0% found this document useful (0 votes)
104 views2 pages

Ficha Tecnica 2RB-820-7HH36

The document provides performance curves for a vacuum pump and compressor. It specifies the G-2RB type can operate as either a vacuum pump or compressor continuously over the stated performance curve ranges. Technical specifications are provided for multiple models of the 2RB820 type, including voltage ranges, frequencies, rated power, current, pressure differentials, sound levels, and weights. Other available voltage ranges and ATEX compliant models are also listed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views2 pages

Ficha Tecnica 2RB-820-7HH36

The document provides performance curves for a vacuum pump and compressor. It specifies the G-2RB type can operate as either a vacuum pump or compressor continuously over the stated performance curve ranges. Technical specifications are provided for multiple models of the 2RB820 type, including voltage ranges, frequencies, rated power, current, pressure differentials, sound levels, and weights. Other available voltage ranges and ATEX compliant models are also listed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

G-2RB 2RB 820

Performance curve for Vacuum pump Performance curve for Compressor

↑ ↑

suction capacity V (m³/h)


suction capacity V (m³/h)

mbar p total pressure difference (vacuum) total pressure difference (gauge) p mbar
← →
△ △

↑ ↑
on the pump shaft (kW)

on the pump shaft (kW)


power requirement P

power requirement P

mbar p total pressure difference (vacuum) total pressure difference (gauge) p mbar
← →
△ △

↑ ↑
temperature rise T (in K)

temperature rise T (in K)


on the air handled

on the air handled

mbar p total pressure difference (vacuum) total pressure difference (gauge) p mbar
← →
△ △

The performance curves are based on air at a temperature of 15 °C and an Each G-2RB type can be applied both as vacuum pump and compressor in
atmospheric pressure of 1013 mbar with a tolerance of +/- 10 %. continuous operation over the total stated performance curve range. The
The total pressure differences are valid for suction and ambient temperatures motors are available as standard for the input voltage range of 50 and 60 Hz
up to 25 °C. and for protection category IP 55 as well as approbated for UL and CSA.
For other conditions please confer with us.

Tel: (506) 2225-5435 Website: www.rdeing.com E-mail: [email protected]


Technical data sheet Edition 04/2010 En
Selection and ordering data
Type 2RB820
Curve Order No. Fre- Rated Input voltage Input Permissible total Sound Weight
No. quency power current differential pressure ²) pressure ca.
level ³)

Vacuum Compressor
Hz kW V A mbar mbar dB(A) kg

3~ 50/60 Hz IP55 isulation material class F 1)


A 350 2RB820-7HH17 50 5.5 345D ... 415D 600Y...720Y 13.3D 7.7 -240 240 74 83
A 351 2RB820-7HH17 60 6.3 380D ... 480D 660Y...720Y 13.3D 7.7 -170 160 78 83
A 352 2RB820-7HH27 50 7.5 345D ... 415D 600Y...720Y 16.7D 9.6 -400 400 74 86
A 353 2RB820-7HH27 60 8.6 380D ... 480D 660Y...720Y 17.3D 10.0 -360 330 78 86
A 354 2RB820-7HH37 50 11.0 345D ... 415D 600Y...720Y 28.0D 16.2 -430 600 74 104
A 355 2RB820-7HH37 60 12.6 380D ... 480D 660Y...720Y 29.0D 16.7 -460 600 78 104
A 356 2RB820-7HH47 50 15.0 345D ... 415D 600Y...720Y 32.5D 18.8 -460 670 74 120
A 357 2RB820-7HH47 60 17.3 380D ... 480D 660Y...720Y 34.5D 19.9 -490 750 78 120

Other voltage ranges


2RB 820-7HH □.□
50Hz 60Hz
↑↑
3
~
185...225 V D/320...390 V Y 200...240 V D/345...415 V Y H 1
200...240 V D/345...415 V Y 200...275 V D/380...480 V Y H 6
345...415 V D 380...480 V D H 7
500 V D 575VD C 5
Machines according to the ATEX norm 94/4 EG are available
for the whole performance range.
Following types available: Category 3 G, 3/2 G, 3 D and 3/2 D.
1
~
100 / 200 V 100 / 200 V V 4
115 / 230 V 115 / 230 V V 5
230V 230V A 1
Further voltage range on request; please quote in plain text.

All G-2RB achieve the standards and norms of the low voltage directive The motors are designed according to the DIN EN 60 034 / DIN IEC 34-1 and
(LVD)2006/95/EC, rotating electrotechnical motor EN 60034-1-2004, temperature class F.
electromagnetic compatibility(EMC)EN55014-1/2,EN61000-2/-3/-4/-6. For the three phase machines the tolerances are +/- 10 % for fixed voltage and
+/- 5 % for voltage range.
1) For standard UL for ELECTRIC MOTOR UL 1004-1. The single phase machines are designed with a +/- 5 % tolerances. If only 90 %
2) Relief-valve are available for limiting differential pressure. of the maxium allowed pressure will be used for the continuousoperating then the
3) Measuring-surface sound-pressure level acc. to DIN EN 21680, measured allowed voltage range add to +/- 10 %.
at a distance of 1 m. The pump is throttled to an average suction pressure, For all single and three phase machines which designed according to the UL and
a hose is connected to the discharge side (compressor) / suction side CSA norm (UL 1004-1) the maximum allowed voltage tolerances are - 10 % resp.
(vacuum pump), but is not fitted with relief valves. + 6 %.
The frequency tolerance is maximum +/- 2 %.

Changes in particular the quoted performance curve, datas and weights without prior notice. The figures are without obligations.

Tel: (506) 2225-5435 Website: www.rdeing.com E-mail: [email protected]