Diferensial Pressure Gate
Diferensial Pressure Gate
Model F5503
Max. static pressure 100 bar
Nominal size 100 mm or 160 mm
Accuracy: Class 1,6 (EN), optional 1 %
Features
• Stainless steel case and wetted parts
• Static pressure 100 bar, one side load permitted
• Protection IP65, optional IP66
• Chamber purge and bleed connection
• High corrosive resistance
• Dry or liquid filled
• Dual diaphragm, safety design as solid front
Ranges
0 ... 40 mbar up to 0 ... 40 bar
Applications
Chemical and petrochemical industry
Machine and apparatus construction
Food and beverage industry
Pulp and paper industry
Technical specification F5503
Dial size in mm 100 160
All Construction Cylindrical case
Zero adjustment Externally, at the top of the case
sp
Measuring principle Dual diaphragm (principle see back side), safety design similar to solid front
eci Range in mbar 40 60 100 160 250 400
fic in bar 0,6 1 1,6 2,5 4 6 10 16 25 40
Max. static pressure 100 bar
ati Overload capability Static pressure is also maximum pressure allowed on one side
on Pressure type Differential
Process connection Flange for direct mounted manifolds similar to DIN EN 61518 with G ½ female
s G ¼ B male, G ¼ female, G ½ B male,
¼ NPT male, ¼ NPT female, ½ NPT male, ½ NPT female, others on request
Purge and bleed connection On top of both pressure chambers, G⅛ female with plug
Connection location Lower
Material
Pressure connection
Pressure chamber Stainless steel 316L (1.4404), optional Hastelloy C-276
Measuring diaphragm Stainless steel 316L (1.4404), optional Hastelloy C-276, Viton O-ring, Teflon on request
≤ 400 mbar stainless steel 316Ti (1.4571), optional Hastelloy C276
> 400 mbar Duratherm 2.4781 (NiCrCo alloy), 40 bar Inconel 718 (2.4668),
optional Hastelloy C 276 (ranges ≥ 4 bar with Hastelloy foil, not suitable for vacuum, only with accuracy
Case/bayonet ring class 1.6 (EN)) or Monel
Window Stainless steel 304 (1.4301), optional 316L (1.4404)
Dial Laminated safety glass
Pointer Aluminum, black markings on white background
Aluminum, black, optional red set hand or maximum pointer
Accuracy Class 1,6 (1,6 % F.S.), optional 1 % or 0,5 % according to ASME B40.1 unidirectional
Permissible -20 ... 80 °C, optional ATEX -20 ... 60 °C
Ambient temperature Max. 85 °C
Medium temperature -40 ... 70 °C
Storage temperature Max. 0,3 % / 10 K
Effectaccording to RL 2014/34/EU
Conformity
appendix X for mechanical equipment
in potential hazardous areas Optional, Marking
File no. 35106158 at notified body 0044, TÜV NORD CERT
Protection according EN 60 529/IEC 529 IP65, optional IP66 / NEMA 4X (only for option LJ or liquid filled cases)
Filling liquids Glycerin, silicone, others on request
Mounting Direct, optional wall or 2" pipe mounting (not for ranges ≤ 400 mbar), others on request
Weight dry/filled in kg 9/9,5 9,4/10
≤ 400 mbar 4/4,5 4,5/5
Accessories, options≥ 600 mbar 3 or 5 way remote or direct mounted manifolds, gauges with contacts (see data sheet G1.K55/E),
diaphragm seals, NACE/ISO 15156
ar
e subject to change without notice. G1.F5503/E Rev.
U 10/2019
General dimensions in mm
Order information
Order
Size example
System Execution Process Connection Range Engineer- Filling and Options
Size Type System Execution
material material
connection Process orientation
Connection Range
ing unit Engineering
contacts Filling/
connection orientation unit contacts
(100) (S) Pressure (=) Dry (27) G ¼ female (L) Lower 0/ 40 (MBAR) (=) Standard (NH) Tagging wired
100 mm chamber case 0/ 60 no filling (6B) Cleaned for Oxygen
316L (1.4404) (02) ¼ NPT male 0/ 100
(GV) Silicone service
(160) Diaphragm (L) Liquid (04) ½ NPT male (suitable for (body filled with halocarbon)
160 mm filled inadmissible for static
≤ 400 mbar 0/ 160 inductive
(13) G ¼ B male contacts)
pressure ≤ 40 bar
316Ti (1.4571), (YW) Case material 316L
> 400 mbar (15) G ½ B male 0/ 250
(BAR) (GT) Napvis (1.4404)
Duratherm, (25) ¼ NPT female (suitable for (PT) PTFE gasket
40 bar Inconel (50) ½ NPT female 0/ 400 magnetic
(AN) Accuracy class 1 1) 2)
spring
chamber 0/ 0,6 contacts) (AJ) Accuracy 0,5% 1) 2)
(51) G ½ female
316L (1.4404) 0/ 1 (GR) Glycerin (CS) Dual scale
and flange for
Diaphragm direct mount- 0/ 1,6 (DA) Dial marking
( ) Contact
Hastelloy C276 ed valves 0/ 2,5 (FW) Wall mounting bracket
type and
(HH) Pressure 0/ 4 function (TM) 2" pipe mounting
chamber and 0/ 6 (see data bracket
diaphragm 0/ 10 sheet
G1.K55/E) (LJ) Field fillable
Hastelloy C276 0/ 16 (only for execution =)
0/ 25
(ATEX) ATEX listed
(SM) Pressure 0/ 40
(C3) Material certificate
chamber acc. to EN 10204 3.1
316L (1.4404)
Diaphragm (C4) Individual 4-point
Monel calibration certificate
(only ranges
≥ 0,6 bar) 1)
inadmissible with electrical
contact options
2)
inadmissible for ranges ≥ 4
bar with Hastelloy C dia-
phragm
compound
ranges
on request
Option