0% found this document useful (0 votes)
37 views2 pages

Heating System Schematic: Systems Operation

Uploaded by

Buku Digital
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views2 pages

Heating System Schematic: Systems Operation

Uploaded by

Buku Digital
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Shutdown SIS

Previous Screen

Product:  WHEEL LOADER 
Model:  926 WHEEL LOADER 94Z 
Configuration: 926 WHEEL LOADER 94Z00001-02208 (MACHINE) POWERED BY 3204 ENGINE 

Systems Operation
Air Conditioning and Heating R-12 All Caterpillar Machines
Media Number -SENR3334-02 Publication Date -01/08/2002 Date Updated -23/08/2002 
 
 
i01727937

Heating System Schematic


SMCS - 7304

Illustration 1 g00343853

Heating System

(1) Heater coil

(2) Heater Control Valve

(3) Outlet supply connection for the coolant

(4) Return connection for the coolant

The heating system uses the coolant from the engine cooling system. The heater control valve (2) is
connected to the temperature control knob in the cab. With the temperature control knob in the OFF
position, the heater control valve prevents the flow of the coolant through the heater coil (1). When
the control knob is moved from the OFF position the control valve (2) will open. The control valve
allows coolant that is warm to flow from the outlet (3) through the control valve (2) to the heater coil
(1). As the warm coolant flows through the heater coil, the temperature of the air flow across the
heater coil increases.

The temperature of the heater is controlled by the amount of coolant that flows through the heater
coil. The increase of the coolant flow through the heater coil will increase the temperature of the air
that flows across the heater coil. The coolant from the heater coil will flow to the return connection
(4). Then, the coolant is sent back through the engine cooling system.

Copyright 1993 - 2020 Caterpillar Inc.  Mon Sep 14 01:08:53 UTC+0700 2020 
All Rights Reserved. 
Private Network For SIS Licensees. 

You might also like