0% found this document useful (0 votes)
49 views4 pages

Brochure Devtech Group CMS CCMS

The Devtech Group Control Monitoring System (GCMS) allows for remote monitoring and control of street lights from a central control station. The GCMS unit can control lights individually or in groups, and features automatic scheduling based on sunrise/sunset as well as energy monitoring and fault detection. Communication to the central station is via various WAN methods including 3G/4G, GSM, Ethernet, and WiFi.

Uploaded by

Chintu Keshav
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views4 pages

Brochure Devtech Group CMS CCMS

The Devtech Group Control Monitoring System (GCMS) allows for remote monitoring and control of street lights from a central control station. The GCMS unit can control lights individually or in groups, and features automatic scheduling based on sunrise/sunset as well as energy monitoring and fault detection. Communication to the central station is via various WAN methods including 3G/4G, GSM, Ethernet, and WiFi.

Uploaded by

Chintu Keshav
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

www.DevtechM2M.

com
2

D VT CH Enabling Smart Cities

DEVTECH GCMS
DEVTECH Group Control Monitoring System is a GSM / GPRS / 3G / 4G /
Equivalent proven technology installed in a feeder or switching point for
remote monitoring and controlling group of street lights.
Applications
Ÿ Street Lighting Ÿ Lighting Ÿ Path way/Road way
Ÿ Parks & Townships Ÿ Municipal Corporations Ÿ Hazardous locations
Ÿ Bridges & Tunnels Ÿ Warehouse/Parking Lot Ÿ Commercial Lighting
Ÿ High Mast/High Bay Ÿ Industrial Lighting Ÿ IT CampusMines
All specification are subject to change without prior notice, visit website for updated documents. | Website : www.DevtechM2M.com
www.DevtechM2M.com
GROUP CONTROL MONITORING SYSTEM

Key Features

Ÿ Centralized control and monitoring group of street lights at feeder level Ÿ Built in Group CMS Applications:
or switching point. - Astronomical clock with high precision RTC
Ÿ Switching ON and OFF the lights of particular feeder switching point with - Scheduling of time of day, day of week/month, date
group or phase wise control (R,Y,B) and/or networked switching points from and sunrise/sunset relative timings
Central Control Station instantaneously. - Data logging with historical data repositories and
Ÿ Automatic Street light control throughout the year on basis of precise storage in SD card
sunrise and sunset time depending on the geographical location (Longitude - Energy Metering data acquisition, analysis and
& Latitude) of the switching point. reporting
Ÿ Automatic setting of dawn dusk timings as per Longitude & Latitude. - Alarming and flexible reporting
- Failure detection and reporting
Ÿ Built in Astronomical feature with high precision Real Time Clock (RTC).
- SMS integration
Ÿ Reporting of energy metering and failure information to central control - SMTP EMAIL support
station at variable time intervals.
Ÿ Serial and Telnet console user interface for advanced
Ÿ Provides various WAN communication IP network such as 3G/4G Cellular, co nf i g u rat i o n s et u p , d e b u g n et wo r k i n sta l l at i o n
GSM/GPRS, 10/100 Ethernet, 802.11 b/g/n 2.4GHz Wi-Fi connectivity to commissioning, scheduling, alarming and data logging.
Central control station for the secured remote monitoring and control
Ÿ Event and fault Logging.
system with Devtech group CMS Software (Standalone/Web or Cloud
based server application). Ÿ Optionally provided with UPS back up for around 6 to 8
hours.
Ÿ Optically Isolated dry contact digital Inputs for the external sensor interface
like ambient light, occupancy motion or traffic detection weather sensors. Ÿ Instant fault reporting via SMS along with fault information &
details of location.
Ÿ High-Voltage, High-Current rating SPST relays for driving 3 Phase, 4 pole
contactors. Ÿ Network time synchronization with server.
Ÿ Self-protection from short-circuit, over voltage, over load, 40KA surge Ÿ Quiet, cool operation and environmentally friendly.
protection and anti- theft alert. Ÿ IP65/66 Enclosure Cabinet with CAM lock key arrangement
Ÿ Isolated RS485 MODBUS RTU port. (Rittal make).
Ÿ Customized solutions are available as per requirement from design to Ÿ Comprehensive warranty.
delivery for OEM's. Ÿ Available in single phase and three phase models with ratings
Ÿ Equipment is equipped with Theft/Tamper protection starting from 5KVA upto 50KVA (Higher KVA ratings are
available on request ).
Ÿ Alarm/ Alert details are sent to the registered users
Ÿ Dashboard has facility to select controllers based on
Zones/Groups
Ÿ SD card facility to download the data at field level
Ÿ LCD display for parameter display
System Architecture

HID/LED Luminaires HID/LED Luminaires HID/LED Luminaires

Devtech Devtech
Group CMS Group CMS Devtech
Unit Unit Group CMS
Feeder Pillar Feeder Pillar Devtech Group CMS Unit
Unit
Feeder Pillar

Central Server
Secured WAN IP network
GSM/GPRS/3G/4G/
Ethernet/Wi-Fi
Access Router

Data Centre

Authorized users
over HTTP or HTTPS
End users Communication Web Application
Server Server
Database

All specification are subject to change without prior notice, visit website for updated documents. | Website : www.DevtechM2M.com
www.DevtechM2M.com
GROUP CMS Controlling/Setting/Monitoring/Protection or Alarm/SMS Alert
(Using function) Description
1. Group & Individual Phase (R,Y,B) 2. Setting of Group CMS Unit 3. Resetting the Group CMS Unit
Controlling ON/OFF based on Ad-Hoc MAC ID based on Ad-hoc request or
/Setting request RTC (Real Time Clock) Watchdog timer

ON/OFF time scheduling Update Time Interval


based on Astronomical or GPS Longitude & Latitude
RTC (Real Time Clock)
1. Voltage (V) 2. Current (A) 3. Active Power (kW)
R-phase Voltage R-phase Current R-phase Active Power
Y-phase Voltage Y-phase Current Y-phase Active Power
Monitoring B-phase Voltage B-phase Current B-phase Active Power
Total Active Power

4. Reactive Power (kVAR) 5. Apparent Power (kVA) 6. Power Factor (PF)


R-phase Reactive Power R-phase Apparent Power R-phase PF
Y-phase Reactive Power Y-phase Apparent Power Y-phase RF
B-phase Reative Power B-phase Apparent Power B-phase PF
Total Reative Power Total Apparent Power System PF

7. Cumulative Parameters 8. Other Parameters 9. Status Parameters


Metering kWh Meter Serial Number Current Status of Group CMS
Metering kVAh Mains Power ON/ OFF Hours Unit
Lighting luminaires (HID/LED) Current RTC time of Group
running Hours CMS unit
Number of Operational/Non
operational lights on each
phase (R,Y,B)
1. High/Low Voltage Alarm, Cut-Off & 2. High/Low Current Alarm, Cut-Off & 3. Low Power Factor Alarm & SMS
SMS Alert for each phase (R,Y,B) SMS Alert for each phase (R,Y,B) Alert for each phase (R,Y,B)
Protection/
Alarm/ 4. Phase Overload Alarm, Cut-Off & 5. Power Failure Alarm& SMS Alert 6. Contactor Failure/MCB Failure
SMS Alert SMS Alert Alarm & SMS Alert
7. Theft Alarm & SMS Alert 8. Group Failure Alarm & SMS Alert 9. No output supply Alarm & SMS
Alert

Connection Diagram

Devtech Group CMS Panel Wiring Diagram Devtech Group CMS Panel Wiring Diagram
Model : 10kVA 1Ø Model : 30kVA 3Ø
R-Ph
R-Ph

Devtech RTU for Group CMS

Operating Input Voltage 90 ~ 305V AC


DEVTECH 12V/2A Devtech RTU for Group CMS

12V/2A
Y-Ph
Mains Frequency 50 ~ 60Hz Operating Input Voltage 90 ~ 305V AC
DEVTECH
Power Consumption

Ambient Temperature
<15W

-10 to +55C
0

RTU Adapter Y-Ph


Mains Frequency
Power Consumption
50 ~ 60Hz
<15W
Adapter
Relative Humidity
(non-condensing)
0
10.....90% RH max @ 50C Ambient Temperature

Relative Humidity
-10 to +55C
0

0
10.....90% RH max @ 50C
(non-condensing)
RTU
B-Ph GPRS
B-Ph GPRS

Rs232 Tx- Tx+

1 Phase
Energy Meter 3 Phase
Rs232

240 VAC, Energy Meter 240 VAC,


GIC Time GIC Time
6A, 2P Switch 6A, 2P Switch
CAM Switch CAM Switch
Nout
Lout
Nin
Lin

Nout
2out

RS485
3out
1out

Nin
1in

2in

3in

P N
Tx-
Tx+
DEVTECH Surge Guard -DSG 1520

RoHS S
63A,SP 63A,3P
DEVTECH Surge Guard - DSG 1520

63A,3P MCB MCB,10KA


A Contactor 10KA Bypass
63A,1P 63A,1P Typ
63A,2P Switch
MCB MCB,10KA
Contactor
20kV/10kA

Bypass
S S

10KA
RoHS RoHS
20kV/10kA

Switch

RoHS S

Note : Note :
1. Under Normal Operation, Cam Switch will be in 1 position. 1. Under Normal Operation, Cam Switch will be in 1 position.

Earth 2. If any problem in the System (Devtech RTU) operation, 2. If any problem in the System (Devtech RTU) operation,
Terminal Terminal Turn the Cam switch knob to 0 position & then 2 position. Terminal Turn the Cam switch knob to 0 position & then 2 position.
Terminal Terminal
Block Block Block
3. For bypass mode, 3. For bypass mode, Block
L N L N Earth L1 L2 L3 N L1 L2 L3 N
a. MCB (63A, SP) should be made OFF & Turn the Cam switch knob to 0. a. 3 Nos. MCBs (63A, SP) should be made OFF & Turn the Cam switch knob to 0.
1 Phase, AC 1 Phase, AC Terminal 3 Phase, AC 3 Phase, AC
b. After that Bypass Switch can be made ON manually. b. After that Bypass Switch can be made ON manually.
Mains Supply Outgoing Supply Mains Supply Outgoing Supply

All specification are subject to change without prior notice, visit website for updated documents. | Website : www.DevtechM2M.com
www.DevtechM2M.com
Technical Specifications
1Ø AC 90 ~ 305V (for 1- phase 2 wire system)
Operating Input Voltage
3Ø AC 320 ~ 575V (for 3 - phase 4 wire system)
Mains Frequency 50 ~ 60 Hz
Power Consumption <15 Watts
Installation Type Pole Mount or Wall Mount
Ambient Temperature -40 to +55°C
Relative Humidity 10 … 90% RH max @ 50°C (non-condensing)
RTC / Calendar 100 Years Calendar, RTC ( Real Time Clock) with Battery Backup
GPRS Quad band 850/900/1800/1900MHZ @GSM
GPRS multi-slot class 12, coding scheme CS-1 to 4
GSM/ GPRS
Packet data up to 85.6K bps
GPRS Certificates: CE/ GCF/ FCC/ PTCRB/ IC/ANATEL/ NORM/ COFETEL/ ICASA/ NCC/ China TA
WLAN : IEEE 802.11 b/g/n
Frequency : 2.4 GHz ~ 2.4835 GHz
Transmitting Power : Up to 16dBm
WLAN (Wi-Fi) RF Data rate : 1 Mbps to 72.22 Mbps
Receiver Sensitivity : -93dBm
Antenna : On board Antenna, external antenna
Authentication : WEP64/WEP128/TKIP/AES, WEP/WPA-PSK/WPA2-PSK
Input
Rated Voltage : 3 x 240V
Current Rating : 10-60A
Starting Current : 0.2% of Ib
Frequency : 50 Hz ± 5%
Power factor : Zero lag - unity - Zero lead
AC 3Ø, 4 Wire static
Output
Energy Meter
Display : 10 digit Backlit LCD display
Communication : RS-485 MODBUS RTU
Phase-wise Relay output
(Optional) : 3 X Max 60A, 230 V AC contact rating
Enclosure : Engineering plastic
Class of Accuracy : Class 1.0
ISI marking/Standard : IS 13779:1999
Configuration : Single door, unibody construction, gland plate in the enclosure base, right
hand door hinge,with cam lock, foamed-on door gasket and mounting panel
Material : Sheet steel
Cabinet Enclosure Protection ratings : IP 65/66, IK10
(Rittal make) Finish
Enclosure and door : Dipcoat-primed,powder-coated on the outside in textured RAL 7035
(light gray)
Mounting panel : Zinc-plated
Switch Gear (Schneider MCB : C curv, Breaking Capacity Icn=10kA
/Legrand make) Contactor : 4 Pole, 4 NO Contacts
Display LCD
Product Dimension 380mm x 600mm x 210mm
(HXWXD)

All specification are subject to change without prior notice, visit website for updated documents.

2
USA : DEVTECH M2M LLC - 9582 Topanga Canyon Blvd, Chatsworth CA 91311

D VT CH Enabling Smart Cities


SINGAPORE :
INDIA :
DEVTECH M2M PTE LTD - 91, Alps Avenue, #03-01, Singapore 498787
DEVTECH M2M LTD - SAVA House, Off New Airport Road, Viman Nagar, Pune – 411014 India

E-mail:
All specification are subject [email protected]
to change | Website:
without prior notice, visit website www.DevtechM2M.com
for updated documents. | Website : www.DevtechM2M.com