Ekr1500 Operating-Manual CCD-Camera 01 en
Ekr1500 Operating-Manual CCD-Camera 01 en
EKR 1500
with CCD 30000 or
CCD 5000 from hardware version M
Translation of the
Original Operating Manual
Attention
Comments of this type have to be taken into consideration to protect the operator
against mechanical risks
Caution
press key
LED ‘OFF’
LED blinking
0.0
Table of contents
Table of contents
Chapter 1 Despription
1.1 General
1.2 General plan
1.3 Operating elements
1.4 Signification of the keys on the front panel
1.5 Signification of the LED’s on the front panel
1.6 Safety instructions
1.7 Emissions
Chapter 3 Transport/Storage
Chapter 4 Mounting/Installation
4.1 Location requirements
4.2 Installation
4.3 Mounting plan
4.4 Installation CCD 30000 / CCD 5000M
4.5 Installation of EMC-wiring
Chapter 5 Start-up
5.1 Start-up requirements
5.2 Start-up
5.3 Basic SET UP
5.4 Determine desired sense of rotation for manual operation
5.5 Adjustment of cameras
5.6 Start-up of automatic operation with sensor 1 (and possibly sensor 2)
5.7 Electric powered actuators
5.8 Hydraulic powered actuators
5.9 Special indications Mastersetup
5.10 Reset to manufacturers settings
Chapter 6 Operation
6.1 Amplifier
6.2 Set point scaling when change over the web edge
6.3 Status indications
6.4 Operation with BST eltromat interface
Chapter 9 Maintenance
9.1 Amplifier EKR 1500
9.2 Camera CCD 30000 / CCD 5000M
9.3 Hydraulic powered actuator with plunger coil regulator
9.4 Electric motor powered actuator
Chapter 10 De-commissioning
Enclosure: Annex 1 Connecting plan EKR 1500 with cameras CCD 30000 / CCD 5000M
Annex 2 General plan EKR 1500 with 1x CCD 30000 / CCD 5000M
Annex 3 General plan EKR 1500 with 2x CCD 30000 / CCD 5000M
1. Description
1.1 General
The EKR 1500 system is a microprocessor-controlled amplifier.
With the CCD-cameras 30000 and 5000M this amplifier could be used for:
The amplifier has PLC-compatible inputs and also an ‘OK-relay’ with NO and NC contact.
Full integration into the machine control system via:
- I-O Module potential-free in- and outputs for extended PLC messages and
commands
- Intercon-Module direct, serial connection for integration of system results,
messages and commands into the machine control system.
- Interbus-S Module direct connection to Interbus-S Module as remote bus station
- Profibus-DP module for instantaneous communication with locally peripheral
equipment
Notice: Please find the connection plans of the nominated modules at the corresponding
operating instructions.
- If system locking is desired (e. g., in case of machine stop), this can be achieved
by means of external contacts or signals from the PLC.
2 7
8 20 21 9
key and/or combination of keys function
AUTO (1) + SET UP (6) = release of gain with the keys (4) and (5)
The blinking of LED’s AUTO (1) , MAN (2) , S-C (3) , SET UP (6) or LED- arrays 10 – 14
and/or 15 - 19 indicate a fault message.
Simultaneously, the OK-relay is switched-off. (see also chapt. 8)
LED-No. 10, 14,15 and 19 (red) signalize the limits of the measuring band of the sensors.
LED-No. 11, 13, 16 and 18 (green) signalize the admissible measuring band of the sensors.
LED-No. 12 and 17 (green) signalize the center of the measuring band of the sensors.
additional indications of the LED's for gain and shifting of the guiding point see point 6.1.3 and
point 6.3.
10 11 12 13 14 15 16 17 18 19
Installation of the BST eltromat equipment into the production machine according to the relevant
rules ( EN 294, EN 349) and the specific branch-oriented regulations for prevention of accidents,
such as:
- Installation of connecting cables between amplifier and controller and/or edge sensor
stumple-free, nontension and well anchored.
- Take care of free headroom. If the free passage is limited, respective building components
have to be stuffed and painted in yellow/black.
Please do not open the unit until the line voltage is switched off!
When operation at open unit is necessary, only protection class IP20 is present.
There will be an increased risk of danger by line voltage !
During functional testing outside of production machine and/or during the start-up
procedure the actuator will carry-out positioning movements!
Make relevant safety arrangements during performance check !
During start-up procedure, the total safety concept of the production machine will have
to be considered.
1.7 Emissions
The A-rated equivalent continuous sound level of the equipment is lower than 70 dB(A).
2. Technical Data
2.1 EKR 1500
Line voltage: 115V/230V +10% / -20% 50-60Hz
Fuses: 115V 1A T
230V 0,5A T
Supply to accessories
± 12V (min.± 11,4V), at max. 50mA
+ 24V non regulated supply, max. 0,4A
Ri = 4,7 kOhm
active (1) > 8V
not active (0) < 4V
analogue inputs (see also chapter 5, point 5.1 and connecting plan
2x 0...+ 5V or 0...+ 10V, individual adjustable
2x ± 9,75V or 0...+ 9,75V, individual adjustable
2x ± 11,75V
1x NAMUR adaption with output ± 11,75V
Protection class: IP 54
Power consumption: 3W
CCD 5000M/ 50, CCD 30000/ 50: CCD 5000M/ 28, CCD 30000/ 28:
= 35° = 60°
M D distance M D distance
setting setting
330 515 0,60 m 220 200 0,20 m
470 715 0,80 m 480 400 0,50 m
600 915 1,00 m 720 600 0,60 m
940 1415 1,50 m 960 800 0,80 m
1960 2915 3,00 m 1190 1000 1,00 m
1800 1500 1,50 m
3. Transport/storage
Depending upon the order, delivery will be carried out:
4. Mounting / Installation
4.1 Location requirements
The amplifier has to be installed at dry, vibration-free area.
4.2 Installation
Mounting plan see point 4.3
19
1 - Open terminal
compartment
A U T O Pull the two rear
mounting rails upward
150
S E T E UN P T E R
M A N
S E N S S O E R N S
L EO F R T R I G H T
214
S - BC D R A I G R HK T
25
6 264 115
276
10
EO F
E
R T
T
R
E
I
UN
G H
P T
T
E R
upper edge of the
housing.
S - BC D R A I G R HK T
S - BC D R A I G R H K T
262
180
M4 or Ø 5
131
Up to a maximum of three cameras CCD 30000 / CCD 5000M can be connected to one amplifier.
A combination with a CCD 2004 camera and/or an Analog Interface module is possible.
Attention! The use of a CCD 30000 camera and a CCD 5000 camera within the same
system is forbidden.
4.4.2 Installation
Attention! Includes a guiding system more than one CCD 30000 / CCD 5000M, the connecting
plugs of the cameras must be mounted in the same direction.
Connecting plug of camera 1 must point to the outside.
Switch off line voltage before pin up or pull off the connecting plug.
CCD CCD
camera 1 camera 2
Web
scanning direction
transition bright/dark dark/bright
black rubber
sealing-
parts conical sealing
(metal/rubber)
figure 1 figure 2
vanished shield
figure 3 figure 4
ferrite core
figure 5 figure 6
5. Start-up
EPROM
Prozessor RAM
TRAFO
S1.1
S1.2
S1.3
S T U V W X S1.4
S1.5
JX12 JX13 JX14 S1.6
I S1.7 H1
H J K L M N Z S1.8 H2
Y S2.1 H3
JX8 JX9 S2.2 H4 A
H11 S2.3 H5 B JX11
115V: F1= 1AT F1 S2.4 H6 C
230V: F1= 0,5AT OK 44454647495051525354555657585960616263646566676869707172737475 S2.5 H7 D
O S2.6 H8 E JX10
P 404142 0 6 7 8 9 1011 0 1314151617182021222425262829313233343536373839 S2.7 H10 H9 F
L N R Relais S2.8
S1.6 = ON = chase and follow system with CCD 5000 / CCD 30000
ON ON hydraulic actuator
lifting of zero level OFF
Dither ON
The DIL switches S2.1 and S2.2 are used to adjust the fundamental gain of the amplifier according
to the application.
LED H11 indicates the correct function of the relay 'system ok' (LED is lighting).
LED extinguishes if a failure occurs (see also chapter 8 'Trouble shooting').
The amplifier (standard version with electric motor powered actuator) is preset by manufacturer
as follows:
Make sure that the voltage on the name plate of the amplifier corresponds to the actual supply
voltage! Correct in case of deviation.
230V
EPROM
F1 = 0,5AT
Prozessor RAM
TRAFO
S1.1
S1.2
S1.3
S T U V W X S1.4
S1.5
JX12 JX13 JX14 S1.6
I S1.7 H1
H J K L M N Z S1.8 H2
Y S2.1 H3
JX8 JX9 S2.2 H4 A
H11 S2.3 H5 B JX11
115V: F1= 1AT F1 S2.4 H6 C
230V: F1= 0,5AT OK 44454647495051525354555657585960616263646566676869707172737475 S2.5 H7 D
O S2.6 H8 E JX10
P 404142 0 6 7 8 9 1011 0 1314151617182021222425262829313233343536373839 S2.7 H10 H9 F
L N R Relais S2.8
F1 = 1AT
After switching on line voltage (usually “power on“ on the amplifier) the LED array of the CCD
camera is displayed as a running array.
About one second after all LEDs are lit, the camera address given by the connection appears for
a short time.
LED 10 LED 1
SET UP
LED
10 9 8 7 6 5 4 3 2 1
running LED array after switching
on the amplifier
About one second after all LEDs are lit, one of the following combinations of indication appears.
camera 1 with camera 2
existing in the guiding system
camera 2
camera 1 without camera 2
existing in the guiding system
camera 3
= LED on = LED off
5.2 Start-up
SET UP
If the guiding device with connected servo-center switch is in center position or if no servo-center
switch is connected, the guiding device will be displaced automatically for a short moment in
order to check whether a servo-center switch is connected.
ENTER
The CCD 30000 / CCD 5000M cameras are preset on edge scanning by nontransparent material in
processing of transmitted light with a HF fluorescent lamp.
5.5 Adjustment of cameras (to be carried out only once at the first start-up)
5.5.1 Basic adjustment of camera 1
SET UP
2) at the amplifier:
The LED array of the CCD 30000 / CCD 5000M is switched to the indication 'Special
indications Mastersetup' and the first parameter selection 'Indication exposure time' is
activated.
LED 10 LED 1
SET UP
Set the diaphragm of the CCD 30000 / CCD 5000M to the value 11.
The indication of the exposure time occurs by means of the LEDs.
The allocation is shown in the schedule on the next page.
For adjustment of additional parameters, if necessary, see chapter 5.9 'Special indications
Mastersetup'.
LED 10 LED 1
SET UP
LED
10 9 8 7 6 5 4 3 2 1 exposure time in ms
o o o o o o o ≤1
o o o o o o o o ≤2
o o o o o o o ≤3
o o o o o o o o ≤4
o o o o o o o ≤5
o o o o o o o o ≤6
o o o o o o o ≤7
o o o o o o o o ≤8
o o o o o o o ≤9
o o o o o o o o ≤ 10
o o o o o o o ≤ 15
o o o o o o o o ≤ 20
o o o o o o o ≤ 30
o o o o o o o o ≤ 40
o o o o o o o ≤ 50
o o o o o o o o ≤ 60
o = LED off
= LED on
= LED blinker
standard value
3) Adjustment of diaphragm
a) The camera has to adjusted on the HF fluorescent lamp and/or on the lightened band, that if
possible a minimum of LEDs will be lighten
b) If the LEDs indicates no reaction, this procedure has to be repeat again with a larger
diaphragm opening.
c) Does only one LED or no LED lighten, lower diaphragm and repeat adjustment of the camera
4) Adjust camera parallel to the HF fluorescent lamp (fixing of the viewing range)
fluorescent lamp
fluorescent lamp
fixed
viewing range
fluorescent lamp
Screw in (-) or
screw out (+) the
adjusting screw X Test of the scanning position compared
to the luminous band / fluorescent lamp
position of the
dark/bright transition alignment correction
correct
to adjust
Fluorescent lamp
Attention: Only connect and remove connecting cables to the CCD camera that are not live.
SETUP
6) On the amplifier
press the 'SETUP' and 'PLUS' keys.
+
The basic set-up is switched on.
The LED array of the CCD 30000 / CCD 5000M is switched to the display ‘special display
master set-up’’ and the first parameter selection of ‘display exposure period‘ is activated.
LED 10 LED 1
SET UP
Adjust the diaphragm of the CCD 30000 / CCD 5000M to the value 11.
The LED’s show the exposure time. You can see the relationship between exposure time and
the appropriate LED display from the table on page 7
7) Align the camera parallel to the fluorescent lamp / to the luminous field (Y-direction).
fluorescent lamp /
luminous field
Align the camera to produce a brightness profile as per (a) by screwing in or screwing out the
adjustment screw (Y-direction).
luminous field or
fluorescent lamp
correct no
The exposure time should be adjusted to 2 – 3 ms. Open or close the diaphragm of the camera
lens accordingly. The oscilloscope shows the following image:
exposure time
2) Cover the optics completely and press the key on the camera.
The blinking of the LED’s will be interrupted for some seconds.
Comment:
You may have to press the key on the camera a second time before the LED’s start blinking
again.
SETUP
3) When the LEDs are blinking again
press key ‘ENTER’ at the EKR.
4) Push in nontransparent material (e.g. paper) into the viewing range of the camera.
The web edge will be displayed at the LED array of the camera.
Attention: Only one edge of material may be within the viewing range of the camera,
material b
fluorescent lamp distance a = distance b
Press key 'SET UP' on the camera until the parameter 'Indication focus value' will be shown
(LED 2 is blinking in addition to LED 10).
Push in a well defined contrast into the measuring range of the camera and adjust the focus to a
minimum
LED 10 LED 1
SET UP
LED
10 9 8 7 6 5 4 3 2 1 Number of pixels necessary for
contrast threshold
O O O O O O O O ≤1
O O O O O O O ≤2
O O O O O O O O ≤3
O O O O O O O ≤4
O O O O O O O O ≤5
O O O O O O O ≤6
O O O O O O O O ≤7
O O O O O O O ≤8
O O O O O O O O ≤9
O O O O O O O ≤ 10
O O O O O O O O ≤ 11
O O O O O O O ≤ 12
O O O O O O O O ≤ 13
O O O O O O O ≤ 14
O O O O O O O O ≤ 15
O O O O O O O ≤ 16
O O O O O O O O ≤ 17
= LED blinking O = LED off = LED on
Place the guard ring again!
SET UP
for leaving the compensation without change
1) Remove the material out of the viewing range , that the camera only recognize the HF
fluorescent lamp. If working in the vertical illumination, the visible surface has to be covered by
an even white dull material (e.g. poster board).
simultaneously. +
Three LED blocks appear in the display of the camera at short intervals after one another with
three switched on LED´s. The automatic white balance is following!
Afterwards the LED 1 to 10 are blinking again.
If the actuator guides the material out of the viewing range, DIL switch S 1.1 has to be switched
over.
If the type of the web material requires reversion of the guiding direction, this happens
automatically during the material-SET UP.
2) Press key ‘SET UP’. SET UP The LED´s at the amplifier (LED 10 - 19)
reverse automatically and indicates the value
of gain.
3) Increase gain with key ‘PLUS’, until the guiding device starts
oscillating. The ‘light spot’ of LED indication at the amplifier
moves from LED 10 to LED 19.
( LED 19 = maximum of gain, we encouraged to leave the
maximum of gain, if there is non oscillating)
ENTER
Press key ‘S-C’. The servo component must move towards the center
and stop there. If the servo component is moving into
the final position, exchange the connections 25 and 26.
Attention: If using an analog servo-center transducer (CK 37, BI 5 G....) preselect their
adjustment of gain.
Procedure:
SE T U P
LED indication at EKR 1500 switch over
and indicate the value of gain.
ENTER
4) Press key ‘ENTER’.
Attention! During the start-up the actuator will carry out positioning movements!
The machine must be protected against danger of injury according to the
relevant rules and regulations!
Limit switches for limitation of the regulating distance (stroke) can be used only with electric
motor powered actuators.
The motor is switched off when reaching the end of stroke by means of an alarm contact of the limit
switch. The output will be switched off by a software program.
The motor will be switched off without cutout.
When reaching the end of stroke, the LED on the controller corresponding to the mode of operation
selected (AUTO, S-C or MAN) will start blinking.
When activating the opposite direction the alarm message will reset automatically.
When using a Power Module the alarm message “thermal protection active“ will be generated by
the alarm signal “both limit switches activated“. The output will then be switched off.
The alarm message will keep up also after ‘power off’.
The alarm message can only be reset by pressing the key “ENTER“ at the commander.
Also by adjustment of DIL switches, carry out a zero point adjustment when using an electrical-
hydraulic guiding unit with plunger coil regulator.
Procedure:
Attention: Dither amplitudes are significant for output setting ± 300mA only.
X = not relevant
0 = „low“ Uinlow: min. -30V, max. +4V
1 = „high“ Uinhigh: min. +8V, max. +35V
S1.2 S2.5
ON OFF lifting of zero level ON
Dither ON
ON ON lifting of zero level OFF
Dither ON
S1.2 = “ON“
S1.5 = “OFF“
Set jumper “B“
Set jumper “D-E“
LED 10 LED 1
SET UP
LED
10 9 8 7 6 5 4 3 2 1 signification
Signalizes Special indication
? ? ? ? ? ? ? ? ? Mastersetup activated
Selection of parameters
Indication exposure time
O O O O O O O O (basic adjustment)
O = LED off
= LED blinking
? = depends on the actual parameter value
The trigger threshold of the first contrast transition will be indicated in general
(gray scale value 0-255).
LED 10 LED 1
SET UP
LED
10 9 8 7 6 5 4 3 2 1 Trigger threshold A
O O O O O O O O ≤ 25
O O O O O O O ≤ 30
O O O O O O O O ≤ 35
O O O O O O O ≤ 40
O O O O O O O O ≤ 45
O O O O O O O ≤ 50
O O O O O O O O ≤ 60
O O O O O O O ≤ 70
O O O O O O O O ≤ 80
O O O O O O O ≤ 90
O O O O O O O O ≤ 100
O O O O O O O ≤ 125
O O O O O O O O ≤ 150
O O O O O O O ≤ 175
O O O O O O O O ≤ 200
O O O O O O O ≤ 255
Attention: The reset to manufacturers settings may be carried out after start-up and correct
addressing of the cameras (camera 1/2/3).
Any preceding adjustments will be overruled!
6. Operation
The system only admits operation with
the components actually present!
6.1 Amplifier
Function key and control symbols on the front panel
Automatic
Manual positioning
Adjustment of gain
In operation mode 'AUTO' with switched off SET UP a shifting of the guiding point for the
activated sensing mode is possible via arrow keys (4) and (5).
Attention: SET UP must be switched off. After each SET Up the set value will
be deleted automatically.
set point
center range
set point
limit 1
set point
limit 2
LED ON
LED OFF
The possible shifting of guiding point is max. 80% and/or. +/- 40% from the
max. viewing range of the sensors.
Note: If the ‘remote precision adjustment EFE 1’ is connected, the shifting of guiding point will
be occurred only via EFE 1.
Key ‘PLUS’ and ‘MINUS’ are then out of function!
6.2 Set point scaling when change over the web edge
The actual position of web edge or web center-line can be taken over as set point for guiding by
means of scaling the set point before switch on the guiding to edge 1, edge 2 or center-line guiding.
That means, the web will be guided accurate at this position.
So it is possible to switch over from center-line guiding to web edge guiding without displacement of
the web.
Condition: This function is only available with one or two cameras CCD 5000 guiding to edge 1,
edge2 or center-line guiding.
This function can't be activated when camera CCD 5000 is sensor 3. It is only possible
to take over a position within the range F.
Is the position outside of range F, the nearest position possible is taken over.
F = 80%
Procedure:
The set point scaling can be carried out for 'guiding to edge 1', 'guiding to edge 2' and 'center line
guiding'. A separate adjustment has to be done for the different guiding modes.
You can continue to change the set point by hand after set point scaling.
LED 10 LED 1
SET UP
scanning direction
LED
10 9 8 7 6 5 4 3 2 1 signification
O O O O O O bright line
(e.g. web center with incident light)
O = LED off
= LED on
= LED blinking
7. Remote control
Truth table for the remote control inputs EKR 1500 (e.g. activation by PLC):
32 33 34 35 36 37 72 70 71 73
Function
Automatic X 1 0 X X 0 X X X X
Manual X 0 0 X X 1 X X X X
X 1 0 X X 1 X X X X
X X 1 X X 1 X X X X
Controller lock-out 1 X X X X X X X X X
External SET UP X 1 1 X X 0 X X X X
Interface conditions:
Attention: Please ensure, that terminals 33 / 34 are locked-out against each other
when switching from AUTO to Servo-Center.
8. Trouble shooting
8.1 Indications on the EKR 1500
When an error is detected, the relay „System OK“ falls off. When pressing
ENTER
Note: key the error message is switched off, and the relay “System OK“
is re-energized, provided that no further error is present.
After basic SET UP Faulty ‘Basic SET UP’ was Repeat ‘Basic SET UP’ according
all LED`s are blinking carried. to point 5.3.
LEDs at the EKR 1500 are During set point scaling the web Bring web edge back into the
blinking as follows: edge was recognized outside permissible measuring range.
the valid measuring range (appr. Error message will be cleared
or 80% of the measuring range). automatically.
LED 10 LED 1
SET UP
LED
10 9 8 7 6 5 4 3 2 1 message
lighting error during white
O O O O O O
balance (without contrast)
lighting error during white
O O O O
balance (overexposed)
O O O O O O O O O EEPROM error
Lighting error during white Maximum exposure time is reached. Check alignment camera /
balance (without contrast) (black balance was carried out). fluorescent lamp.
Check fluorescent lamp.
Check diaphragm.
Remove protection cap.
Repeat start-up of the camera.
Lighting error during white Minimum exposure time is reached. Check fluorescent lamp.
balance (overexposed) Check diaphragm.
Repeat start-up of the camera.
EEPROM error EEPROM values are not correct. Carry out white balance and
Camera is not ready for operation. Setup.
Carry out parameterization again
if the camera has been
parameterized via interface.
9. Maintenance
9.1 Amplifier EKR 1500
The amplifier is maintainance-free.
The cleaning of the keyboard should be carry out with a dry, clean and smooth cloth.
By high contamination, use for cleaning a usual liquid cleaner, benzine or spirit.
10. De-commissioning
De-commissioning (scrapping) of the guiding system must carry out only together with the complete
unit. The procedure used has to be defined by the OEM.
Regarding the guiding equipment, please bear in mind that mainly electric/electronic components
are involved. The disposal of which is subject to the relevant legal rules and regulations.
A taking back of the equipment by BST eltromat International GmbH is possible.
Please reach the necessary agreements.
Limit switch 2
EMS6
Limit switch 1
If the functional direction of the EFE 1 External keyboard
remote control (right/left) shall be reversed, EKR 3000
remote the connections at the terminals 20 and 21
Commander
control have to be interchanged.
The signal direction of the tachometer generator has to be adapted
to the direction of rotation of the motor. Therefore switch over the Servo center components
amplifier to mode “MAN“. Press one of the arrow keys. Additional
If the actuator is moving to the end of the guiding device, interchange module bus
the terminals 65 and 66. subscriber’s
station
OMG 4
Sensors
R1 = 680 Ω / 0,3 W
MD.066.01.A02 / 19.09.2002
Annex 2 General plan EKR 1500 with 1x CCD 30000 / CCD 5000M
Servo-center component
CK 37 Oscillation
BI5G OZ 3
HF fluorescent lamp
Actuators
EMS 1 / EMS 10 / EMS 16
EMS 6
EMS 5
EH-St 9/3
~3
MD.066.01.01 / 05.11.99
Annex 3 General plan EKR 1500 with 2x CCD 30000 / CCD 5000M
Interface
Remote control (see separate manual)
Servo-center component
BI5G OZ 3
HF fluorescent lamp
Actuators
EMS 1 / EMS 10 / EMS 16
EMS 6
EMS 5
EH-St 9/3
~3
MD.066.01.01 / 05.11.99
Start-up of the Actuator EMS 17 / EMS18
Connected to EKR 1500 / EKR 1000 / CCD Line Guider
S1.2 = OFF
S1.5 = OFF
2. Setup
1. Move the guiding device to the desired final position via one of
the arrow keys. The final position limits the guiding movement
in this direction.
3. Move the guiding device to the desired final position via the
other arrow key. The final position limits the guiding movement
in this direction.
ENTER
4. Press key ‘ENTER‘. The final position is stored.
The adjustment of gain for the S-C transducer must be set depend-
ing on the application if necessary.
3. Electrical Connection
29 white
EKR 1000 28 brown
EKR 1500 26 yellow
25 pink EMS 17
CCD Line Guider 24 grey
38 green
29 green + pink
EKR 1000 28 brown + grey
EKR 1500 26 blue
25 white EMS 18
CCD Line Guider 24 red
38 yellow