0% found this document useful (0 votes)
55 views

Switch Disconnector

This document provides information on switch disconnectors in the S6R DC series for sizes up to 400A at 1500Vdc. It lists accessories available including direct and external handles, auxiliary contacts, and shaft extensions. Shaft dimensions and part codes are provided for standard and extended shafts.

Uploaded by

Ricardo Cessa
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views

Switch Disconnector

This document provides information on switch disconnectors in the S6R DC series for sizes up to 400A at 1500Vdc. It lists accessories available including direct and external handles, auxiliary contacts, and shaft extensions. Shaft dimensions and part codes are provided for standard and extended shafts.

Uploaded by

Ricardo Cessa
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Annex V

Switch Disconnector
SWITCH - DISCONNECTORS O-I SWITCH - DISCONNECTORS O-I

Size 1
S6000R DC A 400
S6R DC

S6R DC
Switch - disconnector
series

series
Accessories
1500 Vdc
base mounting 1P - 2P
Direct handle Auxiliary contacts
CODE  DS-SI11 1NO+1NC  CODE  D5LAU01
2NO+2NC  CODE  D5LAU02
Ie = 16 A (resistive loads)
4 A (inductive loads) at 250 Vac.

External handle  included shaft * (e1)

Shafts
IP65 
 UL50E/NEMA 250
Types: 1, 3R, 4, 4X y 12 L
CODE  DS-SA11
Standard shaft included *(e1)
L (mm) P (mm)
P 227 185... 336
CODE - 2P  CODE - 1P 
400 A S6R0400 _ _ D0 400 A S6R0400 _ _ D0 Shaft extensions
Type 1
L (mm) P (mm) CODE
2’ 2’ 1’ 375 185... 486 DS-EP14
DOWN
1’ 1’ 1’
DOWN BC CB DOWN D4 4D DOWN Type 2
2 2 1 L (mm) P (mm) CODE
UP UP UP UP
536 185... 647 DS-EP15
1 1 1
1’

1’
DOWN F4 4F DOWN
1
UP UP
1

28 ,5
ø5

Dimensions (mm) ø 3 4

Technical information
Door drilling for external handle

40
Según IEC 60947-1
IEC 60947-3
400 400
Rated thermal current in ambient at 70º C Ith A 400 Short - circuit behaviour
Rated insulation voltage (DC) Ui V 1500 Rated short-circuit making capacity *(2) Icm kA (peak) 10
Rated dielectric strength 50 Hz., 1 min. V 5000 Rated short-time withstand current (1sec) Icw kA rms 10
Rated impulse withstand voltage Uimp kV 12 Conditional short - circuit current *(3) kA rms 100
Rated operational current *(1) Ie 1500 Vdc DC21B A 400 Mechanical features
max 166 1
Minimum number of mechanical operations *(4) Cycles 8000 225
172 min 13
205
* Other voltages and / or utilization categories. Please consult
(1)
102 4
98 107 205
*(2) Without limiting protective device (short-circuit maintained 50... 100 ms.) 30 45 4
*(3) With limiting protective device which set a limit to peak value short-circuit making
capacity and maximum power dissipation to indicated values
*(4) Please consult us for more operations

217
193
170
157

217
10
ø5 2

45
,5
2,5 45 4 27
ø1 115

12
102 4 45
150
171,5

S max H max L max


M
(Cu) (Cu) (Cu)
mm2 mm mm Nxm
240 7 35 M10 18