Course I - Furukawa Cabling System 2022 - CNI
Course I - Furukawa Cabling System 2022 - CNI
Cabling System
Course-I
FECSA
Furukawa (Thailand) Co., Ltd. SLIDE 1
JAPANESE COMPANY Core Values
China, Hongkong
● Furukawa FITEL Optical Products (Shanghai) Co., Ltd.
51 Brazil
Brazil,
Southern Cone 77
135
5 Besar
Andean Countries,
Central America 70
Caribbean
OFS Laboratories Metal Research Center (Nikko) Ecology and Energy Laboratory Yokohama R&D Laboratory
(New Jersey, USA) (Hiratsuka and Chiba) (Yokohama)
FITEL Photonics Laboratory R&D Center for Automotive Systems & Devices Furukawa Electric Institute of Technology Limited FISA Laboratories - Cabling
(Hiratsuka) (FETI) (Hungary) (Curitiba, BRASIL)
(Chiba)
Membership Certifications
►
Instalasi terjamin hingga 25 tahun
Saat menggunakan produk dan diinstal oleh installer yang telah
disertifikasi oleh Furukawa
• Fiber Cables
• Copper cables UTP (Copper Cables)
• Structured cabling
• Triple Play FTTx (Data, Voice and TV)
• Data Center
(Standard)
Topik Training
Training Course I (Sertifikasi)
Furukawa
Cabling System
(Struktur kabel pada Fiber Optic dan Kabel Tembaga)
(Good Practices)
(Standard)
Topik Training
Training Course I (Sertifikasi)
Furukawa
Cabling System
(Struktur kabel pada Fiber Optic dan Kabel Tembaga)
(Good Practices)
Patch cord
SWITCHING/HUB Patch cord
COMPUTER 1 COMPUTER 2
Patch cord
Outlet
Outlet
Patch Panel
COMPUTER1 COMPUTER2
Horizontal Cable Horizontal Cable
STRUKTU
KABEL 2 Pabrikasi kabel memiliki kerja sama atau berpartisipasi dengan
lembaga ataupun organisasi standarisasi.
Mendefinisikan berbagai aturan teknis dan kinerja sistem sebagai standar referensi dasar
STANDARDS untuk pabrikasi sesuai dengan Pasal 1.
ANSI/TIA-607-D ANSI/TIA-1005-A
(Bonding and grounding) (Industrial)
ANSI/TIA-758-B ANSI/TIA-1179-A
(Outside plant) (Healthcare)
ANSI/TIA-862-B
(Building automation systems)
FLOOR
Horizontal Cabling (HC)
DISTRIBUTOR
FD
HORIZONTAL
BACKBONE
Backbone Cabling
Equipment Room (ER)
BUILDING
DISTRIBUTOR
BD
EQUIPMENT
ROOM / DATA
CENTER
Adalah area yang memanjang dari soket kabel horizontal ke area kerja, yang dapat
1. Work Area (WA) berupa perangkat apa pun. Tidak terbatas hanya pada perangkat telepon dan
komputer
Kabel yang menghubungkan antara WA melalui Patch Cord ke outlet dan dari outlet ke
2. Horizontal Cabling (HC) ruang komunikasi atau dari ruang komunikasi ke titik distribusi. Paling umum
menggunakan kabel UTP CAT6 atau CAT6A.
3. Backbone Cabling Kabel utama yang menghubungkan antara lantai di gedung yang sama atau
dapat menghubungkan antara gedung yang satu dengan gedung yang lain.
4. Telecommunication Room and Ruangan tempat kabel eksternal masuk dan semua peralatan untuk
Enclosures (TR) penggunaan jaringan
5. Equipment Room (ER) Ruangan tempat kabel eksternal masuk dan semua peralatan untuk
penggunaan jaringan
6. Entrance Facilities Titik masuknya kabel dari ekternal gedung, seperti kabel serat optik dari
ISP
Commercial Building
Backbone Cabling
Entrance Facilities
DISTRIBUTION ROOMS
HORIZONTAL INTER CONNECT
Switch
Data Cable
UTP cabel Cat5E, Cat6
Data Cable
UTP cabel Cat5E, Cat6
MEDIA CABLE
Backbone Cabling
Horizontal Cabling
Menghubungkan HC – EO, IC - EO
Distributor A (Horizontal Cross-connect) Equipment Outlet
Installasi dari Patch panel ke Outlet equipment, seperti outlet di Meja
UTP Copper | Shielded atau No shielded | Category 5e, 6 atau 6A.
้สาย
ใช Optical
Panjang Cablingkabel
keseluruhan | Single-mode or Multimode
tidak boleh lebih dari 100 Meter
PERMANENT
CHANNEL
Tidak lebih dari 100 meter Jarak maksimal adalah Horizontal Cabling
1.Patch Cord 90 Meter
2.Patch Panel Yang termasuk hanya titi instalasi
3.Cable pemanen :
4.Keystone Jack 1.Patch Panel
5.Patch Cord 2.Cable
3.Keystone Jack
Test Test
1 2 3 4
Patch Cord 70 meters Cable 20 meters Cable
Horizontal Cabling
Horizontal Cabling
Horizontal Cabling
Horizontal
Cabling Bending radius
minimum 10x TIDAK LEBIH DARI 30
dari diameter METER
Work Area
Direkomendasikan menggunakan jenis outlet yang sama untuk setiap work area
YES
Hal yang perlu dipertimbangkan dalam Hal yang harus dihindari selama instalasi
instalasi • Dipasang di dekat titik risiko seperti
• Kualitas kabel dan pengoperasian panas, bahan kimia, bahan
Pathways berbahaya atau mudah terbakar
• Ukuran Jalur • Dipasang di kompartemen lift atau
• Radius tikungan area dengan kebisingan tinggi
• Mempertimbangkan pertumbuhan • Berjalan di rel yang tidak dapat
untuk masa depan melindungi kabel, seperti tidak ada
• Instalasi sesuai dengan standar yang tutup, rel pemasangan non-standar.
ditentukan.
NO
Furukawa (Thailand) Co., Ltd. SLIDE 36
Standar ANSI/TIA 569-E
PATHWAYS – Tray Kabel
Rumus Perhitungan PATHWAYS
50%
25%
Space
Ducts/Cable
< 60%
D = 1/2” (12.70mm) diameter 3.3 4.6 5.6 6.1 7.4 7.9 9.4 13.5 15.8 17.8
d = 7.4mm
½ 1 1 0 0 0 0 0 0 0 0
Space
> 60%
¾ 6 5 4 3 2 2 1 0 0 0
1 8 8 7 6 3 3 2 1 0 0
1¼ 16 14 12 10 6 4 3 1 1 1
D = 3/4” (19.05 mm)
d = 7.4mm
1½ 20 18 16 15 7 6 4 2 1 1
2 30 26 22 20 14 12 7 4 3 2
2½ 45 40 36 30 17 14 12 6 3 3
Cable duct/ pathways tidak
terpakai lebih dari 40 % dari 3 70 60 50 40 20 20 17 7 6 6
ukuran aktual
3½ - - - - - - 22 12 7 6
4 - - - - - - 30 14 12 7
* Menentukan jarak antara kabel data dan kabel listrik tergantung pada ukuran arus listrik
/ Electrical current (A);
Furukawa (Thailand) Co., Ltd. SLIDE 40
Standar ANSI/TIA 569-E
Persyaratan Umum
(FIRESTOP)
Digunakan untuk mencegah api, asap, atau air
melewati penghalang ke dalam ruangan.
Example of firestop
Orange
Terminals of Network
Auxiliary Circuits connections
Green
IC Backbone
White
Second level
Persyaratan Umum
Terminations IC-TC
Backbone
Grey
Standar ANSI/TIA 606-C
Horizontal Cabling
Stations
Terminations
Blue
SLIDE 42
Standar ANSI/TIA 607-D
Persyaratan Umum
Sistem Grounding
dipasang sesuai
Mencegah Kebocran
dengan standar
Listrik
keselamatan
TMGB
• Telecommunications
main grounding busbar
Electrical service entrance
Vertical Union
TGB
for Telecom
• Telecommunications
grounding busbar
Services Entrance GE
Equipment Room
Union conductor for Telecommunications
• Grounding Equalizer
(Standard)
Topik Training
Training Course I (Sertifikasi)
Furukawa
Cabling System
(Struktur kabel pada fiber optic dan kabel tembaga)
(Good Practices)
VERIFIED LISTED
Cables measured in
Alien Crosstalk
(Standards)
Topik Training
(Good Practices)
TWISTED-PAIR CABLES
Standar ANSI/TIA-568.2-D
ISO/IEC 11801
XX / XTP
Global Shielding Pair Shielding Twisted Pair
U F S
Unshielded Foiled Braid Screened S/FTP SF/UTP
TYPES OF SHIELDINGS
Low Attenuation
Primary coating
Cladding
core
core
Primary coating
Cladding
HTTP://WWW.OFSOPTICS.COM
core
Primary coating
Cladding
Contoh perangkat yang mengubah
sinyal listrik menjadi sinyal optik
Analogical electrical signal Sektor Pemancar Sektor Penerima
Wavelength (nm)
Mediu
Interconnect AKA Defined Connector[13] Media type Wavelength Max range Notes
m
vendor-specific, identical
Appeared to 10GBASE-SR except for
10GBASE-USR Ultra short reach X2, SFP+ Fiber Serial multi-mode 850 nm 100 or 150 m
in 2011 lower
performance/reach[14]
Short wavelength, XENPAK, X2, OM3: 300 m
10GBASE-SR 2002 Fiber Serial multi-mode 850 nm
short reach XFP, SFP+ OM4: 400 m
Long wavelength, XENPAK, X2,
10GBASE-LR 2002 Fiber Serial single-mode 1310 nm 10 km
long reach XFP, SFP+
Extra long
XENPAK, X2,
10GBASE-ER wavelength, 2002 Fiber Serial single-mode 1550 nm 40 km
XFP, SFP+
extended reach
Not covered by IEEE
XENPAK, X2, 802.3ae, identical to -ER
10GBASE-ZR - Fiber Serial single-mode 1550 nm 80 km
XFP, SFP+ with higher performance
optics
Four-lane WDM on a
300 m (multi-
single fiber pair, costly
XENPAK, X2, CWDM multi-mode 1275, 1300, 1325, mode)
10GBASE-LX4 2002 Fiber and complex, mostly
SFP+ or single-mode 1350 nm 10 km (single-
replaced by 10GBASE-
mode)
LRM
Primary coating
Cladding
core
core
Primary coating
Cladding
HTTP://WWW.OFSOPTICS.COM
core
Primary coating
Cladding
Contoh perangkat yang mengubah
sinyal listrik menjadi sinyal optik
Analogical electrical signal Sektor Pemancar Sektor Penerima
Wavelength (nm)
Mediu
Interconnect AKA Defined Connector[13] Media type Wavelength Max range Notes
m
vendor-specific, identical
Appeared to 10GBASE-SR except for
10GBASE-USR Ultra short reach X2, SFP+ Fiber Serial multi-mode 850 nm 100 or 150 m
in 2011 lower
performance/reach[14]
Short wavelength, XENPAK, X2, OM3: 300 m
10GBASE-SR 2002 Fiber Serial multi-mode 850 nm
short reach XFP, SFP+ OM4: 400 m
Long wavelength, XENPAK, X2,
10GBASE-LR 2002 Fiber Serial single-mode 1310 nm 10 km
long reach XFP, SFP+
Extra long
XENPAK, X2,
10GBASE-ER wavelength, 2002 Fiber Serial single-mode 1550 nm 40 km
XFP, SFP+
extended reach
Not covered by IEEE
XENPAK, X2, 802.3ae, identical to -ER
10GBASE-ZR - Fiber Serial single-mode 1550 nm 80 km
XFP, SFP+ with higher performance
optics
Four-lane WDM on a
300 m (multi-
single fiber pair, costly
XENPAK, X2, CWDM multi-mode 1275, 1300, 1325, mode)
10GBASE-LX4 2002 Fiber and complex, mostly
SFP+ or single-mode 1350 nm 10 km (single-
replaced by 10GBASE-
mode)
LRM
MM SM Cladding = 125m
Core = 9m
Multimode Single-Mode
Multimode Multimode Multimode Single-mode
OM 1 OS 1
100/140 m 62.5/125 m 50/125 m 9/125 m
OM 2 OS 2 OM2 OS2
OM1
OM 3 *MASIH DIGUNAKAN OM3
OM 4 OM4
OM 5 *SUDAH JARANG DIGUNAKAN OM5
SINGLE-MODE (SM)
Cladding
Core
100 Gb/s
40 Gb/s LaserWave Fiber Multimode
10 Gb/s •(850 nm CWDM)) 10 Gb/s Bit Period 10 Gb/s Bit Period
1 Gb/s
100
Mb/s Fiber
10
Mb/s
Core
Center
Fibers MM Fibers SM
Standard ($$) Standard ($$$)
Multimode
Fiber
Singlemode
Fiber
10GBase-SR 850 nm
(10 Gb/s) Serial VCSEL
33 82 300 550 NA
10GBase-LX4 1300 nm 1 1
300 300 300 300 10,000
(10 Gb/s) CWDM Laser
850 nm
40GBase-SR4 2
(40 Gb/s)
Parallel VCSEL NA NA 100 150 NA
Array
850 nm
100GBase-SR10 2
(100Gb/s)
Parallel VCSEL NA NA 100 150 NA
Array
1Mode Conditioning Patch-cords required
2With 1.0dB connector loss
LOOSE TUBE
Optical Fiber
FIBERS
Thixotropic gel
(hydrophobia compound)
Tube 1 • Blue
2 • Orange
3 • Green
4 • Brown
5 • Grey / Slate
6 • White
7 • Red
8 • Black
9 • Yellow
10 • Purple / Violet
11 • Pink / Rose
12 • Aqua
TIGHT BUFFER
Core
Primary coating
Secondary coating
“Vain” Jacket
1. Attenuation atau Loss yang terjadi karena perjalanan cahaya melalui brbagai media kaca,
Insertion loss udara atau sambungan optik
Loss yang terjadi karena refleksi cahaya, Loss ini hanya terjadi pada
2. Return loss konektor
Fusion Splicer
Insertion loss
Return loss Insertion loss - IL (dB)
(Type) (Standard) (Typical)
(Standard) (Typical)
(Type)
SM - >40 Fusion 0.02
SPC > 20
MM - >30 0.3
Field connector 0.15
SM - >50
UPC > 26
MM - >30
SPC
SPC dan UPC compatible satu
APC > 55 >60 UPC sama lain
Patch cord optic duplex Furukawa dengan Polaritas A-B, Standar TIA 568.3-D
FIBER-LAN INDOOR
Specification Telcordia GR-409
Backing
Elements
Tight Buffer construction
FIBER-LAN INDOOR/OUTDOOR
Specification GR-409
2 up to 12 fibers BLI
Totally dielectric
Anti-flame jacket / UV
Isolated Fibers
Tight Buffer construction
Backing
Elements Possible direct connectorization
DIELECTRIC (CFOA-DD)
Recommendation Telcordia GR-20
2 up to 288 fibers
Totally dielectric
External Jacket
Construction in simple cover
Traction Element
Protection Tube Core filled with gel (DD-G) or inflatable
Optical Fibers yarns (DD-S)
Central Dielectric Element
ARMORED
Dielectric Armored or not
- Corrugated Steel, PFV
External Environments
Flammability Ratings adalah definisi dan klasifikasi perilaku api untuk kabel dalam ruangan. Ini membuat produsen kabel, pemasang, dan pengguna
menjadi sama. Meningkatnya kesadaran akan keamanan produk akibat kebakaran.
Secara umum, kabel dalam ruangan diklasifikasikan menjadi 4 jenis menurut sifat mudah terbakarnya sebagai berikut:
UL 1666 UL 1666
CMX LSZH-1
IEC60332-1 UL 1581 CMX + IEC 61034-1 / 61034-2
Kita dapat membedakan jenis kabel menurut tahanan isolasi (Jaket) sebagai berikut
Tinggi
Communication
CMP Metallic
Plenum
• Standar
• NFPA 262
• Tidak mudah terbakar dan apabila terbekar tidak
menghasilkan asap yang berbahaya
• Aplikasi
• Jalur kabel dengan sirkulasi udara.
• Tempat dengan banyak kabel, dilengkapi dengan
AC
Plenum adalah jalur kabel dimana dijalur tersebut dipakai sebagai saluran udara juga.
Furukawa (Thailand) Co., Ltd. SLIDE 104
Flammability Classes
Communication
CMR Metallic
Riser
• Standar
• UL1666
• Apabila terbakar api tidak akan menyebar ke
antara lantai.
• Aplikasi
• Jaringan kabel antar lantai / jaringan vertikal
(sebagai backbone).
• Biasanya jalur kabel berada di shaft room yang
tidak menyatu dengan saluran udara.
Communication
CM Metallic
• Standar
• IEC60332-3
• UL1685
• Aplikasi
• Jaringan kabel di lantai yang sama atau antar
kamar dengan proteksi tambahan.
• Dan di area tersebut, tidak digunakan ventilasi
udara
Communication
CMX Metallic
Limited Use
• Standar
• IEC 60332-1
• UL2556
• Kabel jenis ini hanya bertahan selama 60 detik
apabila terbakar.
• Aplikasi
• Jaringan dirumah atau small office
• Jaringan kabel tidak terlalu padat.
LSZH
IEC 60332-3 + IEC 61034-2 +
Low Smoke IEC 60754-2
• Standar
• IEC 60332-1 or 3 – Flammability
• IEC 61034-1 or 2 – Low generation of smoke
• IEC 60754-1 or 2 – Acid Gas Content
• Aplikasi
• Tempat yang banyak digunakan oleh banyak
orang.
• Pusat pembelanjaan ataupun rumah sakit. Non LSZH LSZH
• Call center, Data centers
• Sebagai alternatif jenis Plenum
• Memenuhi sertifikasi LEED LEED (Leadership in Energy and Environmental Design)
Attribute LSZH
LSZH-1 CMP/OFNP CMR/OFNR CM/OFN CMX
(LSZH-3)
Fire Resistance Baik Cukup Sangan Baik Sangan Baik Baik Cukup
Smoke Generation Sangan Baik Sangan Baik Baik Kurang Kurang Kurang
Toxicity Sangan Baik Sangan Baik Kurang Kurang Kurang Kurang
Gas Corrotion Sangan Baik Sangan Baik Sangan Baik Kurang Kurang Kurang
(Standards)
Topik Training
Training Course I (Certifications)
Furukawa
Cabling System
(Structured Cabling in Copper and Optical)
(Best Practices)
Chemistry Risk
Cable LAN TPU PVC 105º PVC
Acid / Strong base n n n
Industrial Oils n r r
Organics Solvents n n r
TPU adalah Termoplastik Poliuretan yang merupakan bahan dengan fleksibilitas tinggi. Tahan terhadap benturan
secara efektif, tahan terhadap asam, alkali, tahan api sangat tinggi, tahan terhadap sinar UV.
PVC adalah Polyvinyl Chloride. Ketahanan terhadap api yang baik. PVC akan padam
sendiri ketika dinyalakan. Tahan panas, asam, alkali, dan bahan kimia cukup baik.
CAT.6A
CAT.6
dalam 100 meter Mbps dalam 100 yang mampu
meter mentransmisikan
Tidak support untuk
teknologi baru Mendukung sistem 10Gbps hingga 100
seperti sistem 10Gbps (dengan meter.
10Gbps. beberapa batasan)
Durasi
Periode penggunaan Durasi penggunaan penggunaan
CAT5E adalah sekitar CAT6 adalah sekitar
5 tahun. 10 tahun. CAT6A adalah
sekitar 18 tahun.
CAT.5e CAT.6A
CAT.6 “ Alien Crosstalk ”
( NEXT / FEXT)
F/UTP
U/UTP
Better Margin
Cat 6A
F/UTP
CHANNEL CERTIFICATION
Rekomendasi instalasi
Rekomendasi instalasi
Rekomendasi instalasi
PATCH PANEL – CABLE GUIDE “Tampak Belakang”
Rekomendasi instalasi
13mm
Peringatan:
Hindari membuka kabel lebih dari 13 mm.
Pasang tutup dan kunci dengan kabel ties.
100 Singlemode
Velocidad (Gb)
40
Multimode (SM)
10
1 (MM)
100 200 300 400 500 600 700 800 900 1000 1100 >1200
Longitud (m)
Panjang (Meter)
• Penggunaan (Internal)
• Berapa tingkat api jika terjadi kebakaran tertentu?
Implementasi 1 • Penggunaan (Internal/External)
• Haruskah itu menjadi isolator tahan api?
• Penggunaan (External)