0% found this document useful (0 votes)
48 views

Connor Robot Advanced Version Datasheet

The Connor Robot Advanced Version is a disinfection robot that uses UV-C light and an atomizer fogger to disinfect surfaces. It is 50cm x 50cm x 135cm, weighs 70kg, and can cover 550 square meters in one hour on a single 8-hour battery charge. It has sensors such as LIDAR and cameras to navigate autonomously and avoid collisions. The robot is not a medical device and is intended only for disinfecting rooms and equipment, not for use directly on patients.

Uploaded by

mazen mm
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views

Connor Robot Advanced Version Datasheet

The Connor Robot Advanced Version is a disinfection robot that uses UV-C light and an atomizer fogger to disinfect surfaces. It is 50cm x 50cm x 135cm, weighs 70kg, and can cover 550 square meters in one hour on a single 8-hour battery charge. It has sensors such as LIDAR and cameras to navigate autonomously and avoid collisions. The robot is not a medical device and is intended only for disinfecting rooms and equipment, not for use directly on patients.

Uploaded by

mazen mm
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

technical specifications

Name Connor Robot Advanced Version


Type UVC

Designated use For disinfection purposes e.g. in hospital rooms or in laboratories.

dimensions
Length 50 cm 19.7 in
Width 50 cm 19.7 in
Height 135 cm 53 in
Weight 70 kg 154 lb

color
White
Grey

speed and performance


Maximum Speed 1 m/s 3.6 km/h or 2.23 mile /h
Turning Radius 520 mm 20 in around center of the robot

+/- 50 mm 2 in relative to position


Positioning Accuracy +/- 10 mm 2 in relative to docking station

Surface covered in 1 hour 550m2 5,920 sq ft

power
Battery Type DC, 48 V, 15 Ah
Charging Time With manual charger: up to 6 hours
With docking station: up to 6 hours
Operation Time >8 hours
Battery Cycle Times Minimum 1000 cycles

external charger
Input 100-240 V, AC 50-60 Hz

Output 48 V, DC Max 15 A

environment
Ambient Temperature Range - 10°C to 60°C + 14°F to 140°F humidity 10-95% non-condensing

Certifications CE Certified

communication
WiFi Dual-band wireless
Wireless Frequencies 2.4 GHz 802.11 b/g/n and 5 GHz 802.11 a/n/ac
I/Os USB and Ethernet

sensors

Light Detection and Ranging Sensor (LIDAR) Anti-Collision Sensors


Infrared Sensors Ultrasonic Sensor
3D Camera LED Touchscreen Display

SPRAY
Spraying Nozzles Five Units
Type Atomizer fogger

lamps
Type UV systems UV-C Wavelenght 254 nm
Power (Rated) (Nom) 90 W Depreciation at Useful Lifetime 15 %
Lamp Current (Nom) 2.1 A
WARNING
Ignition Supply Voltage (Min) 90 V The lamps emit high-power UVC light that can cause injury to skin and eyes. Use only
20,000 hours in enclosed environments which shields users from the light.
Lifetime

Declaration: The Connor UVC Robot is not classified as a Medical Device, as the intended use of the product is disinfection of infrastructure, furniture and ambient air in Healthcare environments.
The Connor UVC Robot is not intended to disinfect Medical Devices or in any way to be in direct contact with patients.