0% found this document useful (0 votes)
112 views4 pages

Elmeasure Branch Circuit Monitor Catalog

This document describes and compares two branch circuit monitors: the PN 8700M and EL-Tag. The PN 8700M is a high-end monitor that measures voltage, current, power quality events, harmonics, and energy import/export. It provides comprehensive energy management through high/low recording, demand forecasting, and load profiling capabilities. The EL-Tag is a compact and cost-effective monitor that can be installed on multiple circuits to measure voltage, current, power, energy use, and THD for individual circuit monitoring and billing applications.

Uploaded by

SEO BDM
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views4 pages

Elmeasure Branch Circuit Monitor Catalog

This document describes and compares two branch circuit monitors: the PN 8700M and EL-Tag. The PN 8700M is a high-end monitor that measures voltage, current, power quality events, harmonics, and energy import/export. It provides comprehensive energy management through high/low recording, demand forecasting, and load profiling capabilities. The EL-Tag is a compact and cost-effective monitor that can be installed on multiple circuits to measure voltage, current, power, energy use, and THD for individual circuit monitoring and billing applications.

Uploaded by

SEO BDM
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

EL-TAG

EL-TAG BRANCH CIRCUIT


MONITOR
Multifunction Meter | Demand Monitor | Import Export | Harmonics |
Power Quality

HIGH-END BRANCH CIRCUIT MONITOR FOR


COMPREHENSIVE ENERGY MANAGEMENT!

Features of PN 8700M Features of EL-Tag


High / Low recording VLL, VLN, A, Hz, W, VA, PF, VAR value storage with True RMS measurements
time stamp Simultaneous sampling of Volts & Amps
Accuracy Class 1, 0.5s optional User programmable password protection
Voltage measurement up to 600 VLL Supports both with Display and without display (ET5730 and ET5030)
Multi-channel data collection
Display Basic, Power, Energy, Demand for both Import and Export
parameters Accuracy class 1.0
Compact 193x39x27mm (LxWxH) dimension
Simultaneous sampling of Voltage and Current,
Direct measurement up to 63A Pass through
Programmable PT & CT ratio
Attachable to any MCB (for same Brand MCB)
User programmable Password Protection Stand alone with Din rail Mounting and RS 485
Measures THD and Individual harmonics up to 63rd order with a Neutral current Measurements and configurable phase selection through
sampling rate of 512 samples / cycle RS485
Captures and measures power quality events: K factor, Crest factor, Auto learning of Phases or Neutral. (CT polarity to be maintained).
Sag / Swell, Interruption and Unbalance in accordance with EN 50160 Measures VLL, VLN, A, W, VA, PF and Wh
Representation of waveforms for instantaneous V, I, Sag / Swell, Voltage Displays Basic, Power and Energy parameters - optional
and current harmonics histogram for PN 8700 THD voltage & current measurement for all channels
Records events such as Sag / Swell for voltage with the time stamp in 3 Phase, 3 channels or Single phase 9 channels
1s duration Pluggable up to 12 making 3 phase 36 channels or single phase 108
CO2 emission, ON Hrs, Power Interruptions channels
Max demand 4 high / 4 low, 12am snapshot, 31st day snapshot Space saving of one MCB width, 1/4th MCB length per channel
Demand update every second to forecast VA, W & VAR accurately Space saving compact design for easy installation into existing panel boards
Installation of 10 sec per channels
Programmable starting current in % of 5A secondary. Default 10mA
Energy resetting @ 99999999 kVAh x MF.
Programmable Auto scrolling time - 1 sec. to 10 sec. (Default 5 sec.)
Dual source sensing (ET 5720)
Programmable Energy format - Counter based or Resolution based
Phase wise Voltage Sag & Swell Wave Forms
LCD 8 parameter display at a time, 8 Digits energy Applications :
Power save mode with Enable/Disable option For remote reading and control, the Eltag is supported by ELNet Software,
Byte order option - Field Programmable Float / Little Endian / Big Endian designed for remote setup and data viewing and analysis
data format Building Management System: With the open modbus protocol, the Eltag
High / Low recording VLL, VLN, A, Hz, W, VA, PF, VAR value storage with can interface any system, such as building management, HMI etc
time stamp
Compact : Ideal for Data Center
Energy resetting at 99999999 kVAh x MF.
Ideal for apartments / commercial complexes billing and load pattern study
OLD register to store previously cleared Energy & Load hours
on individual phase
Individual phase kWh measurement provides user flexibility of measuring 3
phase 3 channels or single phase 9 channels
Primary current can be independently configured making it ideal for any
kind of industry or upgradation

Note: Additional error of 0.1% of full scale, for meter input current below 500mA for 5A setting
Schematic Diagram

A/C Load LMS Data Center Motor/ Pumps


Load
Benefits
Reduce Your Panel size by 50%
Save upto 30% cost
Retrofit made simple
Installation by 1/10th of conventional method
Self /Auto configuration by single click for all 108 device
PN 8710

Built in Data storage for one month

elmeasure.com
Product Selection:
PN 8700M ET 5030 ET 5730 ET 5720
ACCURACY OPTION Graphical LCD No Display With Display DS With Display
CLASS 1.0
Class 0.5S / Class0.2S
BASIC PARAMETERS
V12, V23, V31 * * *
V, V1, V2, V3 *
A, A1 ,A2, A3 *
Hz *
Angle V & A, RPM
Unbalance V & A
POWER PARAMETERS
W, W1, W2, W3 *
VA, VA1,VA2,VA3 * * *
PF, PF1,PF2,PF3 *
VAR, VAR1,VAR2,VAR3
POWER QUALITY PARAMETERS
THD - Voltage and Current upto 63rd * 15th 15th 15th
Individual Harmonics upto 63rd
K Factor, Crest Factor
High Low - Instantaneous
High Low - Last Minute *
Voltage Sag, Swell & Interruptions
Power cycles
TEHD and TOHD
Power THD and TDD
INTEGRATED PARAMETERS
Wh *
Vah * * *
VARh -Ind
VARh-Cap
Load Hours * * *
Phase Energy and Load hours * * * *
RD(IE)
Wh- Total and Net
VAh- Total and Net
VARh - Total and Net
ON hours
CO2 Emission
Bar graph ( % Load)
Volt squared hours
Amp squared hours
TOD PARAMETERS
TOD Demand - Import
TOD Energy - Import and Export
DEMAND PARAMETERS
Rising Demand (Sliding/Block - Programmable)
Forecast demand
Maximum demand
Demand Profile 4High & 4 Low *
ADDITIONAL FEATURES
12am & 31st day snap shot *
Data Logger - 1MB *
Load Efficiency *
Energy Trends *
Dynamic communication *
Dual Source *
COMMUNICATION
RS485 (MODBUS)

* *
Note: Default - Optional -
Default Optional
in communication only in communication only

elmeasure.com
Technical Specification:
PN8700M EL-Tag
GENERAL CHARACTERISTICS
Display type LCD 4 row, 7/8 Parameter
Instantaneous Digits
Integrated Digits 4 5 / no display
Sensing / Measurement True RMS, 1 Sec update time, 4 Quadrant Power & Energy True RMS, 1 Sec update time.
2 Quadrant Power & Energy.
Rated voltage 50-600 VLL
Rated current 10mA - 6A 10mA-6A, 50mA – 32A, 100mA – 63A
Frequency 45 - 65Hz
Poles description 1P + N, 3P, 3P + N 3 phase 3 channel
Sampling rate 512 samples / cycle 64 samples / cycle
Measured Accuracy Class Class 1 as per IEC 62053-21 / Class 0.5 / Class 1: IEC 62053-21 (Default)
Class 0.2S as per IEC 62053-22 (Optional). Class 0.5: IEC 62053-22 (Optional).
Programmable Setting 110 or 415V LL Nominal & Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase
Permissible overload 120%, Burden: 0.2VA per phase
External Fuse Rating 200mA No fuse
CT PT Ratio Max 2000MVA Programmable
Auxiliary supply 80-300V AC / DC Self Powered
Power consumption 4VA nominal
Data update rate 1 Sec.

COMMUNICATION
Device ID & Parity 1 to 247 & Odd, Even, None (Preferred Even)
Protocol & Interface Modbus. RTU, RS 485, TCPIP (Optional Wifi) RS 485 for stand alone
Baud rate 9600 bps to 38400 bps (Preferred 9600 bps)
Isolation 2000 volts AC isolation for 1 minute between communication & other circuits

ENVIRONMENTAL CHARACTERISTICS
Operating temperature -10°C to + 55°C (14°F - 131°F)
Storage temperature -25°C to +70°C (-13°F - 158°F)
Humidity 5% to 95% non-condensing
Altitude Below 2000mts
Measurement Category CAT III
Pollution degree 2 (As per IEC 61010)

PROTECTION CLASS
Ingress protection IP 51 ( IP 54 front facia optional ) & Double Insulation ( As per IEC 61010-1)

ELECTROMAGNETIC COMPATIBILITY
Electrostatic discharge IEC 61000-4-2
Immunity to Electromagnetic IEC 61000-4-3
RF Fields
Conducted Immunity IEC 61000-4-6
Immunity to Magnetic Fields IEC 61000-4-8
Immunity to voltage dips and IEC 61000-4-11
interruptions
Fast transient IEC 61000-4-4
Immunity to surge waves IEC 61000-4-5
Conducted and Radiated CISPR- 22
emissions

SAFETY AND STANDARDS


Construction IEC/EN 61010-1 ed.3, CAT III, 300 V LN / 600 V LL , Protection class II.
Standards UL 61010-1, IEC/EN 62052-11

MECHANICAL CHARACTERISTICS
Weight Unpacked 350 gms. Packed 450 gms. (It may vary based on optional features) 200 gms
Torque 1 N-m (For 5A) 0.4 N-m
Wire gauge 11 AWG (For 5A) 26 - 10AWG (4.0mm2) – Voltage and
Communication
Mechanical Specification: Current Transformers:

90-0+2
96
90

46 25

90-0+2
Hang on CT-
5A or 50A or 100A or 200A Up to 100A, 16mm ID 1A - 1000A (ID: 800MM)
90
96 193

35

57

Clip on
CT-5A | 50A | 100A | 250A Split Core CT-100A | 400A | 1000A 5A - 3000A (ID: 400MM)

elmeasure.com
BM

BRANCH CIRCUIT
MONITOR
Multi Channel Load Manager | Power Distribution Unit/System

COMPACT DEVICE TO ENROUTE


MULTIPLE CHANNELS!

Features : Technical Specification:


Multi-channel data collection Specification Description
3 Phase, 4 channels or Single phase 12 channels Accuracy: Class 1.0 (Default) as per IEC 62053-21,
Displays Basic, Power and Energy parameters Class 0.5 as per IEC 62053-22 (Optional).
Optional Pluggable Ethernet (Default RS 485) Sensing/ 1:600
Space saving compact design for easy installation into existing panel Measurement:
boards Sensing/ True RMS, 1 Sec update time; 4 Quadrant Power & Energy
True RMS measurements Measurement:
Simultaneous sampling of Volts & Amps Input Voltage: 4 Voltage inputs (V1 V2 V3 VN) Programmable 110 or
Accuracy class 1.0 as per IEC 62053-21, Class 0.5 as per IEC 62053-22. 415V LL Nominal (Range 80 to 550V LL) Primary
User programmable password protection Programmable up to 999 kV. Burden: 0.2VA Max. per phase.
Energy resetting @ 999999 KVAh × Transformer ratio
Input Frequency: 45 - 65 Hz
Displays more than 25 parameters - Basic [VLL, VLn, A (Average &
Phasewise), F ], Power [W, PF, VA (Total & Phasewise)] and Input Current: Current inputs (A1 A2 A3) - Each channel is
Energy [Wh, LH] independently configurable. Primary Programmable
up to 99 kA.
Note: Customization can be done for other parameters provided volume justify CT output : Can be upto 1000 mV or 100 mA from Split core
CT or Hanging CTs - Manufacturing option.

Aux-Supply 80 - 300V AC / DC, 40-70Hz.


Applications : Burden: 4VA Max.

Display resolution: 1 row 6 Digit for Integrated, 4 Digits for Instantaneous


For remote reading and control, the BM is supported by ELNet
Software, designed for remote setup and data viewing and analysis CT PT Ratio Max: 2000 MVA Programmable.
Building Management System: With the open modbus protocol, the Communication Parity: Odd, Even, None (Prefered Even)
BM can interface any system, such as building management, HMI etc RS485 interface: Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
Compact : Ideal for Data Center
communication and other circuits.
Ideal for apartments / commercial complexes billing and load pattern
Weight: Unpacked: 275 gms Packed: 350 gms (weight of CT excluded)
study on individual phase
Individual phase kWh measurement provides user flexibility of
measuring 3 phase 3 channels or single phase 9 channels
Schematic Diagram
Primary current can be independently configured making it ideal for
any kind of industry or upgradation
A/C Load LMS Data Center
Note: Additional error of 0.1% of full scale, for meter input current below 500mA for 5A setting

MODBUS

Current Transformers :

Hang on CT- 5A or 50A or 100A or 200A Up to 100A, 16mm ID


Motor/ Pumps
Load

Mechanical Specification

Clip on CT-5A | 50A | 100A | 250A Split Core CT-100A | 400A | 1000A
67
72

90

45

49 elmeasure.com

You might also like