Inspection Form - Fire Fighting and Fire Alarm

The preventive maintenance inspection report summarizes the inspection of a site's firefighting and fire alarm systems. It lists components checked including the fire alarm system, fire hose cabinets, fire hydrants, sprinklers network, and fire extinguishers. For each item, checking points like physical status, accessories, pressures, and expiry dates are noted along with any issues. The report is signed off by the client supervisor after the inspection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
247 views1 page

Inspection Form - Fire Fighting and Fire Alarm

The preventive maintenance inspection report summarizes the inspection of a site's firefighting and fire alarm systems. It lists components checked including the fire alarm system, fire hose cabinets, fire hydrants, sprinklers network, and fire extinguishers. For each item, checking points like physical status, accessories, pressures, and expiry dates are noted along with any issues. The report is signed off by the client supervisor after the inspection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PREVENTIVE MAINTENANCE INSPECTION REPORT

Fire Fighting / Fire Alarm


Site Name: Region/ City: Date:

Item Checking Points Notes


Fire Alarm System - Power AC …………………………………………………………....
Model/Brand: …………………………………………………………....
- Backup Batteries
…………………………………………………………....
…………………………………………….
- Wiring Connections …………………………………………………………....
Type: Addressable
…………………………………………………………....
Conventional - Loop Cards / Zones
…………………………………………………………....
Zones/Loops: - Faults / Troubles …………………………………………………………....
……………………………………………. …………………………………………………………....
- Devices:
SD QTY.……………………………….. …………………………………………………………....
Smoke Detector ( SD ) …………………………………………………………....
HD QTY..……………………………… …………………………………………………………....
Heat Detector ( HD )
BG/MCP QTY ……………………… …………………………………………………………....
Break Glass / Manual Call Point ( BG/MCP ) …………………………………………………………....
Bell / Siren QTY ………………….. …………………………………………………………....
Bell / Siren
Other …………………………………. …………………………………………………………....
- Repeater Panels if exist

Fire Hose Cabinets - Landing Valves …………………………………………………………....


…………………………………………………………....
- Drums & Hoses
…………………………………………………………....
QTY.……………………………………
- Physical Status of Bodies …………………………………………………………....
…………………………………………………………....
- Nozzles

Fire Hydrants - Physical Status of Bodies …………………………………………………………....


…………………………………………………………....
- Accessories
…………………………………………………………....
QTY………………………………………
- Seal Status …………………………………………………………....
…………………………………………………………....
- Valve ( Open / Close )

Sprinklers Network - End of Line Valves …………………………………………………………....


…………………………………………………………....
- Flow Valves
…………………………………………………………....
QTY………………………………………
- Physical Status of Sprinklers Heads …………………………………………………………....
…………………………………………………………....
- Zone Control Valves ( Open / Close )

Fire Extinguishers - Expiry Dates …………………………………………………………....


DP QTY. …..………….……………… …………………………………………………………....
- Pressure of Cylinders
…………………………………………………………....
CO2 QTY. ……………………………. - Physical Status of FE body …………………………………………………………....
Foam QTY. …………………………. …………………………………………………………....
- Accessibility

C.G Use the Following: CLIENT SUPERVISOR


NAME Not Applicable N/A NAME
DATE Not Working x DATE
SIGNATURE Checked / Working SIGNATURE