VLC-1600-E

The Alerton® VisualLogic® VLC-1600-E is a versatile, BACnet-


compliant, fully programmable input monitoring device. It is ideally
suited for applications with high input density, where it can augment the
input capabilities of other controllers. As a native BACnet controller, it
integrates seamlessly with your BACnet system, communicating at up to
115 Kbps on a BACnet MS/TP LAN.
The VLC-1600-E is a cost-effective choice when extensive monitoring
of process variables is required for fault detection & diagnostics, as well
as for cloud-based analytics.
The VLC-1600-E supports the Alerton Microtouch™, as well as the
BACtalk® Microset, Microset II, and Microset 4 intelligent wall sensors,
which offer convenient data display, setpoint adjustment, and technician
access to equipment setup parameters.
All VLC-1600-E control logic is programmed using Alerton's easy-to-
learn graphical programming language, VisualLogic™. Programming
and setup data are stored in non-volatile flash memory, ensuring stable
and reliable operation.
High-resolution 16-bit universal inputs are auto-selectable for
thermistor, dry contact, pulse, 0-5 V, 0-10 V, or 4-20 mA. The
VISUALLOGIC UNITARY FIELD ®
VLC-1600-E has no control outputs.
CONTROLLER
FEATURES AND HIGHLIGHTS
• Fully BACnet-compliant on MS/TP LAN at up to 115.2 Kbps.
• Programmable control logic can be field-modified.
• Downloadable operating code to allow for future software
improvements.
• 32-bit processor architecture with all program data backed up in
nonvolatile flash memory.
• High-speed processing of DDC program, with an internal logical
loop time of 100 msec.
• Backwards compatible with older VLC-1600 and VLC-1600C3
models.

APPLICATIONS
Recommended for applications with high input density, where it can
cost effectively augment the input capabilities of other controllers and
allow for system troubleshooting.

VLC-1600-E

UI HBO GBO RO AO AF F
UNIVERSAL HOT SWITCHED TRIAC GROUND SWITCHED
INPUTS BINARY OUTPUTS BINARY OUTPUTS RELAY OUTPUT ANALOG OUTPUTS AIR-FLOW SENSOR FILTER

16 0 0 0 0 - -
© 2019 Honeywell International Inc. All Rights Reserved. LTDATA-VLC-1600-E 1219 1
VLC-1600-E

TECHNICAL DATA ORDERING INFORMATION


POWER – 24 VAC @ 50-60 Hz. 5 VA minimum (maximum 26 VA ITEM NUMBER
with loads). Half-wave rectified. VLC-1600-E ALERTON VISUALLOGIC CONTROLLER BACNET
INPUTS – 16-bit universal inputs accept 3k (Ibex) or 10k thermistor
(type II), dry contact, 0-20 mA, 0-10 V, 0-5V, or dry-contact pulse. CERTIFICATION AND CONFORMANCE
External 250-ohm resistor required for 0-20 mA inputs. Pulse input BACNET CONFORMANCE – An application specific controller (ASC)
maximum frequency of 100 Hz. Pulse input minimum duty cycle 5mS level device; tested and approved by BTL. See Protocol Implementation
ON / 5mS OFF (pulse input not supported on IN-0). Conformance Statement (PICS).
POWER OUTPUT FOR EXTERNAL SENSORS – 20 VDC UL – Listed Underwriters Laboratory for Open Energy Management
±10% @ 100 mA maximum Equipment (PAZX) under the UL Standard for Safety 916; listing includes
MICROSET – Supports BACtalk® Microset, Microset II, or Microset both U.S. and Canadian certification.
4 on input 0 (IN-0). EMC – EMC Directive 89/336/EEC (European CE Mark).
INPUT/OUTPUT TERMINATIONS – Removable header-type FCC – This device complies with part 15 of the FCC Rules. Operation
screw terminals accept 14-24 AWG wire. is subject to the following two conditions: (1) This device may not cause
MAX DIMENSIONS – 4.9" (125mm) H x 5" (127mm) W x harmful interference, and (2) this device must accept any interference
1.4" (36mm) D received, including interference that may cause undesired operation.

MOUNTING – Screw mounting


ENVIRONMENTAL – 0 to 158°F (-17 to 70°C) / 5 to 95%RH,
non-condensing
COMMUNICATIONS – EIA-485 (RS-485) over twisted shielded-
pair (TSP); auto-baud switching (9.6kbps, 19.2kbps, 38.4kbps,
76.8kbps, or 115.2kbps); communication status LED.
PROTOCOLS – BACnet MS/TP (master)
PROGRAMMING – Supports Alerton’s BD4 DDC file format using
Alerton’s VisualLogic® toolset.
MICROPROCESSOR – 32-bit ARM Cortex-M4F, 80 MHz
MEMORY – 512 MB non-volatile flash.
SECURITY – Integrated secure boot prevents loading of
tampered firmware.

16201 25th Avenue W., Lynnwood, WA 98087


Telephone: (425) 921-4900 / Fax: (425) 921-4872
alerton.com / [email protected]