Terminales Panduit LCAS

This document provides an overview of Code Conductor One-Hole Short Barrel lugs with inspection windows for use with stranded copper conductors. It lists the various part numbers, dimensions, conductor sizes compatible, color codes, crimping die information, temperature ratings, certifications and package quantities. The lugs are designed for limited space applications and feature an inspection window to check proper conductor insertion and tin plating to inhibit corrosion.

Uploaded by

francisco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views2 pages

Terminales Panduit LCAS

This document provides an overview of Code Conductor One-Hole Short Barrel lugs with inspection windows for use with stranded copper conductors. It lists the various part numbers, dimensions, conductor sizes compatible, color codes, crimping die information, temperature ratings, certifications and package quantities. The lugs are designed for limited space applications and feature an inspection window to check proper conductor insertion and tin plating to inhibit corrosion.

Uploaded by

francisco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ELECTRICAL SOLUTIONS

A.
System
Overview

Code Conductor, One-Hole, Short Barrel with Window Lug


B1.
Cable Ties
For Use with Stranded Copper Conductors
Type LCAS
B2.
• Short barrel for limited space applications • UL Listed and CSA Certified to 35 KV** and temperature rated to Cable
• Color-coded barrels marked with Panduit and specified competitor 90°C when crimped with Panduit and specified competitor Accessories
die index numbers for proper crimp die selection crimping tools and dies
• Inspection window to visually assure full conductor insertion • Tested by Telcordia – meets NEBS Level 3
• American Bureau of Shipping approved B3.
• Tin-plated to inhibit corrosion Stainless
Steel Ties

C1.
W Wiring
Duct

L
C2.
Surface
B Raceway
INSPECTION
WINDOW
C3.
T Abrasion
Protection
Copper Stud Hole Figure Dimensions Panduit Panduit Burndy T&B Wire Strip Std.
Conductor Size (In.) Color Die Index Die Index Die Index Length Pkg.
Part Number Size (In.) W B T L Code No.‡ No.‡ No.‡ (In.) Qty. C4.
Cable
LCAS8-10-L #10 0.41 0.42 0.08 1.11 Red P21 49 21 1/2 50 Management
LCAS8-14-L 1/4 0.48 0.42 0.07 1.20 Red P21 49 21 1/2 50
#8 AWG
LCAS8-56-L 5/16 0.56 0.42 0.05 1.32 Red P21 49 21 1/2 50
LCAS8-38-L 3/8 0.60 0.42 0.05 1.42 Red P21 49 21 1/2 50
D1.
Terminals
LCAS6-10-L #10 0.45 0.48 0.09 1.19 Blue P24 7 24 9/16 50
LCAS6-14-L 1/4 0.48 0.48 0.08 1.28 Blue P24 7 24 9/16 50
#6 AWG D2.
LCAS6-56-L 5/16 0.56 0.48 0.07 1.40 Blue P24 7 24 9/16 50
Power
LCAS6-38-L 3/8 0.62 0.48 0.06 1.50 Blue P24 7 24 9/16 50 Connectors
LCAS4-10-L #10 0.55 0.53 0.09 1.26 Gray P29 8 29 5/8 50
LCAS4-14-L 1/4 0.55 0.53 0.09 1.35 Gray P29 8 29 5/8 50
#4 AWG D3.
LCAS4-56-L 5/16 0.55 0.53 0.09 1.47 Gray P29 8 29 5/8 50 Grounding
LCAS4-38-L 3/8 0.62 0.53 0.07 1.57 Gray P29 8 29 5/8 50 Connectors

LCAS2-14-Q 1/4 0.60 0.57 0.10 1.46 Brown P33 10 33 5/8 25


LCAS2-56-Q 5/16 0.66 0.57 0.10 1.58 Brown P33 10 33 5/8 25 E1.
#2 AWG Labeling
LCAS2-38-Q 3/8 0.66 0.57 0.10 1.66 Brown P33 10 33 5/8 25 Systems
LCAS2-12-Q 1/2 0.75 0.57 0.08 1.89 Brown P33 10 33 5/8 25
LCAS1-14-E 1/4 0.70 0.59 0.11 1.50 Green P37 11 37 11/16 20
LCAS1-56-E 5/16 0.70 0.59 0.11 1.63 Green P37 11 37 11/16 20
E2.
#1 AWG Labels
LCAS1-38-E 3/8 0.70 0.59 0.11 1.70 Green P37 11 37 11/16 20
LCAS1-12-E 1/2 0.75 0.59 0.09 1.94 Green P37 11 37 11/16 20
E3.
LCAS1/0-14-X 1/4 0.76 0.66 0.12 1.67 Pink P42 12 42 3/4 10 Pre-Printed
LCAS1/0-56-X 5/16 0.76 0.66 0.12 1.72 Pink P42 12 42 3/4 10 & Write-On
1/0 AWG Markers
LCAS1/0-38-X 3/8 0.76 0.66 0.12 1.80 Pink P42 12 42 3/4 10
LCAS1/0-12-X 1/2 0.80 0.66 0.12 2.03 Pink P42 12 42 3/4 10
E4.
LCAS2/0-14-X 1/4 0.85 0.72 0.13 1.82 Black P45 13 45 3/4 10 Permanent
Identification
LCAS2/0-56-X 5/16 0.85 0.72 0.13 1.82 Black P45 13 45 3/4 10
2/0 AWG
LCAS2/0-38-X 3/8 0.85 0.72 0.13 1.89 Black P45 13 45 3/4 10 E5.
LCAS2/0-12-X 1/2 0.85 0.72 0.13 2.14 Black P45 13 45 3/4 10 Lockout/
Tagout
‡See pages D3.56, D3.57 for tool and die information. & Safety
Solutions
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.

F.
Table continues on page D2.8 Index

For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)

Downloaded from Arrow.com.


ELECTRICAL SOLUTIONS
A.
System
Overview

Code Conductor, One-Hole, Short Barrel with Window Lug (continued)


B1.
Cable Ties
Copper Stud Hole Figure Dimensions Panduit Panduit Burndy T&B Wire Strip Std.
Conductor Size (In.) Color Die Index Die Index Die Index Length Pkg.
B2. Part Number Size (In.) W B T L Code No.‡ No.‡ No.‡ (In.) Qty.
Cable LCAS3/0-14-X 1/4 0.96 0.83 0.13 1.97 Orange P50 14 50 7/8 10
Accessories
LCAS3/0-56-X 5/16 0.96 0.83 0.13 1.97 Orange P50 14 50 7/8 10
3/0 AWG
LCAS3/0-38-X 3/8 0.96 0.83 0.13 2.03 Orange P50 14 50 7/8 10
B3. LCAS3/0-12-X 1/2 0.96 0.83 0.13 2.28 Orange P50 14 50 7/8 10
Stainless
Steel Ties LCAS4/0-14-X 1/4 1.06 0.91 0.14 2.08 Purple P54 15 54 1 10
LCAS4/0-56-X 5/16 1.06 0.91 0.14 2.10 Purple P54 15 54 1 10
4/0 AWG
C1. LCAS4/0-38-X 3/8 1.06 0.91 0.14 2.17 Purple P54 15 54 1 10
Wiring LCAS4/0-12-X 1/2 1.06 0.91 0.14 2.40 Purple P54 15 54 1 10
Duct
LCAS250-14-X 1/4 1.17 1.03 0.14 2.25 Yellow P62 16 62 1 1/8 10
LCAS250-56-X 5/16 1.17 1.03 0.14 2.25 Yellow P62 16 62 1 1/8 10
C2. 250 kcmil
LCAS250-38-X 3/8 1.17 1.03 0.14 2.32 Yellow P62 16 62 1 1/8 10
Surface
Raceway LCAS250-12-X 1/2 1.17 1.03 0.14 2.56 Yellow P62 16 62 1 1/8 10

‡See pages D3.56, D3.57 for tool and die information.


C3. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
Abrasion
Protection

C4.
Cable
Management

D1.
Terminals

D2.
Power
Connectors

D3.
Grounding
Connectors

E1.
Labeling
Systems

E2.
Labels

E3.
Pre-Printed
& Write-On
Markers

E4.
Permanent
Identification

E5.
Lockout/
Tagout
& Safety
Solutions

F.
Index

Prime items appear in BOLD.

Downloaded from Arrow.com.

You might also like