Content Warning...............................................................................1 1. Introduction......................................................................2 2. Application scope.............................................................2 3. Specifications...................................................................2 4. Principles and functions...................................................3 5. Installation and adjustment ..............................................3 6. Troubleshooting and Countermeasures ...........................7 7. Major technical parameters..............................................7 8. Maintenance and service..................................................8
Warning
When the ARD is used in combination with YASKAWA 676GL5-JJ or YASKAWA Varispeed-L7B transducer, turn off the power to ensure safe operation conditions, disconnect PO with B1 and NO of transducer with , remove the connecting wires between controlling cabinet PO and B1, and between NO and , and then connect PO and NO into the ARD. -
1. Introduction
SJTYY Elevator Automatic Rescue Device is applied to emergency running when the electric grid is in an abnormal state. When elevator stops between floors due to power failure, the ARD can supply power to allow the elevator to slowly land on the nearest floor and enable the door of the elevator to be opened automatically with the battery provided in the ARD, so as to let the passengers out safely. Through the coordination of the internal control circuit with transducer and microcomputer board, the ARD achieves automatic leveling function of elevators during power failure. Compared with similar traditional products, the ARD has the advantages of maximum utilization of the original resources of the control system, low price, high reliability and controlling flexibility.
2. Application scope
The ARD can be applied to the variable voltage & variable frequency elevator (VVVF elevator) driven by gearless permanent magnet synchronous motor or asynchronous motor.
3. Specifications
The specifications of the ARD are as followed:
SJT-YY
A: power of asynchronous motor 19KW, or synchronous motor12KW B: power of asynchronous motor 30KW, or synchronous motor 22KW G: Asynchronous Motor Type T: Synchronous Motor Type Blank: Standard Type I, II: Improved Type
Instructions PS1 and PS2 are input powers of the ARD, must be from one phase and neutral wire of the main power supply. AC220V15% (50HZ10%) is the power supply for the ARD and used to determine whether the electric grid is normal. Wires of 2mm2 are recommended. To separate the grounding terminal of braking voltage DC192V supplied by battery from the grounding terminal of the braking circuitonly for synchronous system. BS+ and BS- are the output power, DC192V, to supply power for transducer. Wires of 4mm2 are recommended. BK+ and BK- are the braking power output and the synchronous type adopts DC192V. Wires of 0.75mm2 are recommended. BK+ and BK- are output brake releasing signals. Contact output of contactor is used for locking KMC normally-open contact in braking circuit. Wires of 0.75mm2 are recommended. The output power supplied by the ARD is DC500V; to supply controlling power for transducer. P0 is passive and N0 is negative. (Connect wires according to this when YASKAWA 676GL5-JJ and Varispeed-L7B transducers are
Y5
BS+ BS-
Output power
TB1-1 TB1-2
BK+ BK-
Output power (only for synchronous type) Output brake releasing signal (only for asynchronous type ) Output power
CN1-3 CN1-14
CN1-3 CN1-14
P0 N0
adopted.)
CP1 CP2
Output power
CN1-4 CN1-15
IL1 IL2
CN1-7 CN1-17
IL3 IL4
IL5 IL6
Y3 Power failure CN1-20 COM3 output signal CN1-10 Y2 Y6 Power failure CN1-21 output signal CN1-13
5
CP1 and CP2 are the output controlling power AC220V10% (50HZ) provided by the ARD. Maximum power is 600W. To supply power for controlling circuit and electric circuit of door. Wires of 0.75mm2 are recommended. IL1 and IL2 supply interlock input and contact input of contactor for the ARD. They are used for the electric interlock of the ARD and elevator control system. IL3 and IL4 supply power interlock output and contact output of contactor for the control system, and is used to the electric interlock between the ARD and the control power of the control system. IL5 and IL6 supply interlock output and contact output of contactor for the control system, and is used to the electric interlock between the ARD and the control power of the control system. Contact output of contactor, and is used to lock the normally-open contact of phase sequence relay in safety circuit during power failure. Contact output of relay, and is used to supply input signal for microcomputer board. Used to supply input signal for transducer. COM2 is a shared
COM2
CN1-11
terminal, Y2 supplies the running signal of transducers battery and Y6 supplies transducer failure reset signal. used in certain transducers .
2. Wire connecting and adjustment a) Disconnect the air switches F1, F3, F4 (this air switch should be provided, if YASKAWA 676GL5-JJ and Varispeed-L7B transducers are equipped) and the rocker switch F2 F1, F2, F3 and F4 are stop switches of the ARD, and they are disconnected when they are delivered. b) Cut off the power supply to the elevator. c) Connect the separate terminals of the supplied cables with the control system according to the requirements and instructions of the wiring diagram and the above table. Disconnect CN1 terminals of the cable plug-ins with the ARD temporarily. Connect side power supply of the transducer with BS+ and BS- of the ARD by the supplied wire. If YASKAWA 676GL5-JJ and Varispeed-L7B transducers are provided, respectively connect P0 and N0 of controlling cabinet with P0 and N0 of the ARD by the supplied cables. d) Carefully check whether all the connecting wires are connected correctly. Incorrect connection may cause damage to either the ARD or the control system. e) After checking the connection, plug the cable plug-in in CN1, switch on the air switches F1, F3, F4 and the rocker switch F2, and then press the power switch of UPS to supply power to the elevator. f) If the elevator runs normally, then set the corresponding parameters of the transducer. g) Stop the elevator at the door zone of any floor and stop the power supply, then the elevator should be automatically opened at that time. h) Resume power supply to the elevator again, leave it between floors and stop power supply again, the elevator must move in the direction of light weight and opens at leveling when the emergency running conditions are met.
6
A asynchronous type19KW B asynchronous type30KW 7. Maximum running time: 2min 8. Cabinet dimensions: YB840*240*450 YC574*180*721