You are on page 1/ 8

3500/05 System Rack

Datasheet
Bently Nevada Machinery Condition Monitoring 141525 Rev. M

Description
 
Use the 3500 System rack to mount all 3500 monitor modules
and power supplies.  The rack allows you to place 3500
modules near one another, enabling them to easily
communicate, and to mount power supplies necessary to
distribute power to each module.
3500 racks are available in two sizes:
Full-size rack. 19-inch EIA rack with 14 available module slots.
Mini-rack. 12-inch rack with seven available module slots.
You can order 3500 racks in three formats:
Panel mount. This rack format mounts to rectangular cut-
outs in panels, and secures to the panel using clamps
supplied with the rack.  Wiring connections and I/O modules
are accessible from the rear of the rack.
Rack mount. This rack format mounts the 3500 Rack on 19-
inch EIA rails.  Wiring connections and I/O modules are
accessible from the rear of the rack.
Bulkhead mount. This rack format mounts the rack against a
wall or panel when it is not possible to access the rear of the
rack.  Wiring connections and I/O modules are accessible
from the front of the rack.  The 3500/05 Mini-Rack is not
available in this format.
The power supplies and rack interface module must occupy
the far-left rack positions.  The remaining 14 rack positions
(seven rack positions for the mini-rack) are available for any
combination of modules. 

If you plan to install internal barriers in the 3500 rack,


consult Specifications and Ordering Information for
3500 Internal Barriers (document 141495) available
from Bently.com.
3500/05 System Rack
Datasheet 141525 Rev. M

Compliance and Hazardous Area Approvals


Certifications For the detailed listing of country and product
specific approvals, refer to the Approvals Quick
FCC Reference Guide (108M1756) available from
Bently.com.
This device complies with part 15 of the
FCC Rules. Operation is subject to the CSA/NRTL/C
following two conditions:
Class I, Zone 2: AEx/Ex nA nC ic IIC T4
 l This device may not cause harmful Gc;
interference. Class I, Zone 2: AEx/Ex ec nC ic IIC T4
Gc;
 l This device must accept any Class I, Division 2, Groups A, B, C,
interference received, including and D;
interference that may cause  
undesired operation. T4 @ Ta= -20˚C to +65˚C (-4˚F to
+149˚F)
EMC When installed per drawing 149243
or 149244.
European Community Directive:
ATEX/IECEx
EMC Directive 2014/30/EU
Standards: II 3 G
EN 61000-6-2 Immunity for Ex nA nC ic IIC T4 Gc
Industrial Environments Ex ec nC ic IIC T4/T5 Gc
 
EN 61000-6-4 Emissions for T4 @ Ta= -20˚C to +65˚C
Industrial Environments (-4˚F to +149˚F)
When installed per drawing 149243
Electrical Safety or 149244.
European Community Directive:  

LV Directive 2014/35/EU
Standards:
EN 61010-1
European Community Directive:
RoHS Directive 2011/65/EU
ABS - Marine and Offshore Applications
DNV GL Rules for Classification – Ships,
Offshore Units, and High Speed and Light
Craft

2/8
3500/05 System Rack
Datasheet 141525 Rev. M
02 ATEX/IECEx/CSA (Class 1, Zone 2) 

Ordering Considerations D: Reserved


00 None
Racks with Internal Barriers installed require a E: European Compliance Option
3500/04-01 Internal Barrier Earthing Module to
01 CE
provide the IS Earth connection to the 3500/05
rack.  This earthing module requires a
Spares
dedicated rack position.
The 3500/93 System Display A01 System Face Part Number Description
Mount option is incompatible with the 3500/05 Half-height Module Adapter
Mini-rack. Half-height module Internal Chassis
125388-01
(qty 1)
The 3500/05 mini-rack is not available in the
Half-height Module Card Guide (qty
Bulkhead Mount option. 125565-01
1)
The 3500/06 weatherproof housing is not Screws for half-height Module
04300111
compatible with the 3500/05 Bulkhead Mount Internal Chassis (qty 3)
option. Power Supply Blank Cover Kit
When using a 3500 mini-rack in an EIA rack, a Power Supply Blank Front Panel (qty 1,
131150-01
144863-01 19-inch EIA Adapter Panel is required. includes screws)
Power Supply Input Connector Cover
The 3500 mini-rack requires Version 2.70 or later 128085-01
(qty 1) Order part 04310251 for screws.
of the 3500/01 Software.
Screws for Power Supply Input Cover
04310251
(qty 2)
Ordering Information
Full-height Blank Monitor Cover Kit Order as
For the detailed listing of country and product 130768-01. Includes:
specific approvals, refer to the Approvals Quick Full-height Monitor Blank Front Panel
Reference Guide (108M1756) available from 130944-01
(qty 1, includes screws)
Bently.com.
I/O Module Cover (qty 1) Order part
128031-01
Product Description 04310251 for screws.
04310251 Screw for I/O Module Cover (qty 2)
3500/05-AA-BB-CC-DD-EE Half-height Blank Monitor Cover Kit
Half-height Blank Front Panel Cover
131151-01
A: Rack Size (qty 1, includes screws)
01 19-inch Rack (14 module slots) Miscellaneous Components
02 12-inch Mini-Rack (7 module slots) TMR/SIM jumper (installed on the
00561941
B: Mounting Options 3500 backplane)

01 Panel Mount Option, Full-Size Rack 144863-01 Adapter Panel, Mini-rack, 19-inch

Rack Mount Option, Full-Size Rack (mounts to Rack Installation and Maintenance
02 129766-01
19-inch EIA Rack) Manual

Bulkhead Mount Option (not available in 130432-01 Field Wiring Diagrams


03
Mini-Rack)
04 Panel Mount Option, Mini-Rack
05 Rack Mount Option, Mini-Rack
C: Agency Approval Option
00 None
01 CSA/NRTL/C (Class 1, Division 2)

3/8
3500/05 System Rack
Datasheet 141525 Rev. M

Figures and Drawings

 1. 265.94 mm (10.470 in.)


 2. 482.60 mm (19.000 in.)
 3. 441.96 mm (17.400 in.)
 4. 246.38 mm (9.700 in.)
 5. 349.25 mm (13.750 in.), 422.91 mm (16.650 inches) if used
with internal barriers
Figure 1:  3500 Full-Size rack mounting dimensions for the Rack and Panel Mount Configuration

 1. 452.1 +/- 1.5 mm (17.80 +/- 0.06 in.)


 2. 3.2 mm (0.125 in.) radius, maximum
 3. 251.5 +/- 1.5 mm (9.90 +/- 0.60 in.)
 1. 452.1 +/- 1.5 mm (17.80 +/- 0.06 in.)
 2. 3.2 mm (0.125 in.) radius, maximum
 3. 251.5 +/- 1.5 mm (9.90 +/- 0.60 in.)
Figure 2:  3500 Full-Size Rack Recommended Panel Cutout

4/8
3500/05 System Rack
Datasheet 141525 Rev. M

 1. 10.470 inches (265.94 mm).


 2. 12.000 inches (304.80 mm).
 3. 10.400 inches (264.16 mm).
 4. 9.700 inches (246.38 mm).
 5. 13.750 inches (349.25 mm), 16.650 inches (422.91 mm) if
used with    internal barriers
Figure 3:  3500 Mini-rack mounting dimensions for the Panel Mount Configuration

 1. 274.3 +/- 1.5 mm (10.80 +/- 0.06 in.)


 2. 3.2 mm (0.125 in.) radius, maximum.
 3. 251.5 +/- 1.5 mm (9.90 +/- 0.60 in)
Figure 4:  3500 Mini-rack Recommended Panel Cutout

5/8
3500/05 System Rack
Datasheet 141525 Rev. M

 1. 3500 Mini-rack


 2. Adapter Panel
 3. Standard 19-inch EIA rack
Figure 5:  3500 Mini-rack and Adapter Panel mounting to a 19-inch EIA Rack

6/8
3500/05 System Rack
Datasheet 141525 Rev. M

 1. 482.60 mm (19.000 inches)


 2. 459.59 mm (18.094 inches)
 3. 133.35 mm (5.250 inches)
 4. 190.50 mm (7.500 inches)
 5. 133.35 mm (5.250 inches)
 6. 532.64 mm (20.970 inches)
 7. 266.70 mm (10.500 inches)
Figure 6:  Dimensions of a Bulkhead Mount 3500 rack

7/8
3500/05 System Rack
Datasheet 141525 Rev. M

Copyright 2020 Baker Hughes Company. All rights reserved.

Bently Nevada and Orbit Logo are registered trademarks of Bently Nevada, a Baker Hughes Business, in the United
States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company. All other product and
company names are trademarks of their respective holders. Use of the trademarks does not imply any affiliation
with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does
not make any representation as to the accuracy or completeness of the information and makes no warranties of
any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and
fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.

1631 Bently Parkway South, Minden, Nevada USA 89423


Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com

8/8