Catalog EcoStruxure Control Expert and OPC Software
Catalog EcoStruxure Control Expert and OPC Software
www.schneider-electric.com
Modicon
Discover Modicon
Industrial Edge control for IIoT
Modicon IIoT-native edge controllers manage complex
interfaces across assets and devices or directly into the cloud,
with embedded safety and cybersecurity. Modicon provides
performance and scalability for a wide range of industrial
applications up to high-performance multi-axis machines and
high-available redundant processes.
• Up-to-date catalogs
> With just 3 clicks, you can access the Industrial Automation • Embeded product selectors,360° pictures
• Optimized search by commercial references
and Control catalogs, in both English and French
> Consult digital automation catalogs at Digi-Cat Online
> Find the right Training for your needs on our Global website
> Locate the training center with the selector tool, using this link
General contents
Companion software. . . . . . . . . . . . . . . . . 2
10
In this catalog, each time words which refer to Safety without precision, must be
understood according to “Functional Safety”: IEC61508 & IEC61511.
1
Schneider Electric’s IoT-enabled, plug-and-play, open,
secure, interoperable architecture and platform, in Industries,
Infrastructures, Data Centers, and Buildings.
Innovation at every level Dedicated architectures and IoT Cybersecurity solutions Enhanced safety
EcoStruxure is based on a three-tiered We tailor our solutions in the form of dedicated Robust cybersecurity protection is a must, and With the release of M580 Safety, Schneider
technology stack delivering innovation at every reference architectures for plants: Schneider Electric’s solutions can deliver it, Electric further expands the EcoStruxure
level, from connected products to edge control b Management systems regardless of business type or industry. platform.
and apps, analytics, and services. The vendor-agnostic services provided by This consolidates our position as one of the
b Power systems
Together with our hybrid segments approach, our skilled professionals help to protect your most trusted industrial safety vendor, with
b Data center systems thousands of Modicon and Triconex safety
this enhances your value around safety, entire critical infrastructure. We help to assess
reliability, operational efficiency, sustainability, b Industrial plant and machine systems your risk, implement cyber-specific solutions, systems protecting the most critical industrial
and connectivity across 6 domains of expertise: b Smart grid systems and maintain your onsite defenses over time, processes globally.
b Power b Plant while integrating appropriate IT policies and
The Industrial Internet of Things (IIoT) gives an requirements.
b IT b Grid additional boost to technologies. That's why
we provide our customers with an IoT-enabled This is our difference and your advantage.
b Building
architecture and platform offering simple,
b Machine reliable, productive, and cost-efficient solutions.
for Plant
EcoStruxure™Architecture
Apps,
Analytics & Field Services
Services
End-to-end Cybersecurity
Harmony Modicon
Edge
Control
Advanced operator Industrial Edge EcoStruxure EcoStruxure EcoStruxure EcoStruxure EcoStruxure SCADA Systems
interface, Edge Box Control for IIoT Foxboro DCS Triconex Safety
Automation Expert Process Expert Control Expert
and industrial relays Systems
Connected
Products
Variable speed drives Innovative & connected Comprehensive, robust Process Pushbuttons and
and soft starters solutions for motor starters portfolio of power distribution Instrumentation Signalling
Sensors and RFID
and motor control centers
*The Schneider Electric industrial software business and AVEVA have merged to trade as AVEVA Group plc, a UK listed company. The
Schneider Electric and Life is On trademarks are owned by Schneider Electric and are being licensed to AVEVA by Schneider Electric.
10
1/0
Contents 1 - EcoStruxure Control Expert
5
Modicon M580 Safety, Premium and Quantum automation platforms....... page 1/15
v Modifying the program with the PAC in RUN mode................................. page 1/16
v Cross-references function...................................................................... page 1/16
v Import/export function............................................................................. page 1/16
v Application converters............................................................................ page 1/17
v Operating system update utilities............................................................ page 1/17
v Online modification of the configuration (CCOTF).................................. page 1/17
6
v Process control in machines................................................................... page 1/18
v Communication drivers........................................................................... page 1/19
v Upgrade kits for Concept, PL7 Pro and ProWORX software................... page 1/19
v Composition and Windows OS compatibility........................................... page 1/19
v EcoStruxure Control Expert update........................................................ page 1/19
7
v How-to Tutorials...................................................................................... page 1/19
1/1
Selection guide Software
EcoStruxure Control Expert
Small, Large, Extra Large
EcoStruxure Control Expert programming software for Modicon M340 M, Modicon M580 M5, Modicon M580 Safety M5S, EcoStruxure Control Expert programming software for Modicon M340 M , Modicon M580 M5, Modicon M580 Safety M5S,
Modicon Momentum MM, Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms Modicon Momentum MM, Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms
1 IEC 61131-3
languages
Instruction List (IL)
Ladder (LD)
M - MM - D
M - MM - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
1
Structured Text (ST) M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Function Block Diagram (FBD) M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Sequential Function Chart (SFC)/Grafcet M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Ladder Logic Language LL984 M - MM M - M5 - MM - Q M - M5 - MM - Q
4 4
Hot Standby PAC redundant system M5 - P (TSXH5724M/44M) - D M5 - P (TSXH5724M/44M) - Q (140CPU67160) - D
System and application diagnostics M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Bus and network configuration to slave devices M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
(Modicon distributed I/O, etc.)
Topology Multi-controller architecture
Manager Network consistency
Client-server architecture
5 Debugging
System diagnostics
PLC simulator M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
5
and display Hypertext link animations in graphic languages M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
services
Step-by-step execution, Breakpoint, Watchpoint M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Trending tool M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Operator screens, Animation tables M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
6 6
Diagnostics viewer M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Other Creation of hyperlinks M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
services XML/XVM import/export M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Application converters (Modsoft, Concept, ProWORX, PL7) M M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Utilities for updating PACs and Advantys operating system M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Communication drivers for Modicon platforms M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
Unity Pro servers - Openness (OFS, third-party tools) M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
7 Online modification of the configuration
Online modification of the program M - MM - Q
M5 - Q
M - M5 - MM - P - Q
M5 - Q
M - M5 - MM - P - Q
7
Importing of applications (Modsoft, Concept, ProWORX) M - MM M - MM - Q M - M5 - MM - Q
written in LL984 language
Data dictionary, Dynamic exchange with SCADA through OFS M - MM - D M - M5 - MM - P - Q - D M - M5 - P - Q - D
Static exchange via XML/XVM export files M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D
8 8
Compatible Modicon M340 CPUs M All models All models All models
Modicon Modicon M580 CPUs M5 – BMEP5810/5820/5830/BMEH5820 All models
platforms
Modicon M580 Safety CPUs M5S – BMEP582040S/BMEH582040S (with M580 Safety Add On All models (with M580 Safety Add On CEXADSSCZZpPMZZ)
CEXADSSCZZpPMZZ)
Modicon Momentum CPUs MM 171CBU78090/98090/98091 171CBU78090/98090/98091 171CBU78090/98090/98091
Premium CPUs P – TSXP57104M/1634M/154M, TSXP57204M/2634M/254M All models
TSXP57304M/3634M/354M, TSXP574634/454M, TSXH5724/44M
Quantum CPUs Q – 140CPU31110, 140CPU43412U, 140CPU53414U All models
9 Quantum Safety CPUs S – – – 9
Compatible Modicon distributed I/O D STB, OTB, TM7, ETB, Momentum STB, OTB, TM7, ETB, Momentum STB, OTB, TM7, ETB, Momentum
EcoStruxure Control Expert software name EcoStruxure Control Expert Small EcoStruxure Control Expert Large EcoStruxure Control Expert Extra Large
EcoStruxure Control Expert software package CEXSPUCZSpPMZZ CEXSPUCZLpPMZZ CEXSPUCZXpPMZZ
10 10
Software license, see page 1/21 1/22 1/23
1/5
1/2 1/5
1/3
Selection guide Software
EcoStruxure Control Expert
Extra Large with Topology Manager and M580 Safety
EcoStruxure Control Expert programming software for Modicon M340 M, Modicon M580 M5, Modicon M580 Safety M5S, Unity Pro programming software for Modicon M340 M , Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM,
Modicon Momentum MM, Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms Premium P, Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms
1 IEC 61131-3
languages
Instruction List (IL)
Ladder (LD)
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - MM - P - D - Q
M - MM - P - D - Q - QS
1
Structured Text (ST) M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D- Q
Function Block Diagram (FBD) M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Sequential Function Chart (SFC)/Grafcet M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q
Ladder Logic Language LL984 M - M5 - M5S - MM - Q M - M5 - M5S - MM - Q M - M5 - MM - Q M - MM - Q
Programming Multitask programming (Master, fast and event-triggered) M - M5 - M5S - MM (master task only) - P - Q - D M - M5 - M5S - MM (master task only) - P - Q - D M - M5 - MM (master task only) M - MM (master task only) - P - D - Q
2 services
Multitask programming (Master, fast, auxiliary and M5 - M5S - P (TSXP575•) - Q (140CPU651/671) - D M5 - M5S - P (TSXP575•) - Q (140CPU651/671) - D
-P-Q-D
M5 -P (TSXP575•) - Q (140CPU651/671) - D P (TSXP575•) - D - Q
2
event-triggered) (140CPU651/671)
Functional view and function modules M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Program units M - M5 - M5S M - M5 - M5S M - M5 - M5S
DFB editor and instances M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
DDT compound data editors M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q
5 Debugging
System diagnostics
PLC simulator M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
5
and display Hypertext link animations in graphic languages M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
services
Step-by-step execution, Breakpoint, Watchpoint M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Trending tool M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Operator screens, Animation tables M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Diagnostics viewer M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
6 Other
services
Creation of hyperlinks
XML/XVM import/export
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - MM - P - D - Q - QS
M - MM - P - D - Q - QS
6
Application converters (Modsoft, Concept, ProWORX, PL7) M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q
Utilities for updating PACs and Advantys operating system M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q
Communication drivers for Modicon platforms M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Unity Pro servers - Openness (OFS, third-party tools) M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Online modification of the configuration M5 - M5S - Q M5 - M5S - Q M5 -Q
7 Online modification of the program
Importing of applications (Modsoft, Concept, ProWORX)
M - M5 - M5S - MM - P - Q
M - M5 - M5S - MM - Q
M - M5 - M5S - MM - P - Q
M - M5 - M5S - MM - Q
M - M5 - MM - P - Q
M - M5 - MM - Q M - MM - Q
7
written in LL984 language
Data dictionary, Dynamic exchange with SCADA M - M5 - M5S - P - Q - D M - M5 - M5S - P - Q - D M - M5 -P - Q - D M - P - D - Q - QS
through OFS
Static exchange via XML/XVM export files M - M5 - M5S - MM - P - Q - D M - M5 - M5S - MM - P - Q - D M - M5 - MM - P - Q - D M - MM - P - D - Q - QS
Compatible Modicon M340 CPUs M All models All models To be used only for Quantum safety
8 Modicon
platforms
Modicon M580 CPUs M5
Modicon M580 Safety CPUs M5S
All models
All models
All models
All models –
8
Modicon Momentum CPUs MM 171CBU78090/98090/98091 171CBU78090/98090/98091
Premium CPUs P All models All models
Quantum CPUs Q All models All models
Quantum Safety CPUs S – –
Compatible Modicon distributed I/O D STB, OTB, TM7, ETB, Momentum STB, OTB, TM7, ETB, Momentum
9 EcoStruxure Control Expert software name EcoStruxure Control Expert Extra Large with M580 Safety Add-on EcoStruxure Control Expert Extra Large EcoStruxure Control Expert Extra Large Unity Pro Extra Large Safety 9
with Topology Manager and M580 Safety (1) with Topology Manager Add-on (1) v7.0 for Quantum
EcoStruxure Control Expert software package CEXADSCZZpPpZZ CEXSPMCZXpPMZZ CEXADMCZZppZZ, CEXADMFZZSPAZZ UNYSPUXppV1X
Software license, see page 1/23 1/24 1/25 –
(1) Available Q1 2021.
10 10
1/4
1/6 1/6
1/5
Presentation Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Presentation
This catalog describes EcoStruxure Control Expert software V15, which is the latest
version available.
3
b Five IEC 61131-3 programming languages
b LL 984 programming language
b Device integration with FDT/DTM standard
b Integrated, customizable DFB library
b Topology Manager
b PAC-to-PAC communication
b PLC simulator on PC for program validation prior to installation
4
b Built-in tests and diagnostics
b Wide range of online services
b Cybersecurity
EcoStruxure Control Expert supports the new M580 Safety PACs, mixing process
and safety in a single project. It allows users to:
b Optimize engineering time
b Simplify programming with IEC61508 functions
5 b Facilitate maintenance
EcoStruxure Control Expert is available in two modes:
b Classic mode for single-controller architectures, with Topology Manager license
that can work in Topology Manager mode
b Topology Manager mode for multi-controller architectures
Topology Manager
6 EcoStruxure Control Expert V15 with the new Topology Manager offers a common
environment to design, engineer, commission, operate, and maintain a complete
plant. The multi-controller architecture in graphical tree representation makes the
design and deployment of entire multi-PAC systems, including the various types of
automation assets, very easy.
The intuitive design workflow (drag/drop, copy/paste) is created for the global
administration of complete architecture. A consistent update of the logical network
7 view with automatic assignment of IP address allows you to update a project easily,
reducing engineering maintenance and total lifecycle costs. During commissioning,
users will also be able to deploy one or a group of controllers/assets in one click,
thus reducing time and engineering costs.
10
1/6
Presentation (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Network consistency 2
Client-Server model The accuracy and consistency of the network design can be analyzed and
automatically validated with just one click. Detected errors or warnings are reported
with detailed instructions for easy correction.
System diagnostics
The system diagnostics provides live statistics for the entire plant during the
3
operation or commissioning phase. Detected errors are localized and analyzed in
real time. The intuitive interface also helps to easily visualize these detected errors
and resolve them quickly to boost efficiency.
4
Network consistency check PAC-to-PAC communication
The PAC-to-PAC communication is made flexible and easy with:
b Explicit messaging with READ_REMOTE and WRITE_REMOTE communication
function blocks. These blocks enable exchange of variables by using the name of
the variable between M580 and M340 PLCs.
b Implicit messaging with local slave being configured in Topology Manager and 5
checked for consistency
System diagnostics 6
8
Implicit messaging
Cybersecurity
READ_REMOTE
MyVar_PAC1 receive Schneider Electric constantly endeavours to maintain the security of its systems.
value from MyVar_PAC2
Security guidelines are available for our customers to help ensure their systems are
protected from attack.
The Modicon M340, M580, M580S, Premium, Momentum, and Quantum
WRITE_REMOTE
MyVar_PAC2 receive
value from MyVar_PAC1
automation platforms feature:
b Protection against remote programming changes via a password
9
b Option to enable or disable HTTP or FTP services
With the Modicon M580 automation platform:
Explicit messaging b Log of security events in the SYSLOG database
b Extended Ethernet services management (DHCP, etc.) can be set for each user
ur
Sec ity
in the Access Control List
b More secure IPSec communication between EcoStruxure Control Expert or 10
SCADA and PAC
1/7
Functions Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
FDT/DTM function
EcoStruxure Control Expert facilitates integration of fieldbus architectures into
1 engineering control systems using FDT/DTM technology:
b FDT (Field Device Tool) is the container which supports the device DTMs.
b DTM (Device Type Manager) is the configuration tool for devices with integrated
graphic interfaces. It contains the properties specific to each device.
In addition to the FDT/DTM standard, the software uses specific information from
the Master DTM created for the Profibus Remote Master (PRM) module, the HART
2 module, the Premium ISPY101 weighing module, Altivar process drive integration, and
the Modbus/TCP and EtherNet/IP network modules BMXNOC0401 and BMENOC03p1.
DTM editor (Modicon STB island) Use of the Master DTM allows EcoStruxure Control Expert to perform the following
actions:
b Manage the PAC I/O scan
b Create the application variables based on the description of the process objects
available from the connected DTM devices
3 b Manage synchronization with the PAC configuration
b Create a generic DTM from the description files (GSD or EDS)
The DTM configuration is stored in the PAC memory so that the application can be
DTM hardware catalog downloaded in its entirety. It is also saved in the PAC project file (STU), the archive
file (STA), and the full application exchange file (ZEF).
A third-party DTM can be installed in the DTM hardware catalog.
4 The DTM hardware catalog can be used to sort or filter the DTMs according to
various criteria such as device, vendor, groups or protocols.
The DTM Browser in EcoStruxure Control Expert:
b Displays the fieldbus topologies in a tree structure
b Allows the user to configure the DTM devices:
v add and delete DTMs
Programming languages
The five IEC 61131-3 compliant languages
The five graphical or textual languages available in EcoStruxure Control Expert are
LL984 language
LL984 (Ladder Logic 984) language enables migration from legacy Modicon ranges.
10 FBD language editor
It is used to program Modicon M580, Modicon M580 Safety, Modicon M340,
Momentum, and Quantum automation platforms.
1/8
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Program units
Program units are compliant with Program Organization Units (POUs) as defined in
standard IEC 61131-3. 1
Program units are autonomous programming entities (only available for Modicon
M580 and M340). Program units allows easy duplication and clear organization of a
program with local and public variables.
-m
m
e-to ark Common functional Safety architecture on Modicon M580 (1)
4
Presentation
et
Ti
6
All X80 safety I/O are managed through safety tasks, and standard and non-
interfering X80 modules are managed in other tasks. This means it is possible to mix
safety and standard X80 modules in the same M580 Safety PAC.
Data editor
PROCESS and SAFE data are managed in a distinct M580 memory area.
EcoStruxure Control Expert allows users to easily manage:
b Exchange of data between process and safe areas of the project in “Data Editor”
b Process data in the “PROCESS Data Editor”
8
b Safe data in the “SAFE Data Editor”
10
1/9
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Data editor
The data editor provides a single tool for performing the following editing tasks:
1 b Declaration of data including variables and function blocks (declaration of their
type, instances, and attributes)
b Use and archiving of function block data types in different libraries
b Hierarchical view of data structures
b Searching, sorting, and filtering of data
b Creation of a hyperlink to access a description from any variable comment
2 Data editor
The data is displayed in four tabs:
b “Variables” tab for the creation and management of the following data instances:
bits, words, double words, inputs/outputs, tables, and structures
b “DDT Types” tab for the creation of derived data types (tables and structures)
b “Function Blocks” tab for the declaration of EFBs and DFBs
b “DFB Types” tab for the creation of DFB user function block data types
The data editor columns can be configured (number of columns, order). The
attributes associated with a variable can be displayed in a properties window.
Data properties
4 This editor can be accessed at any time during programming by selecting variables
for data modification or creation.
Once created and saved in the library, these user function blocks can be reused as
easily as EFBs (Elementary Function Blocks).
Design
The user function blocks can be used to structure an application. They are used
6 when a program sequence is repeated several times in the application or for freezing
a standard programming routine. They can be read-only or read/write. They can be
exported to other EcoStruxure Control Expert applications.
7
b facilitates program debugging (variables handled by the DFB are identified in the
data editor)
b enables the use of private variables specific to the DFBs, which are independent
of the application
8
public and private internal variables) and a comment to it via the data editor.
b The code is created in one or more sections of the program, with the following
languages selected according to requirements: Structured Text, Instruction List,
Ladder, or Function Block Diagram (ST, IL, LD, or FBD).
b The DFB can be stored in a library with an associated version number.
b A DFB instance is created in the data editor or when the function is called in the
program editor.
b This instance is used in the program in the same way as an EFB (the instance can
9 Use within the program be created from within the program).
10
1/10
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
The “Base Lib” library, which covers standard automation functions, is supplemented
by other, more application-specific libraries and platform-specific functions:
b Communication library, providing an easy means of integrating communication
programs from PACs with those used by HMIs from the PAC application program.
Like other function blocks, these EFBs can be used in any language to exchange
4
data between PACs or to deliver data to be displayed on an HMI.
b Process control library. The CONT_CTL library can be used to set up process-
specific control loops. It offers controller, derivative, and integral control functions
and additional algorithms, such as EFBs for calculating mean values, selecting a
maximum value, detecting edges, or assigning a hysteresis to process values, etc.
b Diagnostics library, which can be used to monitor actuators and contains EFBs
for active diagnostics, reactive diagnostics, interlocking diagnostics, permanent
5
process condition diagnostics, dynamic diagnostics, monitoring of signal groups, etc.
b I/O management library, providing services to handle information exchanged
with hardware modules (formatting data, scaling, etc.).
b Motion Function Block library, containing a set of predefined functions and
structures to manage motion controlled by drives and servo drives connected on
CANopen.
b Motion library for motion control and fast counting.
6
b System library, which provides EFBs for the execution of system functions,
including: evaluation of scan time, availability of several different system clocks, SFC
section monitoring, display of system status, management of files on the memory
cartridge of the Modicon M340 processor, M580 processor, etc.
b Finally, a library named “obsolete”, containing the function blocks used by legacy
programming software needed to perform application conversions.
7
Management of user standards
Users can create libraries and families in order to store their own DFBs and DDTs.
This enhancement allows users to take advantage of programming standards
adapted to their needs, along with version management. This means that it is
possible to:
b Check the version of the elements used in an application program against those
stored in the library
8
User libraries b Perform an upgrade, if necessary
10
1/11
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Debugging tools
EcoStruxure Control Expert software offers a complete set of tools for debugging
1 Modicon M340, M580, M580S, Momentum, Premium, or Quantum applications. A
tool palette provides direct access to the main functions:
b Dynamic program animation
b Setting of watchpoints or breakpoints (not authorized in event-triggered tasks)
b Step-by-step program execution. A function in this mode enables section-by-
section execution. Instruction-by-instruction execution can be launched from the
previous breakpoint. Three execution commands are therefore possible when the
2 element to be processed is a subroutine (SR) or DFB user block instance:
v Step Into: This command is used to move to the first element of the SR or DFB.
Debugging tools: Dynamic animation/adjustment v Step Over: This command is used to execute the entire SR or DFB.
v Step Out: This command is used to move to the next instruction after the SR or
DFB element.
b Independent execution of the master (MAST), fast (FAST), auxiliary (AUX), and
event-triggered (EVTi) tasks
3 Animation of program elements
Dynamic animation is managed section-by-section. A button on the toolbar is used to
activate or deactivate animation for each section.
When the PAC is in RUN, this mode can be used to simultaneously view:
b The animation of a program section, regardless of the language used
Animation table
Tables containing the variables of the application to be monitored or modified can be
created by data entry or initialized automatically from the selected program section.
The tables can be stored in the application and retrieved from there at a later date.
5 EcoStruxure Control Expert can be used to save, import, and export Animation
tables with predefined set values. As it allows population of set values along with
current values and vice versa in the PAC, Animation tables can be used as templates
to make the application easier to tune.
10
1/12
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
PLC simulator
1
EcoStruxure Control Expert’s integrated simulator can be used to test the application
program for Modicon M340, M580, M580S, Momentum, Premium, or Quantum
automation platforms from the PC terminal without having to connect to the
processor. The functions provided by the debugging tools are available for
Simulator control panel debugging the master, fast, and auxiliary tasks.
As the simulator does not manage the PLC I/O, animation tables can be used to
simulate the state of inputs by forcing them to 0 or 1.
2
The simulator can be connected to third-party applications via an OPC server with
OFS (OPC Factory Server) software.
Trending tool
The trending tool allows easy monitoring of variables by detecting operating
problems or improving process performance. You can select any variable in your
application and start acquisition, save records, and analyze records with integrated
tools or Excel. The PAC mast scan can scan up to 16 variables.
3
7
b Program
b Animation tables and cross-references
b Runtime screens
10
1/13
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Integrated diagnostics
Diagnostics integrated in Modicon M340, Modicon M580, Modicon M580 Safety, Premium, and Quantum
automation platforms
1 Presentation
Vijeo Citect
Thin client Magelis iPC Higher-level
MES
2
Processor In-rack I/O Distributed
for system modules I/O modules
bits and on Ethernet Ethernet TCP/IP
words or I/O buses
3 Vijeo Designer
Cell level
Application diagnostics
Magelis Terminal
4
RUN ERR
I/O MB1
ETH ETH
100 STS
ETH LNK/ACT
Quantum,Premium, M340,
M580, M580S, Momentum Machine level
EcoStruxure
PC Control Expert
5 The diagnostics offer for Modicon M340, M580, M580S, Momentum, Premium, and
Quantum platforms is based on the following three components:
b System diagnostics
b DFB and EFB diagnostic function blocks (for system and application diagnostics)
b Error message display system, called viewers, supplied as a standard component
of Magelis terminal, Vijeo Citect supervisory software and EcoStruxure Control
System diagnostics
The system diagnostics for the Modicon M340, M580, M580S, Momentum, Premium,
and Quantum platforms support the monitoring of system bits/words, I/O modules,
and activity times (minimum/maximum) of SFC steps. By simply choosing the relevant
option during application configuration, any event will generate time-stamped
With EcoStruxure Control Expert integrated diagnostics, this function can be used to
perform first-level diagnostics of the elements in the configuration, up to and
including each I/O module channel.
9 Configuration level
Module level
1/14
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
5
Import/export function
The import/export function available in EcoStruxure Control Expert supports the
6
following operations from the structural and functional project views:
b Via the import function, reuse of all or part of a previously created project in the
current project
b Via the export function, copying of all or part of the current project to a file for
subsequent reuse
The files generated during export are generally in XML format (1). However, in
Data export shortcut menu addition to XML, variables can be exported and imported in the following formats:
b .xvm format compatible with OFS data server software
b source format, in an .scy file compatible with PL7 development software
7
b text format with separator (Tab) in a .txt file for compatibility with any other system
During an import, a wizard can be used to reassign data to new instances of:
b DFB function blocks
b DDT data structures
b simple data
In addition, when a functional module is imported, the data associated with
8
animation tables and runtime screens is also reassigned.
EcoStruxure Control Expert includes an Excel import/export tool that makes it easy
to manage the variables using an XML export file in Excel.
(1) XML language is an open, text-based language that provides structural and semantic
information. 10
1/15
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Application converters
EcoStruxure Control Expert’s integrated conversion tools can be used to convert
1 applications created with ModSoft, ProWorX, Concept, and PL7 programming
software to EcoStruxure Control Expert applications.
3
essential to test or debug all converted applications.
PL7/EcoStruxure Control Expert converter (Premium PAC and Atrium slot PAC)
This conversion is performed with a PL7 application V4 or later (Premium PAC or
Atrium slot PAC). In order to perform the conversion, the source file (complete
application or user function block) should be exported to PL7.
The conversion procedure is similar to that of the Concept conversion described above.
4 Note: Applications created with Concept, Modsoft and ProWORX can be converted to LL984.
Please contact our Customer Care Center.
5 The complete conversion process relies on the use of EcoStruxure Control Expert.
UMAC is available in 2 sizes: Lite and Standard. UMAC Lite is free and downloadable
from our website www.schneider-electric.com. UMAC Lite allows the existing
configuration to be retained while UMAC Standard adapts the code to Modicon M580.
6 The OS-Loader software is designed for updating operating systems on Premium and
Quantum platforms. It is supplied with EcoStruxure Control Expert software.
It is used to upgrade EcoStruxure Control Expert processors and modules as well as
to upgrade PL7 or Concept processors and modules to make them compatible with
EcoStruxure Control Expert.
9 This function, also called Change Configuration On The Fly (CCOTF), is used to modify
the Modicon M580 or Modicon Quantum configuration online (application in RUN mode):
b Addition or removal of discrete or analog I/O modules
b Modification of configuration parameters of discrete or analog I/O modules
(already present or newly installed)
10
the three types of I/O architecture (local, RIO, DIO) using version 5 of EcoStruxure
Control Expert, and for Hot Standby processors using version 4.1 or higher
of EcoStruxure Control Expert. The CCOTF function should first be validated in
the EcoStruxure Control Expert configuration screen. A confirmation screen appears
when the configuration has been modified online.
Configuration screen
1/16
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Programmable process control
4
b process value processing
b output value processing
b setpoint management
7
TC18_OUT RCPY PARA_C TC18_PARA FF
TC18_START START TC18_OUT RCPY (series/parallel)
TC18_PREV PREV 1 MAN_AUTO MA_O
TC_PARA PARA PARA INFO PIDFF Complete PID controller: PID algorithm with a parallel or mixed
TR_I
TR_S
TRI TR_I
TR_S
STATUT structure (series/parallel)
TRS
INFO TC2_OUT OUT OUT TC2_OUT AUTOTUNE Automatic tuner setting for the PIDFF (complete PID) controller or
STATUS
the PI_B (simple PI) controller
MS v Identification using Ziegler Nichols type method
TC2_OUT IN
FORC
v Modeling based on first-order process
v Building of control parameters with criterion for prioritizing
8
MA_FORC
MAN_AUTO OUTD
PARA
either the reaction time to disturbance (dynamic) or the stability
MA_O
TR_I STATUT of the process
TR_S
TC18_OUT OUT OUT TC18_OUT IMC Model-based controller. The model is a first-order model with
delay. This corrector is useful:
Example: PID controller with MS manual control v When there are serious delays compared with the main time
constant of the process; this scenario cannot be satisfactorily
resolved by standard PID process control.
v For regulating a non-linear process IMC can handle any stable
SAMPLETM
aperiodic process of any order.
Control of controller startup and sampling 9
STEP2 Simple two-position controller
STEP3 Three-position controller for temperature regulation
Mathematical functions
COMP_DB Comparison of two values, with dead zone and hysteresis
10
K_SQRT Square root, with weighting and threshold, useful for linearization
of flow measurements
MULDIV_W Weighted multiplication/division of 3 numerical values
SUM_W Weighted summing of 3 numerical values
1/17
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Programmable process control
2 SAH
HYST_XXX
Detection of a rising edge
Detection of high threshold with hysteresis (1)
INDLIM_XXX Detection of high and low thresholds with hysteresis (1)
3 PWM1
SERVO
Control via pulse width modulation
Control for servo motors
SPLRG Control of two Split Range actuators
Setpoint management
RAMP Ramp generator, with separate ascending and descending ramps
RATIO Ratio controller
Debugging, operation
All EcoStruxure Control Expert ’s standard debugging services (see page 1/11) are
available. In particular, the PLC simulator can be used to check correct execution of
6 processing offline.
Compatibility
The CONT_CTL control function block library is available in all versions of
EcoStruxure Control Expert. It is compatible with processors in the Modicon M340,
Modicon M580, Modicon M580 Safety, Modicon Momentum, Premium, and
7 Quantum ranges.
8 Resources
The technical documentation provides many examples of how to set up
programmable process control function blocks in FBD, LD, IL, and ST languages.
The techniques for adjusting process control loops are described in the
9
EcoStruxure Control Expert online help and also the document available in
www.schneider-electric.com.
(1) XXX according to the type of variable: DINT, INT, UINT, UDINT, REAL.
10
1/18
Functions (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with
Topology Manager and M580 Safety
Communication drivers
The most commonly used communication drivers for Modicon M340, M580, M580S,
Momentum, Premium, and Quantum platforms are installed at the same time as the
EcoStruxure Control Expert software.
1
EcoStruxure Control Expert also includes the following drivers, which can be
installed as required (1):
Protocol - Hardware Windows® 7 Windows® 10
2
32-bit and 64-bit editions 32-bit and 64-bit editions
Fip adaptor - CUSBFIP
Modbus Serial - COM port
PCIway - Atrium TPCI57 PCI card
Uni-Telway - COM port
USB for high end PLC
XIP - XWay on TCP/IP
3
Driver available Driver not available
How-to Tutorials
The EcoStruxure Control Expert has a dedicated YouTube channel showcasing
videos that help you easily navigate and work with the software. It includes videos
on topics like configuration, installation, testing, software features, etc. To explore 8
more, click on the following link:
1/19
References Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with Topology
Manager and Safety
Licenses are delivered separately and are available in paper format or digital
E-license format (delivered by email).
3
b EcoStruxure Control Expert Large (see page 1/22)
b EcoStruxure Control Expert Extra Large (see page 1/23)
b EcoStruxure Control Expert Extra Large with Topology Manager and Safety
(see page 1/24)
b EcoStruxure Control Expert Extra Large Topology Manager Add-on
(see page 1/25)
b EcoStruxure Control Expert Large and Extra Large M580 Safety Add-on
(see page 1/26)
4
New floating licenses are available
In addition to the usual licenses that are linked to the computer where EcoStruxure
Control Expert is running (so-called node locked licenses), new floating licenses are
also available.
9
EcoStruxure Control Expert DVD package
Description Software size Reference Weight
kg/lb
EcoStruxure Control Small CEXPACKAGEV15 –
Expert DVD package Large
Extra Large
Extra Large Safety
Extra Large Topology Manager
10
1/20
References (continued) Software
EcoStruxure Control Expert
Small
10
1/21
References (continued) Software
EcoStruxure Control Expert
Large
2
Description License type Reference Weight
kg/lb
EcoStruxure Control Expert
EcoStruxure Control Expert Single (1 station) CEXSPUCZLSPMZZ –
Large software Paper license
Group (3 stations) CEXSPUCZLGPMZZ –
3
Large software E-license
6
distributed I/O, refer to the selection guide on page 1/2.
(2) Renewals for EcoStruxure Control Expert new versions are possible. Please contact our
Customer Care Center for more information.
10
1/22
References (continued) Software
EcoStruxure Control Expert
Extra Large
2
Description License type Reference Weight
kg/lb
EcoStruxure Control Expert
EcoStruxure Control Expert Single (1 station) CEXSPUCZXSPMZZ –
Extra Large software Paper
license Group (3 stations) CEXSPUCZXGPMZZ –
CEXSPUCZXTPTZZ
–
–
7
software licenses
Entity (100 stations) CEXSPUCZXEPTZZ
8
kg/lb
Paper license
Group Floating (3 stations) Team Floating (10 stations) CEXUPNCZXTPTZZ –
1/23
References (continued) Software
EcoStruxure Control Expert
Extra Large
Topology Manager and M580 Safety
2 EcoStruxure Control Expert EcoStruxure Control Expert Extra Large with Topology Manager and M580
Safety software licenses (1)
Description License type Reference Weight
kg/lb
EcoStruxure Control Single (1 station) CEXSPMCZXSPMZZ –
Expert Extra Large with Group (3 stations) CEXSPMCZXGPMZZ –
Topology Manager and
3 M580 Safety software
Paper license
Team (10 stations)
Entity (100 stations)
CEXSPMCZXTPMZZ
CEXSPMCZXEPMZZ
–
–
EcoStruxure Control Single (1 station) CEXSPMCZXSPAZZ –
Expert Extra Large with Corporate e-license CEXSPMFZXSPAZZ –
Topology Manager and (unlimited stations)
M580 Safety software
E-license
4 License upgrades for EcoStruxure Control Expert Extra Large with Topology
Manager and M580 Safety (1)
From To Reference Weight
kg/lb
Paper license
Single (1 station) Group (3 stations) CEXUMNCZXGPMZZ –
Group (3 stations) Team (10 stations) CEXUMNCZXTPMZZ –
5 Team (10 stations) Entity (100 stations) CEXUMNCZXEPMZZ –
E-license
Entity (100 stations) Corporate e-license CEXUMNFZXSPAZZ –
(unlimited stations)
EcoStruxure Control Expert Extra Large Floating with Topology Manager and
M580 Safety software licenses (1)
6 Description License type Reference Weight
kg/lb
EcoStruxure Control Group Floating (3 stations) CEXSPMCZXGPTZZ –
Expert Extra Large Floating Team Floating (10 stations) CEXSPMCZXTPTZZ –
with Topology Manager
and M580 Safety software Entity Floating (100 stations) CEXSPMCZXEPTZZ –
Paper license Education Entity Floating CEXSPMEZXEPTZZ –
7 EcoStruxure Control
(100 stations)
Group Floating (3 stations) CEXSPMCZXGPBZZ –
Expert Extra Large Floating Education Entity Floating CEXSPMEZXEPBZZ –
with Topology Manager (100 stations)
and M580 Safety software
E-license
License upgrades for EcoStruxure Control Expert Extra Large Floating with
8 Topology Manager and M580 Safety (1)
From To Reference Weight
kg/lb
Paper license
Group (3 stations) Team Floating (10 stations) CEXUMNCZXTPTZZ –
Team (10 stations) Entity Floating (100 stations) CEXUMNCZXEPTZZ –
1/24
References (continued) Software
EcoStruxure Control Expert
Extra Large
Topology Manager Add-on
Unity_548_RPSPH20001
2
For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum
EcoStruxure Control Expert
Topology Manager Add-on for EcoStruxure Control Expert Extra Large
software license (1)
Description License type Reference Weight
kg/lb
Topology Manager Add-on Single (1 station) CEXADMCZZSPMZZ –
for EcoStruxure Control
Expert Extra Large
software Paper license
Group (3 stations) CEXADMCZZGPMZZ – 3
Team (10 stations) CEXADMCZZTPMZZ –
Entity (100 stations) CEXADMCZZEPMZZ –
10
1/25
References (continued) Software
EcoStruxure Control Expert
Large/Extra Large
M580 Safety Add-on
To manage BMEP582040S or BMEH582040S Safety CPUs, the following licenses can be used:
b CEXSPUCZLpPMZZ (EcoStruxure Control Expert Large) with CEXADSCZZpPMZZ (M580
Safety Add-on for L or XL single)
To manage all Modicon M580 Safety CPU models, the following licenses can be used:
b CEXSPUCZXpPMZZ (EcoStruxure Control Expert Large) with CEXADSCZZpPMZZ (M580
3 Safety Add-On for L or XL single)
b CEXSPMCZXpPMZZ (EcoStruxure Control Expert Large with Topology Manager and M580
ddSafety)
M580 Safety Add-on for EcoStruxure Control Expert Large/Extra Large Safety
software license
Description License type Reference Weight
5
Entity (100 stations) CEXADSCZZEPMZZ –
M580 Safety Add-on for EcoStruxure Control Expert Extra Large Floating
software license
Description License type Reference Weight
kg/lb
M580 Safety Add-on for Group Floating (3 stations) CEXADSCZZGPTZZ –
EcoStruxure Control Expert
6 Extra Large (XL) Floating
software Paper license
Team Floating (10 stations) CEXADSCZZTPTZZ –
10
1/26
References (continued) Software
EcoStruxure Control Expert
Small/Large/Extra Large/Extra Large with Topology
Manager and Safety
4
I/O)
(1) The 490NTW00002 and 490NTW00002U RJ45 ConneXium cables (2 m/6.56 ft) can be used
to connect the PC to the SERVICE port of M580 CPUs or X80 drop. Please consult our
Website www.schneider-electric.com.
(2) Use the SR2CBL06 cable for connection on a USB port (3).
(3) Adapter equipped with a USB connector (PC side) and a 9-way SUB-D connector
(STBXCA4002 cable side); requires the STBXCA4002 cable (9-way SUB-D/HE 13) for
connection to the HE13 connector on the Modicon STB NIM.
5
10
1/27
1
10
2/0
Contents 2 - EcoStruxure Control Expert
Companion software
10
2/1
Presentation Software
EcoStruxure Control Expert
EcoStruxure Automation Device Maintenance -
Firmware upgrade tool
Presentation
EcoStruxure Automation Device Maintenance allows you to upgrade the firmware
1 on multiple devices simultaneously. The devices can be discovered automatically or
can be added manually if automatic device discovery is not supported or switched
off in the device.
The supported device discovery methods are:
b Modbus function code 43 (Read Device Identification)
b DPWS (Device Profile for Web Services)
5
in the tool. Selecting a certain package from the list will display the related
information of that package like category, product, release notes, and location.
b C
onfiguring settings: The Settings page allows you to configure discovery
mode, communication settings, package settings, logs, manage device
certificates, and select the desired language.
b E
rror and Warning window: The display details of the detected errors can be
displayed in a cumulative log window. The errors log provides the details to rectify
6 the detected error related to the selected device.
b Project: The Project feature allows you to create a new EcoStruxure Automation
Data package Device Maintenance project, and open and save existing ones.
In future versions, the project files will also be downloadable along with the firmware.
10
2/2
Presentation (continued), Software
references EcoStruxure Control Expert
EcoStruxure Automation Device Maintenance -
Firmware upgrade tool
PC-to-PAC Communication
EcoStruxure Automation Device Maintenance supports the following PC-to-PAC
communication:
b Modicon M340, M580, or Momentum Unity PACs or Modicon X80 I/O modules:
1
Communication via Ethernet and USB ports, transfer of project components and
firmware
Reference Type of module Ethernet port USB port
BMXP342000 M340 CPU with Modbus
BMXP342010/20103
BMXP342020
M340 CPU with CANopen
M340 CPU with integrated
2
BMXP342030/20302 Ethernet port
BMXNOE0100/0110 X80 Ethernet
Modbus/TCP module
BMXAMI/ART/AMO/AMM X80 Analog I/O module
BMXEHC0200/0800 X80 Counter module
BMXMSP0200 X80 Motion control
module
3
BMEP58 M580 CPUs
10XX/20XX/30XX/40XX
BMENOC03p1 M580 communication
module
171CBU78090 Momentum Unity CPU
171CBU98090/
with integrated port
Momentum Unity CPU
4
171CBU98091 with integrated port
Cybersecurity
The following ports are used by the software:
7
b Modbus (via port 502)
b HTTP (via port 80)/HTTPs (via ports 443 and 8080)
b FTP (via ports 20, 21)
b DPWS (via port 3702)
References
EcoStruxure Automation Device Maintenance is a freeware and can be downloaded
from our website www.schneider-electric.com, download section.
8
Description Type Reference Weight
Kg/lb
EcoStruxure Single license Software can be downloaded –
Automation Device (1 station) free of charge from our website
Maintenance www.schneider-electric.com
10
2/3
Presentation, Software
setup EcoStruxure Control Expert
EFB Toolkit software
Presentation
EFB Toolkit software helps to develop EFs and EFBs in “C” programming language.
1 As an option with EcoStruxure Control Expert, it can be used to extend the standard
EcoStruxure Control Expert function blocks in order to increase functionality. This
software comes with Microsoft Visual Studio, which can be used to debug the
function blocks developed in the EcoStruxure Control Expert PLC simulator. EFB
Toolkit also includes a service for creating and managing families of function blocks
and integrating them in EcoStruxure Control Expert.
2 EFB Toolkit
Setup
EFB Toolkit manages the whole process of developing EcoStruxure Control Expert
function blocks:
b User-friendly graphical user interface with automatic file organization
b Powerful tools for testing and debugging
b Management of compatibilities and software versions of created functions
3
b Generation of executable files for subsequent installation of functions on different
EcoStruxure Control Expert stations
4 function block families are installed on the EcoStruxure Control Expert stations for
the purpose of extending the standard EcoStruxure Control Expert libraries.
Integration in EcoStruxure Control Expert can be executed from EFB Toolkit or via
the tool for updating EcoStruxure Control Expert libraries, which allows these
families to be distributed without the use of any other software.
5 The EFB Toolkit software allows the user to create a function block as follows:
b Declaration of the function block interface in the same way as for the DFBs in
EcoStruxure Control Expert
EFB Toolkit: Managing function block families b Definition of all data types needed (elementary, structures, tables)
b Support of public and private variables
b Generation of all files and the block “C” coding frame (the user only adds
functionality to this frame)
6 b Granting access to numerous internal PAC services, such as the real-time clock,
PAC variables and data, system words and math functions, including high-
precision numerical processing in “double” format
b Structure of the function block family (compilation/link for all EcoStruxure Control
Expert automation platforms)
b Provision of a debugging environment: the function blocks created can easily be
debugged in Microsoft Visual Studio by downloading a EcoStruxure Control
8
Compatibility
EFB Toolkit is compatible with EcoStruxure Control Expert, Large and Extra Large.
EFs and EFBs can be developed for Modicon Premium, Quantum, M340, M580 and
Unity Momentum platforms.
10
2/4
References Software
EcoStruxure Control Expert
EFB Toolkit software
References
EFB Toolkit and its documentation are supplied in electronic format on DVD-ROM in
English and are available for download at www.schneider-electric.com. 1
EFB Toolkit package includes:
b EFB Toolkit DVD
b GNU Compiler CD
b Microsoft Visual Studio DVD
10
2/5
Presentation, Software
setup EcoStruxure Control Expert
Unity DIF software
Presentation
1
Unity DIF software helps to compare two EcoStruxure Control Expert application
files and represents differences in a graphical format similar to EcoStruxure Control
Expert graphics for consistency and better understanding. The differences are
displayed graphically and textually based on the type of section chosen. Unity DIF
improves productivity during the main life stages of a control system, mainly during
development and debugging of applications and commissioning, operation and
maintenance of the installation.
2 Unity DIF
Setup
Unity DIF compares two EcoStruxure Control Expert application files (XEF, ZEF,
STU and STA) and detects anything ADDED, DELETED and MODIFIED. The user
interface and graphical representation of differences are similar to EcoStruxure
Control Expert for consistency and ease of understanding the differences.
4
b PAC Configuration (Hardware and Network)
b Derived Data Types
b Derived FB Types
b Variables and FB Instance
b Motion
b Communication
b Programs
5
b Animation Table
b Operator Screen
Selection of elements to compare b DTM Catalog
b Project Settings
The result of the comparison can be printed or saved in .pdf and .txt file formats.
6
Windows® OS Compatibility
Unity DIF is compatible with Windows 7 (32-bit and 64-bit), Windows 10 (32-bit and
64-bit) and Windows Server 2008 R2 (64-bit).
Comparison (1)
The base and compare files have to be selected by the user, and the results of the
comparison will be displayed with respect to the base file as reference.
7 Before initiating comparison, the user can select his preference of required section
for comparison.
Displaying results
Upon comparison, the section summary will be loaded with the complete list of differences.
The user can navigate through the project browser window or using the F7 and F8 keys.
8 The differences will be highlighted in three different colors signifying Added, Deleted or
Modified types. Colors can be customized as per the user’s preference. The detailed report
can be generated through Print or can be Saved for later reference.
Unity DIF also supports command line processing and .txt report generation for interfacing
with Partner software.
Displaying results
9 (1) Comparison of STU and STA requires EcoStruxure Control Expert to be available.
10
2/6
References Software
EcoStruxure Control Expert
Unity DIF software
References
Unity DIF software is free and downloadable from our website:
www.schneider-electric.com. 1
Compatibility: From Unity Pro V2.1 to EcoStruxure Control Expert V15 or later.
Description Language Type Reference Weight
kg/lb
Unity DIF software English (software Single UNYDFFXZZSPA80 –
and electronic
documentation)
license
(1 station)
(1)
2
(1) Available on our website www.schneider-electric.com.
10
2/7
Presentation Software
EcoStruxure Control Expert
Unity Loader software
Presentation
Unity Loader is companion software to EcoStruxure Control Expert and is used to
1 perform maintenance operations on automation applications. Its easy setup and the
small size of its executable make it a vital tool for updating EcoStruxure Control
Expert projects without needing to use EcoStruxure Control Expert. It can also be
used for updating the embedded software on Modicon M340, M580, M580S or
Momentum Unity PACs or on Modicon X80 I/O modules. It performs the following
main functions:
b Transferring automation project components, such as the program and data, from
2 Unity Loader
the PC to the PAC or the PAC to the PC
b Transferring files and user Web pages stored in the memory card of Modicon
M340 PACs
b Transferring the firmware from the PC to Modicon M340, M580, M580S or
Momentum Unity PACs or to Modicon X80 I/O modules
4
program and data files created by Unity Loader are compatible with EcoStruxure
Control Expert. When it is connected to the PAC, Unity Loader displays the
information associated with the data read in the PAC. This information is displayed
on the PC for the selected files. The user decides which project elements will be
transferred by a single command after validation of the required transfers.
v Modicon M340 PACs and BMXRMSpp8MFP memory card only: the files and
Unity Loader: Project tab user Web pages can be transferred from the memory card to the PC and vice
5
versa.
v BMXNOE0110 with flash memory card only: Web pages stored in the flash
memory can be transferred from the module to the PC and vice versa.
b The “Firmware” tab can be used to update the firmware in the Modicon M340,
M580, M580S or Momentum Unity PACs or on Modicon X80 I/O modules. The
screen displays the detailed content of the firmware versions existing in the
module and on the PC. Firmware updating works in the same way as project
transfers.
6 b The “Options” tabs is used to configure the working environment, especially the
location of files on the PC and the selection of one of the six languages supported
(English, French, German, Italian, Spanish and Chinese) for the user interface
and online help.
b The “About…” tab displays information about the software.
7
Note: Regardless of which tab is selected, the connection status with the PAC is continuously
displayed, together with commands for connection/disconnection and changing the PAC
operating mode.
8
(controller or module) onto a flash memory card (BMXRMSpp8MFP only) plugged
into the PAC CPU.
This firmware download can then be used to update a remote Modicon M340 PAC.
10
2/8
Presentation (continued), Software
references EcoStruxure Control Expert
Unity Loader software
3
BMXNOE0100/0110 X80 module Ethernet
Modbus/TCP
BMXAMI/ART/AMO/AMM X80 module Analog I/O
BMXEHC0200/0800 X80 module Counter
BMXMSP0200 X80 module Motion
control
BMEP58 M580 CPUs
4
10XX/20XX/30XX/40XX
BMENOC03p1 M580 communication
module
171CBU78090 Momentum Unity CPU
with integrated port
171CBU98090/ Momentum Unity CPU
171CBU98091 with integrated port
References 6
Unity Loader can be downloaded free of charge from our website
www.schneider-electric.com, download section.
Compatibility
7
Unity Loader is independent of EcoStruxure Control Expert and compatible with
Modicon M340, M580 or Momentum Unity PACs, EcoStruxure Control Expert
Quantum PACs via Modbus and EcoStruxure Control Expert Premium PAC via
Unitelway. The program files and PAC data files are compatible between
EcoStruxure Control Expert and Unity Loader.
10
2/9
Presentation Software
EcoStruxure Control Expert
Specific libraries
Presentation
The CONT_CTL process control function block library supplied with EcoStruxure
1 Control Expert software can be supplemented with optional specialized libraries so
as to meet specific needs such as:
b Predictive control
b Fuzzy logic controller
b HVAC
b Mass flow calculation
2 EcoStruxure Control Expert specific Libraries GPL (General Purpose Library) for EcoStruxure Control Expert
General Purpose Library for EcoStruxure Control Expert provide the core
automation and device integration function blocks for your automation system. It
offers function blocks that are derived from GPL Library for Wonderware System
Platform or GPL Library for Vijeo Citect but only with Control Expert components
(Function Blocks, DFBs).
3 The GPL Library supports several Schneider Electric devices including TeSys T and
TeSys U starters-controllers, Modicon STB distributed inputs/outputs, power meters,
Altivar variable speed drives, Icla and Lexium integrated drives, SEPAM digital
protection relays, various fieldbus communications and other standard objects for
motors.
There are approximately 100 objects in the library. The GPL Library for EcoStruxure
Control Expert is available for free on Schneider Electric Exchange platform.
4
Additional libraries
Fuzzy Control Library
This library is used in particular in the water treatment field, for example for
controlling chlorine levels in fresh water pools or controlling water levels in high-level
reservoirs.
5
Flow Calculation Library
This library is used in the vertical Oil & Gas field, for measuring the gas flow in
compliance with the American Gas Association (AGA) standard. This version of the
library includes the AGA3, AGA7 and AGA8 function blocks.
6 TeSys Library
This library provides function blocks for TeSys T and TeSys U starter-controllers for
M340 and Premium platforms.
It includes function blocks and a help function for EcoStruxure Control Expert.
10
2/10
References Software
EcoStruxure Control Expert
Specific libraries
3
Heating Ventilation & Air UNYLHVZAUWB10 –
Conditioning Library
10
2/11
1
10
3/0
Contents 3 - EcoStruxure OPC UA
Server Expert
10
3/1
Presentation 3
Software 3
Presentation
EcoStruxure OPC UA Server Expert is a state of the art Schneider Electric
1 communications software platform. It seamlessly links our process automation edge
controllers and connected field devices to your information systems and the Industrial
Internet of Things (IIoT). The connections are established via the OPC Foundation’s
Open Platform Communications conforming to the Unified Architecture (OPC UA)
service-oriented architecture standard.
EcoStruxure OPC UA Server Expert
The OPC UA standard defines a modern, open communications architecture for
2 industrial communications that enhances cybersecurity and that is scalable from
resource constrained sensors through to cloud enterprise systems. OPC UA
extends the traditional industrial communications model with a full Service
Orientated Architecture (SOA) to publish and manage device metadata, and
context, thus helping to eliminate repetition, to simplify system configuration and to
reduce maintenance overhead.
3 Building on the field-proven device integration layer of OPC Factory Server (OFS),
EcoStruxure OPC UA Server Expert updates legacy ‘OPC Classic’ communications
provided by OFS with scalable OPC UA connectivity. It helps to maintain more
robust and secure integration with current and legacy Schneider Electric third-party
field devices.
With the V2.0 release, OPC UA Server Expert provides the following features:
4 b Compliance with OPC UA V1.03 ‘Standard Server’ profile
b IP-routable, bandwidth-efficient connectivity that helps to ensure communications
security
b Compatibility with modern communications infrastructure
b Certificate-based authentication and encryption helping to ensure more robust
end-to-end cybersecurity
b Metadata model support to define and communicate data structure, meaning, and
5 context
b Highly-available redundant architectures with auto change over
b Flexible ‘many-to-many’ device to OPC UA client connectivity
b Online real-time update capabilities
b Support for Modicon located and unlocated symbols
b Assistance in maintaining read-only access to Modicon M580 Safety ePAC symbols
7 Supported devices:
b Schneider Electric Process Automation Controllers
v M340 PAC
v M580 ePAC
b Generic Modbus/TCP devices via Ethernet connection
9 Redundant communications
OPC UA Server Expert incorporates native support for a redundant link with
Modicon M580 ePAC to increase system availability without impacting the
configuration or operational performance upstream OPC UA clients such as
SCADA. In the case of a communications interruption, OPC UA Server Expert
automatically changes over from the primary to the standby communication path
3/2
Architectures 0
Software 3
Use cases
The inclusion of OPC UA technology within OPC UA Server Expert enables a modern, open approach to industrial device data connectivity,
benefiting two different types of user requirements: 1
b Operational users who wish to directly monitor and control field equipment via supervisory control (SCADA) or human/machine interface
applications to manage the real-time operation of industrial processes.
These users can take advantage of the high performance and the support delivered by OPC UA Server Expert in providing a more robust and
more secure communications platform.
b Analysts or asset owners wishing to consolidate and analyze device and process data to drive performance insight and directed
improvement through advanced business intelligence and machine learning techniques.
These users can take advantage of the interoperable open standards, flexibility, metamodel capability and simplified SOA integration provided
2
by OPC UA Server Expert.
Supported architectures
EcoStruxure OPC UA Server Expert supports:
b Local or remote access via OPC UA
b Standalone or redundant server operation 3
Local access
The client application and the EcoStruxure OPC UA Server Expert are on the same PC.
Local client
application
EcoStruxure 4
OPC UA
program Server Expert
Modbus network 5
M580 M340
7
The client application and the EcoStruxure OPC UA Server Expert are on remote stations.
Communication between the client station and the EcoStruxure OPC UA Server Expert is conducted via the OPC UA protocol.
Ethernet network
Remote client
OPC UA Local client
application
EcoStruxure 8
application OPC UA
program program Server Expert
Modbus network
9
M580 M340
10
3/3
Setup Software 3
Setup
1 Ethernet Modbus/TCP
2 1 EcoStruxure 4
OPC UA
EcoStruxure
Server Expert
2
OPC UA
server
client
EcoStruxure
Database Symbols.xvm
Control Expert
(EcoStruxure
project station
Control Expert)
3 3 3
M580 M340
4 Modbus network
The EcoStruxure OPC UA Server Expert server 1 is at the center of the data exchanges. It makes variables exchanged between the EcoStruxure
OPC UA client 2 and the PAC 3 consistent in one of the ways described below using a symbol (or variables) database:
5
b The variables database is the PAC itself.
In this case, EcoStruxure Control Expert is not needed. This does not apply to the Momentum PAC. If an inconsistency is detected (following
online modification of the PAC program for example), the EcoStruxure OPC UA Server Expert server station resynchronizes itself automatically
as a background task, without breaking communication between the PAC and the OPC UA client.
b The accessible variables are eventually provided by an export file (XVM format) generated by ExoStruxure Control Expert.
In this case, EcoStruxure Control Expert is not required to be installed on the EcoStruxure OPC UA Server Expert server station.
10
3/4
Functions, Software 3
references 3
EcoStruxure OPC UA Server Expert
System requirements
EcoStruxure OPC UA Server Expert V2.0 is compliant with following platforms:
b Microsoft Windows® 7
b Microsoft Windows 10
1
b Microsoft Windows Server® 2012 R2 (1)
b Microsoft Windows Server 2016 (1)
EcoStruxure OPC UA Server Expert 32-bit and 64-bit platforms are supported, with a minimum of 4GB RAM required.
Multicore/multiprocessor architectures are highly recommended for optimal runtime
performance. 2
Unity Pro V13, EcoStruxure Control Expert V14 or higher is recommended.
References
The EcoStruxure OPC UA Server Expert V2.0 offer comprises:
b OPC UA server software
b OPC UA server simulator 3
b OPC UA server configuration software
b An example OPC UA client
b Setup documentation
EcoStruxure OPC UA Server Expert interfaces with variable export files generated
4
by EcoStruxure Control Expert software. It also provides a direct dynamic link to
EcoStruxure Control Expert applications.
10
3/5
1
10
4/0
Contents 4 - OPC data server software:
OFS (OPC Factory Server),
Time stamping system
10
4/1
Presentation 3
Software 3
Presentation
Based on the OLE for Process Control (OPC) standard, Schneider Electric's OPC
1 Factory Server (OFS) software allows “client” software applications, such as
supervisors/SCADA and customized interfaces, to access the data of Schneider
Electric automation system and electrical distribution devices connected to networks
OPC Factory Server or fieldbuses in real time.
It also allows communication with third-party devices supporting Modbus and
Modbus/TCP protocols.
2 OFS enables simpler, more open and transparent communication between your
software applications and your devices. These are just some of the advantages that
result in a complete interoperability solution that is central to your process.
There are two versions of the OFS V3.6 offer supporting the OPC DA protocol:
b OFS Small: Data server for 1,000 items (1).
4 b OFS Large: Data server with an unlimited number of items (1).
Openness
(1) “item”: variable, structure, table etc. in the Unity Pro application.
10
4/2
Architectures 0
Software 3
Supported architectures
The OFS server allows four access modes:
b A purely local mode
b Remote access from an OPC DA client
1
b Remote access from an OPC.NET client
Local access
The client application and the OFS server are on the same PC.
OFS station 2
Local client
applic. prog Symbol data
(Unity Pro,
Concept
OPC Factory Server: Home page or PL7)
3
Modbus network
Remote client
OFS station
Local client
6
application applic. prog Symbol data
program (Unity Pro ,
Concept
or PL7)
8
Premium M340
M580
Quantum
10
4/3
Architectures (continued) 0
Software 3
Intranet
The .NET Microsoft compatibility of the OFS server has been developed to allow an
OPC .NET client to access OFS server items on an Intranet network via the OPC
.NET API interface.
4 This interface provides interoperability between existing OPC applications and
applications developed in the standard .NET environment.
10
4/4
Setup 3
Software 3
Setup
Ethernet Modbus/TCP 1
1
OFS server
(V3.0) 4
Database Unity Pro
project
station
2
Symbols.xvm (Unity Pro)
Symbols.prj (Concept)
2 OPC client Symbols.scy (PL7)
3 Quantum
3
3 Premium
Ethernet Modbus/TCP
3 M580 3 M340 4
The OFS server 1 is at the center of the data exchanges. It makes variables
exchanged between the OPC client 2 and the PAC 3 consistent in one of three ways,
using a symbol (or variables) database:
b The variables database is either the Unity Pro project 4, or the Concept project.
5
In both these cases, Unity Pro or Concept needs to be installed on the OFS server
station.
b Or the variables database is an export file (SCY for PL7, XVM for Unity Pro). PL7
and Unity Pro are not required in either of these cases.
b Or the variables database is the PAC itself. In this case neither Unity Pro nor an 6
export file is needed. This does not apply to Momentum and TSX Micro PACs. If an
inconsistency is detected (following online modification of the PAC program for
example), OFS resynchronizes itself automatically as a background task, without
breaking communication between the PAC and the OPC client.
For this function the following minimum versions are required:
v OFS V3.35
v Unity Pro V6.0 7
v Modicon M340 V2.3, M580 V1.0, Premium V2.9 and Quantum V3.0 PACs
10
4/5
Functions 3
Software 3
Functions
Development of client applications
1 OFS software has 4 types of interface:
2
b OLE Custom interface (OPC DA)
Used primarily by suppliers of automated control system or industrial IT products,
this interface enables the development of applications in C++ in order to access the
OFS software OPC server. It is aimed at software development experts in particular,
so that they can integrate the client application into their standard products. It is the
interface with the highest performance, in terms of access time to data stored in the
OPC server. It requires extensive knowledge of C++ programming to set up.
10
4/6
References 3
Software 3
References
OFS V3.6 software for PC compatible stations (minimum configuration: Pentium
566 MHz processor, 128 MB of RAM) running Windows® 7 (32-bit or 64-bit) or
Windows 8 (32-bit or 64-bit).
1
OPC Factory Server The OFS V3.6 offer comprises:
b OPC server software
b OPC server simulator (for debugging the application when no PACs are present)
b OFS server configuration software
b An example of OPC client for setting up applications
b The setup documentation on DVD-ROM
2
b A reference document on “time stamping system” solutions
b A tool to help with sizing and configuring “time stamping system” solutions
7
items (1) 200 stations TLXCDLFOFS36 –
b Protocols supported:
OPC DA, OPC XML-DA
and OPC UA
OPC Factory Server V3.6 upgrades
Description Reference Weight
kg/lb
8
Update for OPC Factory TLXCDUPDSOFS –
Server V3.6 Small
(1) “item”: variable, structure, table etc. in the Unity Pro application.
10
4/7
Presentation Software 3
Presentation
The time stamping system is a complete solution providing a SCADA with a
1 sequence of events that are time-stamped at source, enabling the user to analyze
the source of any abnormal behavior in an automated system.
The SOE (sequence of events) is displayed in the alarm log or in the list of events for
a client such as a SCADA.
2 Each event in the SOE is a change of value (transition) of a discrete I/O detected by
a time stamping module.
Advantages
Using the time stamping system has the following advantages:
b No PAC programming
b Direct communication between the time stamping modules and the client. If the
3 time stamping modules are in an Ethernet I/O drop, the bandwidth of the PAC
communication is not used
b Consistency of the I/O values between the process (time stamping modules) and
the client
b Consistency is maintained irrespective of the operating mode
b Management of Hot Standby configurations on the PAC and/or SCADA
redundancy
4 Composition of a time stamping architecture
BMXCRA31210 and BMECRA31210 modules
Vijeo Citect alarm
OFS server terminal or This time stamping module can be at the source of any discrete I/O signal located in
Wonderware WSP
the drop with a resolution of 10 ms.
Quantum Ethernet To avoid losing any events, all events are stored and kept in a buffer located in the
5 M580
product until OFS takes them.
Synchronization of the CRA module uses the NTP protocol.
BMXERT1604T module
This module has 16 discrete inputs which carry out the time stamping on source
outputs with a resolution of 1 ms.
To avoid losing any events, the events are stored and kept in a buffer located in the
BMX-CRA1 BMX-ERT1
event event Time stamped variables can be provided by the BMXERT1604T, discrete modules
emory
m memory
Modicon X80
plugged into X80 drops, or even by the CPU since Unity V10.
drops
9
memory memory
The OFS-WSP driver has the same features as OPC V3.6 – Large apart from the
Modicon X80
drops following:
b It is licensed from a Wonderware environment only. It cannot be run outside a
Example of a time stamping architecture Wonderware environment
b It contains the server, the simulator, a sample client, configuration tool,
configuration manager, and a user manual
b It is OPC DA compatible only (No OPC UA – No OPC XML)
10
4/8
Performance Software 3
Performance
Performance Event source Value
3
Maximum number of source modules in an BM●CRA31210 1 per drop
Ethernet remote drop BMXERTpppp 9 per drop
Maximum number of event sources BMXERTpppp 500 sources per second (1)
controlled
(1) This maximum value is not an absolute value. It depends on the overall system dynamics
(total number of scanned items and number of events generated by the system).
10
4/9
1
10
5/0
Contents 5 - Product reference index
10
5/1
Index Product reference index
# CEXUPGCZXGPMZZ 1/23
110XCA28202 1/27 CEXUPGCZXGPTZZ 1/23
B CEXUPGCZXSPMZZ 1/23
BMXXCAUSBH018 1/27 CEXUPGCZXTPMZZ 1/23
BMXXCAUSBH045 1/27 CEXUPGCZXTPTZZ 1/23
C CEXUPNCZLGPMZZ 1/22
CEXADMCZZEPMZZ 1/25 CEXUPNCZLTPMZZ 1/22
CEXADMCZZEPTZZ 1/25 CEXUPNCZSGPMZZ 1/21
CEXADMCZZGPMZZ 1/25 CEXUPNCZSTPMZZ 1/21
CEXADMCZZGPTZZ 1/25 CEXUPNCZXEPTZZ 1/23
CEXADMCZZSPMZZ 1/25 CEXUPNCZXGPMZZ 1/23
CEXADMCZZTPMZZ 1/25 CEXUPNCZXTPMZZ 1/23
CEXADMCZZTPTZZ 1/25 CEXUPNCZXTPTZZ 1/23
CEXADMFZZSPAZZ 1/25 O
CEXADSCZZEPMZZ 1/26 OFSUASCZZEPMZZ 3/5
CEXADSCZZEPTZZ 1/26 OFSUASCZZSPMZZ 3/5
CEXADSCZZGPMZZ 1/26 OFSUASCZZTPMZZ 3/5
CEXADSCZZGPTZZ 1/26 S
CEXADSCZZSPMZZ 1/26 SR2CBL06 1/27
CEXADSCZZTPMZZ 1/26 STBXCA4002 1/27
CEXADSCZZTPTZZ 1/26 T
CEXPACKAGEV15 1/20 TLXCDLFOFS36 4/7
CEXSPMCZXEPMZZ 1/24 TLXCDLTOFS36 4/7
CEXSPMCZXEPTZZ 1/24 TLXCDLUOFS36 4/7
CEXSPMCZXGPBZZ 1/24 TLXCDSTOFS36 4/7
CEXSPMCZXGPMZZ 1/24 TLXCDSUOFS36 4/7
CEXSPMCZXGPTZZ 1/24 TLXCDUPDLOFS 4/7
CEXSPMCZXSPAZZ 1/24 TLXCDUPDSOFS 4/7
CEXSPMCZXSPMZZ 1/24 U
CEXSPMCZXTPMZZ 1/24 UNYDFFXZZSPA80 2/7
CEXSPMCZXTPTZZ 1/24 UNYLAGZAUWB20 2/11
CEXSPMEZXEPBZZ 1/24 UNYLFZZAUWB12 2/11
CEXSPMEZXEPTZZ 1/24 UNYLHVZAUWB10 2/11
CEXSPMFZXSPAZZ 1/24 UNYLPCZAUWB 2/11
CEXSPUCZLGPMZZ 1/22 UNYLTSZAUWB10 2/11
CEXSPUCZLSPAZZ 1/22 UNYSPUZFUCD80 2/5
CEXSPUCZLSPMZZ 1/22 UNYXCAUSB033 1/27
CEXSPUCZLTPMZZ 1/22
CEXSPUCZSGPMZZ 1/21
CEXSPUCZSSPAZZ 1/21
CEXSPUCZSSPMZZ 1/21
CEXSPUCZSTPMZZ 1/21
CEXSPUCZXEPMZZ 1/23
CEXSPUCZXEPTZZ 1/23
CEXSPUCZXGPMZZ 1/23
CEXSPUCZXGPTZZ 1/23
CEXSPUCZXSPAZZ 1/23
CEXSPUCZXSPMZZ 1/23
CEXSPUCZXTPMZZ 1/23
CEXSPUCZXTPTZZ 1/23
CEXUMFCZXEPTZZ 1/24
CEXUMFCZXGPTZZ 1/24
CEXUMFCZXTPTZZ 1/24
CEXUMNCZXEPMZZ 1/24
CEXUMNCZXEPTZZ 1/24
CEXUMNCZXGPMZZ 1/24
CEXUMNCZXTPMZZ 1/24
CEXUMNCZXTPTZZ 1/24
CEXUMNFZXSPAZZ 1/24
CEXUPGCZLGPMZZ 1/22
CEXUPGCZLSPMZZ 1/22
CEXUPGCZLTPMZZ 1/22
CEXUPGCZXEPTZZ 1/23
5/2
Learn more about our products at
www.schneider-electric.com
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the
products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability
of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk
analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric
nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
MKTED2140504EN
November 2020 - V8.0