Instructions: Concerned Components
Instructions: Concerned Components
Solution
To ensure correct handling of the WECS-
9520 software update procedure by the
ship’s engineers, this Bulletin is provided
together with the WECS-9520 update
tool.
Warning
The described work procedure is valid for
all engines running with WECS-9520
engine control system based on FCM-20
modules of hardware revisions 06 and 07.
Note
This tool is working only on Windows XP
and Windows 7 operating systems.
This Bulletin “Instructions I-28, Issue 4”
supersedes “Instructions I-28, Issue 3”,
dated June 22, 2015.
Contents
Page
1 Introduction 2
2 References 2
3 Required manpower 3
4 Preparations before installing and running the WECS-9520 SW update tool 3
5 WECS-9520 software update 5
6 Finalising the report 9
7 Appendix 9
8 Contacts 10
1 Introduction
This Bulletin is providing a step by step guidance to carry out the WECS-9520 software
update as explained in the Technical Bulletin RT-191.
In particular, the procedures for installing and running the WECS-9520 software update
tool are described and information on troubleshooting actions is provided.
The described work procedure is valid for all engines running with WECS-9520 engine
control system based on FCM-20 modules of hardware revisions 06 and 07.
WARNING:
Please ensure following conditions before the use of the software tool:
• The WECS-9520 software update tool shall only be used in port or other safe location.
• The WECS-9520 software update tool must only be run when the engine is in stand
still condition.
• The flexView PC has to be connected to the Online spare FCM-20#00:
E90 shipyard interface box, terminals 79 and 80, see also document C in Table 1 or
Appendix 4.
• The flexView PC is virus free. If in doubt, run an antivirus program first.
2 References
Table 1
3 Required manpower
To perform the WECS-9520 software update procedure, one person is needed and it
will take approximately one hour.
1 2
4 5
The application CRC value (4) is displayed on the flexView PLANT SW-INFO page (see
Figure 1). If the application CRC value (4) matches with the respective Software version
and build (Table 2: “Column A and B”), a software update is required, i.e. follow the
instructions as listed in Chapter 5.
INSTRUCTIONS
After successful software update, the modified CRC value is displayed as shown in
Figure 1, Position 5. The corresponding new CRC value is also listed in Table 2,
“Column C”.
INSTRUCTIONS
NOTE:
The WECS-9520 software update can be performed several times without any negative
effect.
NOTE:
The flexView program must be
closed before the installation is
started.
…
INSTRUCTIONS
NOTE:
The effective WECS-9520 software
update will start by clicking the
update button.
NOTE:
All WECS-9520 parameter settings
and all functions remain the same.
• Power off the complete WECS-9520 in the E85 box, wait for a minute and power on
again.
INSTRUCTIONS
NOTE:
When the WECS-9520 software update is successfully done it is not necessary to run it
again. It is permanently stored in the FCM-20 modules.
7 Appendix
1. Troubleshooting (Appendix 1)
2. Software auto-download to online spare FCM-20 Module (Appendix 2)
3. Instruction for flexView base and communication drivers installation (Appendix 3)
4. Wiring Diagram “flexView Operator” (Appendix 4)
INSTRUCTIONS
8 Contacts
8.1 How to contact Wärtsilä
For questions about the content of this Instructions bulletin, or if you need Wärtsilä
assistance, services, spare parts and/or tools, please contact your nearest Wärtsilä
representative.
Unless otherwise expressly set forth, no recommendation contained in this document or any of its appendices is to be construed as provided
due to a defect of the product, but merely as an improvement of the product and/or the maintenance procedures relating thereto. Any actions
by the owner/operator as a result of the recommendations are not covered under any warranty provided by Wärtsilä and such actions will
thus be at the owners/operators own cost and expense.
NO LIABILITY WHETHER DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL, IS ASSUMED WITH RESPECT TO THE
INFORMATION CONTAINED HEREIN. THIS PUBLICATION IS CONFIDENTIAL AND INTENDED FOR INFORMATION PURPOSES
ONLY.