0% found this document useful (0 votes)
69 views3 pages

12V 100ah 12V 115ah Deep Cycle Series: Technical Dimensions (MM)

ULTRACELL UC100
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views3 pages

12V 100ah 12V 115ah Deep Cycle Series: Technical Dimensions (MM)

ULTRACELL UC100
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

UC100-12E

12V 100Ah (C10)


12V 115Ah (C100)
Deep Cycle Series

220±2
17

2 330±2

28.2 kg
Approx

Technical Dimensions (mm)

220±2 173±2
212±2

330±2

Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] UC-V1-REV1 06/20
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Image Terminal Dimensions (mm)

Standard Optional
Terminal: F11 Terminal: F10

8.5
16
Ø20

17

7 Ø6

M8
8

Technical Specification
Output Nominal Voltage 12V
Nominal Capacity (10HR) 100Ah
Terminal Type Standard Terminal F11
Optional Terminal F10
Container Material Standard Option ABS
Flame Retardant Option (FR) ABS (UL94:VO)
Rated Capacity (20HR 1.80V/cell, 25°C) 103.0 Ah/5.15A
(10HR 1.80V/cell, 25°C) 100.0 Ah/10.0A
(5HR 1.75V/cell, 25°C) 89.0 Ah/17.8A
(3HR 1.75V/cell, 25°C) 81.3 Ah/27.1A
(1HR 1.60V/cell, 25°C) 62.5 Ah/62.5A

Max Discharge Current 1000A (5s)


Internal Resistance Approx 4.9mΩ
12V 100Ah (C10)
12V 115Ah (C100)
Deep Cycle Series
UC100-12E

Discharge Characteristics Operating Temp Range Discharge: -15 ~ 50°C


Charge: 0 ~ 40°C
Storage: -15 ~ 40°C
Nominal Operating Temp Range 25 ± 3°C
Cycle Use Initial Charging Current less than 30A.
Voltage 14.4V ~ 15.0V @ 25°C Temp. Coefficient -30mV/°C
Standby Use No limit on initial charging current.
Voltage 13.5V ~ 13.8V @ 25°C Temp. Coefficient -20mV/°C
Capacity affected by Temperature 40°C 103%
25°C 100%
0°C 86%
Design Floating Life at 20°C 8 Years

Self Discharge
Ultracell® UC batteries may be stored for up to 6 months at 25°C and then a refresh charge is required. For higher
temperatures the time intervals will be shorter.

Constant Current Discharge / Constant Power Discharge At 25°C (Amperes & Watts/Cell)
A = Amperes W = Watts

F.V/TIME 5 10 15 20 30 45 60 90 2 3 4 5 6 8 10 20
EMC 1188-C
A min min min min min min min min hours hours hours hours hours hours hours hours
W
195.7 139.2 125.7 98.9 88.4 64.6 54.7 39.7 33.4 24.5 19.2 16.7 14.7 11.3 9.36 4.96
1.85V/cell
365.6 261.8 238.0 188.0 168.9 124.3 105.9 77.0 64.9 47.8 37.7 32.8 29.0 22.4 18.6 9.89
222.6 158.0 142.4 111.8 96.2 68.5 56.7 41.0 34.4 26.6 20.5 17.5 15.8 11.9 10.0 5.15
1.80V/cell
408.9 292.9 266.2 210.3 182.4 130.8 109.1 79.2 66.7 51.7 40.1 34.4 31.1 23.5 19.5 10.2
241.8 171.3 154.2 120.7 98.2 71.0 59.5 43.1 36.3 27.1 20.9 17.8 15.9 11.9 10.1 5.20
1.75V/cell
436.5 312.6 284.1 224.5 184.7 134.7 114.0 82.9 69.9 52.5 40.7 34.9 31.2 23.6 19.6 10.3
258.5 182.7 163.8 127.9 100.2 72.4 60.7 44.0 37.0 27.6 21.2 18.1 16.0 12.1 10.2 5.25
1.70V/cell
458.8 328.6 298.7 236.0 186.8 136.5 115.6 84.1 71.0 53.3 41.2 35.3 31.3 23.9 19.8 10.4
267.5 188.5 168.6 131.4 101.6 73.4 61.6 44.6 37.5 27.9 21.6 18.5 16.1 12.3 10.3 5.31
1.67V/cell
466.3 334.0 303.6 239.8 188.2 137.7 116.7 84.9 71.8 53.6 41.7 35.9 31.4 24.2 20.0 10.5
277.0 194.9 173.8 134.8 103.1 74.5 62.5 45.3 38.1 28.1 21.8 18.8 16.2 12.5 10.4 5.38
1.60V/cell
472.8 338.7 307.8 243.2 189.0 138.4 117.5 85.6 72.3 53.8 42.0 36.3 31.5 24.5 20.2 10.6

Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] UC-V1-REV1 06/20
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Discharge Characteristics Float Charging Characteristics
Charge Charging Charging
Volume Current Voltage
12V
Temperature: 25ºC % (XCA) (V) 0.10CA-2.25V/cell Temperature: 25ºC
13.0

0.25
12.0 120 15.0 Charged Volume
110
0.20

Terminal Voltage (V)


100
11.0 14.0
90 Charge Voltage
0.1C 0.05C 80
0.2C 0.15 (Constant 2.25v/cell)
10.0 0.4C 70 13.0
60
0.6C After 50% Discharge
1C 50 0.10
9.0 12.0
40 After 100% Discharge
30
0.05 11.0
8.0 20
2C 10 Charging Current
0 0
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 4 8 12 16 20 24 28 32 36 40
Min H
Discharge Time Charging Time (hours)

Temperature Effects in Relation to Battery Capacity Effects of Temperature on Long Term Float Life

120 10
0.1CA

100
0.17CA 8

Float Life (years)


80 0.25CA
Capacity (%)

60

4
40

2
20

0
-20 -10 0 10 20 30 40 50 60
20 25 30 35 40 45 50

Temperature (ºC) Battery Temperature (ºC)


12V 100Ah (C10)
12V 115Ah (C100)
Deep Cycle Series
UC100-12E

EMC 1188-C

Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] UC-V1-REV1 06/20
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

You might also like