0% found this document useful (0 votes)
156 views5 pages

Analog Input Module: SCM20X

The document describes an SCM20X analog input module with the following key details: 1. It has 8 universal analog input channels that can accept thermocouples, RTDs, mV, and 4-20mA signals. 2. It has communication ports for RS485 or Ethernet, and supports MODBUS RTU and TCP protocols for connecting to PLCs and SCADA systems. 3. It provides accurate analog measurements, with 16-bit ADC resolution and temperature compensation for thermocouple and RTD inputs.

Uploaded by

Chethan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
156 views5 pages

Analog Input Module: SCM20X

The document describes an SCM20X analog input module with the following key details: 1. It has 8 universal analog input channels that can accept thermocouples, RTDs, mV, and 4-20mA signals. 2. It has communication ports for RS485 or Ethernet, and supports MODBUS RTU and TCP protocols for connecting to PLCs and SCADA systems. 3. It provides accurate analog measurements, with 16-bit ADC resolution and temperature compensation for thermocouple and RTD inputs.

Uploaded by

Chethan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

SCM20X

ANALOG INPUT MODULE


RS485, ETHERNET, TMAX

8 CHANNELS, COMMUNICATION PORT:


EACH WITH UNIVERSAL INPUT RS485 OR ETHERNET

COST-EFFECTIVE
SIZE : 75 x 100 x 110
REMOTE I/O FOR PLCS

POWERFUL, FLEXIBLE
Tmax VERSION WITH 4~20 mA
SCADA SOFTWARE

WITH TMAX WITH ETHERNET

› 8 universal analog inputs


› 8 thermocouples, Pt100, 0~50 mV, 0/4~20 mA, digital input
› Isolated RS485/MODBUS RTU, Upto 19200 Baud rate
› MODBUS / TCP & Telnet multidrop communication for PLC, SCADA, etc.
› 85~265 VAC or 15~60 V DC supply
› 3 key, 3 level programming
› Powerful, flexible SCADA software available
› 4~20 mA output option
› Standard & High Performance Version

SCM20X
www.radix.co.in
SCM20X
ANALOG INPUT MODULE
RS485, ETHERNET, TMAX

SPECIFICATIONS All specifications at ambient of 25 °C, unless specified otherwise

INPUTS COMMUNICATION
Maximum no. of channels 8 SCM201
Input types Port RS485, isolated
Thermocouple B, E, J, K, N, R, S, T Protocol MODBUS RTU
RTD Pt100, 3-wire Baud rate 4800/9600/19200 bps
Linear input 0~50 mV, 0~20 mA, 4~20 mA Slave ID User programmable, 1~247
(each input independently scaleable Minimum polling interval 250 milliseconds
and without any DIP reconfiguration) Data types Float, swapped float, integer,
Digital input Potential free integer x10
Channel scan rate < 0.8 seconds for 8 channels SCM203
Channel-to-channel isolation Suitable for low (leakage) voltages less System
than 3V AC CPU 32 bit MCU
Input protection Communication interface
Thermocouple, mV, RTD inputs ± 10 V DC max Ethernet 10/100 base TX , RJ-45
Current inputs Current limit < 30 mA, 28 V DC max Protocol Modbus/TCP & Telnet
Range limits See Table 1 Com port format
Accuracy See Table 1 Data bit 8
ADC resolution 16 bit Parity None
Cold junction compensation Automatic Stop bit 1
Sensor break protection User programmable Baud rate 9600 bps
Slave ID User programmable, 1~247
ANALOG OUTPUT Minimum polling interval 250 milliseconds
Current 0~20 mA, 4~20 mA, 20~0 mA, 20~4 mA Data types Float, swapped float, integer,
Load for current output 0~500W integer x10
Voltage 0~2 VDC, 0~5 VDC, 0~10 VDC /
user specified INDICATION
Load for voltage output > 10 kohms Display type 2x16 character LCD display

ADJUSTMENTS OTHER
Unit User selectable Keypad Tactile, 3 keys
Resolution User selectable Memory for programmed Non-volatile, indefinite duration
0.0001,0.001,0.01, 0.1or 1 for parameters
linear input, 0.1 or 1 for temperature Supply voltage a) 85~265 V AC, 50/60 hz
b) 15~60 V DC
OTHER MA JOR PARAMETERS Power consumption 3 watts
Password
Level lock TEMPERATURE, HUMIDITY
Display scan rate 1~99 seconds/channel Ambient, storage -22~+85°C
SKIP channel Enable/disable Ambient, operation 0~50°C
Input bias -99.9 ~ 99.9 Relative humidity 0~95%
Power ON output 0.0 ~ 99.9 sec
activation delay ENCLOSURE
Material ABS plastic
CALIBRATION Dimensions (in mm) 100(W) x 75(H) x 110(D)
Zero & span Through front panel keys & display Protection IP20
User calibration Sensor span and sensor zero Mounting Snap on for 35mm DIN rail to
CJC calibration Room temperature DIN 46277

TABLE 1
RANGE LIMITS RANGE IN WHICH
SENSOR / INPUT TYPICAL ACCURACY WORST CASE
(°C / EU) ACCURACY IS SPECIFIED
AT 30 °C ACCURACY
LOW SCALE HIGH SCALE LOW SCALE HIGH SCALE (°C / EU) (°C / EU)

Pt - 6% Rh / Pt - 30% RH (B) 400 1820 400 1820 ±3 ±5

Chromel / Constantan (E) -200 1000 0 1000 ±1 ±3

Iron / Constantan (J) -210 760 0 760 ±1 ±3

Chromel / Alumel (K) -200 1372 -50 1200 ±1 ±3

Nicrosil / Nisil (N) -200 1300 -50 1200 ±1 ±3

Pt / Pt - 13% Rh (R) 0 1760 0 1760 ±2 ±5

Pt / Pt - 10% Rh (S) 0 1760 0 1760 ±2 ±5

Copper / Constantan (T) -200 400 -200 400 ±1 ±3


Pt100, 3-wire -200 850 -200 850 ± 0.5 ± 2.0

Linear (0~50 mV, 0~20 mA, 4~20 mA) -19999 19999 -19999 19999 ± 5 EU ± 20 EU

SCM20X
www.radix.co.in
SCM20X
ANALOG INPUT MODULE
RS485, ETHERNET, TMAX

APPLICATION

Thermocouple

Flow Totaliser
FLOTO

RH+T Transmitter
SC805

Pressure
Transmitter
SC504

Isolated Transmitter
SC601

SCM201/SCM203 0~10 V DC
3-Port Isolator
SCC401
Temperature
Transmitter
TX1HM

RTD

TYPICAL CONFIGURATION

SCM203-01 SCM203-02 SCM203-23


24 Port
Ethernet switch

LAN
192.168.1.1 192.168.1.2 192.168.1.23
8 Port
Ethernet switch
SCM203-24 SCM203-25 SCM203-46

LAN
192.168.1.24 192.168.1.25 192.168.1.46

Server with 21 CFR SCM203-47 SCM203-48 SCM203-69


SCADA Systems

LAN
192.168.1.47 192.168.1.48 192.168.1.69

SCM20X
www.radix.co.in
SCM20X
ANALOG INPUT MODULE
RS485, ETHERNET, TMAX

CURRENT OUTPUT MODES


There are 3 current output modes :

Mode No. Mode Name Current output 1

1 T max T max
2 TA T of assigned channel A

Mode 1 : T Max
Current output (I) corresponds to highest temperature (Tmax) from all channels.

Mode 2 : TA
I corresponds to temperature (T) of any assigned channel A.

SCADA SCREENS

SCM203

SCM203

SCM20X
www.radix.co.in
SCM20X
ANALOG INPUT MODULE
RS485, ETHERNET, TMAX

ORDERING INFORMATION

Model : SCM201

Standard Options
SCM201, standard version, will be supplied with the
following specifications :

No. of channels 8
Output RS485/MODBUS RTU

Example 2310 01 2310 01


Product code 2310
Supply voltage 01 85~265 VAC
02 15~60 VDC

Model : SCM201 Tmax

Standard Options Non-standard Options


SCM201, standard version, will be supplied with the The following ordering options are available on request.
following specifications : Minimum order quantity and/or minimum order value may apply.

Input type Universal Option Details


Output 4~20 mA for Tmax
1. Analog output 0~10 V DC
Supply 85~265 V AC

Example 2432 01 01 2432 01 01


Product code 2432
No. of channels 01 4
02 8
Supply voltage 01 85~265 VAC
02 15~60 VDC

Model : SCM203
Standard Options Non-standard Options
SCM203, standard version, will be supplied with the The following ordering options are available on request.
following specifications : Minimum order quantity and/or minimum order value may apply.

No. of channels 8 Option Details


Output ETHERNET MODBUS TCP 1. No. of channels 4
All channels with a
Example 2548 01 2548 01 2. Specify input type
given input type
Product code 2548
Supply voltage 01 85~265 VAC
02 15~60 VDC

CAT#672R0/A

ENQUIRIES
RADIX ELECTROSYSTEMS PVT LTD
Instruments: [email protected] B-14, 2nd Floor, Ghanshyam Indl Estate
Sensors: [email protected]
Veera Desai Road, Andheri (West)
Gauges: [email protected]
Mumbai - 400 053, India
Automation: [email protected]
Level: [email protected] + 91 22 42537707 l [email protected]
www.radix.co.in