SC12CLX.
2
LBP Compressor
R404A/R507
208-230V 60Hz
General
Code number 104L2699
Approvals UL984, KC
Compressors on pallet 80
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C – -45 to -10
Voltage range V – 187 - 254
Max. condensing temperature continuous (short) °C – 55 (60)
Max. winding temperature continuous (short) °C – 125 (135)
Cooling requirements
Frequency Hz 50 60 S = Static cooling normally sufficient
O = Oil cooling
Application LBP MBP HBP LBP MBP HBP
F1 = Fan cooling 1.5 m/s
32°C – – – F2 – – (compressor compartment temperature
38°C – – – F2 – – equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
43°C – – – F2 – –
SG = Suction gas cooling normally sufficent
Remarks on application: – = not applicable in this area
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 19.6 –
Cut in Current, HST | LST A 19.6 –
Resistance, main | start winding (25°C) Ω 3.8 13.7
Design
Displacement cm3 12.87
Oil quantity (type) cm3 500 (polyolester)
Maximum refrigerant charge g 1300
Free gas volume in compressor cm 3
1510
Weight without electrical equipment kg 13.7
Dimensions
Height mm A 219
B 213
B1 193
B2 110
Suction connector location/I.D. mm | angle C 9.7 | 37°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.5 | 37°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.5 | 37°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
January 2020 DES.D.461.Z2.02 1/2
EN 12900 Household (CECOMAF)* 230V, 60Hz, fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 141 233 343 473 626 683 804 1011 1248
Power cons. in W 286 344 401 457 515 535 575 638 705
Current cons. in A 1.70 1.81 1.93 2.07 2.24 2.30 2.42 2.62 2.83
COP in W/W 0.49 0.68 0.86 1.03 1.21 1.28 1.40 1.58 1.77
ASHRAE LBP 230V, 60Hz, fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 82 190 317 465 640 706 845 1084 1361
Power cons. in W 264 334 401 468 534 557 602 671 744
Current cons. in A 1.57 1.71 1.86 2.04 2.23 2.30 2.44 2.67 2.91
COP in W/W 0.31 0.57 0.79 1.00 1.20 1.27 1.41 1.62 1.83
ASHRAE LBP* 230V, 60Hz, fan cooling F2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 176 283 426 598 739 805 1051 1339 1467
Power cons. in W 289 345 406 468 512 531 598 669 699
Current cons. in A 1.72 1.82 1.95 2.11 2.23 2.29 2.49 2.72 2.81
COP in W/W 0.61 0.82 1.05 1.28 1.44 1.52 1.76 2.00 2.10
Accessories for SC12CLX.2 (60 Hz) Figure Code Test conditions EN 12900/ ASHRAE ASHRAE
number CECOMAF* LBP LBP*
Sarting device 550 mm cable length 117-7027 Condensing temperature 45°C 54.4°C 43.3°C
650 mm cable length a3 117-7046 Ambient temperature 32°C 32°C 32°C
1000 mm cable length 117-7040 Suction gas temperature 32°C 32°C 32°C
Cover b 103N2008 Liquid temperature no subcooling 32°C 32°C
Starting relay 6.3 mm spade connectors a2 Components
Start. capacitor 80 µF 6.3 mm spade connectors c of starting Mounting accessories Code number
Run capacitor 10 µF 6.3 mm spade connectors e device Bolt joint for one comp. Ø: 16 mm 118-1917
Cord relief d 103N1004 Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the
respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. www.secop.com
2/2 DES.D.461.Z2.02 January 2020
SC12CLX.2
LBP Compressor
R404A/R507
208-230V 60Hz
General
Code number 104L2699
Approvals UL984, KC
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -49 to 41
Voltage range V – 187 - 254
Max. condensing temperature continuous (short) °F – 131 (140)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements S = Static cooling normally sufficient
Frequency Hz 50 60 O = Oil cooling
Application LBP MBP HBP LBP MBP HBP F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
90°F – – – F2 – –
equal to ambient temperature)
100°F – – – F2 – – F2 = Fan cooling 3.0 m/s necessary
110°F – – – F2 – – SG = Suction gas cooling normally sufficent
Remarks on application: – = not applicable in this area
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 19.6 –
Cut in Current, HST | LST A 19.6 –
Resistance, main | start winding (77°F) Ω 3.8 13.7
Design
Displacement cu.in 0.78
Oil quantity (type) fl.oz. 16.9 (polyolester)
Maximum refrigerant charge oz. 45.8
Free gas volume in compressor fl.oz. 51.1
Weight without electrical equipment lbs. 27.7
Dimensions
Height inch A 8.62
B 8.39
B1 7.60
B2 4.33
Suction connector location, I.D. in. | angle C 0.378-0.385 | 37°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
January 2020 DES.D.461.Z2.22 1/2
ASHRAE LBP 230V, 60Hz, fan cooling F2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 281 649 1133 1712 2183 2404 3229 4205 4642
Power cons. in W 264 334 409 482 534 556 632 711 744
Current cons. in A 1.57 1.71 1.88 2.08 2.23 2.30 2.54 2.80 2.91
EER in BTU/Wh 1.06 1.94 2.77 3.55 4.09 4.32 5.11 5.91 6.24
ASHRAE LBP* 230V, 60Hz, fan cooling F2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 598 962 1449 2036 2516 2740 3575 4556 4994
Power cons. in W 289 345 406 468 512 531 598 669 699
Current cons. in A 1.72 1.82 1.95 2.11 2.23 2.29 2.49 2.72 2.81
EER in BTU/Wh 2.07 2.79 3.57 4.35 4.91 5.16 5.98 6.81 7.15
EN 12900 Household (CECOMAF) 230V, 60Hz, fan cooling F2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 481 796 1216 1721 2133 2326 3042 3883 4257
Power cons. in W 286 344 407 470 515 535 602 674 705
Current cons. in A 1.70 1.81 1.95 2.11 2.24 2.29 2.50 2.73 2.83
EER in BTU/Wh 1.68 2.31 2.99 3.66 4.14 4.35 5.05 5.76 6.04
Accessories for SC12CLX.2 (60Hz) Figure Code Test conditions ASHRAE ASHRAE EN 12900/
number LBP LBP* CECOMAF*
Starting device Condensing temperature 130°F 110°F 113°F
21.7 in. cable length 117-7027 Ambient temperature 90°F 90°F 90°F
a3
26.6 in. cable length 117-7046 Suction gas temperature 90°F 90°F 90°F
39.4 in. cable length 117-7040 Liquid temperature 90°F 90°F no subcooling
Cover b 103N2008
Starting relay a2 Components
Start. capacitor 80 µF c of starting Mounting accessories Code number
Run capacitor 10 µF e device Bolt joint for one comp. Ø: 5/8 in. 118-1917
Cord relief d 103N1004 Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective
companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. www.secop.com
2/2 DES.D.461.Z2.22 January 2020