2018 International
Existing Building Code
(IEBC)
Self-Certification
Program
Rost Sapon
Structural Plans Engineer
2018 IEBC
Chapter 1 Amended
Chapter 1 Administration –
• Section 101.1 – Title
• Section 101.2 – Scope
• Section 101.3 – Intent
• Section 101.4 through the end of chapter 1 deleted and
amendment with reference to amended IBC sections.
Core Definitions
• The IEBC has far fewer definitions than the IBC.
• The definitions that do exist matter much more.
We will go over many core definitions.
• The wording of the definitions is very important.
• Reading them one time may cause errors of
application. Read them a few times.
Core Definitions
ADDITION – An increase in floor area, number of stories,
or height of a building or structure
ALTERATION – Any construction or renovation to an
existing structure other than a repair or addition
Note! A change of occupancy is also an alteration if
any work is done.
REPAIR – The reconstruction, replacement, or renewal of
any part of an existing building for the purpose of its
maintenance or to correct damage
Core Definitions Continued
CHANGE OF OCCUPANCY. A change in the use of a
building or portion of a building that results in any of
the following:
1. A change of occupancy classification. (A, B, F, M)
2. A change from one group to another group
within an occupancy classification (A-3, A-2)
3. Any change in use within a group for which
there is a change in application of the
requirements of this code.
Nursing home (I-2) changed to psychiatric care (I-2) is a change
of occupancy because it changes the use for which there are
additional or differing code requirements.
Chapter 3
Compliance Methods
This chapter outlines three options for alterations,
additions, or change of occupancy. You can use ONLY
one method. No mixing methods.
1. Prescriptive compliance method
Chapter 5
2. Work area compliance method
Chapters 6 through 12
Depends on the definition of work area
3. Performance compliance method
Chapter 13
Chapter 3
General Provisions and
Accessibility
This chapter also contains all the accessibility
provisions that apply to all 3 methods of
compliance.
CANNOT reduce existing accessibility and existing
accessible features below the minimum required by
the IBC for new buildings.
Accessible means of egress is not required in
alterations of existing buildings.
Core Definitions
PRIMARY FUNCTION – A major activity for which the
facility is intended
Examples: Customer services lobby in a bank, office area in a
bank, dining area in a cafeteria, and office areas in office
building.
Examples that are not: Mechanical rooms, supply storage
rooms, employee lounges, and janitorial closets.
TECHNICALLY INFEASIBLE – …existing structural
conditions require the removal or alteration of a load-
bearing member that is an essential part of the
structural frame… site constraints prohibit modification
or addition of elements, spaces or features…
Chapter 4
Repairs
Repairs are separate from the 3 compliance methods.
Glazing in hazardous areas shall comply with the safety
glazing requirements of the IBC or IRC.
Repairs shall maintain the level of fire protection
provided.
Repairs shall maintain the level of protection for the
means of egress.
Core Definition
SUBSTANTIAL STRUCTURAL DAMAGE – A condition where
any of the following apply:
1. The vertical elements of the lateral-force-resisting
system have suffered damage such that the lateral load
carrying capacity of any story in any horizontal direction
has been reduced by more than 33 percent from its pre-
damaged condition.ES, BRACED FRAMES, CANTILEVERED
COLUMNS
2. The capacity of any vertical component carrying
gravity load, or any group of such components, that has a
tributary area more than 30 percent of the total area of
the structure’s floor(s) and roof(s) has been reduced more
than 20 percent from its pre-damaged condition, and the
remaining capacity with respect to dead, and live loads is
less than 75 percent of that required by the IBC…COLUMNS
Chapter 5
Prescriptive Compliance Method
This is the most conservative method.
Additions shall comply with the IBC.
o Existing building in combination with the addition shall
not be less compliant with the IBC than before the
addition.
o Structural gravity load increased on structural element by
more than 5 percent shall be analyzed for the new loads.
o Existing gravity resisting structural element whose
capacity is reduced shall be analyzed for the new loads.
o Existing lateral load resisting elements shall be analyzed
for existing and new demand to capacity ratio.
Chapter 5
Prescriptive Compliance Method
Alterations shall comply with the IBC except:
o Existing materials already in use and approved at the time of
their erection may remain unless deemed unsafe by the
building official.
o Replacement materials for repairs and alterations may be like
existing materials if not deemed unsafe by the building official.
o Structural gravity load increased on structural element by more
than 5 percent shall be analyzed for the new loads.
o Existing gravity resisting structural element whose capacity is
reduced shall be analyzed for the new loads.
o Existing lateral load resisting elements shall be analyzed for
existing and new demand / capacity ratio.
Chapter 5
Prescriptive Compliance Method
Fire escapes:
o Existing fire escape can continue as a component of not more
than 50% of the means of egress.
o New fire escape is limited on existing buildings.
o New fire escape not allowed on additions.
Windows and emergency escape windows:
o Glass and glazing shall comply with IBC Chapter 24.
o Provisions provided for replacement window control devices, and
for emergency escape and rescue openings for R-2 and R-3.
Chapter 5
Prescriptive Compliance Method
Change of occupancy:
o Provisions of the IBC required for the new occupancy in the
portion of the building with the change.
Historic buildings:
o Provisions related to existing condition of building.
o Improvements required if deemed by the building official as a life
safety hazard.
o All structural damage allowed to be restored to predamage
condition.
Work Area Chapter 6
Classification of Work
Depends on the work area. The work area shall be
clearly identified on the construction documents.
Provides various levels of work and types of work
o Alterations Level 1, Level 2, and Level 3
o Change of Occupancy
o Additions
o Historic Buildings
Core Definitions
WORK AREA – That portion or portions of a building
consisting of all reconfigured spaces as indicated on the
construction documents. Work area excludes other
portions of the building where incidental work entailed
by the intended work must be performed and portions
of the building where work not initially intended by the
owner is specifically required by this code.
Work Area
Three Levels of Alterations
Work Area Chapter 7
Alterations – Level 1
Level 1 alterations include interior finishes, interior trim,
and roof covering.
Special mention of emergency escape and rescue
openings.
o If you replace a window you may need to consider this.
Mostly requires compliance with the IBC for the new
finishes, trim, and new work. Like materials allowed if
they don’t create unsafe condition per 302.4 an d
Structural gravity load 5 percent rule.
Work Area Chapter 7
Alterations – Level 1
Alteration shall maintain the level of fire protection
provided.
Alteration shall maintain the level of protection for the
means of egress.
Work Area Chapter 8
Alterations – Level 2
Involves space reconfiguration that does not exceed
50% of the building area.
Requires compliance with level 1 provisions.
Structural lateral demand / capacity ratio 10
percent rule
All new construction elements, components, systems,
and spaces shall comply with IBC requirements, with 6
exceptions…
Work Area Chapter 8
Alterations – Level 2
Requires existing openings between stories to be
closed and rated, with 14 detailed exceptions…
Intricate and detailed means of egress requirements
for alternatives to full IBC compliance
Work Area Chapter 9
Alterations – Level 3
Involves alterations that cover 50% or more of the
aggregate area of the building.
Additional building features are triggered beyond the
actual work area and other parts of the building
where no alterations are planned.
Basic principle is that Level 3 alterations will comply
with the IBC, but with specific alternative options.
Must comply with alteration Level 2 provisions.
Work Area Chapter 10
Change of Occupancy
The requirements of Chapter 10 are in addition to the
requirements of Chapters 7, 8, and 9 (incremental
approach).
Sections 1002 – 1010
– Change of use by reconfiguring a space within the
same occupancy classification where there is a change
in application of the requirements of this code.
– Requires compliance with IBC chapter 4 when specific
categories are created. Examples are atriums, stages,
hazardous materials, I-2, and ambulatory care.
Work Area Chapter 10
Change of Occupancy
Section 1011
– Change of occupancy classification.
Work Area
Chapter 11 Additions
Additions are required to comply with current codes for
new construction except as modified by this chapter.
The existing building can remain without any alteration
provided the addition does not impact the existing
building.
Example: Existing means of egress passes thru new
addition and may require additional exit in existing
building due to travel distance.
Work Area Chapter 12
Historic Buildings
Do not forget the Phoenix amendments to the IEBC.
Most deal with historic buildings.
Other considerations for a historical building include the
structural condition of the building, its proposed use, its
impact on life safety and how the intent of the code will
be achieved.
Chapter 13
Performance Compliance Method
Chapter 13 emphasizes 19 important safety
parameters to be evaluated in determining the level
of safety for an existing building.
Requires a structural analysis.
Peformance Compliance
19 Safety Parameters
• Building Height • Smoke Control
• Building Area • Means of Egress
• Compartmentation • Dead ends
• Tenant and Dwelling • Max Exit Travel Distance
Separations • Elevator Control
• Corridor Walls • Means of Egress Emergency
• Vertical Openings Lighting
• HVAC Systems • Mixed Occupancies
• Automatic Fire Detection • Automatic Sprinklers
• Fire Alarm System • Standpipes
• Incidental Use
Performance Compliance Method
Table 1301.7 Summary Sheet
The 19 safety parameters are evaluated and entered in the
Summary Sheet
Three categories are totaled:
o Fire Safety
o Means of Egress
o General Safety
The scores are tallied in Table 1301.9 and if any of the 3
categories fail, the building doesn’t comply, and
adjustments shall be made until all 3 categories pass.
Chapter 14
Relocated or Moved Buildings
Any structure that is moved to a different lot or a
new location on the same lot falls within the scope
of Chapter 14
Questions?