0% found this document useful (0 votes)
158 views3 pages

NOVASUN Specification Natural System

The document provides specifications for a NovaSun solar central water heater system using a natural circulation design. The system uses a closed thermal fluid circuit that circulates independently of the water storage tank to transfer heat from solar collectors without freezing or scale buildup. Key components include anodized aluminum solar collectors with selective coatings and insulation, polyurethane-foam insulated water tanks, a thermal fluid that enhances heat transfer while protecting from freezing, and electric heating elements as backup with standard 2kW power.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
158 views3 pages

NOVASUN Specification Natural System

The document provides specifications for a NovaSun solar central water heater system using a natural circulation design. The system uses a closed thermal fluid circuit that circulates independently of the water storage tank to transfer heat from solar collectors without freezing or scale buildup. Key components include anodized aluminum solar collectors with selective coatings and insulation, polyurethane-foam insulated water tanks, a thermal fluid that enhances heat transfer while protecting from freezing, and electric heating elements as backup with standard 2kW power.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

SOLAR CENTRAL WATER HEATER SPECIFICATION

FOR NATURAL SYTEM

The advance technology’s NOVASUN SOLAR water heaters use a closed circuit of natural circulation. The special
thermal fluid, used in the closed circuit, enhances the performance of the heater protects it from the freeze and
prevents the slats scale deposition inside the tubes of the collector. The closed circuit (jacket) where the thermal
fluid is circulating, is independent and does not communicate with the water storage tank. (See page 6 of
Technical Manual).

 For a better choice of the appliance, the local climate conditions must be taken into a serious
consideration, as well as your need for hot water.
 The energy saving that you will have with the NOVASUN solar water heater depends on the use of hot
water, the use of the electric resistance and the local weather condition. Under favorable weather
conditions, the energy saving may reach up to 100%. On sunny days, the power of solar radiation is
greater between 10:30am to15:30pm. For this reason it is better schedule your heavy consumption of
hot water (washing machine etc.) in the middle of the day.
 During days with low sunshine and low ambient temperature, we suggest you to turn on the electric
resistance, in order to have hot water all the time.

Solar Central Water Heater Natural system hall be as detailed below:


1. The capacity hot water consumption need for the building shall be calculated and approved by
consultant engineer.

2. The Solar Central Water Heater Natural system consist of;

a. NovaSun Solar Collectors

b. NovaSun Storage Tank

c. Electrical Element (2kw) with Thermostat

d. Thermal liquid

e. Accessories

Find below the specification details for each:

 NOVASUN SOLAR COLLECTORS: (See page 4 of Technical Manual)

The production process and raw materials are used to produce NOVASUN Solar Collectors,

Able to absorbed high thermal energy efficiency even during periods with insufficient radiation.

- Frame made from anodized aluminum profile


- Back side made of galvanized sheeting -0,6mm

- Back insulation: rock wool 40mm

- Side insulation: glass-wool of 20mm

- Absorber: A unique sheet of copper with selective titanium coating or with black paint/ultrasonic
welding or type “omega” (Ф).

- Absorber Tubes: copper pipe Ф 10mm & Ф 22mm (risers and headers)

- Cover : solar tempered glass

- Water-tightness: EPDM rubber/ transparent silicone.

 NOVASUN SOLAR STORAGE TANK: (See page 4 of Technical Manual)

- External casing made of anodized aluminum

- Tank’s insulation made from polyurethame foam 40-55mm

- Cylinder’s materials: galvanized sheeting 3mm

- Jacket’s material; low carbon steel 1.5mm

- Cylinder internal Protection; durosmalt 80-120 microns

- Additional protection; magnesium- rod

- Electric resistance; copper

- Thermostat; bipolar of four contacts

- Power rate; available from 0.8kw-4kw

 Thermal Liquid

The special thermal fluid, used in the closed circuit, enhances the performance of the heater protects it
from the freeze and prevents the slats scale deposition inside the tubes of the collector. The closed
circuit (jacket) where the thermal fluid is circulating, is independent and does not communicate with the
water storage tank.

 Accessories

Consist of:

1. Screw, nut or the support base


2. Brackets

3. Pipe Union, moly plugs

4. Screw-nuts, safety valves Plugs

5. Filling funnel of the thermal fluid.

Other component in NovaSun Solar System

 The standard power of the electric resistance is 2000W for 230V. Upon a special order, the electric
resistance can be offered with power from 800W to 4000W. For power of 110V, the electric resistance
is available (upon special order with power from 800W to 2000W.

All parts of NovaSun Central Water Heater System subjected to 5 years guarantee will provided by the
manufacturer.

For MINCOM TRADING LLC

Engineering Division
Tel: 04-267 7176 Fax: 04-267 7073
E-mail: [email protected]

You might also like