0% found this document useful (0 votes)
62 views

Single-Phase On-Grid String Inverter: Features

The document summarizes the technical specifications of six single-phase on-grid string inverters from SPI3000-B2 to SPI6000-B2. The inverters feature high efficiency from 98.1% to 98.3%, safe and reliable design with IP65 rating and full lightning protection, and intelligent monitoring through cloud platform and communication methods. They also offer green energy savings with compact size, natural cooling, and wide operating temperature range from -40°C to 60°C.

Uploaded by

Jadson Raphael
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views

Single-Phase On-Grid String Inverter: Features

The document summarizes the technical specifications of six single-phase on-grid string inverters from SPI3000-B2 to SPI6000-B2. The inverters feature high efficiency from 98.1% to 98.3%, safe and reliable design with IP65 rating and full lightning protection, and intelligent monitoring through cloud platform and communication methods. They also offer green energy savings with compact size, natural cooling, and wide operating temperature range from -40°C to 60°C.

Uploaded by

Jadson Raphael
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

2-2

Single-phase On-grid String Inverter


SPI3000-B2/SPI3600-B2/SPI4000-B2/SPI4600-B2/SPI5000-B2/SPI6000-B2

Features
High-efficiency
• High-efficiency inverter topology ensures annual power
generation
• Advanced control algorithms and high adaptation ability to
the grid, improving the stability of power generation system

Safe and Reliable


• IP65 for outdoor application
• Integrated AC/DC full lightning protection
• Aluminum alloy die-casting integrated chassis, ensure 25
years full life circle running

Intelligent Management
• Intelligent cloud platform monitoring, realizing one- key APP
real-time monitoring
• Support RS485, GPRS, WIFI and other communication
methods

Green Saving
• Small size, easy to install and use
• Natural cooling, ensuring low environmental noise
• Super-wide operating temperature range, adapt to extremely
cold, high temperature areas

Function Diagram

10
Products

Technical Specifications
Items SPI3000-B2 SPI3600-B2 SPI4000-B2 SPI4600-B2 SPI5000-B2 SPI6000-B2

DC Input
Max. PV input voltage 600Vdc
Rated PV voltage 360Vdc
Max. PV input current 22A (2×11A)
No. of MPPTs 2
No.of PV strings per MPPT 1/1
MPPT voltage range 100Vdc~500Vdc
Starting voltage 120Vdc
AC Output
Rated AC output power 3.0kW 3.6kW 4.0kW 4.6kW 5.0kW 6.0kW
Max. output power 3.3kW 3.96kW 4.4kW 5.06kW 5.5kW 6.0kW
Rated AC output voltage 220V/230Vac
Rated output current 13.0A 15.7A 17.4A 20.0A 21.7A 26.0A
Max. output current 14.3A 17.2 A 19.1A 22.0 A 23.9 A 26.0 A
Rated grid frequency 50/60Hz
Grid frequency range 45~55Hz/55~65Hz
Power factor >0.99 full load
PF adjustable range 0.8 (leading)~0.8 (lagging)
THDI <3% (rated power)
Efficiency
Max. efficiency 98.1% 98.3%
European efficiency 97.7% 97.9%
Protection
Anti-islanding Yes
DC reversed connection Yes
AC short circuit protection Yes
Temperature protection Yes
Surge protection Yes
PV fault detect Yes
DC Switch Optional
General
Dimensions (W×H×D) 360×420×125 mm
Weight 12.6kg
IP grade IP65
Noise level ≤25 dB
Night power consumption <1W
Cooling type Natural cooling
Altitude 4000m (>2000m derating)
Operating temperature -40ºC~60ºC (>45ºC derating)
Relative humidity 0~95%
Display LCD display + LED indicator
Communication RS485/WiFi (optional)/GPRS (optional)/DRM (Australia)
DC terminal MC4 Terminal
AC terminal Plug and play connector
Installation method Wall-mounted
EN62109-1, EN62109-2 NB/T32004, AS3100, AS4777, EN 61000-6-2, EN 61000-6-3 , IEC 62116:2014
Standard
,IEC 61727:2004 ,IEC 60068-2-1:2007 ,IEC 60068-2-2:2007 ,IEC 60068-2-14:2009 ,IEC 60068-2-30:2005
*Specifications are subject to change without prior notice.