Solid, simple and smart:
advanced reliability in compressed air
CDX 4 - 840 Refrigerant Dryers
User benefits
Simple installation
- Light and compact design
CDX
- Easy to transport
- Easy and fast installation using the optional
Refrigerant dryer
filter supports and by pass option (CDX 4-18) The inlet air of a compressor contains humidity and contaminants
like dust, oil, etc. During the compression these contaminants
Solid quality reach a high concentration. This can cause wear and corrosion
- High reliability was a key driver when to the downstream equipment, with potential costly interruption
developing the CDX dryer range to production and reduction in the efficiency and service life of the
- First-class components tested under extreme equipment used.
operating conditions
- Constant dewpoint under any load conditions By cooling down the compressed air, a refrigerant dryer removes
the largest part of the water content. Our CDX range ensures
Easy maintenance and accessibility high quality dry air, increasing efficiency and productivity as well as
the life span of your equipment and tools.
- Low maintenance level
- Reliable components easily accessible
The benefit of
- Long service intervals
Costs saving
- Very little maintenance required refrigerant dryers
- Low energy consumption
Clean and dry air
- Energy savings due to low pressure drops
- Increase your overall productivity
- No loss of compressed air due to
- Improve your final product quality
level-controlled condensate drain
- Protect your downstream equipment against
corrosion, rust and leakages.
- Avoid costly service interventions
Environmental friendly refrigerant gases
A key objective in the design of the CDX dryer • No impact on the ozone layer.
was to deliver a product that offers performance, • R410A benefits:
reliability and safety with the lowest possible - Low Global Warming Potential (GWP)
environmental impact. - Energy saving with rotary refrigerant
• Environmentally friendly thanks to the use of compressor (20 to 30% more efficient then
R513A, R410A and R452A gas. the conventional piston)
The smart choice for high reliability
1. REFRIGERANT COMPRESSOR 6. CONDENSATE SEPARATOR
driven by an electric motor, cooled for efficient condensate removal. 4
using refrigerant fluid and protected
against thermal overload. 7. HOT GAS BYPASS VALVE 5
controls the refrigerant capacity
2. REFRIGERANT CONDENSER under all load conditions. 6
air-cooled and with a large exchange
7
surface for high thermal exchange. 8. AUTOMATIC DISCHARGE OF
CONDENSATE energy saving and
3. MOTOR-DRIVEN FAN for the self adjusting, allows only moisture
condenser cooling air flow. to discharge and prevents waste
discharge of valuable compressed air. 3
4. AIR-AIR EXCHANGER with
high thermal performance and low
pressure drop. 8 1
2
5. AIR/REFRIGERANT
EVAPORATOR with high thermal
performance and low pressure drop.
4 5
AIR OUTLET
AIR INLET
15
16 6 19
12
7 14
9
11 8
13 17
10
1 18
3 CONDENSATE
DRAIN
DRYING PRINCIPLE
DIAGRAM FOR CDX 240
1. Refrigerant fluid compressor 7. Refrigerant fluid separator 14. Capillary Tube
2. Condenser 8. Maximum pressure switch 15. Service valve
3. Motor driven fan 9. Service valve 16. Dewpoint thermometer
4. Air/air heat exchanger 10. Minimum pressure switch 17. Impurity collector
5. Air/Refrigerant Evaporator 11. Fan pressure switch 18. Automatic discharge of condensate
6. Condensate separator 12. Hot gas bypass valve 19. PDP indicator
with a demister filter 13. Refrigerant fluid filter
CDX 4-840 Refrigerant Dryers
Technical data
According to ISO 7183:2007 and Cagi Pneurop PN8NTC2
Max. Working Air Treatment Capacity Motor Inlet/outlet Dimensions Weight
Pressure power Connections
Model Bar PSI lt/min. m3/h cfm W V/Hz/Ph gas/DN A B C Kg. Refrigerant
gas
CDX 4 16 232 350 21 12,4 130 230/50/1 3/4" M 493 350 450 19 R513A
CDX 6 16 232 600 36 21,2 164 230/50/1 3/4" M 493 350 450 19 R513A
CDX 9 16 232 850 51 30,0 190 230/50/1 3/4" M 493 350 450 20 R513A
CDX 12 16 232 1200 72 42,4 266 230/50/1 3/4" M 493 350 450 25 R513A
CDX 18 16 232 1825 110 64,4 284 230/50/1 3/4" M 493 350 450 27 R513A
CDX 24 14 203 2350 141 83,0 674 230/50/1 1" F 497 370 764 44 R513A
CDX 30 14 203 3000 180 106 716 230/50/1 1" F 497 370 764 44 R513A
CDX 36 14 203 3600 216 127 631 230/50/1 1" 1/2 F 557 460 789 62 R410A
CDX 41 14 203 4100 246 145 705 230/50/1 1" 1/2 F 557 460 789 60 R410A
CDX 52 14 203 5200 312 184 905 230/50/1 1" 1/2 F 557 460 789 62 R410A
CDX 65 14 203 6500 390 230 969 230/50/1 1" 1/2 F 587 580 899 82 R410A
CDX 77 14 203 7700 462 272 1124 230/50/1 1" 1/2 F 587 580 899 82 R410A
CDX 100 14 203 10000 600 353 1540 400/50/3 2" F 1070 805 962 145 R410A
CDX 120 14 203 12000 720 424 1980 400/50/3 2" F 1070 805 962 158 R410A
CDX 150 14 203 15000 900 530 2010 400/50/3 2” 1/2 F 1070 805 962 165 R410A
CDX 180 14 203 18000 1080 636 2770 400/50/3 2” 1/2 F 1070 805 962 164 R410A
CDX 240 14 203 24000 1440 848 3260 400/50/3 3" F 1083 1020 1526 325 R410A
CDX 300 14 203 30000 1800 1060 3890 400/50/3 3" F 1083 1020 1526 335 R410A
CDX 350 14 203 35000 2100 1237 4750 400/50/3 3" F 1083 1020 1526 350 R410A
CDX 450 14 203 45000 2700 1589 6715 400/50/3 DN 125 1121 1020 1526 380 R452A
CDX 500 14 203 50000 3000 1766 6800 400/50/3 DN 125 2099 1020 1535 550 R452A
CDX 700 14 203 70000 4200 2472 10200 400/50/3 DN 125 2099 1020 1535 600 R452A
CDX 840 14 203 84000 5040 2966 12300 400/50/3 DN 125 2099 1020 1535 650 R452A
NOTES:
Reference conditions: Operating limit conditions: Optional for CDX (4-18):
- Operating pressure: 7 bar (100 psi) - Max. operating pressure: 16 bar (232 psi) CDX 4-18 - Bypass + filter support
- Operating temperature: 35°C 14 bar (203 psi) CDX 24-840 - Filter support C
- Room temperature: 25°C - Max. inlet temperature: 55°C
- Pressure dewpoint: +4°C +/-1 (60°C for CDX 100-840)
- Available in different voltages - Min./Max. ambient temperature: +5°C; 43°C
and frequencies (+5°C; 46°C for CDX 100-840)
A
Correction factor for conditions differing from the project K = A x B x C B
°C 25 30 35 40 43 46 °C 30 35 40 45 50 55 60
Room Operating
1,00 0,92 0,84 0,80 0,79 / (CDX 4-77) 1,24 1,00 0,82 0,69 0,58 0,45 / (CDX 4-77)
temperature A temperature B
1,00 0,91 0,81 0,72 / 0,62 (CDX 100-840) 1,00 1,00 0,82 0,69 0,58 0,49 0,42 (CDX 100-840)
bar 5 6 7 8 9 10 11 12 13 14 15 16
Operating The new flow rate value can be obtained
0,90 0,96 1,00 1,03 1,06 1,08 1,10 1,12 1,13 1,15 1,16 1,17 (CDX 4-77) by dividing the current or real flow rate
Pressure C by the correction factor related to the
0,90 0,97 1,00 1,03 1,05 1,07 1,09 1,11 1,12 1,15 (CDX 100-840)
real operation conditions.
Typical installations Compressor
1
with after cooler
2 3 2 High quality
3 air with
2 3 2 3 G filter 2
4 4 C filter 3
High quality air with reduced dew point
V filter 4
reduced dew point 1 1 and oil concentration
1 1 Refrigerant
5
(air purity to (air purity to dryer
ISO 8573-1: 5 ISO 8573-1:
5 5 5
Vertical receiver
class 1:4:2) class 1:4:1) is always suggested
Product features and options
PDP Indicator
The operation of the CDX dryer is monitored by an electronic
controller indicating all relevant information:
Technical details: Alarm display:
- Status of the refrigerant dryer - High or low dew point
- Status of the fan - Fan probe failure (CDX12-77)
- Dew point indication - Service reminder
Potential free contact
(CDX 24-77) (CDX 100-840)
- PDP alarm - General alarm - Drain alarm
- High refrigerant temperature - High/low PDP alarm - Remote start/stop
- Fan probe failure - High-refrigerant temperature
- Probe failures
- High-pressure switch
- Electrical failure
Intelligent drain Available options
discharge (for CDX 4-18)
The full refrigerant dryer range is equipped with a level- Filter support and bypass*
controlled condensate drain, a range using electronic The optional bypass allows the system to operate using the
sensors to discharge only condensate and without filters only during maintenance or malfunction of the dryer, thus
wasting any compressed air. avoiding any downtime.
Benefits Filter support*
- No loss of compressed air This option allows two filters to be installed on the rear side of
- Energy saving the dryer, reducing overall dimensions and installation costs.
- Low noise level *Filters are not included in the option.
Contact your local representative:
6999100156
www.ceccato.com
CARE TRUST EFFICIENCY
Care is what service is Trust is earned by deliv- Equipment efficiency
all about: professional ering on our promises is ensured by regular
service by knowledgeable of reliable, uninterrupted maintenance. Efficiency
people, using high-quality performance and long of the service organiza-
original parts. equipment lifetime. tion is how Original
Parts and Service
make the difference.
© 2020, Ceccato. All rights reserved. All mentioned brands, product names, company names, trademarks and service
marks are the properties of their respective owners. Our products are constantly being developed and improved.
We thus reserve the right to modify product specifications without prior notice. Pictures are not contractually binding.