0% found this document useful (0 votes)
52 views1 page

Fisa Tehnica Cablu FTP Cu Sufa CAT6

This document provides specifications for a Category 6 F/UTP PE cable with messenger wire. The cable consists of 4 twisted pairs of soft copper wire insulated with HDPE and surrounded by an aluminum foil shield, ripcord, and UV-protected PE jacket. It is designed for outdoor aerial installation for frequencies up to 250MHz, with temperature operating ranges of -50°C to +60°C. Electrical and transmission test results are provided to show the cable meets Category 6 specifications.

Uploaded by

Eugen Creasta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views1 page

Fisa Tehnica Cablu FTP Cu Sufa CAT6

This document provides specifications for a Category 6 F/UTP PE cable with messenger wire. The cable consists of 4 twisted pairs of soft copper wire insulated with HDPE and surrounded by an aluminum foil shield, ripcord, and UV-protected PE jacket. It is designed for outdoor aerial installation for frequencies up to 250MHz, with temperature operating ranges of -50°C to +60°C. Electrical and transmission test results are provided to show the cable meets Category 6 specifications.

Uploaded by

Eugen Creasta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Category 6 F/UTP PE with Messenger Fca Cable

P/N: 7934120

DESIGN
1) Conductor: soft copper wire Ø 0,54 mm
2) Insulation: HDPE, Ø 1,07 mm
3) Pair: two conductors twisted together
Color identification of pairs:
pair 1: white-blue / blue
pair 2: white-orange / orange
pair 3: white-green / green
pair 4: white-brown / brown
4) Core wrapping
5) Aluminum contact wire Ø 0,5 mm
6) Core shield: aluminum polymer foil (metal outside)
7) Rip-cord
8) Messenger: steel wire Ø 1,20 mm
9) Jacket: UV-protected PE, thickness 0,7 mm, nom. size 7,1x9,7 mm
APPLICATION INSTALLATION AND OPERATION CONDITIONS
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, For outdoor aerial installation in conditions of high electromagnetic im-
100VG-AnyLAN, Token Ring 16/100 Mbit/s, Fast Ethernet (100BASE-TX), pacts. Operated on frequencies up to 250 MHz
1000BASE-T, 2.5GBASE-T, 5GBASE-T, PoE, PoE+, PoE++

СOMPLIANCE WITH THE REQUIREMENTS MECHANICAL CHARACTERISTICS


Cabling: ISO/IEC 11801-1 Temperature range:
Cable: IEC 61156-5  During installation -10 °C ... +60 °C
CPR euro-class: Fca  After installation -50 °C ... +60 °C
Bending radius:
 During installation ≥ 10 cable diameters
 After installation ≥ 4 cable diameters
Tensile stress: ≤ 1200 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter Unit Value
Capacitance pF/m ≤ 56
Direct current resistance Оhm/100 m ≤ 8,5
Insulation resistance GOhm/km ≥5
Resistance unbalance % 2
NVP % 68
Propagation delay ns/100 m ≤ 534+36/√f
Delay skew on the frequency 100 MHz ns/100 m ≤ 30
Characteristic impedance in the frequency range of:
1-100 MHz Ohm 100±15
100-250 MHz 100±22
Test voltage between cores, (DC, 2 s) kV 2,5

TRANSMISSION CHARACTERISTICS AT 20 °C (80 M)


Frequency, MHz 1 4 10 16 20 31,25 62,5 100 250
Attenuation, dB, max 2,1 3,8 6 7,6 8,5 10,8 15,5 19,9 33
NEXT, dB, min 75,3 66,3 60,3 57,3 55,8 52,8 48,3 45,3 39,3
PS NEXT, dB, min 72,3 63,3 57,3 54,3 52,8 49,8 45,3 42,3 36,3
ELFEXT, dB, min 68 56 48 44 42 38 32 28 20
PS ELFEXT, dB, min 65 53 45 41 39 35 29 25 17
RL, dB, min 20,0 23,0 25,0 25,0 25,0 23,6 21,5 20,1 17,3
IEC 61156-5, values lower than 4 MHz are given for information only

ORDER INFORMATION
P/N Cable name Standard packing Weight, kg/km
7934120 KPPEt-VP (250) 4х2х0,54 (F/UTP-cat.6) Plywood reel 305 m 58,8