RCE Series: Digital Pressure Transducers
RCE Series: Digital Pressure Transducers
FEATURES
MEDIA COMPATIBILITY
To be used with non-corrosive, non-ionic working
fluids such as clean dry air, dry gases and the like.
Output current
Sink 2 mA
Source 2 mA 6 CLK
5 I/C
Lead temperature (2 - 4 sec.) 250°C 4 SS
3 GND
Temperature ranges 2 +Vs
Compensated 0 to +85 °C 1 MISO
Operating -10 to +85 °C
Storage -20 to +105 °C
Pin 1
marked by dot
Caution!
The sensor is not reverse polarity protected. Note: Pin 5 is an internal device connection and
should not be connected for any reason!
Incorrect applications of excitationvoltage or ground to
the wrong pin can cause electrical failure. MOSI is internally connected to high level.
No external port is available.
Application of supply voltage above themaximum can
cause electrical failure.
www.sensortechnics.com
RCE Series
Digital pressure transducers
Specification notes:
1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may
fracture.
2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
3. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects.
Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within
the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and
full scale from nominal values.
4. Delay time between sampling and signal change at the output.
www.sensortechnics.com
RCE Series
Digital pressure transducers
PERFORMANCE CHARACTERISTICS
The output signal is not ratiometric to the supply voltage (VS = 5.0 VDC, TA = 25°C)
All RCE...(U,R)
All RCE...B
All devices
www.sensortechnics.com
RCE Series
Digital pressure transducers
INTRODUCTION
The RCE is capable to generate a digital output signal. In general the RCE supports all combinations of clock
The device runs a cyclic program, which will store a phase (CPHA) and polarity (CPOL). By default it is
corrected sensor value with 12-bit resolution about every programmed to CPHA = 0 and CPOL = 0, which means
250 µs within the output registers of the internal ASIC. This that the data is latched with the rising edge of the clock.
cyclic program runs independent from the bus
communication. In order to use the RCE pressure sensor Slave select:
for digital signal readout, it should be connected to a SPI
The falling edge of the SS line indicates the beginning of
Master device.
the transfer. Additionally the SS line must not be negated
SPI specifies four signals: The clock (CLK) is generated
by the master and input to all slaves. MOSI carries data and reasserted between the three bytes to be transmitted.
from master to slave. MISO carries data from slave back to
master. A slave select line (SS) allows individual selection Data operation:
of a slave device. The MOSI is internally connected to high level. So there is
no data transmission from master to slave. Because of
internal configuration the slave will answer the first byte
DIGITAL INTERFACE with an FFxh. The second and third byte contain the 15 bit
SPI Modes: pressure information (see below).
A pair of parameters called clock polarity (CPOL) and clock
phase (CPHA) determine the edges of the clock signal on
which the data are driven and sampled. Each of the two
parameters has two possible states, which allows for four
possible combinations, all of which are incompatible with
one another.
www.sensortechnics.com
RCE Series
Digital pressure transducers
PHYSICAL DIMENSIONS
1.10 ref
(27.9 ref 1.03 ref
0.85 (26.2) ref
(21.6)
0.55
0.80
(20.3) (14.0)
0.36
(9.1)
0.190
1.08 (4.8)
(27.4) 2 pls
0.41 Ø 0.14 (3.6) thru rivet
(10.4) mounting holes
1 2 3 4 5 6
0.05
0.25 (1.3)
(6.4)
0.20
0.42
(10.7)
(5.1) Port A:
High pressure Port for
R0.13 absolute devices
(R3.3) typ
www.sensortechnics.com
RCE Series
Digital pressure transducers
ORDERING INFORMATION
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
www.sensortechnics.com