BROC Poroscope HV5-20-40 932-004 En-Uk
BROC Poroscope HV5-20-40 932-004 En-Uk
NEW
3 Instruments for
the Test Voltages:
• 0.8 - 5 kV
• 4 - 20 kV
• 8 - 40 kV
Display of the
Test Voltage
in the Test Head
Testing of the interior coating of a pipe with a rotating electrode on Testing of corrosion coatings on hulls
a rod system and the POROSCOPE®
Test method
b
POROSCOPE®
non-conductive
Coating material
a
c d
conductive, earthed .
carrier material
a) Test head b) Sweeper electrode c) Earth terminal d) Supply unit
The test method is based on the fact that all electri-
cally insulating coating materials have a much higher
dielectric strength than air. Instrument features
For testing, set the corresponding test voltage for the
Sturdy and handy instruments for rough appli-
coating thickness on the POROSCOPE. Alternatively, cations at construction sites or in production
you can also enter a testing standard and coating
Three versions with different test voltage
thickness. The POROSCOPE will then automatically ranges:
set the corresponding test voltage. You connect the HV5: 0.8 – 5 kV
specimen with the earth cable and move the electrode HV20: 4 – 20 kV
slowly over the surface to be tested. If the electrode HV40: 8 – 40 kV
passes a crack, a short voltage drop will occur – a
Maximum safety through high voltage genera-
sparkover. An optical and acoustic signal indicates tion in the test head
the pore, and the pore count is increased by one step.
Intuitive operation with menu navigation, rotary
button and illuminated display in the operator's
Safety field of vision
The POROSCOPE meets the safety
Comprehensive electrode selection for every
requirements of ISO 2746 as a result application
of the following features:
Continuously adjustable test voltage, electronic
test voltage monitoring, display of the test vol-
• Generation of the high voltage directly in the test tage present at the electrode
head; this eliminates the need for a high voltage
Optical and acoustic pore indication
cable that stores additional electrical charge and
Adjustable detection sensitivity
leads to a higher discharge current in the case of an
Also suitable for testing of electrostatically char-
electric shock. geable objects
• Automatic switch-off in the case of overloading.
Battery operation with Li-ion rechargeable bat-
• Insulated and earthed hand piece, therefore no elec- tery and smart battery technology: a controller
trostatic charging of the operator. permanently monitors the state charge of the
• Protective resistor that limits to the current to a safe battery and prevents deep discharge.
level.
• Push button for switching on the high voltage. The
high voltage is only present at the electrode as long Standards
as the push button is pressed. Testing in accordance with AS 3894.1, ASTM D4787,
ASTM D5162, ASTM G62, EN 14430, NACE SP0188,
NACE SP0490, NACE SP0274
3
Technical Data, Standard Content of Shipment,
Ordering Information
Ordering Information
e
a c
b
Overview of the various electrodes: a) Sweeper electrode b) Flat electrode c) Roller electrode d) Rotating electrodes for tests inside pipes
e) Circular ring electrode for tests on the outside walls of pipes
Selection table for flat, sweeper, circular ring and roller electrodes
5
Rotating Electrodes, Selection Table
Elastic spacer
Type Weight [g] Length [mm] Description Order no.
ZH9 145 160(6.3“) Avoids tilting when inserting into greater pipe depths 600-720
Ordering Examples
Example 1: Test system for testing Order no. Example 2: Test system for testing Order no.
enamel coatings interior pipe walls, for pipe
Test instrument POROSCOPE® HV40 604-521 inner diameter 80 mm
Sweeper electrode ZH6b 600-996 Test instrument POROSCOPE® HV40 604-521
Elastic spacer ZH9 600-720
2 x Rod system ZH8b 600-716
Centering device ZH4e 600-731
Thread reducer M8/M12 600-722
Rotating electrode ZH3e1 600-703
Pipe ID < 13 mm
Pipe ID ≥ 13 mm
Rotating Thread reducer Rod system Centering Rod system Elastic spacer
electrode M8/M5 ZH8a, b device ZH8a, b ZH9
ZH3a, ..., k M8/M12 ZH4a1, ..., g
7
FISCHER Worldwide
Helmut Fischer AG
CH-6331 Hünenberg, Switzerland Fischer do Brasil
Tel. +41 41 785 08 00 04561-001 São Paulo, Brazil
[email protected] Tel. +55 11 35 88 09 09
[email protected]
Fischer Instrumentation Electronique
78180 Montigny le Bretonneux, France Fischer Instruments K.K.
Tel. +33 1 30 58 00 58 Saitama-ken 340-0012, Japan
[email protected] Tel. +81 4 89 29 34 55
[email protected]
Helmut Fischer S.R.L.
20099 Sesto San Giovanni (Milano), Italy Nantong Fischer Instrumentation Ltd
Tel. +39 0 22 55 26 26 Shanghai 200333, P.R. China
[email protected] Tel. +86 21 32 51 31 31
[email protected]
Fischer Instruments, S.A.
08018 Barcelona, Spain Fischer Instrumentation (Far East) Ltd
Tel. +34 9 33 09 79 16 Kwai Chung, N.T., Hong Kong
[email protected] Tel. +852 24 20 11 00
[email protected]
Helmut Fischer Meettechniek B.V.
5627 GB Eindhoven, The Netherlands Fischer Measurement Technologies (India) Pvt. Ltd
Tel. +31 40 248 22 55 Pune 411036, India
[email protected] Tel. +91 20 26 82 20 65
[email protected]
09-12
Tel. +82 10 34 73 12 80
[email protected]
www.helmut-fischer.com