0% found this document useful (0 votes)
841 views8 pages

Manual Tong Cat. IV

The inspection report summarizes the results of an inspection of a BV-100 Manual Tong Assembly with Asset No: 266046. The inspection found field welding on the jaw parts and parts from other OEMs like NOV and Rutong. As a result, the manual tong was rejected. The inspection included magnetic particle testing, dimensional inspection, and visual inspection and was performed by Mohamed Yasir according to applicable standards.

Uploaded by

Ranjith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
841 views8 pages

Manual Tong Cat. IV

The inspection report summarizes the results of an inspection of a BV-100 Manual Tong Assembly with Asset No: 266046. The inspection found field welding on the jaw parts and parts from other OEMs like NOV and Rutong. As a result, the manual tong was rejected. The inspection included magnetic particle testing, dimensional inspection, and visual inspection and was performed by Mohamed Yasir according to applicable standards.

Uploaded by

Ranjith
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

ALMANSOORI INSPECTION SERVICES

RIG EQUIPMENT INSPECTION REPORT

CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-001 DATE 01-Mar-2022 PAGE 1

LOCATION ADES-158 WORK ORDER NO./PURCHASE ORDER NO 5010051899


INSPECTION CATEGORY ACCEPTANCE API RP 7L/ OEM/CLIENT PN 70370-D -
INSPECTION STANDARD ASTM E 709/API RP 7L OEM PROC. NO.
Cat.lll Cat.lV X Client NA STANDARD Revision: 10

TYPE OF INSPECTION X MAGNETIC PARTICLE INSPECTION X DIMENSIONAL INSPECTION X VISUAL INSPECTION

DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 266046

MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A

Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS

Photo of item section with ID No. Manual tong rejected, Field welding found on the Jaw parts and Found parts from

other OEMs (NOV & Rutong)


INSPECTED AREA HIGHLIGHTED AS; Full Body
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
MODEL Ferrous Probe 72/2103 768/3102 QUALIFICATION: NDT LEVEL II SIGN:
BATCH # BATCH #

SER.NO. ACY-050 CALIPER SER.NO. VCG-1043 SIGNATURE & DATE:


INSPECTION TECHNIQUE Wet Visible Magnetic Particles Inspection STAMP
Abbreviations: SER.No= Serial Number,CONT= Contrast,MAG.PARTICLE= Magnetic Particle,W.CONTRAST= White Contrast
P.O. Box 109442 - Abu Dhabi - U.A.E. - Tel: +971-2-5543602 |Fax: +971-2-5543718 | E- Mail: [email protected]

F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong

CUSTOMER : ADES REPORT REF NO : 5010051899-MT-001

LOCATION : ADES-158 DATE : 01-Mar-2022

EQUIPMENT MODEL , CAPACITY & SIZE : BV-100 Manual Tong Assembly-B+V

IDENTIFICATION NO. : Asset No: 266046

COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS

Documentation Review

1 Do we have access to review Documentation delivered by the OEM? YES

2 Do we have OEM Manual to locate Wear data dimensional tolerance? YES

3 Do we have a Critical area diagram or instructions to locate critical areas? YES

4 Do we have OEM Manual to locate to General visual inspection requirements ? YES

Activity Records (Previous inspection records)

1 Have you verified the Records of previous CAT III and CAT IV inspection? YES

2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES

3 Have you checked for any actions recommended in the previous report? YES

4 Have you checked the location and extent of the repairs given in the previous report? YES

5 Have you checked for NDT inspection performed and the results of the inspection? YES

6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES

General Visual Inspection

1 Have you identified the Identification number and OEM Identification on the equipment? YES

2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES

3 Have you identified the category of inspection to be carried out based on previous inspection? YES

4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES

5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES

6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES

7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES

8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES

9 Have you checked for the Missing components, deterioration & Lubrication? YES

Magnetic Particle Inspection

1 Have you verified the surface to confirm adequate paint and foreign material removal? YES

2 Have you taken the photo as evidence of proper surface preparation? YES

Dimensional inspection

MIN MAX Measured Dimensions

1 PIN CLEARANCE (A) MAX 1.14 mm N/A

2 PIN CLEARANCE (A) MAX 1.14 mm N/A

3 PIN CLEARANCE (A) MAX 1.14 mm N/A

4 PIN CLEARANCE (A) MAX 1.14 mm N/A

5 PIN CLEARANCE (A) MAX 1.14 mm N/A

6 PLAY BETWEEN LEVER & JAW (B) MAX 1.12 mm N/A

Others ( Specify the method)

1 Did you notify the customer when the equipment rejected? YES

2 Have you received the client acknowledgement particularly for the rejected equipment? YES

COMMENTS :

Manual tong rejected, Field welding found on the Jaw parts and Found parts from other OEMs (NOV & Rutong)
NEAR MISS OBSERVATION ,IF ANY:

INSPECTOR NAME & SIGNATURE DATE: 01-Mar-2022


Mohamed Yasir
F.1620
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:[email protected], Web: www.almansoori.biz Rev.0
28.05.2020
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION REPORT

CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-002 DATE 01-Mar-2022 PAGE 1

LOCATION ADES-158 WORK ORDER NO./PURCHASE ORDER NO 5010051899


INSPECTION CATEGORY ACCEPTANCE API RP 7L/ OEM/CLIENT PN 70370-D -
INSPECTION STANDARD ASTM E 709/API RP 7L OEM PROC. NO.
Cat.lll Cat.lV X Client NA STANDARD Revision: 10

TYPE OF INSPECTION X MAGNETIC PARTICLE INSPECTION X DIMENSIONAL INSPECTION X VISUAL INSPECTION

DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 266045

MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A

Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS

Photo of item section with ID No. Manual tong rejected, Field welding found on the Jaw parts and Found parts from

other OEMs (NOV & Rutong)


INSPECTED AREA HIGHLIGHTED AS; Full Body
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
MODEL Ferrous Probe 72/2103 768/3102 QUALIFICATION: NDT LEVEL II SIGN:
BATCH # BATCH #

SER.NO. ACY-050 CALIPER SER.NO. VCG-1043 SIGNATURE & DATE:


INSPECTION TECHNIQUE Wet Visible Magnetic Particles Inspection STAMP
Abbreviations: SER.No= Serial Number,CONT= Contrast,MAG.PARTICLE= Magnetic Particle,W.CONTRAST= White Contrast
P.O. Box 109442 - Abu Dhabi - U.A.E. - Tel: +971-2-5543602 |Fax: +971-2-5543718 | E- Mail: [email protected]

F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong

CUSTOMER : ADES REPORT REF NO : 5010051899-MT-002

LOCATION : ADES-158 DATE : 01-Mar-2022

EQUIPMENT MODEL , CAPACITY & SIZE : BV-100 Manual Tong Assembly-B+V

IDENTIFICATION NO. : Asset No: 266045

COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS

Documentation Review

1 Do we have access to review Documentation delivered by the OEM? YES

2 Do we have OEM Manual to locate Wear data dimensional tolerance? YES

3 Do we have a Critical area diagram or instructions to locate critical areas? YES

4 Do we have OEM Manual to locate to General visual inspection requirements ? YES

Activity Records (Previous inspection records)

1 Have you verified the Records of previous CAT III and CAT IV inspection? YES

2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES

3 Have you checked for any actions recommended in the previous report? YES

4 Have you checked the location and extent of the repairs given in the previous report? YES

5 Have you checked for NDT inspection performed and the results of the inspection? YES

6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES

General Visual Inspection

1 Have you identified the Identification number and OEM Identification on the equipment? YES

2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES

3 Have you identified the category of inspection to be carried out based on previous inspection? YES

4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES

5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES

6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES

7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES

8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES

9 Have you checked for the Missing components, deterioration & Lubrication? YES

Magnetic Particle Inspection

1 Have you verified the surface to confirm adequate paint and foreign material removal? YES

2 Have you taken the photo as evidence of proper surface preparation? YES

Dimensional inspection

MIN MAX Measured Dimensions

1 PIN CLEARANCE (A) MAX 1.14 mm N/A

2 PIN CLEARANCE (A) MAX 1.14 mm N/A

3 PIN CLEARANCE (A) MAX 1.14 mm N/A

4 PIN CLEARANCE (A) MAX 1.14 mm N/A

5 PIN CLEARANCE (A) MAX 1.14 mm N/A

6 PLAY BETWEEN LEVER & JAW (B) MAX 1.12 mm N/A

Others ( Specify the method)

1 Did you notify the customer when the equipment rejected? YES

2 Have you received the client acknowledgement particularly for the rejected equipment? YES

COMMENTS :

Manual tong rejected, Field welding found on the Jaw parts and Found parts from other OEMs (NOV & Rutong)
NEAR MISS OBSERVATION ,IF ANY:

INSPECTOR NAME & SIGNATURE DATE: 01-Mar-2022


Mohamed Yasir
F.1620
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:[email protected], Web: www.almansoori.biz Rev.0
28.05.2020
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION REPORT

CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-003 DATE 01-Mar-2022 PAGE 1

LOCATION ADES-158 WORK ORDER NO./PURCHASE ORDER NO 5010051899


INSPECTION CATEGORY ACCEPTANCE API RP 7L/ OEM/CLIENT PN 70370-D -
INSPECTION STANDARD ASTM E 709/API RP 7L OEM PROC. NO.
Cat.lll Cat.lV X Client NA STANDARD Revision: 10

TYPE OF INSPECTION X MAGNETIC PARTICLE INSPECTION X DIMENSIONAL INSPECTION X VISUAL INSPECTION

DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 282638

MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A

Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS

Photo of item section with ID No. Manual tong rejected, Field welding found on the Jaw parts and Found parts from

other OEMs (NOV)


INSPECTED AREA HIGHLIGHTED AS; Full Body
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
MODEL Ferrous Probe 72/2103 768/3102 QUALIFICATION: NDT LEVEL II SIGN:
BATCH # BATCH #

SER.NO. ACY-050 CALIPER SER.NO. VCG-1043 SIGNATURE & DATE:


INSPECTION TECHNIQUE Wet Visible Magnetic Particles Inspection STAMP
Abbreviations: SER.No= Serial Number,CONT= Contrast,MAG.PARTICLE= Magnetic Particle,W.CONTRAST= White Contrast
P.O. Box 109442 - Abu Dhabi - U.A.E. - Tel: +971-2-5543602 |Fax: +971-2-5543718 | E- Mail: [email protected]

F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong

CUSTOMER : ADES REPORT REF NO : 5010051899-MT-003

LOCATION : ADES-158 DATE : 03-Mar-2022

EQUIPMENT MODEL , CAPACITY & SIZE : BV-100 Manual Tong Assembly-B+V

IDENTIFICATION NO. : Asset No: 282638

COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS

Documentation Review

1 Do we have access to review Documentation delivered by the OEM? YES

2 Do we have OEM Manual to locate Wear data dimensional tolerance? YES

3 Do we have a Critical area diagram or instructions to locate critical areas? YES

4 Do we have OEM Manual to locate to General visual inspection requirements ? YES

Activity Records (Previous inspection records)

1 Have you verified the Records of previous CAT III and CAT IV inspection? YES

2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES

3 Have you checked for any actions recommended in the previous report? YES

4 Have you checked the location and extent of the repairs given in the previous report? YES

5 Have you checked for NDT inspection performed and the results of the inspection? YES

6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES

General Visual Inspection

1 Have you identified the Identification number and OEM Identification on the equipment? YES

2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES

3 Have you identified the category of inspection to be carried out based on previous inspection? YES

4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES

5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES

6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES

7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES

8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES

9 Have you checked for the Missing components, deterioration & Lubrication? YES

Magnetic Particle Inspection

1 Have you verified the surface to confirm adequate paint and foreign material removal? YES

2 Have you taken the photo as evidence of proper surface preparation? YES

Dimensional inspection

MIN MAX Measured Dimensions

1 PIN CLEARANCE (A) MAX 1.14 mm N/A

2 PIN CLEARANCE (A) MAX 1.14 mm N/A

3 PIN CLEARANCE (A) MAX 1.14 mm N/A

4 PIN CLEARANCE (A) MAX 1.14 mm N/A

5 PIN CLEARANCE (A) MAX 1.14 mm N/A

6 PLAY BETWEEN LEVER & JAW (B) MAX 1.12 mm N/A

Others ( Specify the method)

1 Did you notify the customer when the equipment rejected? YES

2 Have you received the client acknowledgement particularly for the rejected equipment? YES

COMMENTS :

Manual tong rejected, Field welding found on the Jaw parts and Found parts from other OEMs (NOV)
NEAR MISS OBSERVATION ,IF ANY:

INSPECTOR NAME & SIGNATURE DATE: 03-Mar-2022


Mohamed Yasir
F.1620
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:[email protected], Web: www.almansoori.biz Rev.0
28.05.2020
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION REPORT

CUSTOMER Advance Energy Systems REPORT NO. 5010051899-MT-004 DATE 01-Mar-2022 PAGE 1

LOCATION ADES-158 WORK ORDER NO./PURCHASE ORDER NO 5010051899


INSPECTION CATEGORY ACCEPTANCE API RP 7L/ OEM/CLIENT PN 70370-D -
INSPECTION STANDARD ASTM E 709/API RP 7L OEM PROC. NO.
Cat.lll Cat.lV X Client NA STANDARD Revision: 10

TYPE OF INSPECTION X MAGNETIC PARTICLE INSPECTION X DIMENSIONAL INSPECTION X VISUAL INSPECTION

DESCRIPTION OF ITEM BV-100 Manual Tong Assembly IDENTIFICATION NUMBER Asset No: 167007

MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PIN CLEARANCE (A) N/A MAX 1.14 mm N/A
PLAY BETWEEN LEVER & JAW (B) N/A MAX 1.12 mm N/A

Manufacturer: B+V(Forum) Size & Model : BV-100 Capacity: N/A INSPECTION RESULT/ COMMENTS

Photo of item section with ID No.


Manual tong rejected, Found parts from other OEMs (NOV)
INSPECTED AREA HIGHLIGHTED AS; Full Body
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
MODEL Ferrous Probe 72/2103 768/3102 QUALIFICATION: NDT LEVEL II SIGN:
BATCH # BATCH #

SER.NO. ACY-050 CALIPER SER.NO. VCG-1043 SIGNATURE & DATE:


INSPECTION TECHNIQUE Wet Visible Magnetic Particles Inspection STAMP
Abbreviations: SER.No= Serial Number,CONT= Contrast,MAG.PARTICLE= Magnetic Particle,W.CONTRAST= White Contrast
P.O. Box 109442 - Abu Dhabi - U.A.E. - Tel: +971-2-5543602 |Fax: +971-2-5543718 | E- Mail: [email protected]

F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Manual Tong

CUSTOMER : ADES REPORT REF NO : 5010051899-MT-004

LOCATION : ADES-158 DATE : 03-Mar-2022

EQUIPMENT MODEL , CAPACITY & SIZE : BV-100 Manual Tong Assembly-B+V

IDENTIFICATION NO. : Asset No: 167007

COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS

Documentation Review

1 Do we have access to review Documentation delivered by the OEM? YES

2 Do we have OEM Manual to locate Wear data dimensional tolerance? YES

3 Do we have a Critical area diagram or instructions to locate critical areas? YES

4 Do we have OEM Manual to locate to General visual inspection requirements ? YES

Activity Records (Previous inspection records)

1 Have you verified the Records of previous CAT III and CAT IV inspection? YES

2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES

3 Have you checked for any actions recommended in the previous report? YES

4 Have you checked the location and extent of the repairs given in the previous report? YES

5 Have you checked for NDT inspection performed and the results of the inspection? YES

6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES

General Visual Inspection

1 Have you identified the Identification number and OEM Identification on the equipment? YES

2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES

3 Have you identified the category of inspection to be carried out based on previous inspection? YES

4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES

5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES

6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES

7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES

8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES

9 Have you checked for the Missing components, deterioration & Lubrication? YES

Magnetic Particle Inspection

1 Have you verified the surface to confirm adequate paint and foreign material removal? YES

2 Have you taken the photo as evidence of proper surface preparation? YES

Dimensional inspection

MIN MAX Measured Dimensions

1 PIN CLEARANCE (A) MAX 1.14 mm N/A

2 PIN CLEARANCE (A) MAX 1.14 mm N/A

3 PIN CLEARANCE (A) MAX 1.14 mm N/A

4 PIN CLEARANCE (A) MAX 1.14 mm N/A

5 PIN CLEARANCE (A) MAX 1.14 mm N/A

6 PLAY BETWEEN LEVER & JAW (B) MAX 1.12 mm N/A

Others ( Specify the method)

1 Did you notify the customer when the equipment rejected? YES

2 Have you received the client acknowledgement particularly for the rejected equipment? YES

COMMENTS :

Manual tong rejected, Found parts from other OEMs (NOV)


NEAR MISS OBSERVATION ,IF ANY:

INSPECTOR NAME & SIGNATURE DATE: 03-Mar-2022


Mohamed Yasir
F.1620
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:[email protected], Web: www.almansoori.biz Rev.0
28.05.2020

You might also like