0% found this document useful (0 votes)
81 views2 pages

Datasheet MultiPlus II Inverter Charger en

The MultiPlus-II is an inverter/charger that provides AC power even during grid failures and can boost generator or grid capacity. It has two AC outputs, with one continuing to power loads during outages. The MultiPlus-II can operate in parallel configurations to achieve high power outputs and is compatible with solar energy systems. It has monitoring and control options including remote access via internet.

Uploaded by

nigelkdx200
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views2 pages

Datasheet MultiPlus II Inverter Charger en

The MultiPlus-II is an inverter/charger that provides AC power even during grid failures and can boost generator or grid capacity. It has two AC outputs, with one continuing to power loads during outages. The MultiPlus-II can operate in parallel configurations to achieve high power outputs and is compatible with solar energy systems. It has monitoring and control options including remote access via internet.

Uploaded by

nigelkdx200
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MultiPlus-II Inverter/Charger Victron online product page

230 V \ https://ve3.nl/6H

A MultiPlus, plus ESS (Energy Storage System) functionality


The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external
current sensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.
PowerControl and PowerAssist - Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use
whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl
function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a
limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.
When the load reduces, the spare power is used to recharge the battery.
Solar energy: AC power available even during a grid failure
The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is
compatible with both solar charger controllers and grid-tie inverters.
Two AC Outputs
The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of
a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that
computers and other electronic equipment will continue to operate without disruption.
The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the
battery, like a water heater for example, can be connected to this output.
Virtually unlimited power thanks to parallel (not for the 8k, 10k and 15k models) and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.
On-site system configuring, monitoring and control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface
needed).
Several monitoring and control options are available: Cerbo GX, Color Control GX, Venus GX, Octo GX, CANvu GX, laptop,
computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring and monitoring
Install a Cerbo GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.

Standard marine, mobile or off-grid application Grid parallel topology with MPPT solar charge controller
Loads that should shut down when AC input power is not available can The MultiPlus-II will use data from the external AC current sensor
be connected to a second output (not shown). These loads will be taken (must be ordered separately) or power meter to optimise self-
into account by the PowerControl and PowerAssist function in order to consumption and, if required, to prevent grid feed. In case of a power
limit AC input current to a safe value when AC power is available. outage, the MultiPlus-II will continue to supply the critical loads
12/3000/120-32
24/5000/120-50 48/8000/ 48/10000/ 48/15000/
MultiPlus-II 230V 24/3000/70-32
48/5000/70-50 110-100 140-100 200-100
48/3000/35-32
PowerControl & PowerAssist Yes
Transfer switch 32 A 50 A 100 A 100 A 100 A
Maximum AC input current 32 A 50 A 100 A 100 A 100 A
INVERTER
DC Input voltage range 12V - 9,5–17 V 24V - 19–33V 48V – 38-66 V
Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25°C (3) 3000 VA 5000 VA 8000 VA 10000 VA 15000 VA
Cont. output power at 25°C 2400 W 4000 W 6400 W 8000 W 12000 W
Cont. output power at 40°C 2200 W 3700 W 5500 W 7000 W 10000 W
GX Touch and Cerbo GX Cont. output power at 65°C 1700 W 3000 W 4000 W 6000 W 7000 W
Provides intuitive system control and monitoring Max apparent feed-in power 3000 VA 5000 VA 8000 VA 10000 VA 15000 VA
Besides system monitoring and control the Cerbo Peak power 5500 W 9000 W 15000 W 18000 W 27000 W
GX enables access to our free remote monitoring Maximum efficiency 93%/94%/95% 96% 95% 96% 95%
website: the VRM Online Portal Zero load power 13 / 13 / 11 W 18 W 29 W 38 W 55 W
Zero load power in AES mode 9/9/7W 12 W 19 W 27 W 39 W
Zero load power in Search mode 3/3/2W 2W 3W 4W 6W
CHARGER
Input voltage range: 187-265 VAC
AC Input
Input frequency: 45 – 65 Hz
Charge voltage 'absorption' 14,4 / 28,8 / 57,6 V
Charge voltage 'float' 13,8 / 27,6 / 55,2 V
Storage mode 13,2 / 26,4 / 52,8 V
Max. battery charge current (4) 120 /70 / 35 A 120 / 70 A 110 A 140 A 200 A
Battery temperature sensor Yes
GENERAL
Auxiliary output Yes (32A) Yes (50A)
External AC current sensor (optional) 50A or 100A
Programmable relay (5) Yes
Protection (2) a–g
VRM Portal For parallel (not for 8k, 10k and 15k models) and three phase operation,
Our free remote monitoring website (VRM) will VE.Bus communication port remote monitoring and system integration
display all your system data in a comprehensive General purpose com. port Yes, 2x
graphical format. System settings can be changed Remote on-off Yes
remotely via the portal. Alarms can be received by e- Operating temperature range -40 to +65°C (fan assisted cooling)
mail. Humidity (non-condensing) max 95%
ENCLOSURE
Material & Colour Steel, blue RAL 5012
Protection category IP22
Four M8 bolts
Battery-connection M8 bolts
(2 plus and 2 minus connections)
230 V AC-connection Screw terminals 13 mm² (6 AWG) Bolts M6 Bolts M6 Bolts M6
Weight 19 kg 30 kg 42 kg 49 kg 80 kg
546 x 275 x 147
607 x 330 x 149 642 x 363 x 677 x 363 x 810 x 405 x
Dimensions (hxwxd) mm 499 x 268 x 141
565 x 320 x 149 206 206 217
499 x 268 x 141
STANDARDS
EN-IEC 60335-1, EN-IEC 60335-2-29,
Safety
EN-IEC 62109-1, EN-IEC 62109-2
EN 55014-1, EN 55014-2
Emission, Immunity EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Uninterruptible power supply Please consult the certificates on our website.
VRM app Anti-islanding Please consult the certificates on our website.
VE.Bus Smart Dongle
1) Can be adjusted to 60 Hz 3) Non-linear load, crest factor 3:1
Monitor and manage Measures battery 2) Protection key: 4) Up to 25°C ambient
your Victron Energy voltage and a) output short circuit 5) Programmable relay which can be set for general alarm, DC under voltage or genset
system from your smart temperature and allows b) overload start/stop function. AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC
phone and tablet. monitoring and control c) battery voltage too high
Available for both iOS with a smart phone or d) battery voltage too low
and Android. e) temperature too high
other Bluetooth
f) 230 VAC on inverter output
enabled device. g) input voltage ripple too high

Current sensor 100A:50mA Digital Multi Control Panel


To implement PowerControl and A convenient and low-cost solution for remote
PowerAssist and to optimize self- monitoring, with a rotary knob to set
Connection Area MultiPlus-II 3k consumption with external current sensing. PowerControl and PowerAssist levels.
Maximum current: 50A resp. 100A.
Length of connection cable: 1 m.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands