0% found this document useful (0 votes)
95 views2 pages

Catalog 01 PD5-1

This document summarizes the specifications and functions of the BGS Type Photoelectric Switch PD5 Series. It has two models, one for AC power and one for DC power. It uses infrared LED projection and 2-segment photo diode reception to detect objects in the range of 0.1-1m or 0.1-2.5m depending on the model. It has functions to suppress background interference using the 2-segment reception and can detect opaque or semi-transparent objects passing by.

Uploaded by

Amir Qayyum
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views2 pages

Catalog 01 PD5-1

This document summarizes the specifications and functions of the BGS Type Photoelectric Switch PD5 Series. It has two models, one for AC power and one for DC power. It uses infrared LED projection and 2-segment photo diode reception to detect objects in the range of 0.1-1m or 0.1-2.5m depending on the model. It has functions to suppress background interference using the 2-segment reception and can detect opaque or semi-transparent objects passing by.

Uploaded by

Amir Qayyum
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Long distance

BGS Type Photoelectric Switch


S

PD5 SERIES
Photoelectric Sensor

Not affected by background


Stable detection with 2.5m
●2 kinds of sensors are lined-up,1m & 2.5m. It is available for
position detection or passing detection on the lines.
● It is less affected by colors, materials or shapes of detection
objects.
● It can make the severe setting without the affection of back-
ground because 2-segment photo diode is applied.

■ Distance setting
BGS (Background Suppression) function without background

Principle: ON OFF
When object and background are separated BGS (Background sup- (Enter to (Enter to element B
Element A) or not enter)
pression) function The sensor judges that an object is present when
Reception
Projection
light is received at position A of the light-receiving element (2-seg- element
lens
ment element). This is useful if the object and background are far A
apart. B
Not affected if the background color changes or someone passes
behind the conveyor.
Back-
ground
Projection
lens Work Moving object
Reception
in the back
element
Setting distance

FGS (Foreground Suppression) function without background

When object and background are close Without work With work With grossy work
together. OFF ON ON
When the object is glossy or uneven FGS
(Foreground suppression) function The Projection
element
sensor judges that no object is present when
light is received at position B of the light A B A B A B

receiving element (2-segment element) (The


conveyor is detected). This function is useful
if the object and the background are close Lens
Reception
together or if the object is glossy or uneven. element
However, sensing is impossible if there is no
Setting distance
background (conveyor, etc.).

Conveyer Conveyer Conveyer

Enter to element B Enter to element A Judge work is existing


(Absolute requirement to exist because of not enter to
conveyer or background) element B

■ Specifications
Kinds Free-power type DC power type
Model No. PD5-1MA PD5-2MA PD5-1MC PD5-2MC
24 to 240VAC (±10%, 50/60Hz)
Power source 12 to 24VDC (±10%, ripple 10% or less)
12 to 240VDC (±10%, ripple 10% or less)
Current consumption 4VA or less: AC power, 3W or less: DC power 45mA or less
Projecting element Infrared LED (modulation)
Receiving element 2-segment photo diode
Detectable range* 0.2 to 1.0m 0.2 to 2.5m 0.2 to 1.0m 0.2 to 2.5m

20
Detecting distance* 0.1 to 1.0m 0.1 to 2.5m 0.1 to 1.0m 0.1 to 2.5m

S
Detectable objects Semi-transparent/opaque objects
Detecting mode BGS BGS/FDS Changeover type
Distance adjuster Provided (mechanical adjuster with indicator)

Photoelectric Sensor
Hysteresis* 10% or less of operating distance
Operating mode Changeover of Light-ON/Dark-ON
1a relay, 250VAC 3A, 30VDC 3A NPN/PNP open-collector 2 output
Output Electrical life: 0.1 million times or more 30VDC 100mA or less
Mechanical life: 50 million times or more Residual voltage: 1V or less (at 100mA)
Response time 20msec or less 2msec or less
Operating lamp (Orange LED): lights up when output ON, Stable lamp (Green LED): Lights up when
Indication lamps
stable operation
Connection Terminal box
Ambient illuminance Sunlight: 10,000lx or less, incandescent lamp: 3,000lx or less
Ambient temperature -25 to +55℃ (-30 to +70℃ when stored)
Ambient humidity 35 to 85%, not icing/not condensing
100MΩ or more (by 500VDC megger): Energized
20MΩor more (by 250VDC megger): between
Insulation resistance part, non energized metal part contact output each
energized part and case
other
Vibration resistance Double amplitude 1.5mm, 10 to 55Hz, each 2 hour in X, Y and Z directions
Impact resistance 500m/s2, each 3 time in X, Y and Z directions
2,000VAC/min.: energized part, non energized
Withstand voltage metal pat contact output each other 1,000VAC/min.:between energized part and case
1,000VAC/min.: between contacts
Protective structure IP67 (IEC standard)
Case material Case: ABS resin, lens: polycarbonate
Weight Approx. 100g Approx. 85g
Accessory Adjuster, fitting metal, screw
*Setting range is max.range of setting adjuster.
Detectable range, distance and hysteresis are made by white paper with 200×200mm.

■ Output circuit
Free power type DC power type Terminal arrangement
1 (AC24 to 240V, DC12∼240V) 1 (DC12 to 24V)

2 (0V) Power 4 (PNP) Load


① ②
Main DC
Main circuit 3 circuit 3 (NPN) Power ③ ④
Load
4 2 (0V)

■ External dimensions
Sensor Fitting metal under installation
Distance adjuster (2 rev.) Stable lamp (green)
30.5

13.5
17.5

Indicator Operating mode changeover


29

switch (insise)*

6.5
6.5

Operating lamp (orange)


φ6.5 10 58 10

Receiving part 3-φ5.1 hole


Projecting part 2-M5×32 screw
26 68 (center of detection)
268
58

58

88
22

37
5

18

5 30
Projecting part
(center of detection) 58
58
2

*Changeover of operating mode is made by dipswitch for DC power type.