0% found this document useful (0 votes)
237 views7 pages

Configuracion ME4012

The document contains configuration and status information for a storage array with two controllers. Each controller has four host ports and connectivity to 11 disks. The controllers and other components are operating normally with the latest firmware versions installed. All host ports are currently disconnected from switches or hosts.

Uploaded by

haflores2512
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
237 views7 pages

Configuracion ME4012

The document contains configuration and status information for a storage array with two controllers. Each controller has four host ports and connectivity to 11 disks. The controllers and other components are operating normally with the latest firmware versions installed. All host ports are currently disconnected from switches or hosts.

Uploaded by

haflores2512
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 7

WWN: 500C0FF0F0F02F3C 500C0FF0F0F02F3C

Controller ID: A
Serial Number: CN0MJ9W5FCG009720MXUA00
Hardware Version: 6.0
CPLD Version: 3.9
MAC Address: 00:C0:FF:50:30:AF
WWNN: 208000C0FFF0F02F
IP Address: 192.168.7.201
IP Subnet Mask: 255.255.255.0
IP Gateway: 192.168.7.1

Controller ID: B
Serial Number: CN0MJ9W5FCG009720MY1A00
Hardware Version: 6.0
CPLD Version: 3.9
MAC Address: 00:C0:FF:50:31:96
WWNN: 208000C0FFF0F02F
IP Address: 192.168.7.202
IP Subnet Mask: 255.255.255.0
IP Gateway: 192.168.7.1

A0 FC(-) 207000c0fff0f02f

A1 FC(-) 217000c0fff0f02f

A2 FC(-) 227000c0fff0f02f

A3 FC(-) 237000c0fff0f02f

B0 FC(-) 247000c0fff0f02f

B1 FC(-) 257000c0fff0f02f

B2 FC(-) 267000c0fff0f02f

B3 FC(-) 277000c0fff0f02f

# show conf
Management Controller is refreshing stale data. Please wait...
Waiting for system to finish computing health...
System Information
------------------
System Name: SRVSTORAGE-2
System Contact: Noel Vargas
System Location: Centro de Datos DICEGSA
System Information: SAN-2
Midplane Serial Number: 00C0FFF0F02F
Vendor Name: DELL EMC
Product ID: ME4012
Product Brand:
SCSI Vendor ID: DellEMC
SCSI Product ID: ME4
Enclosure Count: 1
Health: OK
Health Reason:
Other MC Status: Operational
PFU Status: Idle
Supported Locales: English (English), Spanish (espa�ol), French (fran�ais), German
(Deutsch), Japanese (???), Korean (???), Chinese-Simplified (????)

Controllers -----------
Controller ID: A
Serial Number: CN0MJ9W5FCG009720MXUA00
Hardware Version: 6.0
CPLD Version: 3.9
MAC Address: 00:C0:FF:50:30:AF
WWNN: 208000C0FFF0F02F
IP Address: 192.168.7.201
IP Subnet Mask: 255.255.255.0
IP Gateway: 192.168.7.1
IP6 Link Local: fe80::2c0:ffff:fe50:30af/128
IP6 Link Local GW: ::
IP6 Auto Address: ::/0
IP6 Auto Address Source: DHCPv6
IP6 Auto Gateway:
Disks: 11
Virtual Pools: 0
Disk Groups: 0
System Cache Memory (MB): 8192
Host Ports: 4
Disk Channels: 2
Disk Bus Type: SAS
Status: Operational Failed Over to This Controller: No
Fail Over Reason: Not applicable
Multi-core: Enabled
Health: OK
Health Reason:
Health Recommendation:
Position: Top
Phy Isolation: Enabled
Controller Redundancy Mode: Active-Active ULP
Controller Redundancy Status: Redundant

Controllers
-----------
Controller ID: B
Serial Number: CN0MJ9W5FCG009720MY1A00
Hardware Version: 6.0
CPLD Version: 3.9
MAC Address: 00:C0:FF:50:31:96
WWNN: 208000C0FFF0F02F
IP Address: 192.168.7.202
IP Subnet Mask: 255.255.255.0
IP Gateway: 192.168.7.1
IP6 Link Local: ::/0 IP6 Link Local GW: ::
IP6 Auto Address: ::/0
IP6 Auto Address Source: DHCPv6
IP6 Auto Gateway:
Disks: 11
Virtual Pools: 0
Disk Groups: 0
System Cache Memory (MB): 8192
Host Ports: 4
Disk Channels: 2
Disk Bus Type: SAS
Status: Operational
Failed Over to This Controller: No
Fail Over Reason: Not applicable
Multi-core: Enabled
Health: OK
Health Reason:
Health Recommendation:
Position: Bottom
Phy Isolation: Enabled
Controller Redundancy Mode: Active-Active ULP
Controller Redundancy Status: Redundant

Controller A Versions Controller B Versions


---------------------
---------------------
Storage Controller CPU Type: Broadwell 2200MHz Broadwell
2200MHz
Bundle Version: GT275R005-04 GT275R005-
04
Base Bundle Version: G275 G275
Build Date: Wed Dec 12 13:53:01 MST 2018 Wed Dec 12
13:53:01 MST 2018
Storage Controller Code Version: GTS275R09-01 GTS275R09-
01
Storage Controller Code Baselevel: GTS275R09-01 GTS275R09-
01
FU Version: 6.29.27348x 6.29.27348x
Storage Controller Loader Code Version: 29.015 29.015
CAPI Version: 3.21 3.21
Management Controller Code Version: GXM275R017-01 GXM275R017

Management Controller Base Version: GXM275 GXM275


Expander Controller Code Version: 523B 523B
CPLD Code Version: 3.9 3.9
Hardware Version: 6.0 6.0
Host Interface Module Version: 11 11
Host Interface Module Model: 6 6
Backplane Type: 7 7
Host Interface Hardware (Chip) Version: 2 2
Disk Interface Hardware (Chip) Version: 2 2
SC Boot Memory Reference Code Version: 0.3.2.16 0.3.2.16

CTK Version:
GXM275DellOEM GXM275DellOEM

FRU Versions
------------
Enclosure ID: 0

Midplane Versions
-----------------
VPD Format Version: 13
VPD CRC: 82041A40
Config Mismatch Version: 00
CPLD Version: 14
FRU Descriptor: 10
Part Number: 0992957-07
Midplane Serial Number: SGFTJ1927F0F02F

Name Location Ctlr


Firmware Version Firmware Version (full) VPD Format Version VPD CRC
CFG Format Version CFG CRC Boot Loader Version CPLD Version
------------------------------------------------------------------------
Root Expander-A Enclosure 0, Iom A A

06 4C7D0269
01 C4BE3273 010B 0309
Root Expander-B Enclosure 0, Iom B B
523B 0502003B 06 4C7D0269
01 C4BE3273 010B 0309

PSU Versions PSU Versions


------------ ------------
Name: PSU 0, Left PSU 1, Right
Firmware Version: 033D 033D
PSU DSP version: 030A 030A
VPD Format Version: 05 05
VPD CRC: 3CFCE593 3CFCE593
FRU Descriptor: FC FC
Part Number: 1001661-07 1001661-07
Power Supply Serial Number: PMF1001661G137V PMF1001661G16GP

Ports Media Target ID Status Speed(A) Speed(C) Health


Reason
Action
-------------------------------------------------------------------------------
A0 FC(-) 207000c0fff0f02f Disconnected Auto N/A
There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems.

Topo(C) PID SFP Status Part Number Supported Speeds


------------------------------------------------------------------
Auto N/A OK FTLF8529P3BCV 4G,8G,16G

A1 FC(-) 217000c0fff0f02f Disconnected Auto N/A


There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems

Topo(C) PID SFP Status Part Number Supported Speeds


------------------------------------------------------------------
Auto N/A OK FTLF8529P3BCV 4G,8G,16G

A2 FC(-) 227000c0fff0f02f Disconnected Auto N/A


There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems
.

Topo(C) PID SFP Status Part Number Supported Speeds


------------------------------------------------------------------
Auto N/A Not present N/A

A3 FC(-) 237000c0fff0f02f Disconnected Auto N/A


There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems

Topo(C) PID SFP Status Part Number Supported Speeds


------------------------------------------------------------------
PTP N/A Not present N/A

-------------------------------------------------------------------------------
Ports Media Target ID Status Speed(A) Speed(C) Health
Reason
Action

-------------------------------------------------------------------------------
B0 FC(-) 247000c0fff0f02f Disconnected Auto N/A
There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems.

Topo(C) PID SFP Status Part Number Supported Speeds


--------------------------
Auto N/A OK FTLF8529P3BCV 4G,8G,16G

B1 FC(-) 257000c0fff0f02f Disconnected Auto N/A


There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems.

Topo(C) PID SFP Status Part Number Supported Speeds


------------------------------------------------------------------
Auto N/A OK FTLF8529P3BCV 4G,8G,16G

B2 FC(-) 267000c0fff0f02f Disconnected Auto N/A


There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems.

Number Supported Speeds


------------------------------------------------------------------
Auto N/A Not present N/A
B3 FC(-) 277000c0fff0f02f Disconnected Auto N/A
There is no active connection to this host port.
- If this host port is intentionally unused, no action is required.
- Otherwise, use an appropriate interface cable to connect this host port to a
switch or host.
- If a cable is connected, check the cable and the switch or host for problems.

Topo(C) PID SFP Status Part Number Supported Speeds


------------------------------------------------------------------
Auto N/A Not present N/A

-------------------------------------------------------------------------------
Location URL Serial Number Vendor Rev Description Usage
Jobs Speed (kr/min) Size Sec Fmt Disk Group Pool Tier
Health
------------------------------------------------------------------------------
0.0 49Q0A01DTNUF TOSHIBA B01C SSD SAS AVAIL
0 1920.3GB 512e Performance

0 1920.3GB 512e Performance


OK
0.1 49Q0A01FTNUF TOSHIBA B01C SSD SAS AVAIL
0 1920.3GB 512e Performance
OK
0.2 49Q0A01ETNUF TOSHIBA B01C SSD SAS AVAIL
0 1920.3GB 512e Performance
OK
0.3 49Q0A01CTNUF TOSHIBA B01C SSD SAS AVAIL
0 1920.3GB 512e Performance
OK
0.4 WBM1JYWS SEAGATE ST53 SAS AVAIL
10 2400.4GB 512e Standard
OK
0.5 WBM1H3F9 SEAGATE ST53 SAS AVAIL
10 2400.4GB 512e Standard
OK
0.6 WBM1K6T3 SEAGATE ST53 SAS AVAIL
10 2400.4GB 512e Standard
OK
0.7 WBM1JNEE SEAGATE ST53 SAS AVAIL
10 2400.4GB 512e Standard
OK
0.8 WBM1JNNF SEAGATE ST53 SAS AVAIL
10 2400.4GB 512e Standard
OK
0.10 WBM1HKL2 SEAGATE ST53 SAS AVAIL
10 2400.4GB 512e Standard
OK
------------------------------------------------------------------------------
Status Encl Slot Vendor Model Serial Number
Size
---------------------------------------------------------------------------
Up 0 0 TOSHIBA KPM5XRUG1T92 49Q0A01DTNUF
1920.3GB
Up 0 1 TOSHIBA KPM5XRUG1T92 49Q0A01FTNUF
1920.3GB
Up 0 2 TOSHIBA KPM5XRUG1T92 49Q0A01ETNUF
1920.3GB
Up 0 3 TOSHIBA KPM5XRUG1T92 49Q0A01CTNUF
1920.3GB
Up 0 4 SEAGATE DL2400MM0159 WBM1JYWS
2400.4GB
Up 0 5 SEAGATE DL2400MM0159 WBM1H3F9

You might also like