This document summarizes the specifications of the Trivitron Healthcare MTV1000 portable ventilator. It lists the various parameters, modes, alarms, indicators, requirements and physical characteristics of the ventilator. The ventilator offers multiple modes of ventilation including PACV, PSIMV, VACV, VSIMV, SPONT+/CPAP, PRVC and auto modes. It has a 7-inch color touchscreen, built-in oxygen blender, 3 hours battery backup and optional modules for SpO2, ETCO2 and proximal pressure monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views2 pages

14799669609MTV1000 Brochure V.2.1

This document summarizes the specifications of the Trivitron Healthcare MTV1000 portable ventilator. It lists the various parameters, modes, alarms, indicators, requirements and physical characteristics of the ventilator. The ventilator offers multiple modes of ventilation including PACV, PSIMV, VACV, VSIMV, SPONT+/CPAP, PRVC and auto modes. It has a 7-inch color touchscreen, built-in oxygen blender, 3 hours battery backup and optional modules for SpO2, ETCO2 and proximal pressure monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Display Data

www.trivitron.com
Parameters : Setting parameters/Monitored parameters/Alarm status/I:E ratio
Graphic Waveform : Pressure-Time, Flow-Time, Volume-Time
Loop : Pressure-volume, Flow-volume, Pressure-flow
Alarm : Airway pressure , Tidal volume , Minute volume, Respiratory rate
Apnea, O2%, Airway leak, Circuit open, Battery indicator
O2 supply pressure failure, Ventilator in-operative
Key Indicators
Nebulizer : 10 to 180 minute
Inspiration hold : Measures patient's lung compliance and resistance
Elasticity, Time constant
Key lock : Key & LCD Touch Screen Lock
Graph freeze
Alarm silence : Mutes audible alarms for 2 minutes
Alarm reset : Clears visual indicators and messages

Electrical Requirements
Power : AC : 100-240 VAC, 50/60 Hz (Free voltage)
DC : 10.8V 8.8A, Internal battery
Provides Max. 180 minutes back up in normal operation
External DC Supply 12V ~ 16V
Physical Characteristics
Weight : 8 kg (main unit)
Dimensions : 25 x 15.6 x 37.1 (Width x Depth x Height) cm

Environmental Requirements
Storage - Temperature : -10 ~ 45℃ ( 15 ~ 110℉)
Relative humidity : 10 to 85 %
Operation : 10 to 40 ℃ (50 ~ 104 ℉)

Pneumatic Requirements
Oxygen inlet supply pressure : 2.4 to 6.2 bar (35 to 90 psi)

MTV1000
Head Office : # 15, IV Street, Abhiramapuram, Chennai -18. Ph : +91 44 24985050 (6 lines)
Fax : +91 44 24985757 / 24672782 ,[email protected]
Portable ICU Ventilator
Regional Offices : BANGALORE (+91 8022115491) | DELHI (+91 11 41354650)
“Extreme flexibility without compromising places and quality of care with ease”
KOLKATA (+91 33 24224493)|MUMBAI (+91 22 66612526 / 27 / 28)
Branch Offices : Chandigarh, Cochin, Coimbatore, Jaipur, Nagpur, Pondicherry & Pune Certified ISO 9001:2004 Company
International Offices : UAE, Oman, Sri Lanka, Seychelles, Maldives, Mauritius, Bangladesh & Nepal

www.trivitron.com +91 - 98400 80008 (24 Hour Helpline)


(CE 0470, KFDA, IS013485, IS09001)
/Trivitronindia /Trivitronindia /company/trivitron-healthcare /TrivitronHealthcare
MTV1000 SPECIFICATIONS*
Fully Featured Ventilator - Multi Purpose, Compact, Portability 7" Color TFT, Touch Screen & Knob
MTV1000 Offer innovated convenience Unique technology with high performance Affordable and Reliable O2 Blender, Exhalation Drive Line Outlet
Ventilators with Compliance to International Quality Standards Mode : PACV, PSIMV,VACV, VSIMV, Spont+/CPAP, PRVC, Auto
Apnea Back-up ventilation
Leak Compensation Upto 20lpm
(Optional) : SpO2, EtCO2
Proximal Pressure Monitoring.
Pneumatic Nebulizer with high Pressure O2 Source

Ventilator Data
Predicted Body weight : 10 to 150kg (Volume)
1 to 150kg (Pressure)
Tidal Volume : 50 to 2500 ml
Inspiratory pressure : 5 to 80 cmH2O (Peep+Pins <100cmH2O)
Pressure support : 0 to 60 cmH2O( Peep+PSV < 100cmH2O)
PEEP/CPAP : 0 to 45 cmH2O
Respiratory rate : 2 to 60 bpm
MTV1000 Highlights Inspiratory time : 0.3 to 4 sec
Rise Time ( in PCV ) : Fast, Medium, Slow
 Multi Purpose Ventilator (Home-Care, Ambulance, ER, ICU) Apnea Time : 2 to 60 sec
 7" Color TFT, Touch Screen & Knob Apnea BackUp Type : PACV , VACV Mode
 Built in Ultra Quite Turbine Technology Enable inhalation trigger(En-sense) : 10 to 80% of Inhalated volume
 3 Hours Battery Backup as Standard Feature Exhalation trigger Sensitivity(Ex-trig) : 10 to 80% of peak flow in exhalation.
 Easy to Maintain with Lab Viewer Program Inspiratory Pressure limit : 5 to 80 cmH2O in PRVC
 High pressure Oxygen and Low Flow Oxygen Trigger Type : Pressure and Flow
 Built in Electronic Blender Trigger sensitivity : Pressure trigger OFF, 0.5 to 20 cmH2O
 NIV /Mask ON/OFF in All Modes Flow trigger OFF, 0.5 to 20 lpm

Modes : PACV, PSIMV,VACV, VSIMV, SPONT+PS/CPAP, Auto, PRVC ,Smart Apnea Back up FiO2% : 21% to 100%
Nebulizer (time) : 10min to 180min(3 Hours)
Optional* : SpO2 / ETCO2, Proximal Pressure Monitoring, Nebulizer Sound Vol : 10% to 100%
With Additional Battery : Over 6 hours Back up O2 Sensor : ON(Enable) , OFF( Disable)
Limb Type : Dual , Single limb with External Peep Valve System
Altitude Volume Compensated : -100 to 5000 [m]
Room Air Temperature : 0 ~ 50℃
BTPS : OFF, MANUAL DRY, MANUAL HUMIDI
Mask : ON / OFF, compensated flow 20lpm Max

CERTIFIED

*Please note: Product specifications are subject to change without prior notice owing to product modifications, improvements / up-gradation.