ASCO™ Signaling Unit, Flameproof Enclosure
IECEx/ATEX, II 2G Ex db IIC Gb / II 2D Ex tb IIIC Db IP66/IP67 Series
Aluminium or stainless steel enclosure, for series 290 and 390 valves 890
Features and Benefits
• Explosionproof signaling unit for use in potentially explosive atmospheres according to
ATEX-Directive 2014/34/EU
EC type examination certificate no.: LCIE 17 ATEX 3023 X
IECEx Certificate of Conformity no.: IECEx LCIE 17.0035 X
• Compliance with the Essential Health and Safety Requirements has been assured by
compliance with the International and European Standards EN-IEC 60079-0,
EN-IEC 60079-1 and EN-IEC 60079-31
• Two integrated sensors for both end-of-travel position detections
• Easy electrical installation by means of a screw terminal
• Enclosure provided with a 1/2 NPT threaded entry hole (M20 x 1.5 in option) for
a broad range of cable entries
• Ingress protection degree IP66/67
Operation
At both end-of-travel positions (open and closed) of the valve stem, the signaling unit
permanent magnet operates contacts which provide an electrical signal indicating that
the end position is reached.
General
REED switch sensor Magneto-resistive sensor
Ambient temperature range -40°C to +80°C -10°C to +60°C
(-40°F to 176°F) (14°F to 140°F)
Safety code III 2G Ex db IIC T4 Gb II 2G Ex db IIC T6 Gb
II 2D Ex tb T135°C IIIC Db II 2D Ex tb T85°C IIIC Db
Degree of protection IP66/IP67 (EN 60529) IP66/IP67 (EN 60529)
Construction
Body Chromated aluminium, epoxy coated or
stainless steel (AISI 316L)
Bonnet Stainless steel (nickel plated)
Valve adaptor Stainless steel
Tube Stainless steel
Nameplate Stainless steel
Connection Embedded screw terminals
Fastener and screws Stainless steel
Electrical characteristics (1)
REED switch sensor Magneto-resistive sensor
Function ON/OFF ON/OFF
Max. breaking power 6 VA (AC/DC) 0.6 W
Switching voltage AC/DC: 5 to 48 V max. 10 to 28 V DC
Availability, design and specifications are subject to change without notice. All rights reserved.
Max. switching current 100 mA 20 mA
Short-circuit protection No No
Reverse polarity protection - No
Wiring 2 wires /sensors 2 wires /sensors Reed switch version
Voltage drop < 0.1 V VERSION MR < 3.5 V
Surge suppression - Yes VERSION REED
Electrical connection 1 terminal block with 4 positions and
ground connection
Grip, cross section stranded wire:
Minimum 0.14 mm² (25 AWG)
Maximum 1.5 mm² (15 AWG)
Wire strip length 5 mm (0.2 in)
Cable entry Any ATEX approved cable entry device can be fitted in
the 1/2” NPT threaded entry hole (M20 x 1.5 in option).
Refer to the nameplate for identification of the maximum
cable temperature
(1)
Indicated values for one sensor.
Magneto-resistive version
Certifications and Approvals
01553GB-2022/R01
VERSION MR
•RoHS compliance
•IECEx, ATEX
•ATEX Directive 2014/34/EU and EN/IEC 60079-0, EN/IEC 60079-31
Visit our website at Emerson.com/ASCO 1
Series
890 ASCO™ Signaling Unit, Flameproof enclosure
Product selection guide
PRODUCT CODE
P 890 A D 1 1 1 1 AT1 F1
Product series Voltage
890 = S
ignaling unit for air operated valves F1 = 24V DC
F9 = 5 to 48V AC/DC (1)
Revision letter Options
A = Initial release AT1 = ATEX/IECEx -
«d» Flameproof enclosure
Enclosure type Actuator type (290/390)
D = Signaling unit - Flameproof enclosure 1 = Stainless steel actuator 63 mm
2 = Stainless steel actuator 90 mm
Sensor type 3 = Plastic actuator 63 mm
1 = REED switch 4 = Plastic actuator 90 mm
2 = Magneto-resistive switch 5 = Plastic actuator 125 mm
Enclosure type Valve Function
1 = Aluminum enclosure - 1/2” NPT 1 = 290 NC
2 = Aluminum enclosure - M20 x 150 2 = 290 NO
nnection3 = Stainless steel enclosure - 1/2” NPT
4 = Stainless steel enclosure - M20 x 150
24V version
connection
3 = 390 NC
4 = 390 NO
(1)
With REED switch sensor type.
8V version connection
Installation 24V version
connection 24V version
con
• The signaling box can be installed in any position
• Adjustable signaling box enables 360° access to cable gland
• Installation/maintenance instructions are included with each signaling box
• Electrical connection: 6 6 6
REED sensors adjustment MR sensors adjustment
7 7
+ + 7
Sensor 1
+ + open position
Sensor open position - -
- -
+ + Sensor close position + +
- -
8 8 Fig.6 -
Sensor 2
close position
-
Availability, design and specifications are subject to change without notice. All rights reserved.
+ Red + Brown
- Black - Blue
Fig.68 OPEN
CLOSE
3
01553GB-2022/R01
2 Visit our website at Emerson.com/ASCO
1. Remove
1. Remove the clip 6 and the washer 7 (Fig 5) the clip 6 and the washer 7 (Fig
nector 3 (Fig 2)
Series
ASCO™ Signaling Unit, Flameproof enclosure 890
Dimensions mm (inches), Weight kg (Lbs) Configurator - CAD Files
Angle seat valve - Plastic actuator
(with aluminium or stainless steel enclosure)
ØL4
L3
L2
L1
Weight
(signaling box alone)
Aluminium Stainless steel
1.4 2.7 kg
3.086 5.952 (Lbs)
Availability, design and specifications are subject to change without notice. All rights reserved.
Signaling unit, flameproof enclosure, mounted on plastic actuator
Actuator
diameter L1 L2 L3 ØL4
mm 69 81 65 97
63 mm
(in) 2.717 3.189 2.559 3.819
mm 58 73 65 97
90 mm
(in) 2.283 2.874 2.559 3.819
mm 44.5 61.5 65 97
125 mm
(in) 1.752 2.421 2.559 3.819
01553GB-2022/R01
Visit our website at Emerson.com/ASCO 3
Series
890 ASCO™ Signaling Unit, Flameproof enclosure
Dimensions mm (inches), Weight kg (Lbs) Configurator - CAD Files
Angle seat valve - Stainless steel actuator
(with aluminium or stainless steel enclosure)
ØL4
L3
L2
L1
Weight
(signaling box alone)
Aluminium Stainless steel
1.4 2.7 kg
3.086 5.952 (Lbs)
Signaling unit, flameproof enclosure, mounted on stainless steel actuator
Actuator
diameter L1 L2 L3 ØL4 , design and specifications are subject to change without notice. All rights reserved.
mm 69,5 81,5 65 97
63 mm
(in) 2.736 3.209 2.559 3.819
mm 60 73,5 65 97
90 mm
(in) 2.262 2.894 2.559 3.819
01553GB-2022/R01
4 Visit our website at Emerson.com/ASCO