6SL3210 5HE11 0UF0 Datasheet en

The SINAMICS S210 is a 1 kW, 3-phase AC drive for vertical wall mounting with IP20 protection, operating on 200-480V input power and providing 0-550Hz output frequency for servo control applications. It has standard and fail-safe digital inputs, 24V electronics power supply, and push-in spring terminals for wiring connections up to 6mm2. The drive meets various industry standards including CE, cULus, RCM, KC, EAC, and UKCA and is suitable for SIL 2 safety applications.

Uploaded by

Car Mexico
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
218 views2 pages

6SL3210 5HE11 0UF0 Datasheet en

The SINAMICS S210 is a 1 kW, 3-phase AC drive for vertical wall mounting with IP20 protection, operating on 200-480V input power and providing 0-550Hz output frequency for servo control applications. It has standard and fail-safe digital inputs, 24V electronics power supply, and push-in spring terminals for wiring connections up to 6mm2. The drive meets various industry standards including CE, cULus, RCM, KC, EAC, and UKCA and is suitable for SIL 2 safety applications.

Uploaded by

Car Mexico
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Data sheet for SINAMICS S210

MLFB-Ordering data
6SL3210-5HE11-0UF0

Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Rated data Communication

Input Communication PROFINET

Number of phases 3 AC Ambient conditions


Line voltage 200 ... 480 V ±10 % Installation altitude 1000 m (3280.84 ft)

Line frequency 45 ... 66 Hz Cooling Air cooling using an integrated fan

Rated current 3.8 A


Ambient temperature during
Inrush current 4.3 A
Operation 0 ... 50 °C (32 ... 122 °F)

Output
Better than class 3K3, in acc. with EN
60721-3-3: 2002, without derating
Number of phases 3 AC

Rated power (at 400V) 1.00 kW Transport -40 ... 70 °C (-40 ... 158 °F)

Rated power (at 240V) 0.60 kW Class 2K4, in acc. with EN 60721-3-2:
1997, in transport packaging
Rated current IN 3.0 A
Storage -25 ... 55 °C (-13 ... 131 °F)
Max. output current 10.9 A
Class 1K4, in acc. with EN 60721-3-1:
1997, in product packaging
Pulse frequency 8 kHz

Output frequency for servo control 0 ... 550 Hz Relative humidity during

Max. operation 95 %
Electronics power supply
RH, condensation not permitted
Voltage 24 V -15 % ... +20 %
Transport, max. 95 %
Current demand, max. 1.0 A
at 40 °C (104 °F)

Bearing, max. 95 %

Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 1 of 2 Generated Thu Jul 28 16:43:21 CEST 2022
Data sheet for SINAMICS S210

MLFB-Ordering data
6SL3210-5HE11-0UF0

Figure similar

Inputs / outputs Connections

Standard digital inputs Line side

Number 5 Version push-in spring-type terminals

of which 2 for F-DI


Conductor cross-section 0.75 ... 6.00 mm² / 18 ... 10 AWG

Fail-safe digital inputs Motor end

Number 1 Version push-in spring-type terminals

Can only be used for STO/SS1 Conductor cross-section 0.75 ... 6.00 mm² / 18 ... 10 AWG

Mechanical data DC link (for braking resistor)

Version push-in spring-type terminals


Dimensions
Conductor cross-section 0.75 ... 6.00 mm² / 18 ... 10 AWG
Width 50.0 mm (1.97 in)

Cable length 10 m (32.81 ft)


Height without shield plate 231.0 mm (9.09 in)

PE connection
Depth 222.8 mm (8.77 in)

Version M4 screw studs


Mounting position vertical wall mounting

Max. motor cable length 1)


Degree of protection IP20 / UL open type
Shielded 50 m (164.04 ft)
Frame size FSA
Standards
Net weight 2.10 kg (4.63 lb )

Compliance with standards CE, cULus, RCM, KC, EAC, UKCA

CE marking Low-voltage directive 2006/95/EC

SIL 2 in acc. with IEC 61508 parts 1-3


(2010) and IEC 61800-5-2 (2016), PL
Verification of suitability for fail-
d in acc. with ISO 13849 part 1
safety
(2015), Category 3 in acc. with IEC
60204 (2007)

1) Cable length with possibility of connection an external filter