IP To Modulator
IP To Modulator
User's Manual
Dear clients,
In order to give better play to the function of your device, we suggest that you take the precious
time to read the user manual carefully before connecting and operating the device, so that you can
master the use method and use points of the device.
Please keep this manual for future reference.
NX0416 user's manual
Contents
1. Introduction ............................................................. 3
2. Operation ............................................................... 6
2 / 12
NX0416 user's manual
1. Introduction
3 / 12
NX0416 user's manual
1.3 Specifications
Standard EN300744
FFT mode 2K
Constellation QPSK、16QAM、64QAM
MER ≥40db
Dimension
440mm×380mm×40mm
(W*D*H)
Temperature 0~45℃(work);-20~80℃(storage)
General
AC 110V±10%,50/60Hz
Power supply
AC 220V±10%,50/60Hz
4 / 12
NX0416 user's manual
1.4 Interface
6 Power Switch
5 / 12
NX0416 user's manual
2. Operation
2.1 Installation
Check the possible loss or damage of the equipment during transportation before installing the
equipment; Prepare the appropriate environment, connect > to the signal line, connect > to the power
line, open the device, >, check the IP address of the network manager, >, adjust the network manager
server, connect > to the network manager, check or modify all parameters, and then the device will
be normally used after no abnormalities are found in >.
Note 1: the power supply must meet the working requirements of the equipment, such as
voltage, frequency and power supply capacity.
Note 2: please observe the environment before the test and pay attention to safety during the
test.
2.2 Connect
⚫ Set the computer and the device IP in the same network segment according to the device network
manager address (192.168.0.136)
⚫ The IP address of the computer cannot be the same as that of the device
⚫ In the address bar of Firefox browser, ENTER: 192.168.0.136 and press "ENTER". ENTER the
user name: admin password: admin and ENTER the configuration window of the digital TV
modulator.
6 / 12
NX0416 user's manual
The input interface is on the left and the output interface is on the right
In the TS stream setting column, parameters of the output channel can be set: stream selection,
general parameters, PID transparent transmission. Mainly is carries on the choice to the output
program.
In this interface, you can click the "+" button and input the corresponding IP address to add the input
program source.
After the program source is added into the device as required, the selected program can be output or
deleted through the arrow to the right and left of ">" "<" ">>" "<<".
7 / 12
NX0416 user's manual
8 / 12
NX0416 user's manual
2.3.5 Configuration
Save or restore the device system configuration, or load other configuration parameters
9 / 12
NX0416 user's manual
2.3.6 LOG
10 / 12
NX0416 user's manual
3. Trouble Removal
Check that the input voltage and connection of the power supply
boot failure
operating range are correct
The program name and program number of the output signal are
Program Scan failure
manually added in the TS stream setting
11 / 12
NX0416 user's manual
4. Packing list
12 / 12