XG-X2000 Series: Controller Instruction Manual
XG-X2000 Series: Controller Instruction Manual
*96M14564-2*
Introduction
This manual describes the hardware information. Read this manual
thoroughly to understand how the XG-X2000 Series works in order to
Customizable Vision System maximize the performance of the system.
• This manual is for the XG-X2000 Series. All references however,
XG-X2000 Series unless otherwise noted, pertain to the XG-X2700/2702. For more
details about the differences between the models, see "Main
Specifications" (page 12) and the "XG-X2000 Series User's Manual".
Controller Instruction Manual • Always keep this manual in a safe location for future reference.
• Please ensure that the manual is passed to the end user of the controller.
Read this manual thoroughly before using the XG-X2000 Series.
Always keep this manual in a safe place for future reference.
Symbols
The following warning symbols are used to ensure safety and to prevent
human injury and/or damage to property when using the system.
Trademarks
• “SD Memory Card” is a registered trademark of the SD association.
• EtherCAT® is a patented technology and registered trademark
licensed by Beckhoff Automation GmbH, Germany.
• Other company names and product names are registered trademarks
or trademarks of their respective companies.The TM mark and ® mark
are omitted in this manual.
Software information
This product incorporates the software files developed independently by or
for Keyence Corporation, software files owned and licensed by a third party,
and software files subject to certain open source license agreements.
• The open source software files are subject to the notices and
additional terms and conditions. For information about such open
source software files, please refer to the “License Information” in the
“System Information” menu option under “Global”.
• Such open source software files are provided on an “AS IS” basis to
the maximum extent permitted by applicable law.
• If there is any discrepancy between the terms and conditions of the
applicable open source license agreement and the “License”, the
terms and conditions of the applicable open source license agreement
prevail with respect to the applicable open source software.
• You may obtain a copy of the source code corresponding to the
binaries for GPL/LGPL-licensed file by sending a request to Keyence
customer service at “[email protected] ”. There will be a
charge to cover the costs of providing the source code.
1
Measures to be taken when an abnormality occurs
Package Contents
In the following cases, turn the power OFF immediately. Using
The equipment and accessories listed below are included in the the unit in an abnormal condition may cause fire, electric
shock, or product malfunction. Contact your local Keyence
package when shipped. After opening the carton, check that you have CAUTION office for repair.
received all of the equipment and accessories listed below. • If water or debris enters the system
• If the system is dropped or the case is damaged
• If smoke or a burning smell emits from the controller
Standard Package
• Controller Unit × 1
Usage
(XG-X2000/2002/2200/2202/2500/2502/ • Before making any connections/disconnections, be sure to
2700/2702/2800/2802/2800LJ/2900/ turn off the power of this unit and connected devices.
2902) Failure to do so may result in a malfunction of the controller
or connected devices.
• SD Card • Do not turn the power off while you are programming.
(OP-87133(512MB): XG-X2000/2002/ Otherwise, all or part of the program settings may be lost.
2200/2202 NOTICE • Do not block the ventilation holes. Otherwise, the inside
CA-SD1G(1GB): temperature may rise and a malfunction may occur.
• Do not allow an excessive amount of sunlight or bright
XG-X2500/2502/2700/2702/2800/2802/ indoor light to enter the camera for a long period of time.
2800LJ) × 1 Doing so may cause damage to the image capture surface
CA-SD4G(4GB): XG-X2900/2902 inside the camera.
(pre-installed in SD1 slot)
• Terminal block sticker package ×1 Maintenance
• Controller instruction manual × 1 • Do not clean with benzene, thinner, or alcohol. Doing so
may cause discoloration or deformation of the unit.
NOTICE • If the unit has any dirt on it, wipe it off with a cloth moistened
with a mild detergent, then wipe with a dry cloth.
2
Warning labels
Safety precautions on laser product
The contents of warning indications and locations for attaching warning
The LJ-V7000 series head laser classes which are to be connected to labels are described below.
the CA-E100LJ/110LJ are classified as per the following. The IEC (English) warning labels are attached to the unit when shipped
LJ-V7020K/ LJ-V7020/ LJ-V7060K/ LJ-V7060/ LJ-V7080/ LJ-V7200/ LJ-V7300/
from the factory. Use the suitable warning label included in the package
Models LJ-V7020KB LJ-V7020B LJ-V7060KB LJ-V7060B LJ-V7080B LJ-V7200B LJ-V7300B of this product according to the countries and/or regions where this
Wavelength 405nm product is used. In this case, it can be affixed on the IEC (English)
IEC60825-1, Output 10mW 10mW 4.8mW 10mW 4.8mW 4.8mW 4.8mW warning label, which has already been affixed to this product.
FDA(CDRH) Laser
Class 2M Class 2M Class 2 Class 2M Class 2 Class 2 Class 2
Part 1040.10 * class • Warning label display content
* The laser classification for FDA(CDRH) is implemented based on IEC60825-1 LJ-V7060K/LJ-V7060KB/LJ-V7080/LJ-V7080B/LJ-V7200/
in accordance with the requirements of Laser Notice No. 50. LJ-V7200B/LJ-V7300/LJ-V7300B
IEC (English) DIN (German) CEI (French) CEI (Italian)
• Use of controls or adjustments or performance of
procedures other than those specified herein may result in
hazardous radiation exposure.
Follow the instructions mentioned in this manual. Otherwise,
injury to the human body (eyes and skin) may result.
Precautions on Class 2M Laser Product JIS (Japanese) GB (Simplified Chinese) IEC (Traditional Chinese)
- Do not stare into the direct or specularly reflected beam.
- Do not direct the beam at other people or into areas where
other people might be present.
- Be careful of the path of the laser beam. If there is a
possibility that the operator may be exposed to the
specular or diffuse reflections, block the beam by
installing a protective enclosure.
- Install this product so that the path of the laser beam is not
LJ-V7020/LJ-V7020B/LJ-V7020K/LJ-V7020KB/LJ-V7060/
as the same height as that of human eye. LJ-V7060B
- Do not direct the beam into an area where telescopic IEC (English) DIN (German) CEI (French) CEI (Italian)
WARNING optical instruments (for example, telescopes and
binoculars) are likely to be used. Viewing the laser output
with the telescopic optical instruments may pose an eye
hazard.
Precautions on Class 2 Laser Product
- Do not stare into the direct or specularly reflected beam. JIS (Japanese) GB (Simplified Chinese) IEC (Traditional Chinese)
- Do not direct the beam at people or into areas where
people might be present.
- Be careful of the path of the laser beam. If there is a
possibility that the operator may be exposed to the
specular or diffuse reflections, block the beam by
installing a protective enclosure.
- Install this product so that the path of the laser beam is not
as the same height as that of human eye. • Warning label attachment positions
• Do not disassemble this product. Laser emission from this LJ-V7020/LJ-V7020B
product is not automatically stopped when it is
disassembled.
LJ-V7020K/LJ-V7020KB
LJ-V7060/LJ-V7060B
LJ-V7060K/LJ-V7060KB
LJ-V7080/LJ-V7080B
LJ-V7200/LJ-V7200B
LJ-V7300/LJ-V7300B
3
(6) SD2 slot (upper), SD1 slot (lower)
Identifying Controls and Connectors Insert an SD card.
The accessory SD card (CA-SD4G: 4 GB, CA-SD1G: 1 GB, or OP-
XG-X2000/2002/2200/2202/2500/2502/2700/2702 87133: 512 MB) is inserted as SD card 1 in the lower slot (SD1).
(1)
(2) Point SD Card 1 must be inserted while the device is operating.
(3)
(4) (7) RS-232C port
(5) Use to connect an optional RS-232C communication cable (OP-26487: 2.5 m)
(6)
(7) or an optional RS-232C modular cable for touch panels (OP-87264: 3 m/
OP-87265: 10 m).
(8) By default, RS-232C port 1 is used for data output and
Reference command control. For details about how to change the setting,
(9)
see the XG-X2000 Series User's Manual.
(10)
(11) (8) MONITOR (RGB output) terminal
Use to connect to an external monitor.
(12)
The unit’s power GND (0V) is shared in common with the
(13) connector seals and signal GND.
If there is a potential difference with the connection for the
(14) NOTICE external monitor, this may result in breakdowns or malfunctions
(15) of the unit and the connected external monitor.
(16) (Recommended monitors: CA-MP120/CA-MP120T)
XG-X2800/2802/2900/2902+CA-E100 Point The unit’s monitor output is XGA (1024 × 768 pixels). If commercial
analog RGB monitors other than XGA monitors are used, the display
quality may worsen depending on the monitor’s specifications, and
images may not properly be displayed.
4
(18) ENCODER 1/3 (Encoder signal 1/3 connection) connector Be careful in regard to cooling the unit in the installation site
Connects (supplies 5 V out) the encoder signal 1/3 (RS-422 or open collector).
• For ventilation, keep the space free of objects for 50 mm or more
The ENCODER No. allocations (1 - 4) are determined by the above the controller and 50 mm or more for both sides. Keep the
Reference installation positions to the CA-E100L/200L controller.
ENCODER 1/ENCODER 2 are allocated to the units which are
space free of objects for 90 mm or more in the front of the connector
directly connected to the controller, and other cameras that panel in order to connect the cables safely.
include CA-E100L/200L. • If the controller units are to be installed in rows, make sure that there
ENCODER 3/ENCODER 4 are allocated to the units which they
are spaces of 50 mm or more between the controllers, and spaces of
are connected to that sandwich the input units.
50 mm or more above them.
(19) LJ-V HEAD B (LJ-V series head B connection) connector If spaces of 50 mm or more are ensured of even on the underside
orientations of DIN rail mounts, etc., then the units can be used at
Use to connect to the LJ-V series head B.
higher than rated temperatures.
(20) LJ-V HEAD A (LJ-V series head A connection) connector
Use to connect to the LJ-V series head A
Don't connect any device except LJ-V series head. Otherwise 50mm 50mm
NOTICE it may cause a malfunction.
Installing the Controller Unit • Do not block the ventilation openings on the top and bottom
of the controller. If the vents are blocked, heat will accumulate
Install the controller unit to DIN rail, or use the holes on the bottom of the inside the controller and can cause a system failure.
• If the temperature inside the control panel (temperature at
controller to secure it with screws. the bottom of the controller) exceeds the rating, use forced
air-cooling or increase the free space around the system to
• Do not install the controller in a location with lots of dust or improve ventilation until the operating ambient temperature
water vapor. decreases below the rating.
The controller does not have a mechanism to protect it from • When the temperature gets high inside the controller unit,
dust or water. Dust or water entering the controller can the unit may display abnormal heat generation alerts such
cause damage to the controller. NOTICE as the following. (1) Warning: you are being notified that it is
• Turn off the power to the controller when connecting or likely that operations may be terminated due to high
removing an expansion unit, a cable, or a terminal block. temperatures, (2) Operations terminated: since it is likely
NOTICE Connecting or removing the camera expansion unit, the that thermal runaway and damage to the unit are being
cable, or the terminal block while the power is being generated, and as the unit is in an error state, operations
supplied may damage the controller or peripheral devices. are terminated.
• When an expansion unit is not connected, place the If these alerts are displayed, quickly implement
connector protection cover back on the controller. Using the countermeasures such as lowering the ambient temperature
controller with the connector exposed may cause damage to the rated temperature or lower and cooling the controller
to the controller. main unit.
• Some of the model in the XG-X2000 series are factory equipped with fan
Caution on Direction of Controller Mounting
units (CAF100) on their left sides. Since the fan units can be detached
• Install the controller in the direction indicated by the circle shown and replaced for maintenance, the units cannot be operated with them
below. Do not install the controller in any other direction. detached.
5
Installing the Communication Expansion Unit Installing the Controller
If you use the CC-Link interface
or the EtherCAT interface, use a NOTICE Mount the controller in a stable location that is free from vibration.
communication expansion unit
sold separately (CC-Link: CA-
Installing the Controller on a DIN Rail
NCL20E/EtherCAT: CA-NEC20E).
The controller and the expansion unit are
Remove the protective cover from
designed to be mounted on a DIN rail.
connector 2 on the right side of
Pull the tab on the bottom in the direction of
the controller and install the
the arrow to mount or dismount the controller.
communication expansion unit as
shown on the right.
When Using the Camera Input Unit, Illumination Expansion Unit Connecting the Camera Cables
and Communication Expansion Unit Together Connect the camera to the camera connector of the controller unit using
Mount the camera input unit directly to the controller, then mount the one of the optional camera cables.
illumination expansion unit and communication expansion unit to the If connecting only a single camera, attach it to the CAM1 connector.
right side of the camera input unit.
If connecting only a
Camera 2 Camera1 single camera, attach it
Camera input unit to the camera 1 connector.
6
Using the repeater for camera cable extension
The camera cable can be extended by using the extension repeater for Parallel I/O Interface
the camera cable (excluding the LJ-V Series head, and high-speed line
scan camera). Connector Specifications
For more information on connection, read the instructions provided with The specifications of the
the camera extension repeater. parallel I/O connector for
(1) (21)
the controller are as follows.
Connector
FX2B-40SA-1.27R
Camera cable (20) (40)
(Hirose Electric)
extension
repeater
Color flat cable
UL20028-FRX-CF-40 (Fujikura, equivalent wire gauge AWG28)
In normal situations, use the specialized parallel connection
Reference cable (3 m) OP-51657 (option).
Connecting the 24 VDC Power Source Pin layout: The cable color when the OP-51657 (option)
is used.
• Use electrical wiring AWG14 to AWG22.
• Make sure to connect the frame ground terminal for the 24 *1 It is the default assigned value on the terminal where the
VDC power source to a type D ground. Reference signal assignment can be changed. These assignments
• The sizes of solderless connectors are shown below. Use may vary if the Global settings have been changed.
connectors that fit M3 screws. *2 For more details about the signal description, see the
NOTICE Ring lug terminal Spade lug terminal
"XG-X2000 Series Communications Control Manual".
5.8 mm or less 5.8 mm or less No. Terminal Terminal explanation Assigned default state*1 Circuit color
name Variable function*2 Bit diagram
• Tighten the screws with a torque of 0.5 to 0.75 Nm. 1 COMIN2 Connector input common - - B Brown
2 IN0 General purpose input 0 0 B Red
3 IN1 General purpose input 1 1 B Orange
7
Pin layout
Terminal Block Interface
*1 It is the default assigned value on the terminal where the
Reference signal assignment can be changed. These assignments
Standard Specifications may vary if the Global settings have been changed.
*2 For more details about the signal description, see the "XG-
Terminal block specifications for the controller are as follows. X2000 Series Communications Control Manual".
High-speed general
4 F_OUT3(RUN) Run mode output 0 C
purpose output 3
COMOUT Common for terminal block
5 - - -
IN connector (COMOUT) outputs
• Suitable wiring High-speed general
6 F_OUT0(FLS1) Strobe light output 1 0 C
purpose output 0
AWG 16 - 28 (1) High-speed general
7 F_OUT1(FLS2) Strobe light output 2 0 C
• Terminal block screw torque purpose output 1
0.25 Nm or less 8 N.C - - - -
(6) common for high-speed
COMOUT_F
9 general purpose output - - -
(COMF)
terminals
( ) indicates labels printed on terminal blocks at time of shipment
(5)
8
ENCODER connector
When connecting LJ-V input unit CA-E100LJ/110LJ (sold separately) Input/Output Circuit
Circuit
No. Terminal name Terminal explanation
diagram Input Circuit
1 OC A 24(24V) Open collector Encoder input A (24V) F
2 OC A 12(12V) Open collector Encoder input A (12V) F Input circuit diagram
3 OC A 5(5V) Open collector Encoder input A (5V) F
4 422 A+(+) RS-422 Encoder input A+ F
Circuit A (F_IN0 to 3 only, EV compatible)
5
ENC A COM
Encoder input A common (-) F
• Max. imposed voltage: 26.4 V
(COM(-))
• ON voltage: 19 V or greater 7.5kΩ
6 OC B 24(24V) Open collector Encoder input B (24V) F IN
7 OC B 12(12V) Open collector Encoder input B (12V) F • ON current: 3 mA or greater
8 OC B 5(5V) Open collector Encoder input B (5V) F • OFF voltage: 5 V or less 910Ω
9 422 B+(+) RS-422 Encoder input B+ F • OFF current: 1 mA or less
ENC B COM COMIN*
10 Encoder input B common (-) F
(COM(-))
11 OC Z 24(24V) Open collector Encoder input Z (24V) F
12 OC Z 12(12V) Open collector Encoder input Z (12V) F
13 OC Z 5(5V) Open collector Encoder input Z (5V) F
Circuit B (other inputs)
14 422 Z+(+) RS-422 Encoder input Z+ F
ENC Z COM • Max. imposed voltage: 26.4 V
15 Encoder input Z common (-) F
(COM(-)) • ON voltage: 19 V or greater 15kΩ
• Use a shield cable that supports an RS-422 signal for the • ON current: 3 mA or greater IN
Reference connection, and always connect the Cable shield to the FG.
• There is continuity between each input circuit. Pay attention
• OFF voltage: 5 V or less 2.7kΩ
so that potential differences are not generated between the • OFF current: 1 mA or less
signals. COMIN*
• The ENC A COM, ENC B COM, ENC Z COM, 0V OUT and
REMOTE COM are respectively insulated with the controller
and the other expansion unit commons.
Example of connections :
I/O connector When connecting a NPN PLC output to the system input
When connecting LJ-V input unit CA-E100LJ/110LJ (sold separately)
Circuit OUT IN
No. Terminal name Terminal explanation
diagram
1 5V OUT(5V OUT) Encoder service power supply -
2 0V OUT(0V OUT) (150mA MAX) -
3 N.C - -
4 RMT COM(COM) Laser remote interlock input common G COM(-) COMIN*
5 REMOTE(RMT) Laser remote interlock input G
( ) indicates labels printed on terminal blocks at time of shipment PLC (NPN output) Input circuit on controller
• The rated output for the 5 V OUT is 150 mA. When using
Reference encoders which are going to exceed that, prepare an Example of connections :
external 5 V power supply. When connecting a PNP output to the controller input
• The laser remote interlock inputs are non-voltage inputs.
The laser emits from the LJ-V sensor head which is
connected to CA-E100LJ/110LJ via a short-circuit with the
IN
input commons, if it is open the emissions terminate (factory
default is that it is short-circuited via a shorting pin).
• The ENC A COM, ENC B COM, ENC Z COM, 0V OUT and
REMOTE COM are respectively insulated with the controller
COM(+)
and the other expansion unit commons.
COMIN*
OUT
Output Circuit
Output circuit diagram
Circuit C (share in common all output terminals)
• Max. imposed
voltage: 30 V Poly Switch
• Leakage current: OUT
50 mA
• Leakage current:
0.1 mA or less
• Residual voltage: COMOUT
1.4 V or less (50 mA)
1.0 V or less (20 mA)
Point Since this instrument utilizes a photo MOSFET in the output elements,
any one of the NPN inputs, or PNP inputs is connectable.
9
Connection example:
when connecting this instrument’s outputs via a positive common Encoder Input/Output Circuit
Point If the input instrument is compatible with the NPN open collector
outputs, then refer to this connection example. CA-E100L/200L 422A/B/Z
• When connecting a output from the controller to a PLC with a positive Input circuit diagram
common
Circuit D
IN
• Equivalent AM26LS32
Poly Switch 5V Poly Switch 5V CA-E100L/200L
OUT
OUT
27kΩ
A+, B+, Z+ 1kΩ
Receiving
circuit
COMOUT* A-, B-, Z- Equivalent
1kΩ
AM26LS32
27kΩ
GND
COM(+)
Main circuit
Load A+, B+, Z+
Receiving
OUT
circuit
A-, B-, Z- Use shield cable.
26C31 0V A-, B-, Z- Equivalent
AM26LS32
(Shield)
COMOUT* GND
If the input instrument is compatible with the PNP open collector • ON current: 3 mA or greater
Point 3kΩ
outputs, then refer to this connection example. • OFF voltage: 3.6 V or less OC_A, B, Z
Poly Switch
COM(-)
Connection example:
COMOUT*
when connecting the PNP open collector output encoder
A phase/ Shielded
B phase/ twisted pair cable
Z phase OC_A,B,Z
Relay Input circuit on controller
OUT
10
The open collector encoder inputs of the CA-E100L/200L are
Reference only compatible with 24 V type encoders. Laser Remote Interlock Input Circuit
CA-E100LJ/110LJ ENCODER Connector CA-E100LJ/110LJ REMOTE
Input circuit diagram Input circuit diagram
Circuit F Circuit G
Input specifications for the open collector encoder inputs (DC24V/ • Non-voltage input +5V +5V
DC12V/DC5V) • ON voltage: 1V or less
• Max. imposed voltage: 1kΩ • ON current: 0.6 mA or less
2.2kΩ
1kΩ
OC 24
26.4V/13.2V/5.5V OC 12
910kΩ
• Short-circuit current (Typ.):
100kΩ
• ON voltage: OC 5
Internal circuit
422 +
120kΩ 2 mA REMOTE
21.6 V or greater/ Poly Switch Internal
circuit
10.8 V or greater/ ENC COM
Poly Switch
3.5V or greater
• ON current: 5 mA or greater RMT COM
Poly Switch
• OFF voltage:
3.6 V or less/2.4 V or less/1.0 V or less Connection example:
Input specifications for the RS-422 Encoder inputs when connecting the NPN open collector output PLC
• Equivalent AM26LS32
+5V +5V
Connection example:
when connecting the NPN open collector output encoder
Shielded OUT REMOTE
Internal circuit
NPN Open collector twisted pair cable OC 24
output on Encoder 12V *
OC 12
OC 5
422 + Internal
Poly Switch
OUT circuit
COM(-) RMT COM
A phase/ Poly Switch
ENC Poly Switch
B phase/ COM PLC Input circuit on CA-E100L/110LJ
Z phase Input circuit on CA-E100L/110LJ
COM(-) (NPN output)
* 12 V was used for this example. Match 5V/12V/24V in accordance with the power supply.
Connection example:
Connection example: when connecting the PNP open collector output PLC
when connecting the PNP open collector output encoder +5V +5V
Shielded
PNP Open collector twisted pair cable OC 24
output on Encoder
OC 12
OC 5 COM(+) REMOTE
Internal circuit
422 + Poly Switch Internal
COM(+) 12V * circuit
ENC Poly Switch
COM
OUT Input circuit on CA-E100L/110LJ
* 12 V was used for this example. Match 5V/12V/24V in accordance with the power supply. OUT RMT COM
Poly Switch
PLC Input circuit on CA-E100L/110LJ
(PNP output)
Connection example:
when connecting the RS-422 output encoder
RS-422 output OC 24
on Encoder Shielded
A phase/
B phase/ twisted pair cable OC 12
Z phase + OC 5
422 + Poly Switch Internal
circuit
A phase/ ENC Poly Switch
B phase/ COM
Z phase - Input circuit on CA-E100L/110LJ
11
Main Specifications
Model type XG-X2700/2702 XG-X2500/2502 XG-X2200/2202 XG-X2000/2002
2 color/monochrome cameras
Camera input A maximum of up to four are connectable by connecting one optional area camera input unit CA-E100
Trigger input Simultaneous capture by up to 4 cameras/individual capture can be selected. (when CA-E100 is not connected, up to 2 cameras can be connected simultaneously)
• With XG-035C/S035C/H035C/035M/S035M/H035M connected
310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx. 240,000 pixels
• With CA-HX048C/HX048M connected
470 k pixel mode: 784(H) x 596(V), approx. 470,000 pixels
310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx. 240,000 pixels
• With XG-200C/S200C/H200C/200M/S200M/H200M connected
2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
1 mega-pixel mode: 1024(H) x 960(V), approx. 980,000 pixels
• With CA-HX200C/HX200M connected
2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
Supported cameras / Number of pixels
• With XG-H500C/H500M connected
5 mega-pixel mode: 2432(H) x 2050(V), approx. 4.99 mega-pixels
• With CA-HX500C/HX500M connected
5 mega-pixel mode: 2432(H) x 2050(V), approx. 4.96 mega-pixels
2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
• With CA-H2100C/H2100M connected
21 mega-pixel mode:
5104(H)x4092(V),
approx. 20.89 mega-pixels
5 mega-pixel mode:
2432(H)x2050(V),
approx. 4.99 mega-pixel
Main image processor DSP (High-speed) DSP
Registered number of inspection settings SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD card and the size of the programs), external switching possible
Number of registered screens Maximum 1000 screens for each program (depending on SD card size), Image compression.
• SD card slot x 2 • SD card slot x 2
SD card • Compatible with OP-87133 (512MB), CA-SD1G (1GB: installed • Compatible with OP-87133 (512MB: installed standard to SD1),
standard to SD1), CA-SD4G (4GB) and CA-SD16G (16GB) CA-SD1G (1GB), CA-SD4G (4GB) and CA-SD16G (16GB)
Controlled input (compatible • 20 input (including four high speed inputs designed for trigger input)
with arbitrary assignment) • Input rating 26.4 V or lower, 2 mA or greater (3 mA or greater for high speed input terminal)
Controlled output (compatible • 28 output (including four high speed outputs designed for FLASH outputting linked to external device)
with arbitrary assignment) • Photo MOSFET *1 Maximum 50 mA (30 V or less)
Monitor output Analog RGB Output, XGA (1024 x 768, 24 bit color)
Operation indicators LED display for Power ON and ERROR
• Can perform numerical value output, control input/output, and switching the functions of CA series touch panel interface (Cannot be used with
RS-232C PLC-Links using the RS-232C port)
• Supports a max. baud rate of up to 230400 bps
• Can output numerical values and perform control input/output using the Ethernet or RS-232C port (Cannot be used in conjunction with CC-Link,
EtherNet/IP, PROFINET, and EtherCAT.)
• The following PLCs are supported via link unit:*2
PLC link KEYENCE: KV-7000 Series, KV-5000/3000 Series, KV-1000/700 Series, KV Nano Series
Mitsubishi Electric: MELSEC iQ-R/L/Q Series, MELSEC A Series (RS-232C only), MELSEC iQ-F Series, MELSEC FX Series (RS-232C only)
OMRON: SYSMAC CJ2/CJ1/CS1/CP1 Series, SYSMAC C Series (RS-232C only)
YASKAWA Electric Corporation: MP2000 Series, MP900 Series (RS-232C only)
• Numerical value output, and control input/output enabled.
• By the connection of KEYENCE PC application software, in addition to the function described above, uploading and downloading the inspection
Ethernet settings, simulations, data, including image data can be sent or received.
• For the FTP client function, the VNC server function (for clients other than for PC it will be only for the screen display), and BOOTP function.
• 1000BASE-T/100BASE-TX/10BASE-T
• By the connection of KEYENCE PC application software, in addition to numerical value output and control input/output , uploading and
USB downloading the inspection settings, simulations, data, including image data can be sent or received.
• USB2.0
• By connecting the optional CC-Link expansion unit CA-NCL20E, numerical value input/output and control input/output are enabled. (Do not use to
CC-Link connect to PLC Link, EtherNet/IP, PROFINET, and EtherCAT)
Interface • Compatible to the Ver.1.10 remote device station, Ver.2.00 remote device station
• Numerical value input/output, and control input/output by using the Ethernet port enabled. (Do not use to connect to PLC Link, CC-Link, POFINET, and
EtherCAT)
EtherNet/IP TM • Compatible to the cyclic communication (max.1436 byte), and message communication
• Maximum number of connections 32
• Compatible with the conformance test Version.CT12
• Numerical value input, and control input/output by using the Ethernet port enabled. (Do not use to connect to PLC Link, CC-Link, EtherNet/IP, and
EtherCAT)
PROFINET • Compatible to the cyclic communication (max. 1408 byte)
• Compatible to the aperiodic (recorded data) communication
• Compatible with the Conformance Class A
• By connecting the optional EtherCAT unit CA-NEC20E, numerical value output and control input/output can be performed (Cannot be used in
conjunction with PLC Link, CC-Link, EtherNet/IP, and PROFINET)
• Compatible to the cyclic communication (process data object communication) (input: max. 536 byte/output: max. 532 byte)
EtherCAT • Compatible to the noncyclic communication (mailbox communication)
• Compatible to CoE
• Explicit Device Identification
• Compliant with the conformance test V2.1.0.2
SNTP By connecting to an SNTP server, the date and time of the controller can be automatically adjusted
• By the optional USB Console (OP-87983), various menu can be used
USB Console
• Compatible to the operation assignment settings to the console button
Mouse Possible to control various menus via an optional dedicated mouse (OP-87506)
• Setting operation from the CA Series touch panel used by the RS-232 port is possible (When RS-232C is used, the nonprocedural communication
Touch Panel and PLC-Links that use the RS-232C port cannot be used.)
• For the dedicated touch menu or the operation button
By connecting a HDD (maximum 2 TB) to a proprietary USB port (USB 3.0 and bus powered compatible: rated output 900 mA), various kinds of data
USB HDD
including image data can be output
Display language Japanese/English/Simplified Chinese/Traditional Chinese/German selectable (Choose the default language to be used when turning power ON)
Illumination control By connecting the optional illumination expansion unit CA-DC40E/DC50E/DC60E, the lighting and light intensity of the LED illumination can be controlled.*3
Cooling fan unit CA-F100 is
Cooling fan -
standard equipment
Power source voltage DC24V±10%
Rating
Consumption current 4.3 A 4.1 A 4.0 A
Ambient temperature 0 to +45°C (DIN rail mounted)/0 to +45°C (Bottom mounted)
Environmental resistance
Ambient operating humidity 35 to 85% RH (no condensation)
Weight Approx. 1800 g Approx. 1600 g
*1 Either positive common connecting which is compatible with NPN input instruments, or negative common connecting which is compatible with PNP input instruments is feasible.
*2 Models equipped with the Ethernet port in the CPU unit support Ethernet port direct connection.
*3 Connect up to 8 illumination expansion units (note that the eight units can include only a maximum two CA-DC50E or CA-DC60E units or one each).
12
Model type XG-X2900/2902 XG-X2800/2802 XG-X2800LJ
• With area camera input unit CA-E100 connected • With LJ-V input unit CA-E100LJ connected
2 color/monochrome cameras per one CA-E100, up to 4 cameras via a maximum of 2 units can be connected Up to 2 identical models of the LJ-V series heads
• With line scan camera input unit CA-E100L connected per one CA-E100LJ can be connected
2 line scan cameras per one CA-E100L, or 2 color/monochrome camerass, up to 4 cameras via
a maximum of 2 units can be connected
• With high-speed line scan camera input unit CA-E200L connected
Camera input*1 Up to 2 high-speed line scan cameras can be connected per one unit of CA-E200L, and up to 4
cameras can be connected when 2 units of CA-E200L are used.
• With 3D camera input unit CA-E100T connected
1 3D camera per one CA-E100T, up to 2 cameras via a maximum of 2 units can be connected
• With LJ-V input unit CA-E100LJ/110LJ connected
Up to 2 identical models of the LJ-V series heads per one CA-E100LJ/CA-E110LJ can be connected
Selection is possible between simultaneous capture by up to 4 cameras and individual capture Up to 2 cameras can be connected
Trigger input
(simultaneous capture by up to 2 cameras is possible with one camera input unit connected). simultaneously
• With XG-035C/S035C/H035C/035M/S035M/H035M connected
310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx. 240,000 pixels
• With CA-HX048C/HX048M connected
470 k pixel mode: 784(H) x 596(V), approx. 470,000 pixels
310 k pixel mode: 640(H) x 480(V), approx. 310,000 pixels
240 k pixel mode: 512(H) x 480(V), approx. 240,000 pixels
• With XG-200C/S200C/H200C/200M/S200M/H200M connected
2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
1 mega-pixel mode: 1024(H) x 960(V), approx. 980,000 pixels
Area camera
• With CA-HX200C/HX200M connected
2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
• With XG-H500C/H500M connected
5 mega-pixel mode: 2432(H) x 2050(V), approx. 4.99 mega-pixels
• With CA-HX500C/HX500M connected
Supported cameras / 5 mega-pixel mode: 2432(H) x 2050(V), approx. 4.99 mega-pixels
Number of pixels 2 mega-pixel mode: 1600(H) x 1200(V), approx. 1.92 mega-pixels
• With CA-H2100C/H2100M connected
21 mega-pixel mode: 5104(H)x4092(V), approx. 20.89 mega-pixels
5 mega-pixel mode: 2432(H)x2050(V), approx. 4.99 mega-pixel
• With XG-HL08M connected 8192(H) x 8192(L), approx. 67.11 mega-pixels
Line scan camera • With XG-HL04M connected 4096(H) x 16384(L), approx. 67.11 mega-pixels
• With XG-HL02M connected 2048(H) x 16384(L), approx. 33.55 mega-pixels
• With CA-HL08MX connected 8192(H) x 8192(L), approx. 67.11 mega-pixels
High-speed line camera • With CA-HL04MX connected 4096(H) x 16384(L), approx. 67.11 mega-pixels
• With CA-HL02MX connected 2048(H) x 16384(L), approx. 33.55 mega-pixels
• With XR-HT40M connected 2048(H) x 2048(V), approx. 4.19 mega-pixels
3D Camera
• With XR-HT15M connected 1408(H) x 1408(V), approx. 1.98 mega-pixels
• With LJ-V7020/7020K/7060/7060K/7080/7200/7300 connected
512(H) x 16384(L), approx. 8.39 mega-pixels
LJ-V Sensor Head*2 1024(H) x 8192(L), approx. 8.39 mega-pixels
2048(H) x 4096(L), approx. 8.39 mega-pixels
Main image processor DSP (High-speed)
Registered number of inspection settings SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD card and the size of the programs), external switching possible
Number of registered screens Maximum 1000 screens for each program (depending on SD card size), Image compression.
• SD card slot x 2 • SD card slot x 2
• Compatible with OP-87133 (512MB), CA- • Compatible with OP-87133 (512MB), CA-SD1G (1GB: installed standard to SD1), CA-SD4G
SD card
SD1G (1GB), CA-SD4G (4GB: installed (4GB) and CA-SD16G (16GB)
standard to SD1) and CA-SD16G (16GB)
Controlled input (compatible • 20 input (including four high speed inputs designed for trigger input)
with arbitrary assignment) • Input rating 26.4 V or lower, 2 mA or greater (3 mA or greater for high speed input terminal)
Controlled output (compatible • 28 output (including four high speed outputs designed for FLASH outputting linked to external device)
with arbitrary assignment) • Photo MOSFET *3 Maximum 50 mA (30 V or less)
• When connecting CA-E100L/200L, 2 systems per 1 unit, up to 4 systems via a maximum of 2 units
• When connecting CA-E100LJ/110LJ, 1 system per 1 unit, up to 2 systems via a maximum of 2 units (up to 1 system via a maximum of 1 unit for XG-X2800LJ)
Encoder input
• RS-422 line scan output (5 V output supplied: maximum 150 mA, multi-drop compatible in the case of the CA-E100L/200L), combined open
collector output (CA-E100L/200L is for 24 V compatible components)
Monitor output Analog RGB Output, XGA (1024 x 768, 24 bit color)
Operation indicators LED display for Power ON and ERROR
• Can perform numerical value output, control input/output, and switching the functions of CA series touch panel interface (Cannot be used with
RS-232C PLC-Links using the RS-232C port)
• Supports a max. baud rate of up to 230400 bps
• Can output numerical values and perform control input/output using the Ethernet or RS-232C port (Cannot be used in conjunction with CC-Link,
EtherNet/IP and PROFINET.)
• The following PLCs are supported via link unit:*4
PLC link KEYENCE: KV-7000 Series, KV-5000/3000 Series, KV-1000/700 Series, KV Nano Series
Mitsubishi Electric: MELSEC iQ-R/L/Q Series, MELSEC A Series (RS-232C only), MELSEC iQ-F Series, MELSEC FX Series (RS-232C only)
OMRON: SYSMAC CJ2/CJ1/CS1/CP1 Series, SYSMAC C Series (RS-232C only)
YASKAWA Electric Corporation: MP2000 Series, MP900 Series (RS-232C only)
• Numerical value output, and control input/output enabled.
• By the connection of KEYENCE PC application software, in addition to the function described above, uploading and downloading the inspection
Ethernet settings, simulations, data, including image data can be sent or received.
• For the FTP client function, the VNC server function (for clients other than for PC it will be only for the screen display), and BOOTP function.
Interface • 1000BASE-T/100BASE-TX/10BASE-T
• By the connection of KEYENCE PC application software, in addition to numerical value output and control input/output , uploading and
USB downloading the inspection settings, simulations, data, including image data can be sent or received.
• USB2.0
• By connecting the optional CC-Link unit CA-NCL20E, numerical value input/output and control input/output are enabled. (Do not use to connect to
CC-Link PLC Link, EtherNet/IP, PROFINET, and EtherCAT)
• Compatible to the Ver.1.10 remote device station, Ver.2.00 remote device station
• Numerical value input/output, and control input/output by using the Ethernet port enabled. (Do not use to connect to PLC Link, CCC-Link, POFINET, and
EtherCAT)
EtherNet/IP • Compatible to the cyclic communication (max.1436 byte), and message communication
• Maximum number of connections 32
• Compatible with the conformance test Version.CT12
• Numerical value input, and control input/output by using the Ethernet port enabled. (Do not use to connect to PLC Link, CC-Link, EtherNet/IP, and
EtherCAT)
PROFINET • Compatible to the cyclic communication (max. 1408 byte)
• Compatible to the aperiodic (recorded data) communication
• Compatible with the Conformance Class A
• By connecting the optional EtherCAT unit CA-NEC20E, numerical value output and control input/output can be performed (Cannot be used in
conjunction with PLC Link, CC-Link, EtherNet/IP, and PROFINET)
• Compatible to the cyclic communication (process data object communication) (input: max. 536 byte/output: max. 532 byte)
EtherCAT • Compatible to the noncyclic communication (mailbox communication)
• Compatible to CoE
• Explicit Device Identification
• Compliant with the conformance test V2.1.0.2
SNTP By connecting to an SNTP server, the date and time of the controller can be automatically adjusted
13
Model type XG-X2900/2902 XG-X2800/2802 XG-X2800LJ
• By the optional USB Console (OP-87983), various menu can be used
USB Console
• Compatible to the operation assignment settings to the console button
Mouse Possible to control various menus via an optional dedicated mouse (OP-87506)
Interface • Setting operation from the CA Series touch panel used by the RS-232 port is possible (When RS-232C is used, the nonprocedural communication
(Continued) Touch Panel and PLC-Links that use the RS-232C port cannot be used.)
• For the dedicated touch menu or the operation button
By connecting a HDD (maximum 2 TB) to a proprietary USB port (USB 3.0 and bus powered compatible: rated output 900 mA), various kinds of data
USB HDD
including image data can be output
Display language Japanese/English/Simplified Chinese/Traditional Chinese/German selectable (Choose the default language to be used when turning power ON)
By connecting the optional illumination expansion unit CA-DC40E/DC50E/DC60E, the lighting and
Illumination control -
light intensity of the LED illumination can be controlled.*5
Cooling fan Cooling fan unit CA-F100 is standard equipment
Power source voltage DC24V±10%
Rating
Consumption current 5.3 A 3.1 A
Ambient temperature 0 to +45°C (DIN rail mounted)/0 to +45°C (Bottom mounted)
Environmental resistance
Ambient operating humidity 35 to 85% RH (no condensation)
Weight Approx. 1750 g
*1 Since the controller unit does not support camera inputs, at least 1 camera input unit (optional) or more is required.
*2 LJ-V Series heads whose models end in "B" are luminance output types. To connect to a luminance output type, the XG-X2800/2802/2900/2902 and the CA-E110LJ are required.
*3 Either positive common connecting which is compatible with NPN input instruments, or negative common connecting which is compatible with PNP input instruments is feasible.
*4 Models equipped with the Ethernet port in the CPU unit support Ethernet port direct connection.
*5 Connect up to 8 illumination expansion units (note that the eight units can include only a maximum two CA-DC50E or CA-DC60E units or one each).
14
Dimensions
Controller Unit XG-X2000/2002/2200/2202/2500/2502
122
19.3
118 141.6
DIN-rail
mounts
168
35.9
83.3
65.3
(90) 124.6
M4 M4
Depth: 6 Depth: 6
12.5
93
M4 M4
Depth: 6 94 Depth: 6
12.1
Unit: mm
With Area Camera Input Unit CA-E100/Illumination expansion unit CA-DC40E installed
185.8
181.8
149.9
40 141.6
118
DIN-rail
mounts
168
35.9
83.3
65.3
90 124.6
94
12.1
93 34.6 31.9 8-M4
16.5 Unit: mm
Depth: 6
15
Controller Unit XG-X2700*/2702*/2800/2802/2800LJ/2900/2902
145.7
19.3
118 141.6
DIN-rail
mounts
168
35.9
139.2
83.3
65.3
124.6
M4 M4
Depth: 6 Depth: 6
12.5
93
M4 M4
Depth: 6 Depth: 6
94
12.1
111.8 Unit: mm
* Only the XG-X2700/2702 is equipped with camera connectors in the same place as the XG-X2000/2002.
With Line Scan Camera Input Unit CA-E100L*/CC-Link unit CA-NCL20E installed
216.1
188.4
156.5
118 141.6
DIN-rail
mounts
168
35.9
139.2
83.3
65.3
90 124.6
94
12.1
8-M4
40.2 93 41.2 31.9 Depth: 6 Unit: mm
* CA-E100L can only be connected with XG-X2800/2802/2900/2902.
16
3D Camera Input Unit CA-E100T Illumination Expansion Unit CA-DC50E
12.4 12.4
31.9 31.9
DIN-rail DIN-rail
mounts mounts
168 168
35.9 35.9
83.3 83.3
65.3 65.3
6 6
124.6 60 124.6
2xM4 2xM4
Depth: 6 Depth: 6
22.1 22.1
94 Unit: mm 94
12.1 12.1 Unit: mm
DIN-rail DIN-rail
mounts mounts
83.3
83.3
65.3
65.3
6
6
90
60 124.6
124.6
2xM4
2xM4
Depth: 6 Depth: 6
22.1
43.7
94 Unit: mm
12.1
94
12.1 Unit: mm
High-speed Line Scan Camera Input Unit CA-E200L EtherCAT Unit CA-NEC20E
12.4 12.4
53.5 31.9
DIN-rail DIN-rail
mounts mounts
83.3 83.3
65.3 65.3
6 6
124.6 90
60 124.6
2xM4
Depth: 6 2xM4
Depth: 6
43.7 22.1
94 Unit: mm
94 12.1
12.1 Unit: mm
17
18
19
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were used
merely to illustrate the general type and quality of the Products and not to
represent that the Products would necessarily conform to said models or
samples. Any Products found to be defective must be shipped to KEYENCE
with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will
refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting
from any action of Buyer, including but not limited to improper installation,
improper interfacing, improper repair, unauthorized modification,
misapplication and mishandling, such as exposure to excessive current, heat,
coldness, moisture, vibration or outdoors air. Components which wear are not
warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the
fitness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF
PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM
LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS
OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE
COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR
TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS,
EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED
OF A POSSIBLE THIRD PARTY'S CLAIM FOR DAMAGES OR ANY OTHER
CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing
warranty disclaimers or damage limitations may not apply.
E 1101-3