenter folder for the current checked-out project. At the end of the NX session,
Teamcenter prompts the user to check the files in.
VERICUT files are considered, "meta-data" by Teamcenter. "meta data" is data with
unknown content, but the files are controlled by Teamcenter.
106
Installing CGTech Products
2. Call the NXV batch file (as modified in step 1) from the Teamcenter startup
script. The call must be inserted above the command that launches NX. Calling
the NXV batch file sets the environment for NXV and VERICUT from the
Teamcenter startup script. This edit is usually done by the Teamcenter site
administrator.
Example lines to add to a Teamcenter startup batch file that uses Windows batch
file syntax:
set CGTECH_INSTALL=C:\cgtech70
call "%CGTECH_INSTALL%\windows\commands\NX2"
NOTE: The above example is for a Windows batch file. The syntax is different
for a perl or UNIX Teamcenter startup script, however the concept is the same.
@echo off
rem setlocal
call "%CGTECH_PRODUCTS%\commands\cgtenv"
107
Installing CGTech Products
set CGTECH_CLASSES=%CGTECH_INSTALL%\classes
if "%CGTECH_LIBRARY%" == "" set
CGTECH_LIBRARY=%CGTECH_INSTALL%\library\
if "%CGTECH_LICENSE%" == "" set
CGTECH_LICENSE=%CGTECH_PRODUCTS%\license
if "%TEMP%" == "" set TEMP=C:\TEMP
if "%TMP%" == "" set TMP=C:\TEMP
if "%CGTECH_LOCALE%" == "" set CGTECH_LOCALE=english
set CGTECH_LANGUAGE=%CGTECH_CLASSES%\%CGTECH_LOCALE%
set CGTECH_HELP=%CGTECH_INSTALL%\hhelp
set CGTECH_SAMPLES=%CGTECH_INSTALL%\samples\
set CGTECH_TRAINING=%CGTECH_INSTALL%\training\
set CGTECH_DEFAULT_UNITS=INCH
set CGTECH_RGB_TXT=%CGTECH_PRODUCTS%\vericut\rgbhues.txt
if "%CGTECH_JRE%" == "" set CGTECH_JRE=%CGTECH_PRODUCTS%\jre
set
path=%CGTECH_PRODUCTS%\vericut;%CGTECH_PRODUCTS%\license;%PATH%
set waitopt=
set argstr=
if test%1==test goto cgtchkend
if %1==BATCH set waitopt=/wait
if %1==batch set waitopt=/wait
if %1==BATCHP set waitopt=/wait
if %1==batchp set waitopt=/wait
set argstr=%1
shift
:cgtgetarg
if test%1==test goto cgtchkend
if %1==BATCH set waitopt=/wait
if %1==batch set waitopt=/wait
if %1==BATCHP set waitopt=/wait
if %1==batchp set waitopt=/wait
set argstr=%argstr% %1
shift
goto cgtgetarg
:cgtchkend
set UGII_VENDOR_DIR=%CGTECH_PRODUCTS%\nx\nx7.5
rem "%UGII_ROOT_DIR%\UGII.BAT" %argstr%
:end_cgtech
rem endlocal
108
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the NX-to-VERICUT Interface. For complete
details on using the NX-to-VERICUT Interface, see NX-to-VERICUT Interface
(NXV), in the CAD/CAM Interfaces section of Converters and CAD/CAM Interfaces,
located in the CGTech Help Library.
109
Installing CGTech Products
Follow the following steps to enable using the NX-to-VERICUT Interface (NXV) when
starting NX from Start > All Programs > Siemens NX x.x > NX x.x, where x.x is the
NX version number.
The CGTech software installation procedure places the files required by NXV in a sub-
folder. If you elected to install the software in the default folder "C:\Program
Files\cgtech\x.x.x" (where x.x.x is the VERICUT release number), then for VERICUT
7.2, the NXV folder will be "C:\Program Files\cgtech\7.2\windows\nx" or "C:\Program
Files\cgtech\7.2\windows64\nx".
110
Installing CGTech Products
To enable NX to find VERICUT, you also need to define two environment variables,
CGTECH_PRODUCTS and CGTECH_INSTALL.
For example;
C:\Program Files\cgtech\x.x.x\windows\
CGTECH_PRODUCTS or
C:\Program Files\cgtech\x.x.x\windows64\
CGTECH_INSTALL is set to the top level folder where VERICUT is installed. In the
above table, x.x.x represents the VERICUT release number. For a typical VERICUT 7.2
installation the environment variable would be set to C:\Program Files\cgtech\7.2
CGTECH_PRODUCTS is set to the folder for the specific operating system of the
computer running VERICUT: either "windows" or "windows64". In the above table, x.x.x
represents the VERICUT release number. For a typical VERICUT 7.2 installation this
variable is set to C:\Program Files\cgtech\7.2\windows \windows or C:\Program
Files\cgtech\7.2\windows \windows64.
Use the Microsoft Windows Control Panel > System Properties: Advanced tab,
Environment Variables feature to define these environment variables. See Microsoft
Windows Help for more information.
111
Installing CGTech Products
Installation
The Pro/E-to-VERICUT Interface is distributed as twenty files located in the
C:\Program Files\cgtech\x.x.x\windows\proev\WFyy\ or the
C:\Program Files\cgtech\x.x.x\windows64\proev\WFyy\ directory of your VERICUT
installation. The x.x.x represents the VERICUT release number, for example 7.1.6. The
yy represents the PTC version number, for example 40 for Wildfire 4.0 or 50 for CREO
Elements/Pro 5.0.
The following files are located in the \proev\WFyy\ directory of your VERICUT
installation.
cgtproev.dll (application dll)
ProevChinese.local (localization file)
ProevEnglish.local (localization file)
ProevFrench.local (localization file)
ProevGerman.local (localization file)
ProevItalian.local (localization file)
ProevJapanese.local (localization file)
protk.dat (registry file)
cl_cancel.bif
proev_db_design_page.res
proev_db_file_page.res
proev_db_fixture_page.res
proev_db_main_page.res
proev_db_ops_page.res
proev_db_options_page.res
proev_db_process_page.res
proev_db_settings_page.res
proev_db_stock_page.res
Vericut16.gif
112
Installing CGTech Products
At startup, Pro/ENGINEER will look for the registry file, protk.dat, to get location
information about the other files used by the Pro/E-to-VERICUT Interface.
The protk.dat file contains the following information:
name cgtproev
startup dll
exec_file <full path, including the file name, where the cgtproev.dll is located>
text_dir <full directory path to the directory, where the proev.txt file is located>
revision Wildfire
end
3. Edit the protk.dat file to point to the locations of the cgtproev.dll and the
proev.txt file.
The protk.dat file specifies the location of the cgtproev.dll file and the proev.txt file.
Edit exec_file so that it points to the \proev\WFyy\cgtproev.dll of your VERICUT
installation. Edit text_dir so that it points to the \proev\WFyy\text directory of your
VERICUT installation. The protk.dat file should look similar to the following after
editing:
name cgtproev
startup dll
exec_file C:\Program Files\cgtech\x.x.x\windows\proev\WFyy\cgtproev.dll
text_dir C:\Program Files\cgtech\x.x.x\windows\proev\WFyy\text
revision Wildfire
end
where x.x.x is the VERICUT version number and yy is the Pro/E Wildfire version
number. \windows\ could be \windows64\ depending on whether you are running a 32
bit or 64 bit computer.
The proev.txt file contains the resource text for the VERICUT option which shows up
in Pro/ENGINEER under the "Applications" menu. The VERICUT option is the entry
point for launching the Pro/E-to-VERICUT Interface.
The proev.txt file contains the following information:
PROEV_VERICUT_BUTTON_LABEL
VERICUT...
PROEV_VERICUT_BUTTON_HELP
Invoke the VERICUT Interface
113
Installing CGTech Products
For example;
Environment Variable
Variable Value
Name
C:\Program Files\cgtech\x.x.x\windows\proev\WFyy\
Proev[language].local
PROEV_LANGUAGE or
C:\Program Files\cgtech\x.x.x\windows64\proev\WFyy\
Proev[language].local
C:\Program Files\cgtech\x.x.x\windows
CGTECH_PRODUCTS or
C:\Program Files\cgtech\x.x.x\windows64
LSHOST server_name
In the above examples, x..x.x is the VERICUT release number and yy is the WildFire
version number
PROEV_LANGUAGE is used to specify the path/filename of the PROEV language
file (Proev[language].local) that you want to use.
CGTECH_PRODUCTS is used to specify the folder, for the specific operating
system, of the VERICUT installation: either "windows" or "windows64". In the
above table, x.x.x represents the VERICUT release number. For a typical VERICUT
7.2 installation this variable is set to C:\Program Files\cgtech\7.2\windows or
C:\Program Files\cgtech\7.2\windows64.
LSHOST is set to the name of the license server computer.
CGTECH_LIBRARY is used to specify the folder, where VERICUT library
machine and control files are located. In the above table, x.x.x represents the
VERICUT release number. For a typical VERICUT 7.2 installation this variable is set
114
Installing CGTech Products
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
You should now be ready to start using the Pro/E-to-VERICUT Interface. For complete
details on using the Pro/E-to-VERICUT Interface, see Pro/E-to-VERICUT Interface
115
Installing CGTech Products
116
Installing CGTech Products
VERICUT connects to the TDM Systems tool management database using a Dynamic
Link Library (DLL) supplied by TDM Systems. It is mandatory to use the DLL supplied
with your specific TDM installation since the DLL is both specific to the TDM version
and to the Oracle database version.
Copy the TDMAPI.dll from your TDM installation into the …\windows\vericut folder
of your VERICUT installation (for example, C:\Program
Files\cgtech\x.x.x\windows\vericut, where x.x.x is the VERICUT release number, for
example 7.2). An optional VERICUT license from CGTech is required in order for
VERICUT to access tool data that resides in the TDM Oracle database. Once the license
and DLL are in place VERICUT’s TDM Systems Interface can then be invoked from the
Tool Manager > File menu.
Creation of VERICUT tool information in the TDM database requires custom
configuration services from TDM Systems, and an optional license from TDM Systems
to enable creation of tool data for VERICUT.
The TDM configuration and installation instructions are part of the TDM install
documents provided by TDM Systems.
117
Installing CGTech Products
The Model Interface modules (CATIA V4 Model Interface, CATIA V5 Model Interface,
STEP Model Interface, and ACIS Model Interface) enable VERICUT to both read and,
when combined with Model Export, write the designated model file formats. These
modules do not require a CAD/CAM system be available for VERICUT to read or write
any of the formats. The modules are available for both Windows 32 bit, and Windows 64
bit platforms. Each module is licensed separately.
Model interfaces are installed from a separate installer executable (not part of the
VERICUT installer). The Model Interface installer is available for download from
CGTech’s website, and it is also distributed on the VERICUT 7.2 DVD. To download the
model interface installer appropriate for your current VERICUT installation:
1. Click on the appropriate link below to start the download of the model interface
installer for your VERICUT version:
http://download.vericut.net/downloads/model_interfaces_v711.zip
http://download.vericut.net/downloads/model_interfaces_v712.zip
http://download.vericut.net/downloads/model_interfaces_v714.zip
http://download.vericut.net/downloads/model_interfaces_v715.zip
http://download.vericut.net/downloads/model_interfaces_v716.zip
http://download.vericut.net/downloads/model_interfaces_v72.zip
2. Unzip the model_interfaces_vx.x.x.zip file (where x.x.x is the VERICUT release
number) to extract the install.exe.
NOTES:
1. You may need to have the latest Microsoft Windows updates installed (as of
August 14, 2009) for the CAD Model Interfaces to work correctly.
2. If you get the following error message "Error loading ACIS libraries!", try
installing the Microsoft redistributable C++ run-time libraries. See the Install
Microsoft redistributable C++ Run-Time Libraries topic above for additional
information. You must have Administrator privileges to do the install.
118
Installing CGTech Products
VERICUT's CAD Model Interface modules should now be available if you are licensed
to use them.
If errors occur, visit the VERICUT Users' Forum or contact CGTech technical support
via our website, just click on the support link.
119