Services, Wärtsilä Finland Oy
Section Valid for Ref. Date Issue Document No. Page
11 Connecting rod W46F WFI-S 28-May-2012 01 4611V015 1(1)
Installation name: Engine No: Engine ref. type: W46F
Engine type: Application: Ambient temp: °C Fuel type: Engine rhrs:
Big end bearing bore
Connecting rod screws must be tightened before measuring.
Hydraulic pressure when tightening: - M52 screws 2250 bar
- M45 screws 1600 bar
Tightening order: M52 first. (See engine manual.)
Nominal diameter without shells: mm
Maximum allowed difference between Dmax and Dmin: 0.14 mm
Reference diameter (mm): 439 mm
Measurement tool(s) id: Measurement tools(s) S/N:
Deviations to be given in 1/100 mm
Bank: Cylinder number
1 2 3 4 5 6 7 8 9 10
L
D1
R
L
D2
R
L
D3
R
L
D4
R
L
D5
R
Max. dev:
Running hours:
ID No:
Temp. (°C):
Remarks:
Date of measurement: Place: Name:
Wärtsilä Finland Oy P.O. Box 252 (Tarhaajantie 2) Telecop. +358 10 709 1847 Tel. +358 10 709 0000 Business ID 0773744-3
Services, Vaasa FIN-65101 Vaasa, Finland Telecop. +358 10 709 1380 Registered Office: Vaasa
Wärtsilä Finland Oy P.O. Box 50 (Stålarminkatu 45) Telecop. +358 10 709 3279 Tel. +358 10 709 0000
Services, Turku FIN-20811 Turku, Finland Telecop. +358 10 709 3410