Part No. 060718-00, Rev.

A
July 2021

OmniSwitch 2x60
Hardware Users Guide

www.al-enterprise.com
This user guide documents OmniSwitch 2x60 hardware, including chassis and associated components. The
specifications described in this guide are subject to change without notice.

Service & Support Contact Information


North America: 800-995-2696
Latin America: 877-919-9526
EMEA: +800 00200100 (Toll Free) or +1(650)385-2193
Asia Pacific: +65 6240 8484
Web: businessportal.al-enterprise.com
Email: [email protected]
Contents

About This Guide ......................................................................................................... vii


Supported Platforms ......................................................................................................... vii
Related Documentation .................................................................................................... vii

Chapter 1 OmniSwitch 2x60 ....................................................................................................... 1-1


OmniSwitch 2x60 Availability Features .........................................................................1-4
Hot-Swapping ...........................................................................................................1-4
Hardware Monitoring ...............................................................................................1-4

Chapter 2 Getting Started ........................................................................................................... 2-1


Installing the Hardware ...................................................................................................2-1
Items Required .........................................................................................................2-1
Site Preparation ........................................................................................................2-1
Environmental Requirements ............................................................................2-1
Electrical Requirements .....................................................................................2-1
Electrical Surge Warning ..................................................................................2-1
Unpacking and Installing the Switch .......................................................................2-2
Items Included ...................................................................................................2-2
Weight Considerations ......................................................................................2-3
Airflow Considerations .....................................................................................2-4
Mounting the Switch .......................................................................................................2-4
Connections and Cabling ................................................................................................2-5
Network Cable Installation Warning .................................................................2-5
Serial Connection to the Console Port ...............................................................2-5
Serial Connection Default Settings ...................................................................2-5
Booting the Switch ..........................................................................................................2-6
Component LEDs ..............................................................................................2-6
Your First Login Session ................................................................................................2-7
Logging In to the Switch ..........................................................................................2-7
Unlocking Session Types .........................................................................................2-7
Changing the Login Password ..................................................................................2-8
Setting the System Time Zone .................................................................................2-8
Setting the Date and Time ........................................................................................2-8
Setting Optional Parameters .....................................................................................2-8
Specifying an Administrative Contact ...............................................................2-8
Specifying a System Name ................................................................................2-9
Specifying the Switch’s Location ......................................................................2-9
Viewing Your Changes ............................................................................................2-9
Saving Your Changes ...............................................................................................2-9

OmniSwitch 2x60 Hardware Users Guide July 2021 iii


Contents

Chapter 3 Chassis and Power Supplies .................................................................................... 3-1


OmniSwitch 2x60 Chassis Details ..................................................................................3-2
OS2260-10 ...............................................................................................................3-2
OS2260-10 Front Panel .....................................................................................3-2
OS2260-10 Rear Panel ......................................................................................3-2
OS2260-10 Chassis Specifications ....................................................................3-3
OS2260-P10 .............................................................................................................3-4
OS2260-P10 Front Panel ...................................................................................3-4
OS2260-P10 Rear Panel ....................................................................................3-4
OS2260-P10 Chassis Specifications ..................................................................3-5
OS2x60-24 ...............................................................................................................3-6
OS2x60-24 Front Panel .....................................................................................3-6
OS2x60-24 Rear Panel ......................................................................................3-6
OS2x60-24 Chassis Specifications ....................................................................3-7
OS2x60-P24 .............................................................................................................3-8
OS2x60-P24 Front Panel ...................................................................................3-8
OS2x60-P24 Rear Panel ....................................................................................3-8
OS2x60-P24 Chassis Specifications ..................................................................3-9
OS2x60-P24X ........................................................................................................3-10
OS2x60-P24X Front Panel ..............................................................................3-10
OS2x60-P24X Rear Panel ...............................................................................3-10
OS2x60-P24X Chassis Specifications .............................................................3-11
OS2x60-48 .............................................................................................................3-12
OS2x60-48 Front Panel ...................................................................................3-12
OS2x60-48 Rear Panel ....................................................................................3-12
OS2x60-48 Chassis Specifications ..................................................................3-13
OS2x60-P48 ...........................................................................................................3-14
OS2x60-P48 Front Panel .................................................................................3-14
OS2x60-P48 Rear Panel ..................................................................................3-14
OS2x60-P48 Chassis Specifications ................................................................3-15
OS2x60-P48X ........................................................................................................3-16
OS2x60-P48X Front Panel ..............................................................................3-16
OS2x60-P48X Rear Panel ...............................................................................3-16
OS2x60-P48X Chassis Specifications .............................................................3-17
Chassis Status LEDs ...............................................................................................3-18
Mounting the Switch .....................................................................................................3-19
General Mounting Recommendations ....................................................................3-19
Airflow Recommendations ....................................................................................3-20
Rack-Mounting .............................................................................................................3-21
Installing Rack Mount Flanges ..............................................................................3-21
Installing the Chassis In the Rack ..........................................................................3-23
Standalone (Non-Rack Mounted) Installations ......................................................3-24
Rack-Mounting 1/2 Width Switches .............................................................................3-25
Available 1/2 Width Rack-Mounting Kits .............................................................3-25
General Rack-Mounting Guidelines .......................................................................3-25
Installing Available Rack Mounting Kits .....................................................................3-26
Installing the OS2260-RM-L Rack Mount Kit ......................................................3-26
Grounding the Chassis ..................................................................................................3-27

iv OmniSwitch 2x60 Hardware Users Guide July 2021


Contents

Monitoring Chassis Components ..................................................................................3-28


Viewing Chassis Slot Information .........................................................................3-28
Monitoring Chassis Temperature ..................................................................................3-28
Temperature Errors ..........................................................................................3-29

Chapter 4 Managing Power over Ethernet (PoE) ................................................................. 4-1


In This Chapter ................................................................................................................4-2
Power over Ethernet Specifications ................................................................................4-3
Power over Ethernet Defaults .........................................................................................4-3
Power over Ethernet Budget ...........................................................................................4-4
Viewing Power Supply Status ..................................................................................4-4
Viewing PoE Status ..................................................................................................4-5
Understanding and Modifying the Default Settings .................................................4-5
PoE Class Detection .................................................................................................4-5
PoE Operational Status .............................................................................................4-6
Configuring the Total Power Available to a Port ..............................................4-7
Configuring the Total Power Available to a slot ...............................................4-7
Setting Port Priority Levels ...............................................................................4-8
Setting the Capacitor Detection Method ...........................................................4-8
Understanding Guard Band .............................................................................................4-8
Understanding Priority Disconnect ...............................................................................4-10
Setting Priority Disconnect Status ..........................................................................4-10
Disabling Priority Disconnect .........................................................................4-10
Enabling Priority Disconnect ..........................................................................4-10
Priority Disconnect is Enabled; Same Priority Level on All PD .....................4-11
Priority Disconnect is Enabled;
Incoming PD Port has Highest Priority Level .................................................4-11
Priority Disconnect is Enabled;
Incoming PD Port has Lowest Priority Level ..................................................4-11
Priority Disconnect is Disabled .......................................................................4-12
Monitoring Power over Ethernet via CLI .....................................................................4-13

Appendix A Regulatory Compliance and Safety Information .............................................. A-1


Declaration of Conformity: CE Mark ............................................................................ A-1
Waste Electrical and Electronic Equipment (WEEE) Statement ................................... A-1
China RoHS: Hazardous Substance Table ..................................................................... A-2
Taiwan RoHS: Hazardous Substance Table .................................................................. A-3
California Proposition 65 Warning ................................................................................ A-4
Standards Compliance .................................................................................................... A-5
FCC Class A, Part 15 .............................................................................................. A-7
Canada Class A Statement ...................................................................................... A-7
JATE ........................................................................................................................ A-7
CISPR22 Class A warning ...................................................................................... A-7
Korea Emissions Statement ..................................................................................... A-8
VCCI ....................................................................................................................... A-8

OmniSwitch 2x60 Hardware Users Guide July 2021 v


Contents

Class A Warning for Taiwan and Other Chinese Markets ...................................... A-8
Class 1M Laser Warning ......................................................................................... A-8
Network Cable Installation Warning ....................................................................... A-8
Translated Safety Warnings ........................................................................................... A-9
Blank Panels Warning ...................................................................................... A-9
Electrical Storm Warning ................................................................................. A-9
Installation Warning ......................................................................................... A-9
Invisible Laser Radiation Warning ................................................................. A-10
Operating Voltage Warning ........................................................................... A-10
Power Disconnection Warning ....................................................................... A-10
Proper Earthing Requirement Warning .......................................................... A-11
DC Power Supply Connection Warning ...................................................................... A-11
Read Important Safety Information Warning ................................................. A-12
Restricted Access Location Warning ............................................................. A-12
Wrist Strap Warning ....................................................................................... A-12
Instrucciones de seguridad en español ......................................................................... A-13
Advertencia sobre el levantamiento del chasis ............................................... A-13
Advertencia de las tapaderas en blanco .......................................................... A-13
Advertencia en caso de tormenta eléctrica ..................................................... A-13
Advertencia de instalación ............................................................................. A-13
Advertencia de radiación láser invisible ......................................................... A-13
Advertencia de la batería de litio .................................................................... A-13
Advertencia sobre la tensión de operación ..................................................... A-13
Advertencia sobre la desconexión de la fuente .............................................. A-13
Advertencia sobre una apropiada conexión a tierra ....................................... A-14
Leer “información importante de seguridad” ................................................. A-14
Advertencia de acceso restringido .................................................................. A-14
Advertencia de pulsera antiestática ................................................................ A-14
Clase de seguridad .......................................................................................... A-14
Advertencia de fuentes de poder .................................................................... A-14

vi OmniSwitch 2x60 Hardware Users Guide July 2021


About This Guide

This OmniSwitch 2x60 Hardware Users Guide describes OmniSwitch 2x60 switch components and basic
switch hardware procedures.

Supported Platforms
The information in this guide applies only to OmniSwitch 2260 and OmniSwitch 2360 switches.

Related Documentation
The following are the titles and descriptions of all the user manuals:
• OmniSwitch 2x60 Hardware Users Guide

Complete technical specifications and procedures for all OmniSwitch 2x60 chassis, power supplies,
fans, and Network Interface (NI) modules.
• OmniSwitch 2260/2360 AOS CLI Reference Guide

Complete reference to all CLI commands supported on the OmniSwitch. Includes syntax definitions,
default values, examples, usage guidelines and CLI-to-MIB variable mappings.
• OmniSwitch 2260/2360 WebView Guide

Includes procedures for readying an individual switch for integration into a network. Topics include the
software directory architecture, image rollback protections, authenticated switch access, managing
switch files, system configuration, using SNMP, and using web management software (WebView).
• Release Notes

Includes critical Open Problem Reports, feature exceptions, and other important information on the
features supported in the current release and any limitations to their support.

OmniSwitch 2x60 Hardware Users Guide July 2021 vii


viii OmniSwitch 2x60 Hardware Users Guide July 2021
1 OmniSwitch 2x60

Refer to the information below for OmniSwitch 2x60 models and components.

Model Number Description


OS2260-10 Fixed-configuration chassis in a 1U form factor with:
• 8 x RJ45 non-PoE ports
• 4 x SFP (1G) ports
• Internal power supply
• Fanless
See “OS2260-10” on page 3-2
OS2260-P10 Fixed-configuration chassis in a 1U form factor with:
• 8 x RJ45 PoE (802.3at) ports
• 4 x SFP (1G) ports
• Internal power supply
• Fanless
See “OS2260-P10” on page 3-4.
OS2260-24 Fixed-configuration chassis in a 1U form factor with:
• 24 x RJ45 non-PoE ports
• 4 x SFP (1G) ports
• Internal power supply
• Fanless
See “OS2x60-24” on page 3-6.
OS2260-P24 Fixed-configuration chassis in a 1U form factor with:
• 24 x RJ45 PoE (802.3at) ports
• 4 x SFP (1G) ports
• Internal power supply
• 1 Fan
See “OS2x60-P24” on page 3-8
OS2260-P24X Fixed-configuration chassis in a 1U form factor with:
(China model) • 24 x RJ45 PoE (802.3at) ports
• 2 x SFP (1G) ports
• 2 x SFP+ (1G/10G) ports
• Internal power supply
• 1 Fan
See “OS2x60-P24X” on page 3-10
OS2260-48 Fixed-configuration chassis in a 1U form factor with:
• 48 x RJ45 non-PoE ports
• 6 x SFP (1G) ports
• Internal power supply
• 1 Fan
See “OS2x60-48” on page 3-12

OmniSwitch 2x60 Hardware Users Guide July 2021 page 1-1


OmniSwitch 2x60

Model Number Description


OS2260-P48 Fixed-configuration chassis in a 1U form factor with:
• 48 x RJ45 PoE (802.3at) ports
• 6 x SFP (1G) ports
• Internal power supply
• 1 Fan
See “OS2x60-P48” on page 3-14
OS2260-P48X Fixed-configuration chassis in a 1U form factor with:
(China model) • 48 x RJ45 PoE ports
• 4 x SFP (1G) ports
• 2 x SFP+ (1G/10G) ports
• Internal power supply
• 2 Fans
See “OS2x60-P48X” on page 3-16
OS2360-24 Fixed-configuration chassis in a 1U form factor with:
• 24 x RJ45 non-PoE ports
• 2 x SFP (1G) ports
• 2 x SFP (1G) Uplink or SFP+ (10G) VFL ports
• Internal power supply
• Fanless
See “OS2x60-24” on page 3-6.
OS2360-P24 Fixed-configuration chassis in a 1U form factor with:
• 24 x RJ45 PoE (802.3at) ports
• 2 x SFP (1G) ports
• 2 x SFP (1G) Uplink or SFP+ (10G) VFL ports
• Internal power supply
• 1 Fan
See “OS2x60-P24” on page 3-8
OS2360-P24X Fixed-configuration chassis in a 1U form factor with:
• 24 x RJ45 PoE (802.3at) ports
• 2 x SFP+ (1G/10G) ports
• 2 x SFP (1G) Uplink or SFP+ (10G) VFL ports
• Internal power supply
• 1 Fan
See “OS2x60-P24X” on page 3-10
OS2360-48 Fixed-configuration chassis in a 1U form factor with:
• 48 x RJ45 non-PoE ports
• 4 x SFP (1G) ports
• 2 x SFP (1G) Uplink or SFP+ (10G) VFL ports
• Internal power supply
• 1 Fan
See “OS2x60-48” on page 3-12
OS2360-P48 Fixed-configuration chassis in a 1U form factor with:
• 48 x RJ45 PoE (802.3at) ports
• 4 x SFP (1G) ports
• 2 x SFP (1G) Uplink or SFP+ (10G) VFL ports
• Internal power supply
• 1 Fan
See “OS2x60-P48” on page 3-14

page 1-2 OmniSwitch 2x60 Hardware Users Guide July 2021


OmniSwitch 2x60

Model Number Description


OS2360-P48X Fixed-configuration chassis in a 1U form factor with:
• 48 x RJ45 PoE ports
• 2 x SFP (1G) ports
• 2 x SFP+ (1G/10G) ports
• 2 x SFP (1G) Uplink or SFP+ (10G) VFL ports
• Internal power supply
• 2 Fans
See “OS2x60-P48X” on page 3-16

OmniSwitch 2x60 Hardware Users Guide July 2021 page 1-3


OmniSwitch 2x60 Availability Features OmniSwitch 2x60

OmniSwitch 2x60 Availability Features


The switch provides a broad variety of availability features. Availability features are hardware and
software-based safeguards that help prevent the loss of data flow in the unlikely event of a subsystem
failure. In addition, some availability features allow users to maintain or replace hardware components
without powering off the switch or interrupting switch operations. Combined, these features provide added
resiliency and help ensure that the switch is consistently available for day-to-day network operations.
Hardware-related availability features include:
• Hot-Swapping
• Hardware Monitoring

Hot-Swapping
Hot-swapping refers to the action of adding, removing, or replacing certain hardware components without
powering off your switch and disrupting other components in the chassis. This feature greatly facilitates
hardware upgrades and maintenance and also allows you to easily replace components in the unlikely
event of hardware failure.

Hardware Monitoring
Automatic Monitoring
Automatic monitoring refers to the switch’s built-in sensors that automatically monitor operations. If an
error is detected (e.g., over-threshold temperature), the switch immediately sends a trap to the user. The
trap is displayed on the console in the form of a text error message.

LEDs
LEDs, which provide visual status information, are provided on the front and rear panels. LEDs are used
to indicate conditions, such as hardware and software status, link integrity, data flow, etc. For detailed
LED descriptions, refer to the corresponding hardware component section in the next chapter.

User-Driven Monitoring
User-driven hardware monitoring refers to CLI commands that are entered by the user in order to access
the current status of hardware components. The user enters “show” commands that output information to
the console. The show commands for all the features are described in detail in the CLI Reference Guide.

page 1-4 OmniSwitch 2x60 Hardware Users Guide July 2021


2 Getting Started

Installing the Hardware


Items Required
• Grounding wrist strap
• Phillips screwdriver
• Flat-blade screwdriver

Site Preparation

Environmental Requirements
The switches have the following environmental and airflow requirements:
• The installation site must maintain a supported temperature and humidity range as given in the
specifications table for the chassis. See “OmniSwitch 2x60 Chassis Details” on page 3-2.
• Be sure to allow adequate room for proper air ventilation at the front, back, and sides of the switch.
Refer to “Airflow Considerations” on page 2-4 for minimum clearance requirements. No clearance is
necessary at the top or bottom of the chassis.

Electrical Requirements

Note. Switches must be installed by a professional installer. It is the responsibility of the installer to ensure
that proper grounding is available and that the installation meets applicable local and national electrical
codes.

The switches have the following general electrical requirements:


• Each switch requires one grounded electrical outlet for each power supply installed in the chassis.
• For switches using AC power connections, each supplied AC power cord is 2 meters (approx. 6.5 feet).
Do not use extension cords.

Electrical Surge Warning


In order to help protect equipment against electrical surges please take note of the following
recommendations and guidelines:
1 Earth grounding of all devices is fundamental to ensure long term reliability.

• All electrical equipment must be installed by a qualified, licensed electrician.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 2-1


Installing the Hardware Getting Started

• Every power supply that is connected to building power should be earth grounded.

• Earth grounding for the power cable, should be verified to be 0.01 ohm or less.

• Each switch should be grounded to same earth ground as the power supply.

• Each powered device, such as an AP or camera, should be connected to earth ground.

• Each surge suppression device should be connected to earth ground.

2 Shielded cables (STP) offer some minimal level of additional protection over unshielded Ethernet
cables (UTP) but the use of a surge protector is still recommended.
• It is suggested to use STP Cat5e or better for 1Gbps Ethernet switches for any outdoor application or
applications where Ethernet cables come in close proximity to alternating current conductors.
• Always install cables according to manufacturer requirements.

3 For any connections where integrity of the cabling within a building ground is questionable (i.e outdoor
connections), copper Ethernet ports must be connected with an appropriate surge protection device, inline,
between the PSE and PD per the manufacturer’s recommendations for connection and grounding.
4 Caution should be taken for any cable connected to any outdoor device, not only on the device ground-
ing, but to ensure that any outdoor device cables that could carry surge currents, do not pass those surge
currents to upstream Ethernet switches.
5 Caution - Category 5e, Category 6, and Category 6a cables can store large amounts of static electricity
due to the dielectric properties of their construction materials in addition, this build up of electricity could
lead to a Cable Discharge Event (CDE). A CDE can occur due to the differential in charges on the cable
and the equipment it’s being connected to. It is recommended that installers momentarily ground all
copper Ethernet cables (especially in new cable runs) to a suitable and safe earth ground before connect-
ing them to the port.

Note. Failure to follow the above recommendations could result in voiding the warranty of the affected
product.

Unpacking and Installing the Switch


To protect your switch components from damage, read all unpacking recommendations and instructions
carefully before beginning.
Unpack your chassis as close as possible to the location where it will be installed.

Items Included
Your OmniSwitch may include the following items:
• OmniSwitch chassis with power supplies, per order
• Transceivers, per order
• Blank cover panel
• Rack mount brackets

page 2-2 OmniSwitch 2x60 Hardware Users Guide July 2021


Getting Started Installing the Hardware

• Country-specific power cord(s)


• Rubber table-mounting feet
• Attachment screws
• Assorted instructional cards, anti-static bags and additional packaging

Weight Considerations
Weights vary depending on model type. Please refer to the chassis specifications table.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 2-3


Mounting the Switch Getting Started

Airflow Considerations
To ensure proper airflow, be sure that your switch is placed in a clean, well-ventilated area free of dust and
debris and provide minimum recommended clearance at the front, back and sides of the switch.
Never obstruct chassis air vents.

} Rear. 6 inches minimum


at rear of chassis.

Sides. 2 inches minimum


at left and right sides.

} Front. 6 inches minimum


at front of chassis.

Chassis Top View

Note. Clearance is not required at the top and bottom of the chassis.

Mounting the Switch


For information on mounting the switches, refer to the Chapter 3, “Chassis and Power Supplies.”

page 2-4 OmniSwitch 2x60 Hardware Users Guide July 2021


Getting Started Connections and Cabling

Connections and Cabling


Once your switch is properly installed, you should connect all network and management cables required for
your network applications. Connections may include:
• Console connector
• Cables to NIs or transceivers

Network Cable Installation Warning


Never install exposed network cables outdoors. Install network cables per manufacturer requirements.

Serial Connection to the Console Port


The console port provides a serial connection to the switch is required when logging into the switch for the
first time. By default, this connector provides a DCE console connection.

Serial Connection Default Settings


baud rate 115200
parity none
data bits (word size) 8
stop bits 1

OmniSwitch 2x60 Hardware Users Guide July 2021 page 2-5


Booting the Switch Getting Started

Booting the Switch


Now that you have installed the switch components and connected network and management cables, you can
boot the switch. To boot the switch, plug all power supply cords into easily-accessible, properly grounded
power outlets. (Do not use extension cords.) The switch will power on and boot automatically.

Component LEDs
During the boot process, component LEDs will flash and change color, indicating different stages of the boot
For complete information on LED states, refer to “Chassis Status LEDs” on page 3-18.
Once the switch has completely booted and you have accessed your computer’s terminal emulation software
via the console port, you are ready to log in to the switch’s Command Line Interface (CLI) and configure basic
information. Continue to “Your First Login Session” on page 2-7.

page 2-6 OmniSwitch 2x60 Hardware Users Guide July 2021


Getting Started Your First Login Session

Your First Login Session


In order to complete the setup process for the switch, you must complete the following steps during your first
login session:
• Log in to the switch using the console or WebView using the default IP address of 192.168.1.3 (See
the WebView guide for additional information)
• Unlock session types
• Change the login password
• Set the date and time
• Set optional system information
• Save your changes

Logging In to the Switch


When you first log in to the switch, you will be prompted for a login name and password. Use the switch’s
default settings:
• Login: admin
• Password: switch
The default welcome banner, which includes information such as the current software version and system date,
is displayed followed by the CLI command prompt:
Welcome to the Alcatel-Lucent OmniSwitch AOS 5.1R01, June 15, 2021.

Copyright (c) 1994-2014 Alcatel-Lucent. All Rights Reserved.

OmniSwitch(tm) is a trademark of Alcatel-Lucent, registered in the United States


Patent and Trademark Office.

Unlocking Session Types


Security is a key feature on an OmniSwitch switch. As described on page 2-7, when you access the switch for
the first time you can use a direct console port connection or the default IP address using WebView. All other
session types (Telnet, FTP, and SNMP) are locked out until they are manually unlocked by the user.
The CLI command used to unlock session types is aaa authentication.

Unlocking All Session Types


To unlock all session types, enter the following command syntax at the CLI prompt:
-> aaa authentication default local

Unlocking Specified Session Types


You can also unlock session types on a one-by-one basis. For example, to unlock Telnet sessions only, enter
the following command:
-> aaa authentication telnet local

To unlock WebView (HTTP) sessions only, enter the following command:

OmniSwitch 2x60 Hardware Users Guide July 2021 page 2-7


Your First Login Session Getting Started

-> aaa authentication http local

You cannot specify more than one session type in a single command line. However, you can still unlock
multiple session types by using the aaa authentication command in succession. For example:
-> aaa authentication http local
-> aaa authentication telnet local
-> aaa authentication ftp local

Refer to the CLI Reference Guide for complete aaa authentication command syntax options.

Changing the Login Password


Change the login password for admin user sessions by following the steps below:

1 Be sure that you have logged into the switch as user type admin (see “Logging In to the Switch” on
page 2-7).
2 Enter the keyword password and press Enter.

3 Enter your new password at the prompt.

Note. Be sure to remember or securely record all new passwords; overriding configured passwords on an
OmniSwitch is restricted.

4 You will be prompted to re-enter the password. Enter the password a second time.

New password settings are automatically saved in real time to the local user database; the user is not required
to enter an additional command in order to save the password information. Also note that new password
information is retained following a reboot. All subsequent login sessions, including those through the console
port, will require the new password to access the switch.

Setting the System Time Zone


The switch’s default time zone is UTC. If you require a time zone that is specific to your region, or if you need
to enable Daylight Savings Time (DST) on the switch, you can configure these settings via the system
timezone and system daylight-savings-time commands.

Setting the Date and Time


Set the current time for the switch by entering system time, followed by the current time in hh:mm:ss.
To set the current date for the switch, enter system date, followed by the current date in mm/dd/yyyy.

Setting Optional Parameters

Specifying an Administrative Contact


An administrative contact is the person or department in charge of the switch. If a contact is specified, users
can easily find the appropriate network administrator if they have questions or comments about the switch.

page 2-8 OmniSwitch 2x60 Hardware Users Guide July 2021


Getting Started Your First Login Session

To specify an administrative contact, use the system contact command.

Specifying a System Name


The system name is a simple, user-defined text description for the switch. To specify a system name, use the
system name command.

Specifying the Switch’s Location


It is recommended that you use a physical labeling system for locating and identifying your switch(es).
Examples include placing a sticker or placard with a unique identifier (e.g., the switch’s default IP address) on
each chassis.
However, if no labeling system has been implemented or if you need to determine a switch’s location from a
remote site, entering a system location can be very useful.
To specify a system location, use the system location command.

Viewing Your Changes


To view your current changes, enter show system at the CLI prompt.

Saving Your Changes


Once you have configured this basic switch information, save your changes by entering write memory at the
CLI command prompt.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 2-9


Your First Login Session Getting Started

page 2-10 OmniSwitch 2x60 Hardware Users Guide July 2021


3 Chassis and Power Supplies

This chapter includes detailed information on the chassis types. Topics include:
• Chassis details and technical specifications:

OS2260-10, page 3-2.


OS2260-P10, page 3-4.
OS2x60-24, page 3-6.
OS2x60-P24, page 3-8.
OS2x60-P24X, page 3-10.
OS2x60-48, page 3-12
OS2x60-P48, page 3-14.
OS2x60-P48X, page 3-16.
• Switch mounting information, page 3-19.

• Temperature management, page 3-28.

• Monitoring the chassis components via the Command Line Interface (CLI), page 3-28

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-1


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OmniSwitch 2x60 Chassis Details


OS2260-10
OS2260-10 Front Panel

5.25V Max, 0.5A Max


Console / USB

C B
D
1 2 3 4 5 6 7 8 9 10 11 12 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-8) 10/100/1000 Base-T ports
D (9-12) SFP ports (1G)

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2260-10 Rear Panel

A B

Item Description
A Chassis Grounding Lug
B Power Supply Connector (30W Internal AC Power Supply)

page 3-2 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2260-10 Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 21.7 cm (8.5 in)
Chassis Depth 28.1 cm (11.1 in)
Chassis Weight 1.8 kg (3.9 lb)
Power Consumption (idle) 13 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-3


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2260-P10
OS2260-P10 Front Panel

5.25V Max, 0.5A Max


Console / USB

C B
1 2 3 4 5 6 7 8 9 10
D 11 12 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-8) 10/100/1000 Base-T PoE(802.3at) ports
D (9-12) SFP ports (1G)

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2260-P10 Rear Panel

B
A

Item Description
A Chassis Grounding Lug
B Power Supply Connector (120W Internal AC Power Supply)

page 3-4 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2260-P10 Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 21.7 cm (8.5 in)
Chassis Depth 28.1 cm (11.1 in)
Chassis Weight 1.9 kg (4.2 lb)
Power Consumption (idle) 14 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-5


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2x60-24
OS2x60-24 Front Panel

5.25V Max, 0.5A Max


Console / USB

C B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D 27 28 OK VC PWR

A
5.25V Max, 0.5A Max
Console / USB

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D 27 28 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-24) 10/100/1000 Base-T ports
D (2260) (25-28) SFP (1G) ports
D (2360) (25-26) SFP (1G) ports
(27-28) SFP (1G) Uplink or SFP+ (10G) VFL ports

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2x60-24 Rear Panel

A B

Item Description
A Chassis Grounding Lug
B Power Supply Connector (65W Internal AC Power Supply)

page 3-6 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2x60-24 Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 44 cm (17.3 in)
Chassis Depth 30 cm (11.8 in)
Chassis Weight 3.39 kg (7.47 lb)
Power Consumption (idle) 25 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-7


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2x60-P24
OS2x60-P24 Front Panel

5.25V Max, 0.5A Max


Console / USB

C B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D 27 28 OK VC PWR

5.25V Max, 0.5A Max


Console / USB

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D 27 28 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-24) 10/100/1000 Base-T PoE (802.3at) ports
D (2260) (25-28) SFP (1G) ports
D (2360) (25-26) SFP (1G) ports
(27-28) SFP (1G) Uplink or SFP+ (10G) VFL ports

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2x60-P24 Rear Panel

B
A

Item Description
A Chassis Grounding Lug
B Power Supply Connector (260W Internal AC Power Supply)

page 3-8 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2x60-P24 Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 44 cm (17.3 in)
Chassis Depth 30 cm (11.8 in)
Chassis Weight 3.62 kg (7.98 lb)
Power Consumption (idle) 32 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-9


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2x60-P24X
OS2x60-P24X Front Panel

5.25V Max, 0.5A Max


Console / USB

C B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D 27 28 OK VC PWR

5.25V Max, 0.5A Max


Console / USB

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D 27 28 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-24) 10/100/1000 Base-T PoE (802.3at) ports
D (2260) (25-26) SFP (1G) ports
(27-28) SFP+ (1G/10G) ports
D (2360) (25-26) SFP+ (1G/10G) ports
(27-28) SFP (1G) Uplink or SFP+ (10G) VFL ports

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2x60-P24X Rear Panel

B
A

Item Description
A Chassis Grounding Lug
B Power Supply Connector (550W Internal AC Power Supply)

page 3-10 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2x60-P24X Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 44 cm (17.3 in)
Chassis Depth 30 cm (11.8 in)
Chassis Weight 3.8 kg (8.38 lb)
Power Consumption (idle) 32 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-11


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2x60-48
OS2x60-48 Front Panel

5.25V Max, 0.5A Max


Console / USB

C D B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 OK VC PWR

5.25V Max, 0.5A Max


Console / USB

D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-48) 10/100/1000 Base-T ports
D (2260) (49-54) SFP (1G) ports
D (2360) (49-52) SFP (1G) ports
(53-54) SFP (1G) Uplink or SFP+ (10G) VFL ports

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2x60-48 Rear Panel

B
A

Item Description
A Power Supply Connector (65W Internal AC Power Supply)
B Chassis Grounding Lug

page 3-12 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2x60-48 Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 44 cm (17.3 in)
Chassis Depth 30 cm (11.8 in)
Chassis Weight 3.8 kg (8.3 lb)
Power Consumption (idle) 52 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-13


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2x60-P48
OS2x60-P48 Front Panel

5.25V Max, 0.5A Max


Console / USB

C D B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 OK VC PWR

5.25V Max, 0.5A Max


Console / USB

D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-48) 10/100/1000 Base-T PoE (802.3at) ports
D (2260) (49-54) SFP (1G) ports
D (2360) (49-52) SFP (1G) ports
(53-54) SFP (1G) Uplink or SFP+ (10G) VFL ports

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2x60-P48 Rear Panel

B
A

Item Description
A Power Supply Connector (550W Internal AC Power Supply)
B Chassis Grounding Lug

page 3-14 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2x60-P48 Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 44 cm (17.3 in)
Chassis Depth 30 cm (11.8 in)
Chassis Weight 4.2 kg (9.3 lb)
Power Consumption (idle) 53 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-15


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

OS2x60-P48X
OS2x60-P48X Front Panel

5.25V Max, 0.5A Max


Console / USB

C D B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 OK VC PWR

5.25V Max, 0.5A Max


Console / USB

D
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 OK VC PWR

Item Description
A Status LEDs
B Console and USB port
C (1-48) 10/100/1000 Base-T PoE (802.3at) ports
D (2260) (49-52) SFP (1G) ports
(53-54) SFP+ (1G/10G) ports
D (2360) (49-50) SFP (1G) ports
(51-52) SFP+ (1G/10G) ports
(53-54) SFP (1G) Uplink or SFP+ (10G) VFL ports

CLASS 1 M LASER CAUTION. CAUTION - CLASS 1 M LASER RADIATION WHEN OPEN.


DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS

OS2x60-P48X Rear Panel

A B

Item Description
A Chassis Grounding Lug
B Power Supply Connector (950W Internal AC Power Supply)

page 3-16 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies OmniSwitch 2x60 Chassis Details

OS2x60-P48X Chassis Specifications


Chassis Height 4.4 cm (1.7 in)
Chassis Width 44 cm (17.3 in)
Chassis Depth 30 cm (11.8 in)
Chassis Weight 4.5 kg (9.9 lb)
Power Consumption (idle) 53 W
Operating Temperature (Tmra) 0°C to 45°C (32°F to 113°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity 5% to 95% non-condensing
Storage Humidity 5% to 85% non-condensing

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of
the internal switch temperature (threshold or danger). Ambient temperature refers to the approximate room
temperature. The ambient temperature will typically be lower than the chassis temperature.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-17


OmniSwitch 2x60 Chassis Details Chassis and Power Supplies

Chassis Status LEDs


The chassis provides a series of status LEDs located on the front panel. These LEDs offer basic status
information for hardware operation and port link and activity status.

LED State Description


OK Solid Green System Diagnostics and AOS bootup OK.

Blinking Green System Diagnostics and AOS in progress


(i.e., performing diagnostics or booting).

Solid Amber System Diagnostics and AOS/fan/temp fail


VC Blinking Green Master (number of blinks identifies ID).

Blinking Amber Slave (number of blinks identifies ID).

Off Unknown/error state.


PWR Solid Green Main power supply normal.

Solid Amber Main power supply fault (12V).

Blinking Amber Main power supply fault (54V/PoE).

Off Main power supply not present.


RJ45 Port LEDs Solid Green Valid port link (non-PoE).

Blinking Green Valid port link with activity (non-PoE).

Solid Amber Valid port link (PoE).

Blinking Amber Valid port link with activity (PoE).


SFP Port LEDs Solid / Blinking Green Uplink port / with activity.

Solid / Blinking Amber VFL port / with activity.

page 3-18 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies Mounting the Switch

Mounting the Switch


General Mounting Recommendations
Elevated Operating Ambient Temperature. If installed in a closed or multi-rack assembly, the
operating ambient temperature of the rack environment may be greater than the room’s ambient
temperature. Therefore, consideration should be given to the maximum rated ambient temperature (Tmra)
listed in the “OmniSwitch 2x60 Chassis Details” section.
Reduced Air Flow. Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised. Refer to “Airflow Recommendations”
on page 3-20 for more information.
Mechanical Loading. Mounting of the equipment in the rack should be such that a hazardous condition is
not achieved due to uneven loading.
Circuit Overloading. Consideration should be give to the connection of the equipment to the supply
circuit and the effect that overloading of circuits could have on overcurrent protection and supply wiring.
Reliable Earthing. Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch (e.g., use of
power strips).

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-19


Mounting the Switch Chassis and Power Supplies

Airflow Recommendations
To ensure proper airflow, be sure that your switch is placed in a clean, well-ventilated area free of dust and
debris and provide minimum recommended clearance at the front, back and sides of the switch, as shown
below. Restricted airflow can cause your switch to overheat, which can lead to switch failure. Refer to the
following important guidelines regarding airflow:
Follow the guidelines below regarding the minimum clearance requirements when mounting
the chassis.

} Rear. 6 inches minimum


at rear of chassis.

Sides. 2 inches minimum


at left and right sides.

} Front. 6 inches minimum


at front of chassis.

Chassis Top View

Note. Clearance is not required at the top and bottom of the chassis.

page 3-20 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies Rack-Mounting

Rack-Mounting
Refer to the following important guidelines before installing the chassis in a rack:
• Two people are required to rack mount the switch: One person to lift the chassis into position and one
person to secure the chassis to the rack using the rack mount screws.
• The chassis has rack-mount flanges that support standard 19-inch rack mount installations.
• Alcatel-Lucent Enterprise does not provide rack-mount screws. Use the screws supplied by the
rack vendor.
• To prevent a rack from becoming top heavy, it is recommended that you install the switch at the
bottom of the rack whenever possible.

Note. If you are installing the switch in a relay rack, be sure to install and secure the rack per rack manu-
facturer’s specifications.

Installing Rack Mount Flanges


1 To install rack mount flanges, start by making sure the spring clip is in the out (disengaged) position.

2 Insert the tab into the chassis slot as shown.

Clip in “Out”
(disengaged)
position
Tab

Slot

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-21


Rack-Mounting Chassis and Power Supplies

3 Press the flange and spring clip until the flange clicks into place and the clip is in the in
(engaged) position.

Clip in “In”
(engaged)
position

“CLICK”

4 Secure the flange to the chassis using the attachment screw(s).

5 Repeat steps 1 through 4 for the flange on the opposite side of the chassis.

page 3-22 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies Rack-Mounting

Installing the Chassis In the Rack


1 Mark the holes on the rack where the chassis is to be installed.

2 One person should lift and position the chassis until the rack-mount flanges are flush with the
rack post.
3 Align the holes in the flanges with the rack holes marked in step 1.

4 Once the holes are aligned, the second person should insert a screw through the bottom hole on each
flange. Tighten both screws until they are secure.

5 Install the remaining screws in the top hole of each flange. Be sure that all screws are
securely tightened.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-23


Rack-Mounting Chassis and Power Supplies

Standalone (Non-Rack Mounted) Installations


The chassis can also be placed unmounted on a stable, flat surface as a standalone unit. Be sure that the
surface can accommodate the full, populated weight of all switches being installed. (Approximate chassis
weights are provided in the technical specifications tables in the “OmniSwitch 2x60 Chassis Details”
section.)
Be sure that adequate clearance has been provided for chassis airflow and that you have placed the chassis
within reach of all required AC outlets. For recommended airflow allowances, refer to page 3-20.
To prepare the chassis for tabletop installations, follow the steps below:
1 Insert the four (4) rubber feet (provided separately in the switch packaging) into the holes in the bottom
panel of the chassis.
2 Place the switch on the tabletop “right side up.”

Note. Never attempt to operate a switch while it is placed on its top or side.

3 Connect network and management cables as needed.

page 3-24 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies Rack-Mounting 1/2 Width Switches

Rack-Mounting 1/2 Width Switches


The following kits are available for rack mounting 1/2 width switches.

Note. Some factory-installed screws may need to be removed prior to mounting, depending on the kit
being used.

Available 1/2 Width Rack-Mounting Kits


Kit Description
OS2260-RM-19-L Simple L-bracket for mounting one 1/2 unit in a 19" rack. See page 3-26 for
installation instructions.
OS2260-WALL-MNT Contains universal mounting brackets for wall mounting.

Note. For information on rack mounting full width 24- and 48-port switches, refer to
“Mounting the Switch” on page 3-19.

General Rack-Mounting Guidelines


If you will be rack-mounting your switch(es), refer to the important guidelines below before installing.
• It is recommended that two people install the switch assembly on the rack—one person to hold the
chassis and position it on the rack, and a second person to secure the chassis to the rack using
attachment screws. (Please note that Alcatel-Lucent does not provide rack-mount screws. Use the
screws supplied by the rack vendor.)
• To prevent a rack from becoming top heavy, it is recommended that you install heavier equipment at
the bottom of the rack, whenever possible.
• Review page 4-1 for recommended chassis clearances before installing.

• If you are installing the switch on a relay rack, be sure to install and secure the rack per the rack
manufacturer’s specifications.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-25


Installing Available Rack Mounting Kits Chassis and Power Supplies

Installing Available Rack Mounting Kits

Note. Some factory-installed screws may need to be removed prior to mounting, depending on the kit
being used.

Installing the OS2260-RM-L Rack Mount Kit


A single chassis can also be mounted into a standard 19-inch rack using L-brackets, as shown in the figure
below.
1 Attach rack mount brackets to both sides of the front of the chassis.The long and short bracket can be
mounted on either side of the chassis.

Attach Rack Mount Brackets

2 Align the holes in the flanges with the rack holes and insert rack mount screws (not provided) through
the bottom hole of each flange and then the top of each flange. Tighten both screws until they are secure

Follow the recommended clearance requirements for the


model type being mounted.

Rack-mounting Single Chassis

page 3-26 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies Grounding the Chassis

Grounding the Chassis


The switch has a grounding lug located on the rear of the chassis. This lug uses 10-32 screws and is
surrounded by a small paint-free area, which provides metal-to-metal contact for a ground connection.
Use this connector to supplement the ground provided by the AC power cord. To do so, install a Panduit
Grounding Lug (type LCD8-10A-L) using 8AWG copper conductors to the paint-free area.
Refer to the rear chassis views on page 3-2 for location details.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-27


Monitoring Chassis Components Chassis and Power Supplies

Monitoring Chassis Components


Viewing Chassis Slot Information
To view basic slot information, enter the show module command at the CLI prompt:

-> show module

To view more detailed information, use the show module long command:

-> show module long

Monitoring Chassis Temperature


The operating temperature of your switch is a critical factor in its overall operability. In order to avoid a
temperature-related system failure, your switch must always run at a temperature within the specified
operating temperature range.
To avoid chassis over-temperature conditions, follow the important chassis airflow recommendations on
page 3-20.

To check the switch’s current temperature status, use the show temperature command. For example:

-> show temperature


Chassis/Device | Current | Range | Danger | Thresh | Status
---------------+---------+---------+--------+--------+-----------------
1/CMMA 54 15-93 93 96 UNDER THRESHOLD
1/Slot1 54 15-93 93 101 UNDER THRESHOLD
2/CMMA 39 15-85 85 88 UNDER THRESHOLD
2/Slot1 39 15-85 85 101 UNDER THRESHOLD

For more information about this command, see the “Chassis Management and Monitoring Commands”
chapter in the CLI Reference Guide.

page 3-28 OmniSwitch 2x60 Hardware Users Guide July 2021


Chassis and Power Supplies Monitoring Chassis Temperature

Temperature Errors
The switch monitors the chassis temperature at all times via an onboard sensor. If an over-temperature
condition occurs, there are two different levels of error severity:
• Warning threshold has been exceeded

• Danger threshold has been exceeded

Warning Threshold
If the temperature exceeds the switch’s Warning threshold, the switch sends out a trap. Traps are also
printed to the console in the form of text error messages.
When the Warning threshold has been exceeded, switch operations remain active. However, it is
recommended that immediate steps be taken to address the over-temperature condition.
Addressing Warning threshold temperature conditions may include:
• Checking for a chassis airflow obstruction

• Checking the ambient room temperature

Temperature Danger Threshold


If the chassis temperature rises above the Danger threshold, the switch will power off until the temperature
conditions have been addressed and the switch is manually booted. The Danger threshold is factory-set
and cannot be configured by the user.
Addressing danger threshold temperature conditions may include:
• Checking for a chassis airflow obstruction

• Checking the ambient room temperature

OmniSwitch 2x60 Hardware Users Guide July 2021 page 3-29


Monitoring Chassis Temperature Chassis and Power Supplies

page 3-30 OmniSwitch 2x60 Hardware Users Guide July 2021


4 Managing Power over Ethernet
(PoE)

Power over Ethernet (PoE) provides inline power directly from the switch’s Ethernet ports. Powered
Devices (PDs) such as IP phones, wireless LAN stations, Ethernet hubs, and other access points can be
plugged directly into the Ethernet. From these RJ-45 the devices receive both electrical power and
data flow.
As the feature reduces devices’ dependence on conventional power sources, PoE eliminates many restric-
tions that traditional electrical considerations have imposed on networks.
In a PoE configuration, Power Source Equipment (PSE) detects the presence of a PD and provides an elec-
trical current that is conducted along the data cable. The PD operates using the power received via the
Ethernet data cable; no connection to an additional power source (e.g., an AC wall socket) is required.

Note on Terminology. There are several general terms used to describe the feature, PoE. The terms Power
over Ethernet (PoE), Power over LAN (PoL), Power on LAN (PoL), and Inline Power are synonymous
terms used to describe the powering of attached devices via Ethernet. For consistency, this chapter and the
CLI Reference Guide refer to the feature as Power over Ethernet (PoE).
Additional terms, such as Powered Device (PD) and Power Source Equipment (PSE) are not synonymous
with PoE, but are directly related to the feature:
• PD refers to any attached device that uses a PoE data cable as its only source of power. Examples
include access points, IP telephones, Ethernet hubs, wireless LAN stations, etc.
• PSE refers to power sourcing equipment, which provides power to a single link section. PSE main
functions include searching the PD, optionally classifying the PD, supplying power to the link section
only if the PD is detected, monitoring the power on the link section, and scaling power back to detect
level when power is no longer requested or required.

As the switches fully support 10/100/1000 Ethernet connectivity, you may also attach non-PD equipment,
such as computer workstations, printers, servers, etc. to the PoE ports.

Important. It’s recommended that PoE-enabled switches with attached IP telephones should have opera-
tional power supply redundancy at all times for 911 emergency requirements. In addition, both the switch
and the power supply should be plugged into an Uninterruptible Power Source (UPS).

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-1


In This Chapter Managing Power over Ethernet (PoE)

In This Chapter
This chapter provides specifications and descriptions of hardware and software used to provide PoE for
attached devices.
The chapter also provides information on configuring PoE settings on the switch through the Command
Line Interface (CLI). CLI commands are used in the configuration examples; for more details about the
syntax of commands, see the CLI Reference Guide. Topics and configuration procedures described in this
chapter include:
• Power over Ethernet Specifications on page 4-3

• Viewing Power Status on page 4-4

• Configuring Power over Ethernet Parameters on page 4-4

• Understanding Priority Disconnect on page 4-10

• Monitoring Power over Ethernet via the CLI on page 4-13

page 4-2 OmniSwitch 2x60 Hardware Users Guide July 2021


Managing Power over Ethernet (PoE) Power over Ethernet Specifications

Power over Ethernet Specifications


The table below lists general specifications for Alcatel-Lucent’s Power over Ethernet support. For more
detailed power supply and Power Source Equipment (PSE) specifications, refer to Chapter 3, “Chassis and
Power Supplies.” .

IEEE Standards supported IEEE 802.3; 802.af; 802.3at


PoE Class Detection Supported
Range of inline power per port 802.3at ports - 3000-30000 milliwatts
Maximum PoE power per chassis See “Power over Ethernet Budget”.

Power over Ethernet Defaults


The following table lists the defaults for PoE configuration:

Parameter
Command(s) Default Value/Comments
Description
PoE operational status lanpower slot service Disabled
Power available to a lanpower power 802.3at ports - 30000 milliwatts
port
Power available to an lanpower slot maxpower See “Power over Ethernet Budget”.
entire slot
Power priority level for lanpower priority low
a port
Capacitor detection lanpower capacitor-detec- Disabled
method tion
Priority disconnect sta- lanpower slot priority-dis- Enabled
tus connect

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-3


Power over Ethernet Budget Managing Power over Ethernet (PoE)

Power over Ethernet Budget


The following table lists the Power over Ethernet wattages available based on the number and types of power
supplies installed.

OmniSwitch PoE Budget


OS2260-P10 75W
OS2260-P24/OS2360-P24 195W
OS2260-P24X/OS2360-P24X 370W
OS2260-P48/OS2360-P48 370W
OS2260-P48X/OS2360-P48X 740W

Viewing Power Supply Status


To view the type and status for installed power supplies, use the show powersupply command:

-> show powersupply


Total PS
Chassis/PS Power Type Status Location
-----------+---------+--------+--------+-----------
1/1 550 AC UP Internal
Total 550

page 4-4 OmniSwitch 2x60 Hardware Users Guide July 2021


Managing Power over Ethernet (PoE) Power over Ethernet Budget

Viewing PoE Status


To view current PoE status and settings, use the show lanpower slot command:

-> show lanpower slot 1/1


Port Maximum(mW) Actual Used(mW) Status Priority On/Off Class Type
----+-----------+---------------+-----------+---------+--------+-------+----------
1 60000 0 Powered Off Low OFF .
2 60000 0 Powered Off Low OFF .
3 60000 0 Powered Off Low OFF .
4 60000 0 Powered Off Low OFF .
5 30000 0 Powered Off Low OFF .
6 30000 0 Powered Off Low OFF .
7 30000 0 Powered Off Low OFF .
8 30000 0 Powered Off Low OFF .
9 30000 0 Powered Off Low OFF .
10 30000 0 Powered Off Low OFF .
...
45 30000 0 Powered Off Low OFF .
46 30000 0 Powered Off Low OFF .
47 30000 0 Powered Off Low OFF .
48 30000 0 Powered Off Low OFF .

ChassisId 1 Slot 1 Max Watts 370


370 Watts Total Power Budget Used
370 Watts Total Power Budget Available
1 Power Supplies Available
BPS power: Not Available

Understanding and Modifying the Default Settings


The sections below provide information on each of the key components within the Power over Ethernet
software. They include information on PoE-related CLI commands. For detailed information on PoE-
related commands, refer to the CLI Reference Guide.

PoE Class Detection


Powered devices can be classified into different classes as shown in the table below. Class detection
allows for automatic maximum power adjustment based on the power class detected. This will prevent the
switch from delivering more than the maximum power allowed based on a device’s class.
During class detection, the switch will allocate the maximum amount of power allowed based on the class
detected. Once powered, if the device uses less than the maximum, the remaining power will be made
available for other devices.

Power at Port
Standard Class Type Pairs
(Watts)
IEEE 802.3af 0 1 2 15.4
1 1 2 4.0
2 1 2 7.0
3 1 2 15.4
802.3at 4 2 2 30

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-5


Power over Ethernet Budget Managing Power over Ethernet (PoE)

Although class-detection is disabled by default, the switch still provides power to incoming PDs (if avail-
able in the power budget). However, to strictly enforce class detection it must be enabled using the
lanpower slot class-detection command.
Enabling class detection will reset all PoE ports on the chassis.

PoE Operational Status


Enabling PoE
By default, Power over Ethernet is administratively enabled in the switch’s system software. However, in
order to physically activate PoE, you must issue the lanpower slot service command on a slot-by-slot
basis before any connected PDs will receive inline power.
To activate power to PoE-capable in a switch, enter the corresponding slot number only. For example:
-> lanpower slot 2/1 service start

If power to a particular port has been administratively disconnected, you can reactivate power to the port
using the lanpower port admin-state command. For example:
-> lanpower port 2/1/1-24 admin-state enable

Note. You cannot use the lanpower port admin-state command to initially activate PoE on a port. This
syntax is intended only to reactivate power to those that have been disconnected via the lanpower slot
service command. To initially activate PoE, you must use the lanpower slot service command as
described above.

Disabling PoE
To disable PoE on a particular port, use the lanpower port admin-state command. For example:
-> lanpower port 1/1/12 admin-state disable

To disable PoE for all PoE-capable ports in a slot, use the lanpower slot service command. For example:
-> lanpower slot 1/1 service stop

Fast PoE
Fast PoE can be used to provide PoE power within a few seconds after powering on the chassis. Prior to
this feature PoE power was not provided until the chassis had completed boot-up. With Fast PoE the
default state of the PoE subsystem is set to enabled in the FPGA image and the PoE configuration is stored
in the controller EEPROM. This allows the chassis to immediately provide PoE power to any connected
devices immediately after being powered on without waiting for the chassis to complete the boot-up
process.
• Factory default switches that don't have any PoE configuration must have an initial PoE configuration
completed.
• The PoE configuration cannot be modified until the switch is up and the PoE software module is
completely initialized.
• LLDP-based PoE devices will not function as expected until the switch has completed the boot-up
process and the switch is in a state to respond to LLDP requests.

page 4-6 OmniSwitch 2x60 Hardware Users Guide July 2021


Managing Power over Ethernet (PoE) Power over Ethernet Budget

Fast PoE can be enabled using the syntax below:


-> lanpower slot 1/1 fpoe enable

Perpetual PoE
Perpetual PoE allows the switch to provide uninterrupted power to connected power devices (PD) even
when the switch is rebooting or reloading, such as on a soft reset.
• The power to the PD devices will be interrupted if the PoE controller (MCU) firmware itself is being
upgraded.
Perpetual PoE can be enabled using the syntax below:
-> lanpower slot 1/1 ppoe enable

Configuring the Total Power Available to a Port


By default, each port is authorized by the system software to use up to a maximum amount of milliwatts to
power any attached device.
You can either increase or decrease this value based on the allowed ranges.
Increasing the total power available to an individual port may provide a more demanding Powered Device
(PD) with additional power required for operation. Decreasing the total power available to a port helps to
preserve inline power and assists in the overall management of the switch’s power budget.
To increase or decrease the total power available to an individual port, use the lanpower power
command. Since you are setting the power allowance for an individual port, you must specify chassis/slot/
port values in the command line. For example, the syntax
-> lanpower port 1/1/24 power 3000

reduces the power allowance on port 24 to 3000 milliwatts. This new value is now the maximum amount
of power the port can use to power any attached device (until the value is modified by the user).

Configuring the Total Power Available to a slot


Like the maximum port power allowance, the system software also provides a maximum slot-wide power
allowance. By default, each slot is authorized by the system software to use a number of watts to power all
devices connected to its ports depending on which power supply is used.
As with the maximum port power allowance, the user can either increase or decrease this value based on
the allowed ranges.

Important. Decreasing the slot-wide power could cause lower priority ports to lose power if the new
value is less than the total PoE power currently being consumed.

To increase or decrease the total power available to a slot, use the lanpower slot maxpower command.
Since you are setting the power allowance for an individual slot, you must specify a chassis/slot value in
the command line. For example, the syntax
-> lanpower slot 3/1 maxpower 400

reduces the power allowance of chassis 3, slot 1 to 400 watts. This value is now the maximum amount of
power the slot can use to power all attached devices (until the value is modified by the user).

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-7


Understanding Guard Band Managing Power over Ethernet (PoE)

Note. Changing the maximum power available to a slot or port does not reserve or immediately allocate
that power. These settings are only used for configuring a maximum amount of power that may be used,
any unused power is still available and remains a part of the overall PoE budget.

Setting Port Priority Levels


As not all Powered Devices (PDs) connected to the switch have the same priority within a network setting,
the OmniSwitch allows the administrator to specify priority levels on a port-by-port basis. Priority levels
include low, high, and critical. The default priority level for a port is low.
• Low. This default value is used for port(s) that have low-priority devices attached. In the event of a
power management issue, inline power to low-priority is interrupted first (i.e., before critical and high-
priority).
• High. This value is used for port(s) that have important, but not mission-critical, devices attached. If
other ports in the chassis have been configured as critical, inline power to high-priority is given second
priority.
• Critical. This value is used for port(s) that have mission-critical devices attached, and therefore require
top (i.e., critical) priority. In the event of a power management issue, inline power to critical is main-
tained as long as possible.
To change the priority level for a particular port, use the lanpower priority command. Since the switch
allows you to set priority levels on a port-by-port basis, be sure to specify chassis/slot/port information in
the command line. For example, the syntax
-> lanpower port 1/1/6 priority critical

changes the priority value of port 6 to the highest priority level of critical. Now that the default value has
been reconfigured, this port should be reserved for those PDs that are mission critical for network opera-
tions.

Setting the Capacitor Detection Method


By default, the capacitor detection method is disabled. To enable it, use the lanpower capacitor-detec-
tion. For example:
-> lanpower slot 3/1 capacitor-detection enable

Note. The capacitive detection method should only be enabled to support legacy IP phones. This feature
is not compatible with IEEE specifications. Please contact your Alcatel-Lucent sales engineer or Customer
Support representative to find out which Alcatel-Lucent IP phones models need capacitive
detection enabled.

Understanding Guard Band


Guard Band functionality is implemented when the switch has to provide power to a newly connected PD. This
functionality is more relevant on switches that have a lower amount of total PoE power available for the switch
but a higher default maximum PoE power available to some ports.

page 4-8 OmniSwitch 2x60 Hardware Users Guide July 2021


Managing Power over Ethernet (PoE) Understanding Guard Band

• If the amount of power remaining is less than the port's configured maximum PoE power value or the PD's
class maximum power then the switch will not power up the PD.
• This applies even if the newly connected PD actually requires less than the maximum power available for
the port.

For example, assume the following:


• There is 50W of PoE power remaining on the switch.
• A newly connected PD only requires 4W of power.
• The port's maximum PoE power value is 75W.

In this example the newly connected PD will not be powered on since the port's maximum PoE power value is
greater than the PoE power remaining on the switch.

To allow the PD to be powered, the port's maximum PoE value can be configured to be less than the power
remaining by issuing the following command to set the port's maximum PoE power to 10W:
-> lanpower power 1/1/1 power 10000

Using the previous example:


• There is 50W of PoE power remaining on the switch.
• A newly connected PD only requires 4W of power.
• The port's maximum PoE power value is now 10W.

The newly connected PD will be powered on since the port's maximum PoE power value is now less than the
PoE power remaining on the switch. The examples assume the new PD has the same or lower priority as the
existing PDs, otherwise priority disconnect will override.

The Guard Band functionality does not apply to PDs that are already powered up. However, priority disconnect
will apply if there's not enough power to power all PDs in the case of the power budget being reduced, such as
the removal of a power supply.

Please refer to the “Understanding Priority Disconnect” on page 4-10 for additional details.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-9


Understanding Priority Disconnect Managing Power over Ethernet (PoE)

Understanding Priority Disconnect


The priority disconnect function differs from the port priority function described on page 4-8 in that it
applies only to the addition of powered devices (PDs) in tight power budget conditions. Priority discon-
nect is used by the system software in determining whether an incoming PD will be granted or denied
power when there are too few watts remaining in the PoE power budget for an additional device. For
example, if there are only 2 watts available in the current PoE power budget and a user plugs a 3.5W
powered device into a PoE port, the system software must determine whether the device will be powered
on. Based on priority disconnect rules, in some cases one or more existing devices may be powered down
in order to accommodate the incoming device. In other cases, the incoming device will be denied power.
Priority disconnect rules involve the port priority status of an incoming device (i.e., low, high, and criti-
cal), as well as the port’s physical port number (i.e., 1–24). Understanding priority disconnect rules is
especially helpful in avoiding power budget deficits and the unintentional shutdown of mission-critical
devices when PDs are being added in tight power budget conditions. For detailed information on how
priority disconnect uses port priority and port number criteria for determining the power status of incom-
ing PDs, refer to the illustrated examples on pages 4-11 through 4-12.

Reminder. Priority disconnect applies only when there is inadequate power remaining in the power
budget for an incoming device.

For information on setting the priority disconnect status, refer to the section below. For information on
setting the port priority status (a separate function from priority disconnect), refer to “Setting Port Priority
Levels” on page 4-8.

Setting Priority Disconnect Status


By default, priority disconnect is enabled in the switch’s system software. For information on changing the
priority disconnect status, refer to the information below.

Disabling Priority Disconnect


When priority disconnect is disabled and there is inadequate power in the budget for an additional device,
power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and critical)
or physical port number (i.e., 1–24).
To disable priority disconnect, use the lanpower slot priority-disconnect command. For example:
-> lanpower slot 2/1 priority-disconnect disable

Enabling Priority Disconnect


To enable priority disconnect, use the lanpower slot priority-disconnect command. For example:
-> lanpower slot 2/1 priority-disconnect enable

page 4-10 OmniSwitch 2x60 Hardware Users Guide July 2021


Managing Power over Ethernet (PoE) Understanding Priority Disconnect

Priority Disconnect is Enabled; Same Priority Level on All PD

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to
power an incoming device.

When a PD is being connected to a port with the same priority level as all other in the slot, the physical
port number is used to determine whether the incoming PD will be granted or denied power. Due to the
support of different PoE standards and PoE hardware on each platform the internal port priority is differ-
ent for each platform. The following should be used to determine PoE priority:

Port Number 1 (Highest) -> 48(Lowest)

PoE Physical Port Priority

Priority Disconnect is Enabled; Incoming PD Port has Highest Priority Level

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to
power an incoming device.

When a PD is being connected to a port with a higher priority level than all other in the slot, the incoming
PD will automatically be granted power over the other devices, regardless of its physical port number.
In order to avoid a power budget deficit, another port in the slot is disconnected. In determining which
port to power off, the system software first selects the port with the lowest configured priority level. For
example, if a critical priority device is being added to a slot in which five existing devices are attached to
high priority and one device is attached to a low priority port, the low priority port is automatically
disconnected, regardless of its physical port number.
If all existing devices are attached to with the same lower priority level, the system software disconnects
the port with both the lowest priority level and the highest priority physical port number. For example, if a
critical priority device is being added to a slot in which six existing devices are attached to high priority,
the high priority port with the lowest physical port priority number is automatically disconnected.

Priority Disconnect is Enabled; Incoming PD Port has Lowest Priority Level

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to
power an incoming device.

When a PD is being connected to a port with a lower priority level than all other in the slot, the incoming
PD will be denied power, regardless of its physical port number. Devices connected to other higher-prior-
ity will continue operating without interruption.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-11


Understanding Priority Disconnect Managing Power over Ethernet (PoE)

Priority Disconnect is Disabled

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to
power an incoming device.

When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its port
priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24).

page 4-12 OmniSwitch 2x60 Hardware Users Guide July 2021


Managing Power over Ethernet (PoE) Monitoring Power over Ethernet via CLI

Monitoring Power over Ethernet via CLI


To monitor current PoE statistics and settings, use the show lanpower slot command. The command
output displays a list of all current PoE-capable, along with the following information for each port:
• Maximum power available to the port, in milliwatts

• Actual power used by the port

• Current port status

• Power priority status

• Power on/off status

Aggregate slot and chassis management information is also displayed. This information includes:
• Maximum watts available to the corresponding slot

• Amount of power budget remaining for PoE modules

• Total amount of power remaining for additional switch functions

When entering the show lanpower command, you must include a valid slot number in the command line
syntax. For example:

-> show lanpower 1


Port Maximum(mW) Actual Used(mW) Status Priority On/Off Class
----+-----------+---------------+-----------+---------+--------+-------
1 30000 12500 Powered On Low ON 0
2 30000 1800 Powered On Low ON 1
3 30000 3500 Powered On Low ON 2
4 30000 9800 Powered On Low ON 3
5 30000 25000 Powered On Low ON 4
6 30000 0 Undefined Low ON -
7 30000 0 Undefined Low ON -
8 30000 0 Undefined Low ON -
9 30000 0 Undefined Low ON -

(output truncated)

21 30000 0 Undefined Low ON -


22 30000 0 Undefined Low ON -
23 30000 0 Undefined Low ON -
24 30000 0 Undefined Low ON -

Slot 3 Max Watts 150


1 Power Supplies Available

Note. For detailed information on show lanpower command output, refer to the CLI Reference Guide.

OmniSwitch 2x60 Hardware Users Guide July 2021 page 4-13


Monitoring Power over Ethernet via CLI Managing Power over Ethernet (PoE)

page 4-14 OmniSwitch 2x60 Hardware Users Guide July 2021


A Regulatory Compliance and
Safety Information

This appendix provides information on regulatory agency compliance and safety for the OmniSwitch.

Declaration of Conformity: CE Mark


This equipment is in compliance with the essential requirements and other provisions of
Directive 2014/30/EU (EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/EEC (Telecom
Terminal Equipment, if applicable), 2014/53/EU (R&TTE, if applicable).
Français: Cet équipement est conforme aux exigences essentielles et aux autres provisions de la Directive
2014/30/EU (EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/EEC (équipements
terminaux de télécommunications, le cas échéant), 2014/53/EU (R&TTE, le cas échéant).
Deutsch: Diese Ausrüstung erfüllt die wesentlichen Anforderungen und sonstigen Bestimmungen der
Richtlinien 2014/30/EU (EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/EEC (Tele-
kommunikationsendeinrichtungen, falls zutreffend), 2014/53/EU (Funkanlagen und Telekommunikation-
sendeinrichtungen, falls zutreffend).
Español: Este equipo cumple los requisitos esenciales y otras disposiciones de las directivas 2014/30/EU
(EMC), 2014/35/EU (LVD), 2011/65/EU (RoHS-Directive), 91/263/EEC (equipos terminales de teleco-
municación, si procede), 2014/53/EU (R&TTE, si procede).

Waste Electrical and Electronic Equipment (WEEE)


Statement
The product at end of life is subject to separate collection and treatment in the EU Member States, Norway
and Switzerland and therefore marked with the following symbol:

Treatment applied at end of life of the product in these countries shall comply with the applicable national
laws implementing directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-1


China RoHS: Hazardous Substance Table Regulatory Compliance and Safety Information

China RoHS: Hazardous Substance Table

page A-2 OmniSwitch 2x60 Hardware Users Guide July 2021


Regulatory Compliance and Safety Information Taiwan RoHS: Hazardous Substance Table

Taiwan RoHS: Hazardous Substance Table

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-3


California Proposition 65 Warning Regulatory Compliance and Safety Information

California Proposition 65 Warning


WARNING: This product can expose you to chemicals including Pb and Pb compounds, which is known
to the State of California to cause cancer and birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov.
Products are packaged using one or more of the following packaging materials:

CB FB

Corrugated Cardboard Corrugated Fiberboard Low-Density Polyethylene

page A-4 OmniSwitch 2x60 Hardware Users Guide July 2021


Regulatory Compliance and Safety Information Standards Compliance

Standards Compliance
The product bears the CE mark. In addition it is in compliance with the following other safety and
EMC standards.

Note. All hardware switching modules used in an OmniSwitch switch comply with Class A
standards. Modules with copper connectors meet Class A requirements using unshielded (UTP) cables.

Safety Standards
• US UL 60950-1

• IEC 60950-1 Health and Safety

• CAN/CSA-C22.2 No. 60950-1-03

• NOM-019 SCFI, Mexico

• AS/NZ TS-001 and 60950:2000, Australia

• UL-AR, Argentina

• UL-GS Mark, Germany

• CU, EAC, Russia

• EN 60825-1 Laser

• EN 60825-2 Laser

• CDRH Laser

• IEC 60950-1/EN 60950 with all country deviations

• IEC 60950-1:2005, Second Edition

• CCC, China

• ANATEL, Brazil (Contact for availability)

• BSMI, Taiwan (Contact for availability)

• KCC, Korea (Contact for availability)

In compliance with UL/EN/IEC 62368-1:


This equipment is not suitable for use in locations where children are likely to be present.

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-5


Standards Compliance Regulatory Compliance and Safety Information

EMI/EMC Standards
• FCC Part 15:2012, Subpart B, Class A

• ICES–003:2012 Issue 5, Class A

• ANSI C63.4-2009

• FCC CRF Title 47 Subpart B (Class A)

• VCCI (Class A)

• AS/NZS 3548 (Class A)

• CE marking for European countries (Class A)

• EN 55032 (EMI & EMC)

• EN 61000-3-2

• EN 61000-3-3

• EN 55024 (Immunity)
• EN 61000-4-2
• EN 61000-4-3
• EN 61000-4-4
• EN 61000-4-5
• EN 61000-4-6
• EN 61000-4-8
• EN 61000-4-11
• IEEE 802.3: Hi-Pot Test
(2250 V DC on all Ethernet ports)

Environmental Standards
• IEC 60068-2-1
• IEC 60068-2-2
• IEC 60068-2-30
• IEC 60068-2-13
• IEC 60068-2-40
• IEC 60068-2-41
• IEC 6068-2-6
• IEC 60068-2-64
• IEC 60068-2-27
• GR-63-CORE
• MIL-STD-810F Method 516.5 IV
• MIL-STD-810F Method 516.5 C

page A-6 OmniSwitch 2x60 Hardware Users Guide July 2021


Regulatory Compliance and Safety Information Standards Compliance

FCC Class A, Part 15


This equipment has been tested and found to comply with the limits for Class A digital device pursuant to
Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in
this guide, may cause interference to radio communications.Operation of this equipment in a residential
area is likely to cause interference, in which case the user will be required to correct the interference at his
own expense.
The user is cautioned that changes and modifications made to the equipment without approval of the
manufacturer could void the user’s authority to operate this equipment.It is suggested that the user use
only shielded and grounded cables to ensure compliance with FCC Rules.
If this equipment does cause interference to radio or television reception, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient the receiving antenna.

• Relocate the equipment with respect to the receiver.

• Move the equipment away from the receiver.

• Plug the equipment into a different outlet so that equipment and receiver are on different branch
circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional
suggestions.

Canada Class A Statement


This equipment does not exceed Class A limits per radio noise emissions for digital apparatus, set out in
the Radio Interference Regulation of the Canadian Department of Communications.

Avis de conformitè aux normes du ministère des Communications du Canada


Cet èquipement ne dèpasse pas les limites de Classe A d íèmission de bruits radioèlectriques pour les
appareils numèriques,telles que prescrites par le RÈglement sur le brouillage radioèlectrique ètabli par le
ministère des Communications du Canada.

JATE
This equipment meets the requirements of the Japan Approvals Institute of Telecommunications
Equipment (JATE).

CISPR22 Class A warning


This is a Class A product. In a domestic environment, this product may cause radio interference. Under
such circumstances, the user may be requested to take appropriate countermeasures.

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-7


Standards Compliance Regulatory Compliance and Safety Information

Korea Emissions Statement

A 급 기기 ( 업무용 방송통신 기자재 ) Class A Equipment (Business equipment)


이 기기는 업무용 (A 급 ) 전자파적합기기로서 판 This equipment is registered for Electromagnetic
매자 또는 사용자는 이 점을 주의하시기 바라
Conformity Registration as business equipment
(A), not home equipment. Sellers or users are
며 , 가정외의 지역에서 사용하는 것을 목적으 required to take caution in this regard.
로 합니다 .

VCCI
This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

Class A Warning for Taiwan and Other Chinese Markets


This is a Class A Information Product. When used in a residential environment, it may cause radio
frequency interference. Under such circumstances, the user may be requested to take appropriate
countermeasure.

Class 1M Laser Warning


CLASS 1M LASER RADIATION WHEN OPEN. DO NOT VIEW DIRECTLY WITH OPTICAL
INSTRUMENTS.

Network Cable Installation Warning


Never install exposed network cables outdoors. Install network cables per manufacturer requirements.

page A-8 OmniSwitch 2x60 Hardware Users Guide July 2021


Regulatory Compliance and Safety Information Translated Safety Warnings

Translated Safety Warnings


Blank Panels Warning
Because they regulate airflow and help protect internal chassis components, blank cover plates should
remain installed at empty module slots and power supply bays at all times.
Français: Les caches blancs remplissent trois fonctions importantes: ils évitent tout risque de choc
électrique à l'intérieur du châssis, ils font barrage aux interférences électromagnétiques susceptibles
d'altérer le fonctionnement des autres équipements et ils dirigent le flux d'air de refroidissement dans le
châssis. Il est vivement recommandé de vérifier que tous les caches, modules d'alimentation et plaques de
protection sont en place avant d'utiliser le système.
Deutsch: Die leeren Modulblenden schützen interne Komponenten und leiten den Luftstrom. Deshalb
müssen in allen unbelegten Slots die Modulblenden immer installiert bleiben.
Español: Las tapaderas blancas regulan la circulación de aire y ayudan a proteger componentes internos
del chasis y siempre deben estar instaladas en las ranuras vacías del chasis y fuentes de alimentación.

Electrical Storm Warning


To avoid a shock hazard, do not connect or disconnect any cables or perform installation, maintenance, or
reconfiguration of this product during an electrical storm.
Français: Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Deutsch: Um elektrische Schläge zu vermeiden dürfen während eines Gewitters an diesem Gerät keine
Kabel angeschlossen oder gelöst werden, sowie keinerlei Installationen, Wartungen oder Konfigurationen
vorgenommen werden.
Español: Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna
instalación, maintenimiento o reconfiguración de este producto durante una tormenta eléctrica.

Installation Warning
Only personnel knowledgeable in basic electrical and mechanical procedures should install or maintain
this equipment.
Français: Toute installation ou remplacement de l'appareil doit être réalisée par du personnel qualifié et
compétent.
Deutsch: Dieses Gerät soll nur von Personal installiert oder gewartet werden, welches in elektrischen und
mechanischen Grundlagen ausgebildet ist.
Español: Estos equipos deben ser instalados y atendidos exclusivamente por personal adecuadamente
formado y capacitado en técnicas eléctricas y mecánicas.

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-9


Translated Safety Warnings Regulatory Compliance and Safety Information

Invisible Laser Radiation Warning


Lasers emit invisible radiation from the aperture opening when no fiber-optic cable is connected. When
removing cables do not stare into the open apertures. In addition, install protective aperture covers to fiber
ports with no cable connected.
Français: Des radiations invisibles à l'œil nu pouvant traverser l'ouverture du port lorsque aucun câble en
fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Installez les caches connecteurs prévus à cet effet.
Deutsch: Die Laser strahlen an der Blendenöffnung unsichtbares Licht ab, wenn keine Glasfaserkabel
angeschlossen sind. Blicken Sie nicht in die Öffnungen und installieren Sie unverzüglich die Abdeckungen
über den Glasfaseranschlüssen.
Español: Debido a que la apertura del puerto puede emitir radiación invisible cuando no hay un cable de
fibra conectado, procurar no mirar directamente a las aperturas para no exponerse a la radiación.

Operating Voltage Warning


To reduce the risk of electrical shock, keep your hands and fingers out of power supply bays and do not
touch the backplane while the switch is operating.
Français: Pour réduire tout risque électrique, gardez vos mains et doigts hors des alimentations et ne
touchez pas au fond de panier pendant que le commutateur fonctionne.
Deutsch: Um die Gefahr des elektrischen Schlages zu verringern, greifen sie bitte nicht in die
Spannungsversorgung und berühren sie nicht die Rückwandplatine während das Gerät arbeitet.
Español: Para reducir el riesgo de descargas eléctricas, no meta sus manos y dedos dentro del chasis de la
fuente de alimentación y no toque componentes internos mientras que el interruptor está conectado.

Power Disconnection Warning


Your switch is equipped with multiple power supplies. To reduce the risk of electrical shock, be sure to
disconnect all power connections before servicing or moving the unit.
Français: Il se peut que cette unité soit équipée de plusieurs raccordements d'alimentation. Pour
supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.
Deutsch: Ihr Gerät ist mit mehreren Netzteilen ausgerüstet. Um die Gefahr des elektrischen Schlages zu
verringern, stellen sie sicher, daß alle Netzverbindungen getrennt sind bevor das Gerät gewartet oder
bewegt wird.
Español: Antes de empezar a trabajar con un sistema, asegurese que el interruptor está cerrado y el cable
eléctrico desconectado.

page A-10 OmniSwitch 2x60 Hardware Users Guide July 2021


Regulatory Compliance and Safety Information DC Power Supply Connection Warning

Proper Earthing Requirement Warning


To avoid shock hazard:
• The power cord must be connected to a properly wired and earth receptacle.
• Any equipment to which this product will attached must also be connected to properly wired
receptacles.
Français:
Pour éviter tout risque de choc électrique:
• Ne jamais rendre inopérant le conducteur de masse ni utiliser l'équipement sans un conducteur de
masse adéquatement installé.
• En cas de doute sur la mise à la masse appropriée disponible, s'adresser à l'organisme responsable de
la sécurité électrique ou à un électricien.
Deutsch:
Aus Sicherheitsgründen:
• darf das Netzkabel nur an eine Schutzkontaktsteckdose angeschlossen werden.
• dürfen für den Anschluß anderer Geräte, welche mit diesem Gerät verbunden sind, auch nur
Schutzkontaktsteckdosen verwendet werden.
Español:
Para evitar peligro de descargas:
• Para evitar peligro de descargas asegurese de que el cable de alimentación está conectado a una
toma de alimentación adecuadamente cableada y con toma de tierra.
• Cualquier otro equipo a cual se conecte este producto también debe estar conectado a tomas de
alimentación adecuadamente cableadas.

DC Power Supply Connection Warning


For EMC/EMI, each DC/DC power supply requires that the ground wire is connected from each DC/DC
power supply to Common Earth Ground.
Français: Pour EMC/EMI, pour chaque alimentation DC/DC, il est impératif que le fil de terre soit
branché à la prise de terre commune.
Deutsch: Zur Erfüllung der EMV-/EMI-Anforderungen muss das Erdungskabel jedes DC/DC-Netzteils an
eine gemeinsame Erde angeschlossen werden.
Español: Para EMC/EMI, cada fuente de alimentación de CC/CC requiere que el cable de tierra esté
conectado desde cada fuente de alimentación de CC/CC a la conexión a tierra común.

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-11


DC Power Supply Connection Warning Regulatory Compliance and Safety Information

Read Important Safety Information Warning


The Getting Started Chapter that accompanied this equipment contains important safety information about
which you should be aware when working with hardware components in this system. You should read this
guide before installing, using, or servicing this equipment.
Français: Avant de brancher le système sur la source d'alimentation, consultez les directives d'installation
disponibles dans le “Getting Started Chapter”.
Deutsch: Der Getting Started Chapter, welcher dieser Anlage beiliegt, enthält wichtige
Sicherheitsinformationen, über die sie sich beim Arbeiten mit den Hardwareeinheiten bewußt sein sollten.
Sie sollten diese Hinweise lesen, bevor sie installieren, reparieren oder die Anlage verwenden.
Español: La 'Getting Started Chapter' que acompañó este equipo contiene información importante de
seguridad sobre la cual usted debe estar enterado al trabajar con los componentes de dotación física en este
sistema. Usted debe leer esta guía antes de instalar, usar o mantener este equipo.

Restricted Access Location Warning


This equipment should be installed in a location that restricts access. A restricted access location is one
where access is secure and limited to service personnel who have a special key, or other means of security.
Français: Le matériel doit être installé dans un local avec accès limité ou seules les personnes habilitées
peuvent entrer.
Deutsch: Die Anlage sollte an einem Standort mit beschränktem Zutritt installiert sein. Ein Standort mit
beschränktem Zutritt stellt sicher, daß dort nur Servicepersonal mit Hilfe eines Schlüssels oder eines
anderen Sicherheitssystems Zugang hat.
Español: Este equipo se debe instalar en un sitio con acceso restrinjido. Un sitio con el acceso restrinjido
es uno seguro y con acceso limitado al personal de servicio que tiene una clave especial u otros medios de
seguridad.

Wrist Strap Warning


Because electrostatic discharge (ESD) can damage switch components, you must follow proper procedures
to eliminate ESD from your person and the surrounding area before handling switch components.
Français: Parce que les décharges électrostatiques (ESD) peuvent endommager les composants de
commutation, vous devez suivre les procédures appropriées pour éliminer ESD de votre personne et la
région environnante avant de manipuler les composants de commutation.
Deutsch: Da elektrostatische Entladung (ESD) Komponenten beschädigen können, müssen geeignete
Verfahren getroffen werden, diese elektrostatische Entladung bedingt durch Ihre Person oder der
Umgebung zu beseitigen.
Español: Debido a las descargas electrostáticas (ESD) puede dañar los componentes del interruptor, debe
seguir los procedimientos adecuados para eliminar la EDS de su persona y sus alrededores antes de
manipular los componentes del interruptor.

page A-12 OmniSwitch 2x60 Hardware Users Guide July 2021


Regulatory Compliance and Safety Information Instrucciones de seguridad en español

Instrucciones de seguridad en español


Advertencia sobre el levantamiento del chasis
Se requieren dos personas para levantar el chasis. Debido a su peso, la elevación del chasis sin ayuda
puede causar daños corporales. También es seguro doblar sus rodillas y guardar su espalda derecho al
ayudar a levantar el chasis.

Advertencia de las tapaderas en blanco


Porque regulan la circulación de aire y ayudan a proteger componentes internos del chasis, las tapaderas
en blanco deben seguir instaladas en las ranuras vacías del módulo y la fuente de alimentación siempre.

Advertencia en caso de tormenta eléctrica


Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna instalación,
maintenimiento o reconfiguratión de este producto durante una tormenta eléctrica.

Advertencia de instalación
Solamente el personal bien informado en procedimientos eléctricos y mecánicos básicos debe instalar o
mantener este equipo.

Advertencia de radiación láser invisible


Los lasers emiten radiación invisible de la apertura abierta cuando no se conecta ningún cable de fibra
óptica. Al quitar los cables no mire fijamente en las aberturas abiertas. Además, instale las cubiertas
protectoras de la abertura a las salidas de la fibra sin el cable conectado.

Advertencia de la batería de litio


Hay un peligro de la explosión si la batería del litio en su chasis se substituye incorrectamente. Substituya
la batería solamente por el mismo o el equivalente de tipo de batería recomendado por el fabricante.
Deseche las baterías usadas según las instrucciones del fabricante. Las instrucciones del fabricante son
como sigue: Devuelva el módulo con la batería del litio a Alcatel-Lucent. La batería del litio será
substituida en la fábrica de Alcatel-Lucent.

Advertencia sobre la tensión de operación


Para reducir el riesgo del choque eléctrico, matenga sus manos y dedos fuera de la fuente de alimentación
y no toque la placa madre mientras que el interruptor está funcionando.

Advertencia sobre la desconexión de la fuente


Su interruptor esta equipado por fuentes de alimentación múltiples. Para reducir el riesgo de choque
eléctrico, asegúrese desconectar todas las conexiones de alimentación antes de mantener o de mover la
unidad.

OmniSwitch 2x60 Hardware Users Guide July 2021 page A-13


Instrucciones de seguridad en español Regulatory Compliance and Safety Information

Advertencia sobre una apropiada conexión a tierra


Para evitar peligro de descargas:
• El cable de alimentación debe estar conectado a una toma de alimentación adecuadamente cableada
y con toma de tierra.
Cualquier equipo al cual se conecte este producto debe estar también conectado a tomas de alimentación
adecuadamente cableadas.

Leer “información importante de seguridad”


La Guía de “Comenzando a Usar” que acompaña este equipo contiene información importante de
seguridad sobre la cual usted debe saber al trabajar con los componentes de dotación física en este sistema.
Usted debe leer esta guía antes de instalar, de usar, o de mantener este equipo.

Advertencia de acceso restringido


Este equipo se debe instalar en una ubicación que restrinja el acceso. Una ubicación con acceso restringido
es una donde está seguro y limitado el acceso al personal de servicio que tiene un clave especial, u otros
medios de la seguridad.

Advertencia de pulsera antiestática


Debido a que la descarga electrostática (ESD) puede dañar componentes del interruptor, usted debe
conectarse a tierra correctamente antes de continuar con la instalación del equipo. Para este propósito,
Alcatel-Lucent proporciona una pulsera antiestática y un terminal que pone a tierra situados cerca de la
parte superior derecha del chasis. Para que la pulsera antiestática sea eficaz en la eliminación de ESD, las
fuentes de alimentación se deben instalar en el chasis y enchufar en las salidas de CA con descarga a
tierra.

Clase de seguridad
Cumple con 21CFR 1040.10 y 1040.11 ó sus equivalentes.

Advertencia de fuentes de poder


Las unidades OmniSwitch pueden estar equipadas con tres cordones para fuente de poder. Para reducir el
riesgo de un choque electrico, desconecte todos los cordones de fuente de poder antes de dar servicio a la
unidad.

page A-14 OmniSwitch 2x60 Hardware Users Guide July 2021