12V 100ah 12V 115ah Deep Cycle Series: Technical Dimensions (MM)
12V 100ah 12V 115ah Deep Cycle Series: Technical Dimensions (MM)
220±2
17
3±
2 330±2
28.2 kg
Approx
220±2 173±2
212±2
330±2
Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] UC-V1-REV1 06/20
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Image Terminal Dimensions (mm)
Standard Optional
Terminal: F11 Terminal: F10
8.5
16
Ø20
17
7 Ø6
M8
8
Technical Specification
Output Nominal Voltage 12V
Nominal Capacity (10HR) 100Ah
Terminal Type Standard Terminal F11
Optional Terminal F10
Container Material Standard Option ABS
Flame Retardant Option (FR) ABS (UL94:VO)
Rated Capacity (20HR 1.80V/cell, 25°C) 103.0 Ah/5.15A
(10HR 1.80V/cell, 25°C) 100.0 Ah/10.0A
(5HR 1.75V/cell, 25°C) 89.0 Ah/17.8A
(3HR 1.75V/cell, 25°C) 81.3 Ah/27.1A
(1HR 1.60V/cell, 25°C) 62.5 Ah/62.5A
Self Discharge
Ultracell® UC batteries may be stored for up to 6 months at 25°C and then a refresh charge is required. For higher
temperatures the time intervals will be shorter.
Constant Current Discharge / Constant Power Discharge At 25°C (Amperes & Watts/Cell)
A = Amperes W = Watts
F.V/TIME 5 10 15 20 30 45 60 90 2 3 4 5 6 8 10 20
EMC 1188-C
A min min min min min min min min hours hours hours hours hours hours hours hours
W
195.7 139.2 125.7 98.9 88.4 64.6 54.7 39.7 33.4 24.5 19.2 16.7 14.7 11.3 9.36 4.96
1.85V/cell
365.6 261.8 238.0 188.0 168.9 124.3 105.9 77.0 64.9 47.8 37.7 32.8 29.0 22.4 18.6 9.89
222.6 158.0 142.4 111.8 96.2 68.5 56.7 41.0 34.4 26.6 20.5 17.5 15.8 11.9 10.0 5.15
1.80V/cell
408.9 292.9 266.2 210.3 182.4 130.8 109.1 79.2 66.7 51.7 40.1 34.4 31.1 23.5 19.5 10.2
241.8 171.3 154.2 120.7 98.2 71.0 59.5 43.1 36.3 27.1 20.9 17.8 15.9 11.9 10.1 5.20
1.75V/cell
436.5 312.6 284.1 224.5 184.7 134.7 114.0 82.9 69.9 52.5 40.7 34.9 31.2 23.6 19.6 10.3
258.5 182.7 163.8 127.9 100.2 72.4 60.7 44.0 37.0 27.6 21.2 18.1 16.0 12.1 10.2 5.25
1.70V/cell
458.8 328.6 298.7 236.0 186.8 136.5 115.6 84.1 71.0 53.3 41.2 35.3 31.3 23.9 19.8 10.4
267.5 188.5 168.6 131.4 101.6 73.4 61.6 44.6 37.5 27.9 21.6 18.5 16.1 12.3 10.3 5.31
1.67V/cell
466.3 334.0 303.6 239.8 188.2 137.7 116.7 84.9 71.8 53.6 41.7 35.9 31.4 24.2 20.0 10.5
277.0 194.9 173.8 134.8 103.1 74.5 62.5 45.3 38.1 28.1 21.8 18.8 16.2 12.5 10.4 5.38
1.60V/cell
472.8 338.7 307.8 243.2 189.0 138.4 117.5 85.6 72.3 53.8 42.0 36.3 31.5 24.5 20.2 10.6
Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] UC-V1-REV1 06/20
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Discharge Characteristics Float Charging Characteristics
Charge Charging Charging
Volume Current Voltage
12V
Temperature: 25ºC % (XCA) (V) 0.10CA-2.25V/cell Temperature: 25ºC
13.0
0.25
12.0 120 15.0 Charged Volume
110
0.20
Temperature Effects in Relation to Battery Capacity Effects of Temperature on Long Term Float Life
120 10
0.1CA
100
0.17CA 8
60
4
40
2
20
0
-20 -10 0 10 20 30 40 50 60
20 25 30 35 40 45 50
EMC 1188-C
Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] UC-V1-REV1 06/20
www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE