0% found this document useful (0 votes)
75 views2 pages

Technical Data Sheet - 125amp Satellite Synchronised Interrupter-2017

The document describes a 125 Amp Satellite-Synchronisable Interrupter and its accessories for pulsing cathodic protection systems. It utilizes a MOSFET switch rated at 2 x 180 Amps and can be synchronized via satellite signal. It has an ON/OFF switch and timing selector to control the pulsing sequence. Accessories include a satellite aerial, battery charger, and external battery cable to power the interrupter.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views2 pages

Technical Data Sheet - 125amp Satellite Synchronised Interrupter-2017

The document describes a 125 Amp Satellite-Synchronisable Interrupter and its accessories for pulsing cathodic protection systems. It utilizes a MOSFET switch rated at 2 x 180 Amps and can be synchronized via satellite signal. It has an ON/OFF switch and timing selector to control the pulsing sequence. Accessories include a satellite aerial, battery charger, and external battery cable to power the interrupter.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DC VOLTAGE GRADIENT

TECHNOLOGY & SUPPLY LTD


Design, Manufacturer and MARKET LEADERS IN ECDA SURVEY EQUIPMENT + SOFTWARE +
Exporter to 71 Countries CATHODIC PROTECTION RESEARCH
of Buried Pipeline
Inspection Equipment. Greenbank House Tel: +44 (0)1942 522180
36 Years Experience in Swan Lane, Hindley Green Fax: +44 (0)1942 522179
DCVG Technology
Wigan WN2 4AR E-Mail: [email protected]
United Kingdom Web Page: www.dcvg.com

Technical Data Sheet


125 Amp Satellite-Synchronisable Interrupter
Cat. No.: L0050SAT

❖ Equipment: 50amp Satellite-Synchronised Interrupter for pulsing the CP


System ON and OFF.
❖ Switch Type: Mosfet (Static).
❖ It utilizes a Metal Oxide Semiconductor Field Effect Transistor (MOSFET) rated
at 2 X 180 Amps, 200 volts DC to switch DC at one of five sequence speeds
determined by the position of the selection switch.
❖ Terminals: Differently Marked; Black / Red.
❖ Powered: 12V DC Battery.
❖ Synchronization: satellite aerial (external with cable connection).
❖ Knobs: ON/ OFF Switch and Timing selector switch
❖ Timing sequences: ON/ OFF 0.45/0.8S; 1.6/0.9S; 4/1S; 12/3S and 27/3S.
❖ LED light indicators: GPS synchronization, function ON/OFF and battery
charging.
❖ Connectors for: Aerial cable, battery charger on front panel.
❖ Accessories: - Satellite aerial with 3m connection cable.
❖ - Batteries charger 240AC/50Hz with cable connection suitable for
interrupter socket.
❖ Other Characteristics: Interrupter Box::
Dimension: 27 x 22 x 12.5 cm
Weight: 4.64kg 125amp Satellite
Rugged construction/ metal box plus heat sink to dissipate heat Synchronised
❖ Label: Type of equipment, serial no./ year of fabrication, producer (as per EN Interrupter
directive). Made in United Kingdom. Manufacturer Contact Details.
❖ Recommended operation 125amps.
❖ 12V Lead acid battery 4.5amps Hr.

. GPS Satellite Aerial

❖ Satellite aerial for logging on to the satellites. GPS sensor including embedded
receiver and antenna.
❖ Used to track multiple satellites at a time whilst providing fast time-to-first-fix, one
second navigation updates and low power consumption.
❖ This GPS sensor includes the capability of FAA Wide Area Augmentation System
(WAAS) differential GPS or RTCM corrections yielding submeter up to 3-5 metre
position accuracy.
❖ Designed to withstand rugged operating conditions and are waterproof to
IEC60529IPX7, immersion in 1 meter of water for 30mins.
❖ High accurate one pulse per second (PPS) output for precise timing and
measurements. Pulse width is configurable in 20-millisecond increments from 20ms to
980ms with 1ųs accuracy.
GPS Satellite Aerial

Company Registered in England and Wales No 2939265 Registered Office, 2 Bellwood, Westhoughton, Bolton, BL5 2RT. UK.
Page 1 of 2
120/2040V Battery Charger

❖ Battery charger comes in small black plastic box with a lead out either end.
❖ At rear of battery charger is cable for connection to mains electricity.
❖ At other end is black panel with the mains voltage range switch, 120 or 240V AC selection.
❖ Also a one ampere fuse for protection and red LED charging light.
❖ Low voltage cable at front of black panel that has a two pin plug to connecting to Interrupter for charging.

120/240V Battery Charger

Power Cable to External 12V Battery – External Battery Cable

❖ Sheathed black cable with one red and black croc clips to connect to external battery.
❖ Black/Silver connection end to plug into the Interrupter to power equipment up by an external battery like a car
battery.
❖ Once External battery cable is connected into interrupter it disconnects the internal interrupter battery so
interrupter is powered up by external car battery

External Battery Cable for Satellite Synchronized


Interrupter

Company Registered in England and Wales No 2939265 Registered Office, 2 Bellwood, Westhoughton, Bolton, BL5 2RT. UK.