SynaptiQ User Manual - Annex A Definition of Indicators
SynaptiQ User Manual - Annex A Definition of Indicators
DOCUMENT CONFIDENTIEL
[email protected]
www.3E.eu
ANNEX A: DEFINITION OF INDICATORS
The following naming conventions (see Table 3) are applied in order to define the naming of the indicators in SynaptiQ.
1. Indicator grouping by order of In order to group indicators in the user interface lists, the indicator name begins with the most
words generic word and specifies in the next words. E.g. Energy Expected and not Expected Energy.
2. Implicit specification Indicator specifications that are considered as the most generic case, are omitted for reasons of
simplification. E.g. The irradiation indicator that uses sensor data (if available) and fills data gaps
with satellite irradiation data, is considered as the standard irradiation indicator and is therefore
named Irradiation. E.g. The energy yield calculated from the inverter data is considered the most
generic energy indicator and therefore named Energy.
3. Different indicator source is If the same indicator (that is calculated in the same way) can have several sources of data, the
specified between brackets non-standard data sources are specific between brackets. E.g. Availaibility (Sensor) is calculated
using only sensor irradiation data while the Availability uses sensor data, but complements it with
satellite irradiation data when sensor data are missing.
4. Different indicator calculation If the same indicator can be calculated in several ways, the non-standard calculation method will
algorithms are specified between be specific between brackets. E.g. Availability (Gross) is a non-standard method of calculation
brackets availability in which missing data are considered as unavailable.
The table below provides a description of all indicators available in SynaptiQ. For each of the indicators, it is indicated at which granularity and for which
SynaptiQ (see Table 2) object the indicator is available.
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Angle axis 1 ° Angle of first axis. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Angle axis 1 - error ° Difference between angle and set-point of first axis. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Angle axis 1 - setpoint ° Setpoint for angle of first axis. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Angle axis 2 ° Angle of second axis. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Angle axis 2 - error ° Difference between angle and set-point of second 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
axis. month; quarter; year
Angle axis 2 - setpoint ° Asetpoint for angle of second axis. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Availability % Availability calculated using Energy and Irradiation. 5'; 10'; 15'; 30'; hour; day; week; X X X X
Time intervals with the status Missing data or month; quarter; year
Exclusion Interval are excluded.
Availability % Availability calculated using Energy Generation and 5'; 10'; 15'; 30'; hour; day; week; X
Irradiation. Time intervals with the status Missing month; quarter; year
data or Exclusion Interval are excluded.
Availability (Gross) % Availability calculated using Energy and Irradiation. 5'; 10'; 15'; 30'; hour; day; week; X X X X
The calculation excludes intervals with the status month; quarter; year
Exclusion Interval and those where Irradiation has
status Missing data. If Energy has status Missing
data, the interval is considered not available.
Availability (Satellite Gross) % Availability calculated using Energy and Irradiation hour; day; week; month; quarter; year X X X X
(Satellite). The calculation excludes intervals with the
status Exclusion Interval and those where Irradiation
(Satellite) has status Missing data. If Energy has
status Missing data, the interval is considered not
available.
Availability (Satellite) % Availability calculated using Energy and Irradiation hour; day; week; month; quarter; year X X X X
(Satellite). Time intervals with the status Missing data
or Exclusion Interval are excluded.
Availability (Sensor Gross) % Availability calculated using Energy and Irradiation hour; day; week; month; quarter; year X X X
(Sensor). The calculation excludes intervals with the
status Exclusion Interval and those where Irradiation
(Sensor) has status Missing data. If Energy has
status Missing data, the interval is considered not
available.
Availability (Sensor) % Availability calculated using Energy and Irradiation hour; day; week; month; quarter; year X X X
(Sensor). Time intervals with the status Missing data
or Exclusion Interval are excluded.
Availability Guaranteed % Guaranteed availability as defined for the period in day; week; month; quarter; year X X X
the SynaptiQ Configurator.
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Balance ¤ The balance of a financial account. day; week; month; quarter; year
Capacity DC kWp Installed generator capacity. For PV: based on the 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
flashtest or rated module STC peak power as defined month; quarter; year
in the SynaptiQ Configurator; for Wind: same as
Capacity AC.
Cash flow ¤ The cash flow of a financial account. day; week; month; quarter; year
Cloud altitude m 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Cloud cover % Cloud cover. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X X
month; quarter; year
Cloud thickness m 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
CO2 Savings tons CO2 savings resulting from the solar energy day; week; month; quarter; year X X
production, expressed in tons CO2. Calculated using
Energy and a defined conversion factor.
Cosinus Phi 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Count Data The number of data samples. 1'; 5'; 10'; 15'; 30'; hour; day X X X
CUF % Capacity Utilization Factor: Energy divided by day; week; month; quarter; year X X X X
Capacity DC times the length of time interval
CUF (Meter) % Capacity Utilization Factor: Energy (Meter) divided by day; week; month; quarter; year X X X
Capacity DC times the length of time interval
Current AC A 1'; 5'; 10'; 15'; 30'; hour; day X X X X
Current AC THD % Total harmonic distortion of AC current 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Current AC Unbalance A 1'; 5'; 10'; 15'; 30'; hour; day X X X
Current DC per String A Current DC divided by the number of connected 1'; 5'; 10'; 15'; 30'; hour; day; week; X
strings. month; quarter; year
Delay Data s The delay for data events, i.e. the time between 1'; 5'; 10'; 15'; 30'; hour; day X X
(internal) recording and (external) occurrence.
Energy kWh AC Energy production calculated based on the data 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
provided by the generation system and the imported month; quarter; year
historical data.
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Energy (Meter) kWh AC energy balance of the generation system. The 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
balance may be negative due to energy consumption month; quarter; year
by the generation system.
Energy (No Historical) kWh AC Energy production calculated based on the data 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
provided by the inverters. month; quarter; year
Energy (With Replacement) kWh AC Energy production calculated based on the data 1'; 5'; 10'; 15'; 30'; hour; day; week; X
provided by the inverters. Replaced inverters are month; quarter; year
taken into account by calculating the energy per
inverter array.
Energy AC Charging kWh 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
month; quarter; year
Energy Business Plan kWh AC Energy production defined for the given period in day; week; month; quarter; year X X X X
the business plan as configured in the SynaptiQ
Configurator.
Energy Consumption kWh Local energy consumption which is not related to the 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
generation system. month; quarter; year
Energy Consumption [Obsolete] kWh Energy consumption measured at meter level. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Energy Counter kWh Energy counter value as reported by the device 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
normalised to kWh. month; quarter; year
Energy Daily kWh Energy daily counter value as reported by the device 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
normalised to kWh. month; quarter; year
Energy DC kWh Energy measured at DC level. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Energy DC Charging kWh 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
month; quarter; year
Energy DC Specific kWh/kWp Energy DC divided by Capacity DC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Energy Export kWh AC energy exported to the grid, always positive. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Energy Generation kWh AC energy generated by the generators without 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
considering AC losses. month; quarter; year
Energy Grid-Consumption kWh The part of Energy Consumption that was imported 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
from the grid. month; quarter; year
Energy Guaranteed kWh Guaranteed Energy production calculated based on day; week; month; quarter; year X X X X
PR Guaranteed, Capacity DC and Irradiation.
Energy Import kWh AC energy imported from the grid, always positive. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Energy Import/Export kWh Energy balance measured at the grid injection point 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
by the meter. The balance is defined as Energy month; quarter; year
Import minus Energy Export, so energy production
counts negative.
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Energy Import/Export [Obsolete] kWh Energy balance measured at the grid injection point 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
by the meter. The balance is defined as Energy month; quarter; year
Import minus Energy Export, so energy production
counts negative.
Energy Performance Index % Ratio of Energy Generation over Energy Simulation 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
(Generation) month; quarter; year
Energy Production kWh AC energy produced by a generator or aggregate as 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
input to a next level of aggregation with AC losses month; quarter; year
considered up to this level.
Energy Self-Consumption kWh The part of Energy Consumption that was produced 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
by the generation system. month; quarter; year
Energy Self-Consumption kWh The part of Energy Consumption that was produced 1'; 5'; 10'; 15'; 30'; hour; day; week; X
[Obsolete] by the generation system month; quarter; year
Energy Simulation kWh Simulated AC energy production for the given PV 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
plant configuration and under the given month; quarter; year
meteorological conditions, calculated by the PV plant
simulation model. Available as of the next day.
Energy Specific kWh/kWp Energy Generation divided by Capacity DC. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Energy Specific (Meter) kWh/kWp Energy (Meter) divided by Capacity DC. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
month; quarter; year
Energy Specific (With Historical) kWh/kWp Energy divided by Capacity DC including Historical day; week; month; quarter; year X X
data.
Energy Specific [Obsolete] kWh/kWp Energy divided by Capacity DC. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Energy Specific Simulation kWh/kWp Energy Simulation (Generation) divided by Capacity 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
DC. month; quarter; year
Energy System kWh AC energy consumed by the generation system. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
month; quarter; year
Energy System-Consumption kWh AC energy consumed by the generation system, 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
which is the negative output component of Energy month; quarter; year
Generation.
Energy System-Import kWh AC energy imported by the generation system, which 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
is the negative input component of Energy month; quarter; year
Generation.
Energy VAh kWh VAh = Volt·Ampere hour, Apparent AC Energy 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Energy varh kWh varh = volt·ampere reactive hour, Reactive AC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Energy month; quarter; year
Energy varh capacitive kWh varh = volt·ampere reactive capacitive hour, Reactive 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Capacitive AC Energy month; quarter; year
Energy varh Daily kWh Daily counter for Energy varh. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Energy varh Import kWh varh = volt·ampere reactive hour, Reactive AC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Energy imported. month; quarter; year
Energy varh inductive kWh varh = volt·ampere reactive inductive hour, Reactive 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Inductive AC Energy month; quarter; year
Energy varh Q1 kWh varh = volt·ampere reactive hour in Quadrant 1 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
(import active/import reactive) month; quarter; year
Energy varh Q2 kWh varh = volt·ampere reactive hour in Quadrant 2 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
(export active/import reactive) month; quarter; year
Energy varh Q3 kWh varh = volt·ampere reactive hour in Quadrant 3 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
(export active/export reactive) month; quarter; year
Energy varh Q4 kWh varh = volt·ampere reactive hour in Quadrant 4 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
(import active/export reactive) month; quarter; year
Flow water m³/s Flow of water as volume per unit of time. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Fraction cleaned % Fraction of cleaned items vs total number. day; week; month; quarter; year X
Fraction Open % Opening of a valve or other device as percentage of 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
completely open. month; quarter; year
Fraction Soling Loss % The fraction of total performance lost due to soiling 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
transmission loss. month; quarter; year
Frequency Grid Hz 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Humidity % Relative humidity 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Impedance Grid Ohm 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Income ¤ Income calculated based on Energy and Tariff. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Income (Meter) ¤ Income calculated based on Energy (Meter) and 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
Tariff. month; quarter; year
Income Business Plan ¤ Budgeted income calculated based on Energy day; week; month; quarter; year X X X
Business Plan and Tariff.
Income Simulation ¤ Simulated income calculated based on Energy hour; day; week; month; quarter; year X X
Simulation and Tariff.
Index Loss Soiling % The ratio of soiled to clean performance (1 - Fraction 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
Soling Loss). month; quarter; year
Index Self-Consumption % Energy Self-Consumption divided by Energy 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
Production month; quarter; year
Index Self-Consumption [Obsolete] % Energy Self-Consumption [Obsolete] divided by 1'; 5'; 10'; 15'; 30'; hour; day; week; X
Energy (Meter) month; quarter; year
Index Self-Sufficiency % Energy Self-Consumption divided by Energy 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
Consumption month; quarter; year
Index Self-Sufficiency [Obsolete] % Energy Self-Consumption [Obsolete] divided by 1'; 5'; 10'; 15'; 30'; hour; day; week; X
Energy Consumption month; quarter; year
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Irradiance W/m² Irradiance in the plane of the array(s) calculated 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X X X X X
using the same configuration and data as Irradiation.
Irradiance (Sensor) W/m² 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X X X X X
Irradiance Diffuse W/m² 1'; 5'; 10'; 15'; 30'; hour; day X
Irradiance Horizontal W/m² 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X X X X
Irradiation Wh/m² Irradiation in the plane of the array(s) calculated 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
based on Irradiation (Sensor), if available, and month; quarter; year
complemented with Irradiation (Satellite) for periods
for which Irradiation (Sensor) is not available.
Irradiation Wh/m² Irradiation in the plane of the array(s). 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Irradiation (Satellite) Wh/m² Irradiation in the plane of the modules (per module 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
group), as provided by 3E's satellite irradiation month; quarter; year
service. Available as of the next day.
Irradiation (Sensor) Wh/m² 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X X X X
month; quarter; year
Irradiation Business Plan Wh/m² Irradiation as set in the business plan defined in the day; week; month; quarter; year X X X X
SynaptiQ Configurator.
Irradiation Diffuse (Satellite) Wh/m² Diffuse irradiation, as provided by 3E's satellite 1'; 5'; 10'; 15'; 30'; hour; day; week; X
irradiation service. Available as of the next day. month; quarter; year
Irradiation Horizontal Wh/m² Irradiation in the horizontal plane. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Irradiation Horizontal (Satellite) Wh/m² Irradiation in the horizontal plane, as provided by 3E's 1'; 5'; 10'; 15'; 30'; hour; day; week; X
satellite irradiation service. Available as of the next month; quarter; year
day.
Level Gate cm Opening of a gate as distance. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Level Oil cm Level of oil. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Level Water cm Level of water. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
Loss Export kWh The product of Loss Generation and Loss Factor AC. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Loss Generation kWh An estimate of energy loss due to reduced availability 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
or performance. month; quarter; year
Loss Transmission kWh The difference of Energy Generation and Energy 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Export. month; quarter; year
Luminous Flux lm 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Power AC W Active AC Power. 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Power AC - setpoint W 1'; 5'; 10'; 15'; 30'; hour; day X X X X X
Power AC Efficiency % Power AC divided by Power DC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Power AC Import W Active AC Power import. 1'; 5'; 10'; 15'; 30'; hour; day X X X X
Power AC Limit W The maximum value for Power AC as imposed by 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
external constraints. When no constraints apply, the month; quarter; year
value is the same as Capacity AC (Rated).
Power AC Simulation W Active AC Power Simulation. 1'; 5'; 10'; 15'; 30'; hour; day X
Power AC Specific kW/kWp Power AC divided by Capacity DC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Power AC Specific Simulation kW/kWp Power AC Simulation divided by Capacity DC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Power DC W DC Power. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X X X
month; quarter; year
Power DC Specific kW/kWp Power DC divided by Capacity DC 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Power Factor 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Power Factor - setpoint 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Power Limitation Normalized % Normalized active power limitation setpoint, same as 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
Power AC Limit / Capacity AC (Rated). month; quarter; year
Power VA kVA VA = volt·ampere, Apparent AC Power 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Power var kVAr var = volt·ampere reactive, Reactive AC Power 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
month; quarter; year
Power var - setpoint kVAr 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Power var capacitive kVAr var = volt·ampere reactive capacitive, Reactive 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Capacitive AC Power month; quarter; year
Power var inductive kVAr var = volt·ampere reactive inductive, Reactive 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X
Inductive AC Power month; quarter; year
PR % Performance ratio calculated using Irradiation and hour; day; week; month; quarter; year X X X X
Energy. Time intervals with the status Missing data or
Exclusion Interval are excluded.
PR % Performance ratio calculated using Irradiation and hour; day; week; month; quarter; year X
Energy Generation. Time intervals with the status
Missing data or Exclusion Interval are excluded.
PR (Gross) % Performance ratio calculated using the sum of hour; day; week; month; quarter; year X X X X
Irradiation and the sum of Energy over the reported
period. The sums exclude intervals with the status
Exclusion Interval.
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
PR (Meter Gross) % Performance ratio calculated using the sum of hour; day; week; month; quarter; year X X X
Irradiation and the sum of Energy (Meter) over the
reported period. The sums exclude intervals with the
status Exclusion Interval.
PR (Meter Satellite Gross) % Performance ratio calculated using the sum of hour; day; week; month; quarter; year X X
Irradiation (Satellite) and the sum of Energy (Meter)
over the reported period. The sums exclude intervals
with the status Exclusion Interval.
PR (Meter Satellite) % Performance ratio calculated using Irradiation hour; day; week; month; quarter; year X X X
(Satellite) and Energy (Meter). Time intervals with the
status Missing data or Exclusion Interval are
excluded.
PR (Meter) % Performance ratio calculated using Irradiation and hour; day; week; month; quarter; year X X X
Energy (Meter). Time intervals with the status
Missing data or Exclusion Interval are excluded.
PR (Satellite Gross) % Performance ratio calculated using the sum of hour; day; week; month; quarter; year X X X
Irradiation (Satellite) and the sum of Energy over the
reported period. The sums exclude intervals with the
status Exclusion Interval.
PR (Satellite) % Performance ratio calculated using Irradiation hour; day; week; month; quarter; year X X X X
(Satellite) and Energy. Time intervals with the status
Missing data or Exclusion Interval are excluded.
PR (Sensor Gross) % Performance ratio calculated using the sum of hour; day; week; month; quarter; year X X
Irradiation (Sensor) and the sum of Energy over the
reported period. The sums exclude intervals with the
status Exclusion Interval.
PR (Sensor) % Performance ratio calculated using Irradiation hour; day; week; month; quarter; year X X
(Sensor) and Energy. Time intervals with the status
Missing data or Exclusion Interval are excluded.
PR (With Historical) % Performance ratio calculated using Irradiation and hour; day; week; month; quarter; year X X
Energy. Time intervals with the status Missing data or
Exclusion Interval are excluded. Time intervals with
the status Historical data are included.
PR Available % Performance ratio calculated using Irradiation and hour; day; week; month; quarter; year X X X X
Energy, considering only time intervals with the
status Available. Time intervals with the status
Missing data or Exclusion Interval are excluded.
PR Available (Satellite) % Performance ratio calculated using Irradiation hour; day; week; month; quarter; year X X X X
(Satellite) and Energy, considering only time intervals
with the status Available. Time intervals with the
status Missing data or Exclusion Interval are
excluded.
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
PR Available (Sensor) % Performance ratio calculated using Irradiation hour; day; week; month; quarter; year X X
(Sensor) and Energy, considering only time intervals
with the status Available. Time intervals with the
status Missing data or Exclusion Interval are
excluded.
PR Business Plan % Performance ratio as configured in the business plan day; week; month; quarter; year X X
in the SynaptiQ Configurator.
PR Guaranteed % Guaranteed performance ratio as defined in the day; week; month; quarter; year X X X
SynaptiQ Configurator.
PR Simulation % Performance ratio calculated using Irradiation and hour; day; week; month; quarter; year X X X X
Energy Simulation. Time intervals with the status
Missing data or Exclusion Interval are excluded.
PR Simulation (Gross) % Performance ratio calculated using the sum of hour; day; week; month; quarter; year X X X X
Irradiation and the sum of Energy Simulation over the
reported period. The sums exclude intervals with the
status Exclusion Interval.
Precipitation mm Amount of rainfall during the interval. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Precipitation (Meteo) mm Amount of rainfall during the time interval as provided 15'; 30'; hour; day; week; month; X
by the SynaptiQ meteo service. quarter; year
Precipitation Probability % Probability of snow or rainfall. 15'; 30'; hour; day; week; month; X X
quarter; year
Pressure Air hPa Air pressure 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Resistance Isolation Ohm 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Revenue ¤ Revenue calculated based on Energy Export and 1'; 5'; 10'; 15'; 30'; hour; day; week; X
Tariff. month; quarter; year
Snowfall cm Accumulated snowfall. 15'; 30'; hour; day; week; month; X X X X X X
quarter; year
Snowload kg/m² Snow mass per unit of surface 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X
month; quarter; year
State of Charge % 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
State of Charge Error % 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
State of Health % 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
Tariff ¤ Conversion factor that is used to calculate an income 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
from an energy. Tariff is defined in the SynaptiQ month; quarter; year
Configurator.
Tariff fraction % General percentage used in income computations. 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Temperature Ambient °C 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Temperature Ambient (Meteo) °C Ambient temperature on-site given by the SynaptiQ 1'; 5'; 10'; 15'; 30'; hour; day; week; X
meteo service. month; quarter; year
Temperature Battery °C Temperature of a battery. 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
Temperature Enclosure °C Air temperature inside a device enclosure, e.g., a 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X X
cabinet.
Temperature IGBT °C Temperature of the IGBT component. 1'; 5'; 10'; 15'; 30'; hour; day X X X X
Temperature MOSFET °C Temperature of the MOSFET component. 1'; 5'; 10'; 15'; 30'; hour; day X X X X
Temperature Oil °C Transformer oil temperature 1'; 5'; 10'; 15'; 30'; hour; day X X X X X
Temperature PV Module °C Temperature of PV cells. 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X X X
Temperature Solid °C Temperature of an electrical component. 1'; 5'; 10'; 15'; 30'; hour; day X X X X
Temperature Winding °C Transformer winding temperature 1'; 5'; 10'; 15'; 30'; hour; day X X X X X
Vertical visibility m 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Voltage AC V Voltage between a single phase and neutral or the 1'; 5'; 10'; 15'; 30'; hour; day X X X X
average phase to neutral over all phases.
Voltage AC 1-2 V Line voltage between phases L1 and L2 1'; 5'; 10'; 15'; 30'; hour; day X X X
Voltage AC 2-3 V Line voltage between phases L2 and L3 1'; 5'; 10'; 15'; 30'; hour; day X X X
Voltage AC 3-1 V Line voltage between phases L3 and L1 1'; 5'; 10'; 15'; 30'; hour; day X X X
Voltage AC Average LL V Average line voltage 1'; 5'; 10'; 15'; 30'; hour; day X X
Voltage AC Ground V Voltage AC relative to ground. 1'; 5'; 10'; 15'; 30'; hour; day X X X
Voltage AC THD % Total harmonic distortion of AC voltage. 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X
month; quarter; year
Voltage Battery V Voltage of a battery. 1'; 5'; 10'; 15'; 30'; hour; day X X X X X X X
Meteo Station
Inverter Input
Sensor Box
Site Group
Reference
Sub-Plant
AC Phase
DC Node
DC Input
Modules
Inverter
Sensor
Site
Indicator Name Unit Description Available Granularities
Voltage DC V 1'; 5'; 10'; 15'; 30'; hour; day X X X X X
Voltage DC Charging V 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
Voltage tap ¤ Tap position in transformer. 1'; 5'; 10'; 15'; 30'; hour; day X X X
Wind Bearing ° 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Wind Speed m/s 1'; 5'; 10'; 15'; 30'; hour; day; week; X X X X X X
month; quarter; year
Wind Speed (Meteo) m/s 1'; 5'; 10'; 15'; 30'; hour; day; week; X
month; quarter; year
Working Hours h Working hours during the device lifetime 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
month; quarter; year
Working Time h The number of hours a device has been on during an 1'; 5'; 10'; 15'; 30'; hour; day; week; X X
interval. month; quarter; year
[email protected] D o c u me n t v e r s i o n d a t e
www.3E.eu 01/07/2021
Doc u me n t Co nf i d en t ia l ity
Cl as s if ic at i o n:
Client organisation only
This document is intended solely for clients who have entered into a SynaptiQ
agreement with 3E.
Clients receive the non-exclusive, non-transferable right to use this document for
internal use only, and subject to the confidentiality classification indica ted on this
document. Client agrees not to communicate or copy the document, in whole in
part, to third parties without the prior written consent of 3E. Even if such consent
has been given, 3E will not be liable to any third parties for the consequences of
the use by a third party of this document.