This document provides a revision to a standard drawing for sample coolers. It specifies dimensions and materials for mounting lugs, process inlets, and other components of the cooler design. The revision updates the status of the drawing to "revised" and provides the date and initials of the approver.

Uploaded by

Mohcen ZRIRAK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views

Sample Coolers

This document provides a revision to a standard drawing for sample coolers. It specifies dimensions and materials for mounting lugs, process inlets, and other components of the cooler design. The revision updates the status of the drawing to "revised" and provides the date and initials of the approver.

Uploaded by

Mohcen ZRIRAK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Revision

UOP LLC
Indication
25 East Algonquin Road STANDARD DRAWING
R
Des Plaines, Illinois 60017-5017, USA
8-102-6
mi on.
ssi

DATE STATUS APVD AUTHD


SAMPLE COOLERS
en per
t

24MAR12 REVISED DNM RGP


t
houti i
s wrt

MOUNTING LUG MOUNTING LUG


t
soeverwi

R
pose what

R
1 ’’ (45) X ’’ (6)

TOP PLATE
orany pur

PLAN
’’ PROCESS INLET
2’’ (50) RADIUS 4’’
(SEE NOTE 3)
n any mannerorused f

(1 15)
’’ CLASS 3000

HALF COUPLING 25)


1

(OVERFLOW)
’(

50)

5’
2’

PLAN
(
300)

25)
9 SPACES
225)
oduced i

’(

’(

6’’ STANDARD
-0’


’(

AT 1

WALL PIPE

9’
1
epr

9’’ (230) ’’ PROCESS INLET


s orr

12’’ STANDARD
PROCESS (SEE NOTE 3)
WALL PIPE
her

INLET
’’ CLASS 3000
o ot

’’ PROCESS
SEAL 5’’ (125)
OUTLET HALF COUPLING
osed t

250)
7’’ (180) DIAMETER X ’’ (6) (SEE NOTE 3) (OVERFLOW)
BOTTOM PLATE
’’ CLASS 3000 HALF

’(
scl


3’’ (75)

0’
90)

COUPLING (DRAIN)
R
y of UOP LLC and mustnotbe di

1
RADIUS
3

ELEVATION
" 1
COOLER WITH/
4 COIL

3’’
C ’’ (17) DIAMETER HOLE

50)
(75)
FOR ’’ (16) DIAMETER BOLT

’(
0)

8-SPACES AT 2’
400)
61

1 ’’ (30)
’(
-0’

’(
’’ (6) PLATE

-4’
2’


1
t
oper

65)

30)
90)
30)
he pr

’(
’(
’(

’(


SEAL


aland t

1
1

’’ PROCESS
i
dent

OUTLET
8’’ (200)
(SEE NOTE 3)
i

1’-1 ’’ (340) DIAMETER X


s conf

200)

75)
3’


8’

(3) ’’ (10) BOTTOM PLATE ’’ CLASS 3000 HALF


(

(3)
s documenti

COUPLING (DRAIN)

COOLER WITH ’’ COIL ELEVATION


COOLER WITH ’’ COIL 3/"
COOLER WITH 4 COIL
hi
n t

MOUNTING LUG DETAIL


i
maton i

NOTES:
or

1. COILS TO BE INSERTED IN PIPE BEFORE WELDING BOTTOM PLATE.


nf
e:The i

2. DIMENSIONS SHOWN IN PARENTHESES ARE IN MILLIMETERS.

3. EXTRA HEAVY PIPE COIL WITH FLANGED OR THREADED ENDS. IF THREADED ENDS ARE USED, SEAL WELD
Not

TO CONNECTED PROCESS INLET AND OUTLET. COIL METALLURGY SAME AS CONNECTING PROCESS LINE.