You are on page 1/ 66

Complete manual

DiagPC

NON-DISCLOSURE AGREEMENT

1. All technical and commercial information, or information regarding models, procedures,


programs, computer applications, components, systems and tools contained in the
information presented is the property of THYSSENKRUPP ELEVATOR MANUFACTURING
SPAIN, S.L. and is deemed Classified Information, even if not expressly so stated,
whatever the storage medium employed.

2. The user undertakes and agrees to employ any Classified Information solely for issues
directly connected with the work entrusted to him/her by ThyssenKrupp. He/she may not
therefore employ Classified Information for the purpose of performing other tasks or
projects.

3. The user shall not disclose Classified Information to third parties for any reason or at any
time, even after conclusion of the work.

4. The user may grant access to Classified Information only to those ThyssenKrupp staff
members with a need to know in order to perform their own work, such individuals being
required to adopt the necessary measures in order to avoid disclosure to unauthorized
staff or third parties.

5. Disclosure of any Classified Information to the user does not imply any licence or
assignment of use, nor does it vest in the said party any corresponding industrial or
intellectual property rights.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 1 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

1. GENERAL DESCRIPTION 4

2. DESCRIPTION AND USE OF THE DEVICES 4

2.1. PC 4
2.2. CMC4 INTERFACE 5

3. INSTALLING THE SOFTWARE ON THE PC 5

3.1. PREREQUISITES 5
3.2. INSTALLING THE APPLICATION 5

4. ESTABLISH THE BLUETOOTH CONNECTION 10

5. GENERATING AND LOADING THE APPLICATION LICENCE. 24

5.1. CREATE FILE 24


5.2. UPLOAD LICENSE 25

6. DIAGPC APPLICATION 27

6.1. ADJUSTMENTS WINDOW. 27


6.2. MAIN MENÚ 28
6.3. FUNCTION 1 – CURRENT FAILURE 29
6.4. FUNCTION 2 – VISUALISING THE STATE OF THE DEVICE 30
6.5. FUNCTION 3 – FAILURE BATTERY 32
6.6. FUNCTION 4 – DELETE STACK 36
6.7. FUNCTION 5 – GENERATING CALLS 37
6.8. FUNCTION 7 – CAR CONTACTS 40
6.9. FUNCTIONS 8 TO 23 45
6.10. FUNCTION 24 – SCREEN PROGRAMMING 47
6.11. FUNCTION 25B – DIRECT ACCESS TO EXTERNAL MEMORY 55

7. ANSWER AND PROPOSED SOLUTION TO MOST COMMON ERRORS 64

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 2 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

7.1. INSTALLATION OF THE DIAGPC APPLICATION 64


7.2. BLUETOOTH PC – CMC4 INTERFACE PAIRING 65
7.3. USE OF THE DIAGPDA APPLICATION 65

8. REVISIONS LOG 66

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 3 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

1. GENERAL DESCRIPTION

The objective of this system is to perform the lift maintenance operations using a PC
which, via Bluetooth communication, connects to the specific interface of the unit we wish to
control.

This application, installed in any PC with Windows XP, aims to emulate the operation of
the POME tool in the CMC4 manoeuvre.

2. DESCRIPTION AND USE OF THE DEVICES

2.1. PC

The PC will have the following characteristics:

 Bluetooth.

Integrated in the computer or connected externally via USB-Bluetooth.

 Screen.

The application has been verified in screens with a resolution of between


1024x800 and 1280x1024.

 Operating system

Initially, the application will run on Windows XP and Windows 7 32 bits.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 4 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

2.2. CMC4 INTERFACE

The connection interface has two DB9-type connectors. The male Sub-D connector will be
used to enable communication between the manoeuvre and the PC.

3. INSTALLING THE SOFTWARE ON THE PC

3.1. PREREQUISITES

The DiagPC application requires the previous installation of NET Framework version 3.5
SP1. To this end, run the DotNetFx35Client.exe included in the installation CD, in the “Net
Framework” folder, and follow the instructions that appear on screen.

3.2. INSTALLING THE APPLICATION

First of all, ensure that the application is not already installed on the computer. If so,
uninstall it before continuing.

The steps to be followed are explained below in detail:

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 5 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

1) Run the DiagPC Installer.exe file included in the “DiagPC Installation” folder.
Start the installation process.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 6 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

2) Select the directory where you wish to install the application and if use will only be
enabled for the current PC user or for all users.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 7 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 8 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) Wait until the application has been completed.

4) Complete the installation process.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 9 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

4. ESTABLISH THE BLUETOOTH CONNECTION

In order for the application to work, the Bluetooth included in the CMC4 interface and on
the PC must be paired.

Pairing is managed from the Windows XP operating system, although in some cases, on
acquiring an external Bluetooth it may be accompanied by its own device management software.

The pairing process for Windows XP is explained below in detail, integrated in the
computer or connected externally via USB-Bluetooth. In order to carry out this pairing, you must
connect the CMC4 interface to the UCM board and activate the Bluetooth connection on your
computer.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 10 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Bluetooth integrated in the computer

1) Go to Start  Configuration  Control Panel  Bluetooth devices.


Click the Add button under the devices table.

2) Check the “My device is configured and ready to be detected” box. Next.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 11 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) Select “CMC Bluetooth Link”. Next.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 12 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

4) Select the “I wish to choose my own password” option. Enter the code:
1234. Next.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 13 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

5) Before clicking End, take note of the exit COM port number. It is of vital
importance to know this detail, because when the DiagPC application is
run for the first time this COM port number must be indicated.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 14 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

If for any reason you need to recall the COM port for communication with the CMC4
interface, you will not need to pair the device again. Just go back to Start  Configuration 
Control Panel  Bluetooth Devices. Under the COM Ports tab, take note of the outgoing port
for the CMC Bluetooth link.

In the following example, the communication COM port would be 18.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 15 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

USB-Bluetooth

1) Go to My Computer  My BlueTooth Places  Add bluetooth device

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 16 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

2) Next.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 17 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) Select “CMC Bluetooth Link”. Next.

4) Enter the code: 1234. Pairing

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 18 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

5) Check “Bluetooth Serial Port” box. Click Configuration.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 19 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6) Select the COM port number ant take note of this. It is of vital importance
to know this detail, because when the DiagPC application is run for the first
time this COM port number must be indicated.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 20 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

7) Next.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 21 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

8) End.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 22 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 23 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

5. GENERATING AND LOADING THE APPLICATION LICENCE.

5.1. CREATE FILE

With the objective of protecting the use of the DiagPC programme, in order to be able to
use the application you will need to obtain a use licence.

To obtain the licence, enter the required data in the window that appears the first time
the application is run.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 24 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Once you have entered the data, click the CREATE FILE button. Select where you would
like to save the file with extension *.tgp that will be generated.

Finally, send this file to [email protected], commercial


department, indicating DiagPC in the subject line.

Remember that you will not be able to use the application until you receive the licence
generated by ThyssenKrupp.

5.2. UPLOAD LICENSE

Once you have sent the file you generated in the previous step to ThyssenKrupp, you
should receive a reply e-mail with the application use licence.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 25 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

In order to load the licence, run DiagPC again. In the “Software Licence” window, click on
UPLOAD LICENSE. Select the file containing the licence received from ThyssenKrupp.

If the correct file has not been loaded, the application will not start and a message such
as the following will appear:

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 26 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Remember that the licence is for exclusive use with the computer that generated the file
and will be valid for six months. Specifically, the PDA will need two keys over a year (one per
each semester).

When the licence is due to expire within less than thirty days, whenever you use the
DiagPC application a message informing you of the number of use days left will appear.

Once the six-month validity period has elapsed, the “Software Licence” window will re-
appear. Click Upload Licence and select the new file with the licence that you should have
received.

6. DIAGPC APPLICATION

6.1. Adjustments WINDOW.

When the programme starts, the PC will try to establish a communication via the COM
port selected in the section referring to establishing the Bluetooth Communication. If this
procedure is not carried out automatically, the Adjustments menu will appear where you can
select the COM port that you selected previously. You will also be able to select the language of
the application, choosing an option from among Spanish, English, French or German.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 27 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Once you have selected the COM port, and only if the application does not start
automatically, close the application and restart it. if on the contrary the programme starts, it will
directly access the functions menu of the diagnostic tool for CMC4.

If you wish to change the language of the application once it has started, you can access
the Adjustments window via the main menu of the application.

6.2. MAIN MENÚ

The application menu contains 25 functions for diagnosing the control manoeuvre, an
Adjustments menu and a last Exit function.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 28 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6.3. FUNCTION 1 – CURRENT FAILURE

With this function you can visualise the current state of the manoeuvre. the information is
available inside the box and is displayed in the following manner:

 In black, the failure number in decimal format.

 In blue, the label associated with the failure.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 29 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

 In red, a brief explanation of the meaning of the failure.

In this and other functions, the blinking of the circle located in the upper left-hand corner
is synonymous of exchange of information between the PC and the manoeuvre, which indicates
the proper functioning of the device. In the event that it stops blinking, click on it to reconnect it,
both in this function and the rest.

6.4. FUNCTION 2 – VISUALISING THE STATE OF THE DEVICE

The information to be displayed in this function is divided in the following manner:

 Car position.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 30 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

 Next stop.

 Direction. Going Up, Going down or none.

 Speed. Revision, high, medium, low, levelling or stop.

 Safety series. Closed or Open.

 Presence series. Closed or Open.

 Interlocking series. Closed or Open.

 Door Status. Closed, Closing, Open or Opening.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 31 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6.5. FUNCTION 3 – FAILURE BATTERY

On accessing this function, the full failure stack present in the manoeuvre is downloaded.

The full list can be seen in the central box. Failures are displayed according to the date on
which they occurred, the first failure shown being the most recent.

The information is divided in the following manner:

 Failure. Failure Label.

 Failure no. Failure number in decimal format.

 Date. Date on which the failure occurred.

In the following example the most recent failure is nº 44-POWER_FAIL, which occurred on
7 February at 3:00 pm.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 32 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

You can obtain further information by clicking on any of the failures:

 No. failure.

 Position of the failure within the stack (0 for the most recent).

 Floor on which the failure occurred.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 33 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

 State of the lift when the failure occurred: stopped, stopped in a descending
direction, stopped with an ascending direction, motion without any direction,
motion with an ascending direction or motion with a descending direction.
Descend.

 Failure label together with a brief explanation thereof.

In the following example, if you click on the failure POWER_FAIL occurred on 7-2 at 3:00
pm, you will learn that it occurred while the lift was running without direction on the 0th floor due
to a power supply failure and that it occupies position 0 in the failure stack.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 34 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Beneath the box containing all the failures you can read the number of failures in the
E2PROM and the direction, if any occurred.

Finally, there are three buttons on the lower part:

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 35 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

 Delete. It eliminates the failures from the stack only if you click accept in the
window that opens.

 Reload. It requests a new failure stack download order from the manoeuvre.

 Exit. It returns to main menu.

6.6. FUNCTION 4 – DELETE STACK

Identical functionality as that of the delete button of function 3. If you click the accept
button you will delete the failure stack.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 36 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6.7. FUNCTION 5 – GENERATING CALLS

It allows you to make all types of calls in the lift. The screen is divided into three main
parts:

 Display. Located in the upper part. By default, if you do not wish to make any
call, it represents the current position of the car by a blue number located on the

left. Example of car at level 1:

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 37 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

If you wish to make a call, just click on the desired level, indicating it on the left in

red number(s). Example of a call at level 2

 Buttons. Located on the lower part of the display, these are distributed in the
following manner:

o Numbers. For selecting the level at which we wish to make the call.

o “Make Call” Button . Provided that a level has previously been selected
using the numeric buttons.

o “Cancel Call” Button . If you click on the display it will show the current
position of the car again.

o “Exit” Button . Return to main menu.

 Type of call. Selection of the type of call we wish to make.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 38 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Next we will explain the process for making a call through an example. Specifically, we
wish to make call from the Front Hall and Ascend to level 0 with the car at level 1.

1) On accessing the function, the car is at level 0.

2) In order to make a front up-call to level 0, we mark 0 and select go up on


the front hall as type of call.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 39 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) At this time the display no longer shows the current position of the car,

until we confirm or cancel the call. To confirm it click the button.

4) The display immediately indicates the position of the car again.

6.8. FUNCTION 7 – CAR CONTACTS

It represents information on the car contacts:

1) Doors. The information to be visualised, both in relation to the front door and the
back door is:

 End of open door.

 End of closed door.

 Capacitive edge.

 Safety edge and photocell.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 40 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

If the contact indicates OPEN, it means that it is activated or incorrectly


wired. On the contrary, when it indicates CLOSE it means that it is not activated.

Next we will show several examples.

a. Single-access lift. Front door closed.

b. Single-access lift. Front door opening/closing.

c. Single-access lift. Front door open.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 41 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

2) Load. Shows the load level. in the following example it would be 100%.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 42 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) Revision. It shows whether the Down, Up, Close Doors or Open Doors contact
has been activated in Revision mode. On entering this mode the blue bar
containing the name of the Revision turns Orange.

In the CMC4 manoeuvre this operating mode is common to simple and double
access, always activating Frontal Revision.

Let’s see some examples:

a. Single-access lift with the down contact actuated.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 43 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

b. Single-access lift under revision with the close doors contact


actuated.

4) Lift operators. As in the case of the Revision mode, on actuating the lift Operator
mode key, the blue box turns orange. The status of the Up, Down and Start key
contacts and the status of the 80% of maximum load contact are represented.

5) Miscellaneous. Shows the Car priority, Call inhibition and Stop contacts for
hydraulic lifts.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 44 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6.9. FUNCTIONS 8 TO 23

Operation is identical in all cases. The only thing that changes is the parameter we wish
to modify.

Functions 8, 20 and 21 are not activated for the CMC4 control manoeuvre.

Operation will be explained with an example. Specifically, the Maximum Door Time will be
changed from 4 seconds to 6 seconds. The steps are the following:

1. On accessing the function, the current value of the parameter is read, repeatedly
sending new read requests.

As can be observed in the following image, the maximum door time is 4 seconds.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 45 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

2. If you wish to modify the values, click on the label New value. To change it, we

can do so using the up and down arrows or using the slide at the bottom

3. Once you have selected the new value, you only have to click the Change button.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 46 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

4. A new read request will automatically be launched to verify that the manoeuvre
has effectively modified the parameter.

6.10. FUNCTION 24 – SCREEN PROGRAMMING

In order to facilitate the screen programming operation, on accessing this function all the
shaft screens are automatically read. The blue bar indicates screen reading progress.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 47 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

The information must be interpreted in the following manner:

 Type of screen.

o Stop screen.

o Change motion during ascent.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 48 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

o Change motion during descent.

 The number on the left indicates the level to which the screen corresponds.

To change the type of screen you only have to click on the symbol of the screen you wish
to modify, which will turn red if the screen is different to the current screen.

To modify the level to which a screen corresponds, click on the number and enter the new
value in the window that opens. Click Change.

This value can be entered using the numerical keyboard of the PC or using the up and
down selection arrows.

Next, on the main screen of the function, click the change button, reprogramming only
those screens different to the current screen. The progress is indicated by the red bar.

Next, we will show an example of how to overlap the screens corresponding to levels 0
and 1.

1) On accessing function 24 we automatically download the configuration of the


shaft screens. in the current example it consists of 4 stops.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 49 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

2) Click on change motion during descent of level 0 to convert it into change motion
during ascent. The symbol turns red.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 50 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) Repeat the same operation with change motion during ascent of level 1 to convert
it into change motion during descent.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 51 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

4) Click on the value 0 of the new change during ascent and select the value 1.
Change.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 52 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

5) Click on the value 1 containing the red down arrow and select 0. Change.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 53 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6) We have now completed the overlap. Click the Change button to confirm the
changes. Programming will be completed when the red progress bar reaches the
end and all the screens turn black.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 54 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

6.11. FUNCTION 25B – DIRECT ACCESS TO EXTERNAL MEMORY

For the CMC4 manoeuvre, only function 25B is active, not function 25.

The screen is divided as follows:

 Hexadecimal keyboard. It allows us to enter the memory address to be read


and/or modified and to enter a new value in said position.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 55 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

 Memory position and arrows display. Enter represent the memory position on
the left of the symbol = and its current value on the right.

Using the up and down arrows respectively located above and below the address
field, you can go directly to the previous or next address.

The cursor located on the left appears blinking, indicating the position where the
digit selected from the keys underneath will be entered. The position of the cursor
can be changed using the arrows located to the left and right.

 Control buttons and new value introduction display.

Once you have entered the memory position you wish to visualise, the New
Value label will appear. A new display is enabled (with a similar operation to the
previous display) indicating the new value in the memory position represented.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 56 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Once the two digits have been entered, the modify button will be enabled. Clicking
it will change the current value of the memory position.

Read orders are immediately relaunched, displaying the new value in the value field next
to the sign “=” of the upper display, returning to the initial situation but with the value modified.

In order to enter a new address, if it is contiguous to the current address you only have to
click on the up or down arrows and, if it is not contiguous, click on the left and right arrows to
move along the memory digits and enter the new memory position.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 57 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

In the following example we will see how to change the current value equal to 4 of
position 3000 to a new value equal to 7.

1) On accessing the function, the digit on the left-hand display is blinking. As we


write the memory address, the blinking moves toward the right digit.

We enter the value 3000 using the hexadecimal keyboard, whereupon the stored
value is immediately displayed.

2) By clicking on the New Value label we will enable the display to write the new
content of memory position 3000.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 58 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

3) Using the keyboard, we will enter the value 07. This will enable the Change
button.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 59 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

4) Clicking the Change button will send the write order to the control manoeuvre.
The new content will automatically be updated on the upper display.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 60 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

The foregoing explains how to Modify a memory position.

Let us assume that we wish to move from position 3000 to 3001. We would only have to
click on the Up arrow located above the display.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 61 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

If we wish to move from position 3000 to 2FFF, we would simply click on the Down arrow
located below the display.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 62 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

Finally, if we want to move to a memory address not contiguous to the current one, we
would use the Left and/or Right arrows until digit to be modified starts blinking.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 63 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

7. ANSWER AND PROPOSED SOLUTION TO MOST COMMON ERRORS

7.1. INSTALLATION OF THE DIAGPC APPLICATION

When installing the application, an error appears indicating that the correct .NET
Framework version is not installed.

Ensure, via the control panel, that you have installed .NET Framework version 3.5 SP1. If
so, please uninstall the current version and install the version included in the CD.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 64 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

When installing the application, a Windows installer error appears.

Contact the person of the department responsible for PC maintenance, as there is a


problem with the software that manages the installation/uninstallation of applications.

7.2. BLUETOOTH PC – CMC4 INTERFACE PAIRING

When searching for Bluetooth devices, CMC Bluetooth Link does not appear

Verify that the board to which the CMC4 interface is connected is correctly fed.

7.3. USE OF THE DIAGPDA APPLICATION

When running the application, a window appears with the message


CREATE_FILED_ERROR_55

Click Cancel. Restart the application, previously ensuring that the board to which the
interface is connected is correctly fed and that you have paired the PDA with the interface.

When executing functions F1-current failure, F2-device status or F7-car contact


status, they do not seem to correctly represent lift status.

Verify that the circle representing communication (located on the upper left-hand corner)
is blinking. If not, click on it once to resume the communication.

When running the application, the “Software Licence” screen reopens.

The six-month validity period must have expired. Click the Load Licence button and select
the new file that you should have received from ThyssenKrupp, which will allow you to use the
application for another 6 months.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 65 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:
Complete manual

DiagPC

8. REVISIONS LOG

ED Description Date 

1 Elaboración inicial. 10/11/2011 FCastillo


2 Se cambia el instalador. Se especifica que la 24/01/2011 FCastillo
aplicación funciona para Windows XP y 7 de 32
bits.

DOCUMENT Nº:
ThyssenKrupp Elevator Manufacturing Spain
EDITION: 2
Pág. 66 de 66
DATE: 25-01-2011 ©Copyright 2010
Cualquier reproducción parcial o total del documento debe realizarse con consentimiento escrito de
ThyssenKrupp Elevator Manufacturing Spain, S.L.
ISSUED:

You might also like