LOTO Template Program
LOTO Template Program
Central School
LOCKOUT TAGOUT
PROGRAM
OSHA 29 CFR 1910.147
Revised: 10/16/2018
??? Central School District
Lockout - Tagout Program
1. Purpose:
This program establishes the minimum requirements for the lockout or tagout of energy isolating
devices. It shall be used to ensure that the machine or equipment are isolated from all
potentially hazardous energy, and locked out or tagged out before employees perform any
servicing or maintenance activities where the unexpected energization, startup or release of
stored energy could cause injury.
2. Definitions:
Affected Employee - An employee whose job requires them to operate or use a machine or
equipment on which servicing or maintenance is being performed under lockout or tagout, or
whose job requires them to work in an area in which such servicing or maintenance is being
performed.
3. Responsibility:
All employees shall be instructed in the safety significance of the lockout/tagout program. Only
those employees listed in Appendix B are authorized to perform lockout or tagout. Each new or
transferred affected employee and other employees whose work operations are or may be in the
area shall be instructed in the purpose and use of lockout/tagout procedures.
Cord and plug connected equipment and machinery do not require lockout/tagout procedures as
long as the attachment cord and plug has been disconnected and is under the sole control of the
individual performing maintenance/repairs.
When all of the following exceptions are met, specific equipment and machinery is not required
to have detailed lockout/tagout procedures:
1. The machine or equipment has no potential for stored or residual energy or
reaccumulation of energy after equipment is shut down.
1
2018-19 School Year
??? Central School District
Lockout - Tagout Program
2. Machine or equipment has a single energy source which can be readily identified and
isolated.
3. Isolation and locking out of the energy source shall completely de-energize and
deactivate the machine or equipment.
4. The machine or equipment is isolated from that energy source and locked out during
servicing and maintenance.
6. The lockout device is under the exclusive control of the authorized employee performing
the servicing.
7. The servicing or maintenance does not create hazards for other employees.
8. The Employer in using this exception to the standard has no accidents involving the
unexpected activation or re-energization of the equipment during servicing.
9. Machinery and equipment requiring detailed procedures, and those procedures, can be
found in Appendix A of this Program.
Notify all affected employees that a lockout or tagout system is going to be utilized and the
reason therefore. The authorized employee shall know the type and magnitude of energy that the
machine or equipment utilizes and shall understand the hazards thereof.
If the machine or equipment is operating, shut it down by the normal stopping procedure
(depress stop button, open toggle switch, etc.)
Operate the switch, valve or other energy isolating device(s). Stored energy (such as that in
springs, elevated machine members, rotating flywheels, hydraulic systems, and air, gas,
steam, or water pressure, etc.) must be dissipated or restrained by methods such as
repositioning, blocking, bleeding down, etc..
Lockout and or tagout the energy isolating device(s) with assigned individual lock(s) or tag(s).
After ensuring that no personnel are exposed, and as a check on having disconnected all energy
sources, operate the push button or other normal operating controls to make certain the
equipment will not operate.
2
2018-19 School Year
??? Central School District
Lockout - Tagout Program
CAUTION
If the service or repair requires exposing live parts of electric equipment, a tag used without a
lock shall be supplemented by at least one additional safety measure that provides a level of
safety equivalent to that obtained by the use of a lock. (e.g. Removal of an isolating circuit
element, blocking of a controlling switch, or opening of an extra disconnecting device.)
Additionally electrical lockout tagout must comply with 29 CFR 1910.333(b), attached as
Appendix D to this program.
After the servicing and or maintenance is complete and equipment is ready for normal
production operations, check the area around the machine(s) or equipment to ensure that no one
is exposed.
After all tools have been removed from the machine or equipment, guards have been reinstalled
and employees are in the clear, remove lockout and or tagout devices. Operate the energy
isolating device(s) to restore energy to the machine or equipment.
Notify affected employees that the servicing or maintenance is complete and the machine or
equipment is ready for use.
When the authorized employee who applied the lockout device is not available to remove it, that
device may be removed under the direction of the Authorized Persons as listed in Appendix B .
Verification by the supervisor that the authorized employee who applied the device is not at the
facility.
Making all reasonable efforts to contact the authorized employee to inform them that their
lockout/tagout will be removed.
Have an authorized employee inspect the equipment to assure the re-energization of the
3
2018-19 School Year
??? Central School District
Lockout - Tagout Program
Insure that the authorized employee is informed that their lock has been removed before they
resume work at the facility.
In the preceding steps, if more than one individual is required to lockout and or tagout
equipment, each shall place their personal lockout and or tagout device on the energy isolating
device(s). When an energy isolating device cannot accept multiple locks or tags, a multiple
lockout or tagout device (hasp) shall be used. If lockout is used, a single lock may be used to
lockout the machine or equipment with the key being placed in a lockout box or cabinet which
allows the use of multiple locks to secure it. Each employee will then use their own lock to
secure the box or cabinet. As each person no longer needs to maintain their lockout protection,
that person will remove their lock from the box or cabinet.
All equipment shall be locked out or tagged out to protect against accidental or inadvertent
operation when such operation could cause injury to personnel. Do not attempt to operate any
switch, valve, or other energy isolating device where it is locked or tagged out.
4
2018-19 School Year
??? Central School District
Lockout - Tagout Program
General awareness training will be provided by Otsego Northern Catskills BOCES Safety/Risk
Officer when scheduled by the District.
Equipment specific training and/or re-training shall be provided for all authorized and affected
employees whenever there is a change in their job assignments, a change in machines, equipment
or processes that present a new hazard, or when there is a change in the energy control
procedures. This training will be provided by the authorized employee responsible for the lock
out tag out program procedures for each affected employee who operates or maintains said
equipment.
The retraining shall establish employee proficiency and introduce new or revised control
methods and procedures, as necessary.
I have received training in my Employer’s Lockout/Tagout Program, and this Employer’s program has
been explained to me, that I have had a opportunity to ask questions, that I thoroughly understand these
guides and the use of materials and have been given a copy of this form.
Date:__________________
Name:__________________________________________________________
(print)
Signature:_______________________________________________________
5
2018-19 School Year
??? Central School District
Lockout - Tagout Program
The District shall conduct a periodic inspection of the energy control program at least annually
to ensure that the program and the requirements of the standard are being followed.
The periodic inspection shall be performed by an authorized employee other than the
one(s) utilizing the energy control program being inspected.
The periodic inspection shall be designed to correct any deviations or inadequacies observed.
Where lockout is used for energy control, the periodic inspection shall include a review, between
the inspector and each authorized employee, of that employee’s responsibilities under the energy
control program being inspected.
Equipment/machine: ____________________________________________________________
Notes/recommendations:__________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
6
2018-19 School Year
??? Central School District
Lockout - Tagout Program
APPENDIX A
EQUIPMENT TYPE:____________________________________________________________
LOCATION:___________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
DATE:_____________________________
7
2018-19 School Year
??? Central School District
Lockout - Tagout Program
APPENDIX B
AFFECTED EMPLOYEES:
8
2018-19 School Year
??? Central School District
Lockout - Tagout Program
APPENDIX C
Primary key is removed from bus/other school vehicle. Primary and spare keys are tagged with
standard tags.
Tagged keys are placed on assigned board in transportation supervisor’s office or kept with
mechanic performing the maintenance.
If work is being performed on school bus, tagged keys will be placed in conspicuous location
near location of work being performed and/or cover and lock will be placed over steering wheel.
9
2018-19 School Year
??? Central School District
Lockout - Tagout Program
APPENDIX D
===============================================================
1910.333 Selection and use of work practices.
======================================================
(a) General. Safety-related work practices shall be employed to prevent electric shock or other injuries resulting
from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are
or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the
associated electrical hazards.
(1) De-energized parts. Live parts to which an employee may be exposed shall be De-energized before the
employee works on or near them, unless the employer can demonstrate that de-energizing introduces additional
or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at
less than 50 volts to ground need not be De-energized if there will be no increased exposure to electrical burns or
to explosion due to electric arcs.
NOTE 1: Examples of increased or additional hazards include interruption of life support equipment, deactivation
of emergency alarm systems, shutdown of hazardous location ventilation equipment, or removal of illumination for
an area.
NOTE 2: Examples of work that may be performed on or near energized circuit parts because of infeasibility due to
equipment design or operational limitations include testing of electric circuits that can only be performed with the
circuit energized and work on circuits that form an integral part of a continuous industrial process in a chemical
plant that would otherwise need to be completely shut down in order to permit work on one circuit or piece of
equipment.
NOTE 3: Work on or near De-energized parts is covered by paragraph (b) of this section.
(2) Energized parts. If the exposed live parts are not De-energized (i.e., for reasons of increased or additional
hazards or infeasibility), other safety related work practices shall be used to protect employees who may be
exposed to the electrical hazards involved. Such work practices shall protect employees against contact with
energized circuit parts directly with any part of their body or indirectly through some other conductive object.
The work practices that are used shall be suitable for the conditions under which the work is to be performed and
for the voltage level of the exposed electrical conductors or circuit parts. Specific work practice requirements are
derailed in paragraph (c) of this section.
(1) Application. This paragraph applies to work on exposed De-energized parts or near enough to them to
expose the employee to any electrical hazard they present. Conductors and parts of electric equipment that have
been De-energized but have not been locked out or tagged in accordance with paragraph (b) of this section shall
be treated as energized parts. and paragraph (c) of this section applies to work on or near them.
(2) Lockout and tagging. While any employee is exposed to contact with parts of fixed electric equipment or
circuits which have been De-energized, the circuits energizing the parts shall be locked out or tagged or both in
accordance with the requirements of this paragraph. The requirements shall be followed in the order in which
they are presented (i.e., paragraph (b)(2)(i) first, then paragraph (b)(2)(il), etc.).
NOTE 1: As used in this section, fixed equipment refers to equipment fastened in place or connected by permanent
wiring methods.
NOTE 2: Lockout and tagging procedures that comply with paragraphs (c) through (f) of ' 1910.147 will also be
deemed to comply with paragraph (b)(2) of this section provided that:
(1) The procedures address the electrical safety hazards covered by this Subpart; and
10
2018-19 School Year
??? Central School District
Lockout - Tagout Program
(2) The procedures also incorporate the requirements of paragraphs (b)(2)(iii?(D) and (b)(2) (iv)(B) of this
section.
(i) Procedures. The employer shall maintain a copy of the procedures outlined in paragraph (b)(2) and shall
make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized
representatives.
NOTE: The written procedures may be in the form of a copy of paragraph (b) of this section.
(a) Safe procedures for de-energizing circuits and equipment shall he determined before circuits or equipment
are De-energized.
(b) The circuits and equipment to be worked on shall be disconnected from all electric energy sources. Control
circuit devices, such as push buttons, selector switches, and interlocks, may not be used as the sole means for
de-energizing circuits or equipment. Interlocks for electric equipment may not be used as a substitute for
lockout and tagging procedures.
(c) Stored electric energy which might endanger personnel shall be released. Capacitors shall be discharged
and high capacitance elements shall be short circuited and grounded, if the stored electric energy might
endanger personnel.
NOTE: If the capacitors or associated equipment are handled in meeting this requirement, they shall be treated
as energized.
(d) Stored non-electrical energy in devices that could re-energize electric circuit parts shall be blocked or
relieved to the extent that the circuit parts could not be accidentally energized by the device.
(a) A lock and a tag shall be placed on each disconnecting means used to de-energize circuits and equipment on
which work is to be performed, except as provided-in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section.
The lock shall be attached so as to prevent persons from operating the disconnecting means unless they resort to
undue force or the use of tools.
(b) Each tag shall contain a statement prohibiting unauthorized operation of the disconnecting means and
removal of the tag.
(c) If a lock cannot be applied, or if the employer can demonstrate that tagging procedures will provide a level
of safety equivalent to that obtained by the use of a lock, a tag may he used without a lock.
(d) A tag used without a lo&, as permitted by paragraph (b)(2)(Hi)(C) of this section, shall be supplemented by
at least one additional safety measure that provides a level of safety equivalent to that obtained by the use of a
lock. Examples of additional safety measures include the removal of an isolating circuit element, blocking of a
controlling switch, or opening of an extra disconnecting device.
(e) A lock may be placed without a tag only under the following conditions:
(2) The lockout period does not extend beyond the work shift.
(3) Employees exposed to the hazards associated with re-energizing the circuit or equipment are
familiar with this procedure.
11
2018-19 School Year
??? Central School District
Lockout - Tagout Program
(iv) Verification of De-energized condition. The requirements of this paragraph shall be met before any
circuits or equipment can be considered and worked as De-energized.
(a) A qualified person shall operate the equipment operating controls or otherwise verify that the equipment
cannot be restarted.
(b) A qualified person shall use test equipment to test the circuit elements and electrical parts of equipment to
which employees will be exposed and shall verify that the circuit elements and equipment parts are
De-energized. The test shall also determine if any energized condition exists as a result of inadvertently
induced voltage or unrelated voltage induced even though specific parts of the circuit have been De-energized
and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be
checked for proper operation immediately before and immediately after this test.
(v) Re-energizing equipment. These requirements shall be met, in the order given, before circuits or
equipment are re-energized, even temporarily
(a) A qualified person shall conduct tests and visual inspections, as necessary, to very that all tools. Electrical
jumpers, shorts, grounds, and other such devices have been removed, so that the circuits and equipment can be
safely energized.
(b) Employees exposed to the hazards associated with re-energizing the circuit or equipment shall be warned to
stay clear of circuits and equipment.
(c) Each lock and tag shall be removed by the employee who applied it or under his or her direct supervision.
However, if this employee is absent from the workplace, then the lock or tag may be removed by a qualified
person designated to perform this task provided that:
(1) The employer ensures that the employee who applied the lock or tag is not available at the
workplace, and
(2) The employer ensures that the employee is aware that the lock or tag has been removed before he
or she resumes work at that workplace.
(d) There shall be a visual determination that employees are clear of the circuits and equipment.
12
2018-19 School Year