Installation and Assembly Instructions

for Solar Modules

WARNING!
The photovoltaic module produces electricity when exposed to the sun or
other light sources. For your safety and the safety of others, please read
the entire Installation and Assembly Instruction manual carefully prior to
installation. Please carefully read the following installation and safety
instructions. Non-compliance with these instructions may void the module
warranty.

1. Company Introduction
ET Solar Group is a vertically integrated solar energy equipment manufacturer and
turnkey solutions provider. With local sales and marketing subsidiaries and offices
throughout Asia, Europe, and North America, we provide high quality photovoltaic
modules, world leading solar tracking systems and smart turnkey solutions to our
customers in more than 50 countries and areas. Our products have been delivering strong
operating performance in a large number of residential and utility scaled solar PV
projects around the world.

2. Structure of module
ET modules are made by layering low-iron-tempered glass, an EVA sticky membrane,
high conversion-efficient solar cells and a behind-the-membrane multi-layer backsheet.
These elements are laminated into a plate by being heated in a vacuum. After installing
the aluminum alloy frame and wiring compartment, a module is born (see Fig. 1)
.

1
www.etsolar.com

Fig.1: Front and back sides of ET-M572170 module

3. Installation of modules

WARNING!
Do not attempt to clean a module with a broken glass cover or a
perforated backsheet. Such a module can present a serious shock
hazard.

3.1 Installation
When installing the modules, the face of the units should be placed where they are highly
exposed to the sun. It is recommended that the modules usually face the equator; thus, in
the Northern Hemisphere the surface should be oriented towards the south, and in the
Southern Hemisphere, towards the north. Usually the angle between modules and the
ground should be local latitude ± (5°~10°) as show in Fig.2.

2
www.etsolar.com

The recommended standoff height is 5 in. (127mm), if other mounting means are
employed this may affect the UL Listing.

The specific angle depends on the sunlight condition, local climate and the actual
application requirements. The appropriate angle of evaluation has a very important
relationship to the output power of the modules and the cost of the construction. The
surface of the modules should avoid shadows and be kept clean from foreign materials
such as dirt.

The assembly is to be mounted over a fire resistant roof covering material when roof
mounting is intended for the modules, the fire resistance of roof covering or wall should
be rated for the application.

WARNING!
The local shadowing of modules may cause serious hot-spots and
damage the modules.
The modules are for use in applications where they do not serve as
a member of the building primary structural frame.

A torsion and corrosion-resistant anodized aluminum frame ensures dependable


performance, even under harsh weather conditions. Eight pre-drilled mounting holes,

3
www.etsolar.com
located on the aluminum alloy frame, are provided for ease of installation. They are
designed to be used with metric M6×1(Torque 12 Lb-in) stainless steel screws.

Mounting with Bolts


• The module must be attached and supported by at least four bolts through the
indicated mounting holes.
• Most installations will use the four inner mounting holes on the module frame.
• Depending on the local wind and snow loads, additional mounting points may be
required(e.g. if the combined wind and snow load is as high as 5400pa, please use eight
bolts).

Mounting with Clamps


• If module clamps are used to secure the module, the torque on the clamp bolt
should be around 8–10 Nm.
• A minimum of four module clamps should be used, two on each long frame side,
in the general clamping areas denoted by the wide arrows on the drawing.
• Depending on the local wind and snow loads, additional module clamps may be
required(e.g. if the combined wind and snow load is as high as 5400pa, please use eight
clamps).

4
www.etsolar.com

Figure 3 Module mounting with clamps


TM
Zero-Rack modules mounting with Zep Compatible hardwares
• The array of Zero-RackTM modules must be mounted to the roof with Zep Leveling
Feet and suitable roof attachment devices to maintain the waterproof integrity of the roof.
The system designer and/or installer are responsible for load calculation and proper
quantity and locations of the Zep Leveling Feet. Local wind loading and snow loading
should be accounted for in the system design.
• The mounting system design shall comply with all local building codes.
• A minimum gap of 0.25” between modules is required to allow for
thermal expansion.
• The system must not be immersed in water or constantly exposed to
water spray.

Figure 4 Zero-RackTM Series Module mounting with Zep


Compatible hardware

WARNING!
The Fire Rating of this module series is Class “C”.
The design mechanical load is 30psf

5
www.etsolar.com
Grounding of normal modules : All permanently mounted modules have to be
provided with appropriate grounding. The grounding lug should be suitable for outdoor
use with aluminum. The grounding method of the frame of arrays shall comply with the
NEC, article 250 and also meet UL 1703 standard. Lay-in-Lug ground part with 32
threads per inch (e.g., the lay-in-lug with UL file number E34440, part # GBL-4DBT)
should be mounted to one of the 4 mm diameter grounding holes marked as grounding
hole on the frame.

When the module system is used, it should be connected to the ground reliably. The
ground wire should be a naked copper wire with surface coating only and with no
insulation jacket. The area of cross-section of wire should be sized in accordance with the
prime current carrying conductor. The area of cross-section of wire should meet the NEC,
article 250. Installation in Canada shall be in accordance with CSA C22.1, Safety
Standard for Electrical Installations, Canadian Electrical Code, Part 1 ( refer Figure 5) .

Fig 5. PV module grounding with lay in lug (φ4mm grounding holes)

The lay-in grounding lug, manufactured by ILSCO, type GBL-4DBT installed to frame
using #10-32 inch stainless steel screw, secured to hole opening by star washer, flat
washer, split washer and nut, All hardware used is stainless steel. The starwasher is used
to break the coating of the frame to obtain reliable grounding termination. Recommended
#10-32 inch stainless steel screw assembly torque is 13.5 lb.inch(1.5 N.m), Next, insert
the grounding wire (10-12AWG exposed copper wire is recommended) to the feet of the
lug, and screw down the slotted screw(recommended torque is 13.5 lb.inch(1.5 N.m)). Be
careful not to damage the wire copper.

6
www.etsolar.com

Fig 6. Module to grounding rod


TM
Grounding of Zero-Rack modules: To connect the array to a grounding system,
install a Ground Zep in the Zep Groove of a module. Install one Ground Zep for every
section of array that is not conductively isolated by a thermal expansion joint (up to 72
modules per Ground Zep). See below for more information on thermal expansion joints.

Use the Ground Zep “Driver” on the Zep Tool to insert the Ground Zep “Key
” into the Module groove. Rotate exactly one quarter turn clockwise.

Insert Equipment Grounding Conductor (EGC) into wire slot and tighten set
screw to proper torque setting (see table to the below).

7
www.etsolar.com


The detail information see below website:
http://www.etsolar.com/upload/Zero_Rack_Presentation_PV_America.pdf

8
www.etsolar.com
3.2 Fire Safty
Consult your local authority for guidelines and requirements for building or structural fire
safety.
Roof constructions and installations may affect the fire safety of a building; improper
installation may create hazards in the event of a fire.
Use components such as ground fault circuit breakers and fuses as required by local
authority.
Do not use panels near equipment or in places where flammable gases may be generated.
The modules have been rated Fire Class C, and are suitable for mounting on to a Class A
roof.
Confirm mounting slope less than 5 in/ft (127mm/305mm) to maintain a fire class rating
Observe the linear thermal expansion of the module frames (the recommended minimum
distance between two modules is 1 cm).

3.3 Junction box


The junction box should be fixed on the top end of the module during assembly so as to
prevent the seepage of rain.

ET Solar provides a wiring type box. When the integrated J-box is adopted, no tool is
necessary for wiring. Just connect the modules in series according to “+” or “-”. You
can complete complex series and parallel connection easily and quickly using different
electric connectors provided by your supplier.

Connectors provided by different suppliers will not mutually match up. Different
connectors provided by one supplier will not match up either. Only one type of the same
connector from one supplier should be used to ensure the reliability of the electrical
connection.
Module Male connector Female Manufacturer Notes
connector
Tyco Electronics
ETP672series
1394461-2 1394462-4 Amp GMBH
ETP654 series 12AWG wire
PV-KST4 PV-KBT4 Multi-Contact
ETP660 series
USA
ETM572 series Multi-Contact
PV-KST3 PV-KBT3 12AWG wire
ETM536 series USA

9
www.etsolar.com
There are other options in addition to using a wiring type junction box only consisting of
two terminals marked with "+" and "-" to represent the positive and negative terminals of
the power supply. Some junction boxes include three or more terminals. Only those
terminals indicated with "+" and "-" should be connected to the load. The others are
designed for the bypass diodes to reduce the damage to modules caused by hot spots and
to ensure undisrupted electrical energy output from the array. The hex nut in the exit
position on the junction box is used to hold a rubber ring to seal the box.

When disconnecting the connectors of a photovoltaic module in a module array that is


exposed to sunlight, electric arcs may result. Such arcs may cause burns and fires.
Therefore, PV system commissioning and maintenance must be performed by a qualified
electrician in accordance with the NEC. Before disconnecting a module in a solar array,
disconnect the string of module from the DC Disconnect at the inverter side, and then
fully cover the module with an opaque material. Do not short the positive and the
negative connectors of a module exposed to sunlight.

WARNING!
Wiring must only be completed by a qualified engineer with
suitable tools.

The specification of wire for the electric coupler that ET Solar provided is 1 x 4.0mm2.
Equivalent wire should be used if the user prefers to use his own wire. When the
module’s rated current is lower, 12AWG wire is recommended for use, and the strength
of the wire should be taken into consideration. ET Solar does not provide any output
wiring for module installation.

ET Solar modules are designed to use copper wire only. The Wiring used is UL listed.
Manufactured by Suzhou Baohing Electric Wire & Cable Co Ltd. Rated 600 V,
temperature rating 90 °C ,wet or dry, Sunlight Resistant, 12 AWG, Type PV Wire.

The installation in Canada shall be in accordance with CSA C22.1, Safety standard for
electrical installations, Canadian Electrical Code, Part 1.

10
www.etsolar.com
3.4 Output Voltage, Current and Maximum Power
The open-circuit voltage (Voc), short-circuit current (Isc) and maximal power (Pmax) are
printed on the PET label on the backside of the module. The electrical characteristics are
within ±10 percent of the indicated values of Isc, Voc and Pmax under standard test
conditions (irradiance of 100 mW/cm2, AM1.5 spectrum, and a cell temperature of 25oC
(77oF)).

Under normal conditions, a photovoltaic module is likely to experience conditions that


produce more current and/or voltage than reported at standard test conditions.
Accordingly, the values of Isc and Voc marked on this module should be multiplied by a
factor of 1.25 when determining component voltage ratings, conductor capacities, fuse
sizes, and size of controls connected to the PV output. If modules are to be installed in
parallel (electrically), each module (or series string of modules so connected) shall be
provided with the maximum series fuse as specified.

WARNING!
In order to avoid electric shock and scalding, it is necessary to
cover the surface of the module with a suitable material to prevent
incidental light contacting the modules during the connection
process.

The modules will generate electrical energy under sunlight and other light sources.

Refer to Section 690-8 of the National Electrical Code for an additional multiplying
factor of 125 percent (80 percent derating) which may be applicable.
4. Characteristics of Modules

WARNING!
The product is designed as a plain plate type that should not
be irradiated directly under concentrated light.

11
www.etsolar.com
The array consists of modules in series and parallel and has a similar electrical curve to
that of a single module. In order to output maximum electrical power to the load, try to
make the impedance of the load match the electric performance of the module or array. In
order to maintain the stability of the system, also pay attention to the changes in the
electric curve of modules, especially under weak light. In more complex control circuits,
the controller supplier may have already adopted microprocessors for the tracking of
maximum power output. For the best impedance matching and the best tracking of
maximum power output, please refer to other relevant documents regarding these issues.

Electrical ratings of ET Solar modules are as follows. The detailed specs should refer to
module datasheet.

Open Rated Maximu Rated Short Rated Maxi


circuit Voltage m system current at circuit maximum mum
voltage at voltage(V STC(A current at power at series
Model
at STC(Vdc dc) dc) STC(Adc) STC(watt fuse(
STC(Vd ) s) A)
c)
ETM53670 21.45 16.90 600 4.14 4.45 70 8
ETM53675 21.73 17.40 600 4.31 4.72 75
ETM53680 21.88 17.64 600 4.54 4.98 80
ETM53685 21.94 18.05 600 4.71 5.29 85
ETM572155 43.30 35.20 600 4.40 4.98 155 10
ETM572160 43.90 35.26 600 4.49 5.07 160
ETM572165 44.12 35.68 600 4.60 5.19 165
ETM572170 44.16 36.13 600 4.71 5.30 170
ETM572175 44.25 36.24 600 4.83 5.50 175
ETM572180 44.60 36.30 600 4.95 5.61 180
ETM572185 44.60 36.30 600 5.09 5.80 185
ETM572190 44.85 36.89 600 5.15 5.64 190
ETM572195 45.20 37.43 600 5.21 5.75 195
ETM572200 45.45 37.88 600 5.28 5.87 200
ETM572205 45.53 37.95 600 5.40 5.99 205
ET-P636115 21.75 17.20 600 6.68 7.55 115 15
ET-P636120 21.75 17.40 600 6.89 7.63 120
ET-P636125 21.75 17.40 600 7.18 7.80 125
ET-P636130 21.75 17.41 600 7.47 8.10 130
ET-P636135 21.96 17.60 600 7.67 8.41 135
ET-P636140 22.54 17.95 600 7.80 8.42 140

12
www.etsolar.com
ET-P654180 32.35 26.45 600 6.81 7.60 180
ET-P654185 32.30 26.45 600 6.99 7.70 185
ET-P654190 32.50 26.78 600 7.10 7.72 190
ET-P654195 32.75 27.00 600 7.22 7.98 195
ET-P654200 33.20 25.80 600 7.75 8.26 200
ET-P654205 32.80 27.30 600 7.50 8.10 205
ET-P654210 32.83 27.54 600 7.63 8.30 210
ET-P654215 33.20 27.54 600 7.81 8.50 215
ET-P654220 33.20 27.54 600 7.81 8.50 220
ET-P654225 33.70 28.33 600 7.94 8.78 225
ET-P660200 36.00 28.75 600 7.70 7.71 200
ET-P660205 36.00 28.75 600 7.13 7.80 205
ET-P660210 36.00 28.75 600 7.30 7.99 210
ET-P660215 36.00 29.00 600 7.41 8.10 215
ET-P660220 36.30 29.00 600 7.58 8.10 220
ET-P660225 36.68 29.58 600 7.61 8.25 225
ET-P660230 36.75 29.64 600 7.76 8.33 230
ET-P660235 37.08 29.83 600 7.88 8.50 235
ET-P660240 37.17 29.96 600 8.02 8.58 240
ET-P660245 37.27 30.14 600 8.13 8.73 245
ET-P660250 37.47 30.34 600 8.24 8.76 250
ET-P660255 37.54 30.91 600 8.25 8.82 255
ET-P660260 38.09 31.48 600 8.26 8.84 260
ET-P660265 38.59 32.01 600 8.28 8.85 265
ET-P672230 43.56 34.20 600 6.75 7.32 230
ET-P672235 43.56 34.20 600 6.87 7.45 235
ET-P672240 43.85 34.95 600 6.88 7.63 240
ET-P672245 43.85 34.95 600 7.01 7.70 245
ET-P672250 43.88 35.20 600 7.12 7.81 250
ET-P672255 43.88 35.20 600 7.24 7.85 255
ET-P672260 43.49 34.80 600 7.47 7.88 260
ET-P672265 43.63 36.40 600 7.28 7.90 265
ET-P672270 44.16 35.48 600 7.61 8.21 270
ET-P672275 44.18 35.52 600 7.75 8.26 275
ET-P672280 44.27 35.54 600 7.88 8.48 280
ET-P672285 44.72 35.86 600 7.95 8.55 285 15
ET-P672290 44.75 35.92 600 8.08 8.62 290
ET-P672295 44.78 36.17 600 8.16 8.68 295
ET-P672300 44.89 36.68 600 8.18 8.72 300
ET-P672305 45.12 37.18 600 8.21 8.78 305
ET-P672310 45.80 37.71 600 8.23 8.79 310
ET-P672315 46.43 38.23 600 8.24 8.81 315
ET-P672320 46.51 38.79 600 8.25 8.82 320

13
www.etsolar.com

Open Rated Maximu Rated Short Rated Maxi


circuit Voltage m system current at circuit maximum mum
voltage at voltage(V STC(A current at power at series
Model
at STC(Vdc dc) dc) STC(Adc) STC(watt fuse(
STC(Vdc ) s) A)
)
ETM53670B 21.45 16.90 600 4.14 4.45 70 8
ETM53675B 21.73 17.40 600 4.31 4.72 75
ETM53680B 21.88 17.64 600 4.54 4.98 80
ETM53685B 21.94 18.05 600 4.71 5.29 85
ETM572155B 43.30 35.20 600 4.40 4.98 155 10
ETM572160B 43.90 35.26 600 4.49 5.07 160
ETM572165B 44.12 35.68 600 4.60 5.19 165
ETM572170B 44.16 36.13 600 4.71 5.30 170
ETM572175B 44.25 36.24 600 4.83 5.50 175
ETM572180B 44.60 36.30 600 4.95 5.61 180
ETM572185B 44.60 36.30 600 5.09 5.80 185
ETM572190B 44.85 36.89 600 5.15 5.64 190
ETM572195B 45.20 37.43 600 5.21 5.75 195
ETM572200B 45.45 37.88 600 5.28 5.87 200
ETM572205B 45.53 37.95 600 5.40 5.99 205
ET-P636115B 21.75 17.20 600 6.68 7.55 115 15
ET-P636120B 21.75 17.40 600 6.89 7.63 120
ET-P636125B 21.75 17.40 600 7.18 7.80 125
ET-P636130B 21.75 17.41 600 7.47 8.10 130
ET-P636135B 21.96 17.60 600 7.67 8.41 135
ET-P636140B 22.54 17.95 600 7.80 8.42 140
ET-P654180B 32.35 26.45 600 6.81 7.60 180
ET-P654185B 32.30 26.45 600 6.99 7.70 185
ET-P654190B 32.50 26.78 600 7.10 7.72 190
ET-P654195B 32.75 27.00 600 7.22 7.98 195
ET-P654200B 33.20 25.80 600 7.75 8.26 200
ET-P654205B 32.80 27.30 600 7.50 8.10 205
ET-P654210B 32.83 27.54 600 7.63 8.30 210
ET-P654215B 33.20 27.54 600 7.81 8.50 215
ET-P654220B 33.20 27.54 600 7.81 8.50 220
ET-P654225B 33.70 28.33 600 7.94 8.78 225
ET-P660200B 36.00 28.75 600 7.70 7.71 200
ET-P660205B 36.00 28.75 600 7.13 7.80 205
ET-P660210B 36.00 28.75 600 7.30 7.99 210
ET-P660215B 36.00 29.00 600 7.41 8.10 215
ET-P660220B 36.30 29.00 600 7.58 8.10 220
ET-P660225B 36.68 29.58 600 7.61 8.25 225

14
www.etsolar.com
ET-P660230B 36.75 29.64 600 7.76 8.33 230
ET-P660235B 37.08 29.83 600 7.88 8.50 235
ET-P660240B 37.17 29.96 600 8.02 8.58 240
ET-P660245B 37.27 30.14 600 8.13 8.73 245
ET-P660250B 37.47 30.34 600 8.24 8.76 250
ET-P660255B 37.54 30.91 600 8.25 8.82 255
ET-P660260B 38.09 31.48 600 8.26 8.84 260
ET-P660265B 38.59 32.01 600 8.28 8.85 265
ET-P672230B 43.56 34.20 600 6.75 7.32 230
ET-P672235B 43.56 34.20 600 6.87 7.45 235
ET-P672240B 43.85 34.95 600 6.88 7.63 240
ET-P672245B 43.85 34.95 600 7.01 7.70 245
ET-P672250B 43.88 35.20 600 7.12 7.81 250
ET-P672255B 43.88 35.20 600 7.24 7.85 255
ET-P672260B 43.49 34.80 600 7.47 8.18 260
ET-P672265B 43.63 36.40 600 7.28 7.90 265
ET-P672270B 44.16 35.48 600 7.61 8.21 270
ET-P672275B 44.18 35.52 600 7.75 8.26 275
ET-P672280B 44.27 35.54 600 7.88 8.48 280
ET-P672285B 44.72 35.86 600 7.95 8.55 285
ET-P672290B 44.75 35.92 600 8.08 8.62 290
ET-P672295B 44.78 36.17 600 8.16 8.68 295
ET-P672300B 44.89 36.68 600 8.18 8.72 300
ET-P672305B 45.12 37.18 600 8.21 8.78 305
ET-P672310B 45.80 37.71 600 8.23 8.79 310 15
ET-P672315B 46.43 38.23 600 8.24 8.81 315
ET-P672320B 46.51 38.79 600 8.25 8.82 320

Open Rated Maximu Rated Short Rated Maxi


circuit Voltage m system current at circuit maximum mum
voltage at voltage(V STC(A current at power at series
Model
at STC(Vdc dc) dc) STC(Adc) STC(watt fuse(
STC(V ) s) A)
dc)
ETM572155WWZ 43.30 35.20 600 4.40 4.98 155 10
ETM572160WWZ 43.90 35.26 600 4.49 5.07 160
ETM572165WWZ 44.12 35.68 600 4.60 5.19 165
ETM572170WWZ 44.16 36.13 600 4.71 5.30 170
ETM572175WWZ 44.25 36.24 600 4.83 5.50 175
ETM572180WWZ 44.60 36.30 600 4.95 5.61 180
ETM572185WWZ 44.60 36.30 600 5.09 5.80 185
ETM572190WWZ 44.85 36.89 600 5.15 5.64 190
ETM572195WWZ 45.20 37.43 600 5.21 5.75 195
ETM572200WWZ 45.45 37.88 600 5.28 5.87 200

15
www.etsolar.com
ETM572205WWZ 45.53 37.95 600 5.40 5.99 205
ET-P660200WWZ 36.00 28.75 600 7.70 7.71 200 15
ET-P660205WWZ 36.00 28.75 600 7.13 7.80 205
ET-P660210WWZ 36.00 28.75 600 7.30 7.99 210
ET-P660215WWZ 36.00 29.00 600 7.41 8.10 215
ET-P660220WWZ 36.30 29.00 600 7.58 8.10 220
ET-P660225WWZ 36.68 29.58 600 7.61 8.25 225
ET-P660230WWZ 36.75 29.64 600 7.76 8.33 230
ET-P660235WWZ 37.08 29.83 600 7.88 8.50 235
ET-P660240WWZ 37.17 29.96 600 8.02 8.58 240
ET-P660245WWZ 37.27 30.14 600 8.13 8.73 245
ET-P660250WWZ 37.47 30.34 600 8.24 8.76 250
ET-P660255WWZ 37.54 30.91 600 8.25 8.82 255 15
ET-P660260WWZ 38.09 31.48 600 8.26 8.84 260
ET-P660265WWZ 38.59 32.01 600 8.28 8.85 265

Open Rated Maximu Rated Short Rated Maxi


circuit Voltage m system current circuit maximum mum
voltage at voltage(V at STC(A current at power at series
Model
at STC(Vdc dc) dc) STC(Adc) STC(watt fuse(
STC(V ) s) A)
dc)
ETM572155BBZ 43.30 35.20 600 4.40 4.98 155 10
ETM572160BBZ 43.90 35.26 600 4.49 5.07 160
ETM572165BBZ 44.12 35.68 600 4.60 5.19 165
ETM572170BBZ 44.16 36.13 600 4.71 5.30 170
ETM572175BBZ 44.25 36.24 600 4.83 5.50 175
ETM572180BBZ 44.60 36.30 600 4.95 5.61 180
ETM572185BBZ 44.60 36.30 600 5.09 5.80 185
ETM572190BBZ 44.85 36.89 600 5.15 5.64 190
ETM572195BBZ 45.20 37.43 600 5.21 5.75 195
ETM572200BBZ 45.45 37.88 600 5.28 5.87 200
ETM572205BBZ 45.53 37.95 600 5.40 5.99 205
ET-P660200WBZ 36.00 28.75 600 7.70 7.71 200 15
ET-P660205WBZ 36.00 28.75 600 7.13 7.80 205
ET-P660210WBZ 36.00 28.75 600 7.3 7.99 210
ET-P660215WBZ 36.00 29.00 600 7.41 8.10 215
ET-P660220WBZ 36.30 29.00 600 7.58 8.10 220
ET-P660225WBZ 36.68 29.58 600 7.61 8.25 225
ET-P660230WBZ 36.75 29.64 600 7.76 8.33 230
ET-P660235WBZ 37.08 29.83 600 7.88 8.50 235
ET-P660240WBZ 37.17 29.96 600 8.02 8.58 240
ET-P660245WBZ 37.27 30.14 600 8.13 8.73 245
ET-P660250WBZ 37.47 30.34 600 8.24 8.76 250

16
www.etsolar.com
ET-P660255WBZ 37.54 30.91 600 8.25 8.82 255
ET-P660260WBZ 38.09 31.48 600 8.26 8.84 260
ET-P660265WBZ 38.59 32.01 600 8.28 8.85 265
Open Rated Maximu Rated Short Rated Maxi
circuit Voltage m system current circuit maximum mum
voltage at voltage(V at STC(A current at power at series
Model
at STC(Vdc dc) dc) STC(Adc) STC(watt fuse(
STC(V ) s) A)
dc)
ET-P660200BBZ 36.00 28.75 600 7.70 7.71 200 15
ET-P660205BBZ 36.00 28.75 600 7.13 7.80 205
ET-P660210BBZ 36.00 28.75 600 7.3 7.99 210
ET-P660215BBZ 36.00 29.00 600 7.41 8.10 215
ET-P660220BBZ 36.30 29.00 600 7.58 8.10 220
ET-P660225BBZ 36.68 29.58 600 7.61 8.25 225
ET-P660230BBZ 36.75 29.64 600 7.76 8.33 230
ET-P660235BBZ 37.08 29.83 600 7.88 8.50 235
ET-P660240BBZ 37.17 29.96 600 8.02 8.58 240
ET-P660245BBZ 37.27 30.14 600 8.13 8.73 245
ET-P660250BBZ 37.47 30.34 600 8.24 8.76 250
ET-P660255BBZ 37.54 30.91 600 8.25 8.82 255
ET-P660260BBZ 38.09 31.48 600 8.26 8.84 260
ET-P660265BBZ 38.59 32.01 600 8.28 8.85 265
ET-P660200BB 36.00 28.75 600 7.70 7.71 200 15
ET-P660205BB 36.00 28.75 600 7.13 7.80 205
ET-P660210BB 36.00 28.75 600 7.3 7.99 210
ET-P660215BB 36.00 29.00 600 7.41 8.10 215
ET-P660220BB 36.30 29.00 600 7.58 8.10 220
ET-P660225BB 36.68 29.58 600 7.61 8.25 225
ET-P660230BB 36.75 29.64 600 7.76 8.33 230
ET-P660235BB 37.08 29.83 600 7.88 8.50 235
ET-P660240BB 37.17 29.96 600 8.02 8.58 240
ET-P660245BB 37.27 30.14 600 8.13 8.73 245
ET-P660250BB 37.47 30.34 600 8.24 8.76 250
ET-P660255BB 37.54 30.91 600 8.25 8.82 255
ET-P660260BB 38.09 31.48 600 8.26 8.84 260
ET-P660265BB 38.59 32.01 600 8.28 8.85 265
ET-P672230BB 43.56 34.20 600 6.75 7.32 230 15A
ET-P672235BB 43.56 34.20 600 6.87 7.45 235
ET-P672240BB 43.85 34.95 600 6.88 7.63 240
ET-P672245BB 43.85 34.95 600 7.01 7.70 245
ET-P672250BB 43.88 35.20 600 7.12 7.81 250
ET-P672255BB 43.88 35.20 600 7.24 7.85 255
ET-P672260BB 43.49 34.80 600 7.47 8.18 260
ET-P672265BB 43.63 36.40 600 7.28 7.90 265

17
www.etsolar.com
ET-P672270BB 44.16 35.48 600 7.61 8.21 270 15A
ET-P672275BB 44.18 35.52 600 7.75 8.26 275
ET-P672280BB 44.27 35.54 600 7.88 8.48 280
ET-P672285BB 44.72 35.86 600 7.95 8.55 285
ET-P672290BB 44.75 35.92 600 8.08 8.62 290
ET-P672295BB 44.78 36.17 600 8.16 8.68 295
ET-P672300BB 44.89 36.68 600 8.18 8.72 300
ET-P672305BB 45.12 37.18 600 8.21 8.78 305
ET-P672310BB 45.80 37.71 600 8.23 8.79 310
ET-P672315BB 46.43 38.23 600 8.24 8.81 315
ET-P672320BB 46.51 38.79 600 8.25 8.82 320

Usually the load of the modules is a group of batteries. To prevent the modules from
being charged by batteries under the circumstance of no sunlight, it is important to add a
shut-off diode in series. Also, please consider the voltage decrease of PN junction of
about 0.7V when connecting the shut-off diode. The modules can withstand for a
maximum positive or negative design loading of 45 lbs / ft2.

The environmental temperature may also affect the modules’ output power. If the
environmental temperature goes up, the short-circuit current will increase a little, while
open-circuit voltage will decrease, which will result in a decrease in the module’s output
power. Therefore, a lower environmental temperature is most appropriate for the module.

5. Operation and Maintenance


ET Solar module users should rinse the array seasonally or as needed in dry, dirty areas
to improve the performance of their solar electrical systems. Heavily soiled modules will
have a decrease in performance due to reduced light on the photovoltaic cells. Studies by
the PVUSA in Davis, CA estimate that during a dry year module soiling may affect
performance by as much as 7% annually with no cleaning. Seasonal rains often clean the
modules, however, during the long dry summer, it is helpful to rinse the modules as
needed.
ET solar modules may be rinsed with clean water to remove dirt. Normal pressure from a
standard residential hose and nozzle is recommended. Early morning and late afternoons
are favorable times to clean to avoid a sudden change in temperature. Care must be taken
since modules produce energy any time light is present. Modules are not to be touched or
walked on except by a licensed professional.

18
www.etsolar.com
Disclaimer of liability

Because the use of this manual and the conditions or methods of installation, operation, use
and maintenance of photovoltaic products are beyond ET Solar's control, ET Solar does not
accept responsibility and expressly disclaims liability for loss, damage, or expense arising
out of or in any way connected with such installation, operation, use or maintenance. No
responsibility is assumed by ET Solar for any infringement of patents or other rights of third
parties, which may result from use of the PV product. No license is granted by implication or
otherwise under any patent or patent rights.

The information in this manual is based on ET Solar's knowledge and experience and is
believed to be reliable, but such information including product specification (without
limitations) and suggestions does not constitute a warranty, expressed or implied. ET Solar
reserves the right to change the manual, the product, the specifications, or product
information sheets without prior notice.

Contact information of manufacturer:

ET Solar Group Limited


24F, A2 World Trade Center Mansion,
67 Shanxi RD, Nanjing 210009, China
Tel: 86 25 86898096 86898098
Fax: 86 25 86898097
E-mail: [email protected]
www.etsolar.com

You may contact our regional branches for questions and services:

ET Solar Europe (Europe),


Munich City Tower Landsbergerstr. 110-114, 9 Fl. D-80339
Munich, Germany
Tel: +49 89 5009405-0
Fax: +49 89 5009405-99
:Sales @etsolar.de
Email:
ET Solar USA (America & Canada )
4900 Hopyard Road, Suite 290, Pleasanton, CA 94588, USA
Tel: +1 925 4609 898
Fax: +1 925 4609 929
Email: sales @etsolar.us

19
www.etsolar.com
Please consult your dealer or the manufacturer concerning the warranty of your
modules. 2010 © ET Solar Group.

20

You might also like