100% found this document useful (1 vote)
206 views

Power Factor Correction Conversion Chart

The document provides a conversion chart for determining the necessary capacitor kilovars to improve power factor based on the original power factor and desired power factor. It includes a table with kilowatt multipliers for various original and desired power factor combinations.

Uploaded by

John Bundang
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
206 views

Power Factor Correction Conversion Chart

The document provides a conversion chart for determining the necessary capacitor kilovars to improve power factor based on the original power factor and desired power factor. It includes a table with kilowatt multipliers for various original and desired power factor combinations.

Uploaded by

John Bundang
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

6/8/22, 11:43 AM Power Factor Correction Conversion Chart

(903) 984-3061 | 2800 Hwy. 135 North, Kilgore, TX 75662

Steelman Industries (https://www.steelman.com) (/request-

(https://www.capacitorconverters.com/)

POWER FACTOR CORRECTION


CONVERSION CHART
<< Index (/power-factor-correction-capacitors/kvar-application-guide/) |  < Page 3
(/power-factor-correction-capacitors/kvar-application-guide/suggested-capacitor-
ratings) | Page 5 > (/power-factor-correction-capacitors/kvar-application-
guide/motor-and-distribution-panel-installation)

TABLE 3
KW Multipliers for Determining Capacitor Kilovars

 
 

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 1/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

Origi Desired Power Factor


nal

Pow
er
0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.91
Fact
or

0.51 .962 .989 1.01 1.04 1.06 1.09 1.12 1.14 1.17 1.20 1.23
5 1 7 4 0 7 5 3 1

0.52 .919 .945 .971 .997 1.02 1.05 1.07 1.10 1.13 1.15 1.18
3 0 6 3 1 9 7

0.53 .876 .902 .928 .954 .980 1.00 1.03 1.06 1.08 1.11 1.14
7 3 0 8 6 4

0.54 .835 .861 .887 .913 .939 .966 .992 1.01 1.04 1.07 1.10
9 7 5 3

0.55 .795 .821 .847 .873 .899 .926 .952 .979 1.00 1.03 1.06
7 5 3

0.56 .756 .782 .808 .834 .860 .887 .913 .940 .968 .996 1.02
4

0.57 .718 .744 .770 .796 .822 .849 .875 .902 .930 .958 .986

0.58 .681 .707 .733 .759 .785 .812 .838 .865 .893 .921 .949

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 2/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

Origi Desired Power Factor


nal

Pow
er
0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.91
Fact
or

0.59 .645 .671 .697 .723 .749 .776 .802 .829 .857 .885 .913

0.60 .609 .635 .661 .687 .713 .740 .766 .793 .821 .849 .877

0.61 .575 .601 .627 .653 .679 .706 .732 .759 .787 .815 .843

0.62 .542 .568 .594 .620 .646 .673 .699 .726 .754 .782 .810

0.63 .509 .535 .561 .587 .613 .640 .666 .693 .721 .749 .777

0.64 .474 .503 .529 .555 .581 .608 .634 .661 .689 .717 .745

0.65 .445 .471 .497 .523 .549 .576 .602 .629 .657 .685 .713

0.66 .414 .440 .466 .492 .518 .545 .571 .598 .626 .654 .682

0.67 .384 .410 .436 .462 .488 .515 .541 .568 .596 .624 .652

0.67 .354 .380 .406 .432 .458 .485 .511 .538 .566 .594 .622

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 3/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

Origi Desired Power Factor


nal

Pow
er
0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.91
Fact
or

0.69 .325 .351 .377 .403 .429 .456 .482 .509 .537 .565 .593

0.70 .296 .322 .348 .374 .400 .427 .453 .480 .508 .536 .564

0.71 .268 .294 .320 .346 .372 .399 .425 .452 .480 .508 .536

0.72 .240 .266 .292 .318 .344 .371 .397 .424 .452 .480 .508

0.73 .212 .238 .264 .290 .316 .343 .369 .396 .424 .452 .480

0.74 .185 .211 .237 .263 .289 .316 .342 .369 .397 .425 .453

0.75 .158 .184 .210 .236 .262 .289 .315 .342 .370 .398 .426

0.76 .131 .157 .183 .209 .235 .262 .288 .315 .343 .371 .399

0.77 .105 .131 .157 .183 .209 .236 .262 .289 .317 .345 .373

0.78 .078 .104 .130 .156 .182 .209 .235 .262 .290 .318 .346

0.79 .052 .078 .104 .130 .156 .183 .209 .236 .264 .292 .320

0.80 .026 .052 .078 .104 .130 .157 .183 .210 .238 .266 .294

0.81 .000 .026 .052 .078 .104 .131 .158 .184 .212 .240 .268

0.82   .000 .026 .052 .078 .105 .131 .158 .186 .214 .242

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 4/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

Origi Desired Power Factor


nal

Pow
er
0.81 0.82 0.83 0.84 0.85 0.86 0.87 0.88 0.89 0.90 0.91
Fact
or

0.83     .000 .026 .052 .079 .105 .132 .160 .188 .216

0.84       .000 .026 .053 .079 .106 .134 .162 .190

0.85         .000 .027 .053 .080 .108 .136 .164

0.86           .000 .026 .053 .081 .109 .137

0.87             .000 .027 .055 .083 .111

0.88               .000 .028 .056 .084

0.89                 .000 .028 .056

0.90                   .000 .028

0.91                     .000

0.92                      

0.93                      

0.94                      

0.95                      

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 5/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

Example: Total KW-input of load from wattmeter reading 100 KW at a power factor
of 65%. The capacitive KVAR necessary to raise the power factor to 95% is found
by multiplying the 100 KW by the factor found in the table (.840). Then 100 KW x
0.840 = 84 KVAR. Use 85 KVAR

<< Index (/power-factor-correction-capacitors/kvar-application-guide/) |  < Page 3


(/power-factor-correction-capacitors/kvar-application-guide/suggested-capacitor-
ratings) | Page 5 > (/power-factor-correction-capacitors/kvar-application-
guide/motor-and-distribution-panel-installation)

How Can We Help?


Let us know how we can help find the right equipment for
your application.

Contact Us (/contact/)

Power Factor Rotary Converters Static Converters View Our Partner


Site

2800 (https://www.capaci (https://www.capaci (https://www.capaci STEELMAN


Hwy. torconverters.com/p torconverters.com/ro torconverters.com/st INDUSTRIES

135 ower-factor- tary-converters/) atic-converters/) For Industrial Ovens


North
correction- 230V Rotary 230V Static
capacitors/) Converters Converters
(https://www.capacit (https://www.capacit

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 6/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

Kilgore Automatic / Switched orconverters.com/proorconverters.com/pro Industrial


, TX Capacitors duct-category/rotary- duct-category/static- Process
75662 (https://www.capacit phase-converter- phase- Ovens

Phone orconverters.com/prosystems/230v-rotary- converters/230v- Burn-Off

: 903- duct-category/power- converters/) static-converters/) Ovens

984- factor-correction- 460V Rotary 460V Static


capacitors/automatic Converters Converters
3061
L
(tel:903 -switched- (https://www.capacit (https://www.capacit
e
-984- capacitors/) orconverters.com/proorconverters.com/pro
a
3061)
Fixed Capacitors duct-category/rotary- duct-category/static- r
Fax: (https://www.capacit phase-converter- phase- n
903- orconverters.com/prosystems/460v-rotary- converters/460v- M
984- duct-category/power- converters/) static-converters/) o
factor-correction- Rotary Advantage Static Installation r
1384
e
capacitors/fixed- (https://www.capacit Manual
(
capacitors/) orconverters.com/rot (https://www.capacit
h
KVAR Application ary-converters/rotary- orconverters.com/sta t
Guide advantage/) tic- t
(https://www.capacit Rotary Sizing converters/installatio p
orconverters.com/po (https://www.capacit n-manual/) s
wer-factor-correction- orconverters.com/rot :
Product Support /
capacitors/kvar- ary-converters/rotary-
(https://www.capaci /
application-guide/) sizing/)
torconverters.com/re w
Harmonics Rotary Applications
sources/) w
(https://www.capacit (https://www.capacit w
orconverters.com/po orconverters.com/rot
Contact Us .
wer-factor-correction- ary-converters/rotary-
(https://www.capaci
s
capacitors/system- phase-converters- t
torconverters.com/c e
harmonic- applications/)
ontact/) e
guidelines/)
l
m
https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 7/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

P
VAR Managers Installation Manual a
a (https://www.capacit (https://www.capacit n
y orconverters.com/po orconverters.com/rot .
N c
o wer-factor-correction- ary-
w capacitors/var- converters/installing-
o
(h m
tt manager- the-has-rotary/)
)
p advantages/)
s:
/ FAQ
/ (https://www.capacit
w
w orconverters.com/po
w wer-factor-correction-
.c
a capacitors/power-
p factor-faq/)
a
ci
to
rc
o
n
v
er
te
rs
.c
o
m
/
p
a
y-
n
o
w
/)

© 2022 Capacitor Converters

Digital Marketing by Visual App


(htt // i l )

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 8/9
6/8/22, 11:43 AM Power Factor Correction Conversion Chart

(http://www.visualapp.com)

https://www.capacitorconverters.com/power-factor-correction-capacitors/kvar-application-guide/power-factor-conversion-chart/ 9/9

You might also like