This document provides technical information about DOWLEXTM 2685G Polyethylene Resin, including its properties, testing results, and fabrication conditions for blown film. The resin exhibits good toughness and tear resistance and complies with various regulations. It has nominal values provided for density, melt index, film properties, thermal properties, and optical properties.

Uploaded by

tariquekhan143
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views4 pages

DoW LDPE 2685G

This document provides technical information about DOWLEXTM 2685G Polyethylene Resin, including its properties, testing results, and fabrication conditions for blown film. The resin exhibits good toughness and tear resistance and complies with various regulations. It has nominal values provided for density, melt index, film properties, thermal properties, and optical properties.

Uploaded by

tariquekhan143
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Technical Information

DOWLEX™ 2685G
Polyethylene Resin

Overview DOWLEX™ 2685G Linear Low Polyethylene Resin is designed for the production of a wide variety of film applications.
Films made from this resin exhibit a combination of good toughness and tear resistance.

Complies with:
• U.S. FDA FCN 741
• Canadian HPFB No Objection
• EU, No 10/2011
Consult the regulations for complete details.

Additive • Antiblock: 5100 ppm • Slip: 917 ppm • Processing Aid: No

Physical Nominal Value (English) Nominal Value (SI) Test Method


Density 0.920 g/cm³ 0.920 g/cm³ ASTM D792
Base Density 1 0.917 g/cm³ 0.917 g/cm³ Dow Method
Melt Index (190°C/2.16 kg) 0.75 g/10 min 0.75 g/10 min ASTM D1238
Films Nominal Value (English) Nominal Value (SI) Test Method
Film Thickness - Tested 1 mil 25 µm
Film Puncture Energy 41.0 in·lb 4.63 J
Film Puncture Force 14.0 lbf 62.3 N
Film Puncture Resistance 246 ft·lb/in³ 20.4 J/cm³
Film Toughness ASTM D882
MD 1610 ft·lb/in³ 133 J/cm³
TD 1600 ft·lb/in³ 132 J/cm³
Secant Modulus ASTM D882
1% Secant, MD 23300 psi 160 MPa
2% Secant, MD 19400 psi 133 MPa
1% Secant, TD 26500 psi 183 MPa
2% Secant, TD 21400 psi 147 MPa
Tensile Strength ASTM D882
MD : Yield 1630 psi 11.2 MPa
TD : Yield 1620 psi 11.2 MPa
MD : Break 8160 psi 56.3 MPa
TD : Break 6870 psi 47.3 MPa
Tensile Elongation ASTM D882
MD : Break 610 % 610 %
TD : Break 690 % 690 %
Dart Drop Impact 630 g 630 g ASTM D1709A
Elmendorf Tear Strength ASTM D1922
MD 400 g 400 g
TD 520 g 520 g
Thermal Nominal Value (English) Nominal Value (SI) Test Method
Vicat Softening Temperature 216 °F 102 °C ASTM D1525
Melting Temperature (DSC) 246 °F 119 °C Dow Method
Optical Nominal Value (English) Nominal Value (SI) Test Method
Gloss (45°) 47 47 ASTM D2457
Haze 16.0 % 16.0 % ASTM D1003

Form No. 400-00089026en


Page: 1 of 4 ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Rev: 2013-01-07
Extrusion Notes
Fabrication Conditions For Blown Film:
• Die Size: 8 in.
• Screw Type: DSB II
• Die Gap: 70 mil
• Melt Temperature: 437°F
• Output: 12 lb/hr/in. of die circumference
• Die Diameter: 8 in.
• Blow-Up Ratio: 2.5:1
• Screw Speed: 39 rpm
• Frost Line Height: 43 in.

Notes
These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests.
1Base density is estimated using the assumption that every 1000 ppm of antiblock in the finished product raises the density of the polymer
by 0.0006 g/cm³. Base density is the estimated density of the polymer if it did not contain any antiblock.

Form No. 400-00089026en


Page: 2 of 4 ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Rev: 2013-01-07
Product Dow has a fundamental concern for all who make, distribute, and use its products, and for the
Stewardship environment in which we live. This concern is the basis for our product stewardship philosophy by which
we assess the safety, health, and environmental information on our products and then take appropriate
steps to protect employee and public health and our environment. The success of our product stewardship
program rests with each and every individual involved with Dow products - from the initial concept and
research, to manufacture, use, sale, disposal, and recycle of each product.

Customer Dow strongly encourages its customers to review both their manufacturing processes and their
Notice applications of Dow products from the standpoint of human health and environmental quality to ensure
that Dow products are not used in ways for which they are not intended or tested. Dow personnel are
available to answer your questions and to provide reasonable technical support. Dow product literature,
including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets
are available from Dow.

Medical Any and all medical application use of Dow materials, whether a device, a component, or any type of
Applications primary or secondary packaging of a medically related object or substance, needs to be reviewed and
approved by Dow before any Dow material can be tested in such application.
Policy
Dow requests that customers considering use of Dow products in medical applications notify Dow so that
appropriate assessments may be conducted. Dow does not endorse or claim suitability of its products for
specific medical applications. It is the responsibility of the medical device or pharmaceutical manufacturer
to determine that the Dow product is safe, lawful, and technically suitable for the intended use. DOW
MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW
PRODUCT FOR USE IN MEDICAL APPLICATIONS.

For further information contact your Dow sales or technical representative to request a Medical Application
Review Request Form.
Additional details of Dow’s Medical Applications Policy are available at: https://www.dow.com/en-us/
support/product-safety.html

Tobacco and Dow does not support or intend for its products to be used, directly or indirectly, in the production of
Marijuana Policy tobacco, the manufacture of tobacco products, the manufacture and use of electronic cigarettes (including
vaping devices), the production of marijuana, or the manufacture of marijuana products intended for
human consumption, where the Dow product (or its residues) may be present in the finished product or be
alleged to facilitate the delivery of nicotine, other tobacco components, marijuana, or marijuana
components.

Harmful Dow does not intend for its products to be used in applications specifically intended to harm humans.
Applications
Policy

Disclaimer NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because
use conditions and applicable laws may differ from one location to another and may change with time, the
Customer is responsible for determining whether products and the information in this document are
appropriate for the Customer’s use and for ensuring that the Customer’s workplace and disposal practices
are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation
or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
EXPRESSLY EXCLUDED.

NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications may not be fully determined;
(2) analysis of hazards and caution in handling and use are required; (3) there is greater potential for Dow to change specifications
and/or discontinue production; and (4) although Dow may from time to time provide samples of such products, Dow is not obligated
to supply or otherwise commercialize such products for any use or application whatsoever.

NOTICE: This data is based on information Dow believes to be reliable, as demonstrated in controlled
laboratory testing. They are offered in good faith, but without guarantee, as conditions and method of use
of Dow products are beyond Dow’s control. Dow recommends that the prospective user determine the
suitability of these materials and suggestions before adopting them on a commercial scale.

To the best of our knowledge, the information contained herein is accurate and reliable as of the date of
publication, however we do not assume any liability for the accuracy and completeness of such
information.

For additional information, not covered by the content of this document, contact us via our web site http://
www.dow.com/products_services/.

Form No. 400-00089026en


Page: 3 of 4 ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Rev: 2013-01-07
Additional North America Europe/Middle East +800-3694-6367
Information U.S. & Canada: 1-800-441-4369 +31-11567-2626
1-989-832-1426 Italy: +800-783-825
Mexico: +1-800-441-4369

Latin America South Africa +800-99-5078


Argentina: +54-11-4319-0100
Brazil: +55-11-5188-9000
Colombia: +57-1-219-6000 Asia Pacific +800-7776-7776
Mexico: +52-55-5201-4700 +603-7965-5392

www.dow.com This document is intended for use within Asia Pacific, Latin America, North America

Published: 2005-11-17

© 2021 The Dow Chemical Company

Form No. 400-00089026en


Page: 4 of 4 ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Rev: 2013-01-07

You might also like