0% found this document useful (0 votes)
93 views12 pages

200 A 600 V Standard Enclosure: BQ2 Series

The document provides specifications for the BQ2 Series 200 Amp 600 Volt meter sockets. It includes details on the conductor range, aluminum tunnel type connectors for load and line sides, and that it is for overhead, underground, and combination overhead/underground applications. It then lists the various catalog numbers and descriptions for the different models that vary based on features like having ground lugs or hub openings. Diagrams show the dimensions and layout of the overhead, underground, and combination bottom configurations.

Uploaded by

PRABHU SHANKAR M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views12 pages

200 A 600 V Standard Enclosure: BQ2 Series

The document provides specifications for the BQ2 Series 200 Amp 600 Volt meter sockets. It includes details on the conductor range, aluminum tunnel type connectors for load and line sides, and that it is for overhead, underground, and combination overhead/underground applications. It then lists the various catalog numbers and descriptions for the different models that vary based on features like having ground lugs or hub openings. Diagrams show the dimensions and layout of the overhead, underground, and combination bottom configurations.

Uploaded by

PRABHU SHANKAR M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

D18 MICROLECTRIC METER SOCKETS


BQ2 Series
200 A 600 V; standard enclosure

Product specifications • Supplied with screw type ring


• Conductor range: 6 AWG–250 kcmil • Weatherproof Type 3R enclosure
• Aluminum tunnel type connectors for both load • Primarily used in: All provinces
and line sides Note: Supply from an underground network often requires use of stud
• For overhead, underground and combination type connector. Consult your local utility.

overhead/underground
Approved for copper
or aluminum

Dimensions (in.) Weight each


Cat. no Description H W D lb kg
BQ2-V 4 Jaw
BQ2-V Overhead, hub opening 15 5⁄8 8 47⁄64 513⁄32 12 5.4
BQ2-VGN Overhead opening comes with ground lug on 15 5⁄8 8 47⁄64 513⁄32 12 5.4
neutral
BQ2-VGN-CR Overhead comes with ground lug on neutral, 15 5⁄8 8 47⁄64 513⁄32 12 5.4
corrosion resistant
BQ2-1 1/2 V Overhead, hub opening, comes with 11⁄2 in. hub 15 5⁄8 8 47⁄64 513⁄32 12 5.4
BQ2-2V Overhead, hub opening, comes with 2 in. hub 15 5⁄8 8 47⁄64 513⁄32 12 5.4
BQ2-2VGN Overhead , hub opening comes with 1 ½” hub 15 5⁄8 8 47⁄64 513⁄32 12 5.4
and ground lug on neutral
BQ2-TV Underground 15 5⁄8 8 47⁄64 513⁄32 12 5.4
BQ2-TVGN Underground comes with ground lug on neutral 15 ⁄8
5
8 ⁄64
47
513⁄32 12 5.4
BQ2-TCV Combination, overhead-underground 15 5⁄8 8 47⁄64 513⁄32 12 5.4
BQ2-TCV-CR Combination overhead-underground, 15 5⁄8 8 47⁄64 513⁄32 12 5.4
corrosion resistant
BQ2-TCVGN Combination overhead-underground comes 15 5⁄8 8 47⁄64 513⁄32 12 5.4
with ground lug on neutral
BQ2-TCVGN-CR Combination overhead-underground comes 15 5⁄8 8 47⁄64 513⁄32 12 5.4
with ground lug on neutral , corrosion resistant
BQ2-22VNH Overhead, twin hub opening 15 5⁄8 8 47⁄64 513⁄32 12 5.4
BQ2-22VNHGN Overhead , twin hub opening comes with 15 5⁄8 8 47⁄64 513⁄32 12 5.4
ground lug on neutral
BQ2-2VGN-CR Overhead comes with ground lug on neutral, 15 5⁄8 8 47⁄64 513⁄32 12 5.4
corrosion resistant
BQ2-22V Overhead, twin hub opening, 15 5⁄8 8 47⁄64 513⁄32 12 5.4
comes with 2 in. hubs
BQ2-22VGN Overhead, twin hub opening comes with 2 in 15 5⁄8 8 47⁄64 513⁄32 12 5.4
hubs and ground lug on neutral
Factory-installed accessories
Include: -GN Ground lug on neutral
-5 5th jaw standard capacity
-6 5th jaw full capacity, 6 o’clock position
BQ2 SERIES D19


BQ2 Series
200 A 600 V; standard enclosure

Diagrams

5 13⁄32 in.

Trade size Trade size


knockout knockout
1 1⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in. 1 1⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in.
2 places 2 places

⁄64 in.
29

2 1⁄4 in. 27⁄32 in.


⁄8 in.
7
1 1⁄32 in.
2 1⁄8 in.
KO 1⁄4 in.
4 3⁄8 in.
3 17⁄64 in. KO 1⁄2 in.
Trade size
1 ⁄16 in.
13
3 ⁄4 in.
3

5 5⁄16 in. Combination and underground bottom Overhead bottom


D20 MICROLECTRIC METER SOCKETS


BP2-TV
200 A 600 V; standard enclosure

Product specifications • For underground service only


• Conductor range: 6 AWG–250 kcmil • Supplied with screw type ring
• Aluminum tunnel type connectors for both load • Weatherproof Type 3R enclosure
and line sides • Primarily used in: Ontario

Approved for copper


or aluminum

Dimensions (in.) Weight each


Cat. no. Description H W D lb kg
BP2-TV BP2-TV Underground 20 12 57⁄16 16.5 7.48

Diagrams
5 7⁄16 in.

Trade size Trade size Trade size


knockout knockout knockout
1 1⁄4 , 1 1⁄2 , 2 1
⁄2 in. 1
⁄4 in.
and 2 1⁄2 in.
3 sets

⁄16 in.
7

2 3⁄16 in.

17⁄8 in.
3 13⁄16 in.
13
⁄16 in.
3 13⁄16 in.
2 13⁄16 in.
12 in.

2 3⁄8 in.
B P 2 -T V, B S 2 S E R I E S D21


BS2 Series
200 A 600 V; oversize enclosure

Product specifications • Supplied with screw type ring


• Conductor range: 6 AWG–250 kcmil • Weatherproof Type 3R enclosure
• Aluminum tunnel type connectors for both load • Primarily used in: B.C., AB, Sask., Man., Ont., N.S.
and line sides NOTE: Supply from an underground network often requires use of stud
• For overhead, underground and combination type connector. Consult your local utility.

overhead/underground

Approved for copper


or aluminum

Dimensions (in.) Weight each


Cat. no. Description H W D lb kg
BS2-V 4 Jaw
BS2-V Overhead, hub opening 171⁄8 12 57⁄16 14 6.3
BS2-INV Overhead , hub opening comes 17 ⁄8
1
12 57⁄16 14 6.3
with insolated neutral
BS2-1 1/2 V Overhead, hub opening, comes with 11⁄2 in. hub 171⁄8 12 57⁄16 14 6.3
BS2-2V Overhead, hub opening, comes with 2 in. hub 17 ⁄8
1
12 5 ⁄16
7
14 6.3
BS2-TV Underground 171⁄8 12 57⁄16 14 6.3
BS2-INTV Underground comes with isolated neutral 171⁄8 12 57⁄16 14 6.3
BS2-TCV Combination, overhead-underground 171⁄8 12 57⁄16 14 6.3

BS2-INTCV Combination overhead-underground comes with 171⁄8 12 57⁄16 14 6.3


isolated neutral
BS2-TCVGN Combination overhead-underground comes with 171⁄8 12 57⁄16 14 6.3
ground lug on neutral
BS2-TCVBC Combination, overhead-underground 171⁄8 12 57⁄16 14 6.3
comes with 3” ko
BS2-TCVBC-CR Combination overhead-underground 171⁄8 12 57⁄16 14 6.3
comes with 3” ko
BS2-TCVBCGN Combination overhead-underground comes with 171⁄8 12 57⁄16 14 6.3
ground lug on neutral
BS2-22VNH Overhead, twin hub opening 171⁄8 12 57⁄16 14 6.3
BS2-22V Overhead, twin hub opening, comes with 2 in. hubs 171⁄8 12 57⁄16 14 6.3
BS2-9V Overhead, hub opening, comes with 5 jaw,
th
17 ⁄8
1
12 5 ⁄16
7
14 6.3
9 o’clock and insulated neutral
Factory-installed accessories
Include: -5 5th jaw, standard capacity, 9 o’clock position
-6 5th jaw, full capacity, 6 o’clock position
-9 5th jaw, full capacity, 9 o’clock position
-IN Insulated neutral
-GN Ground lug on neutral
D22 MICROLECTRIC METER SOCKETS


BS2 Series
200 A 600 V; oversize enclosure

Diagrams
5 7⁄16 in.
Trade size
knockout
1
⁄2 in. Trade size
Trade size 2 places knockout
knockout 1, 1 1⁄4 , 1 1⁄2 , 2, 2 1⁄2
Trade size 1 1⁄4 , 1 1⁄2 , and 3 in.
knockout 2 and 2 1⁄2 in. 2 places
1
⁄2 in. 3 places

17⁄8 in. 2 1⁄4 in. 4 3⁄16 in. 2 9 ⁄16 in.


5 3⁄8 in. 7
⁄8 in. 4 3⁄4 in. 1 3 ⁄16 in.
75⁄8 in. 1
⁄2 in. 9 7 ⁄8 in. 1
⁄2 in.
1
⁄4 in. KO
1
⁄4 in.
Typical bottom BC Bottom 3''

Trade size 2 ⁄8 in.


1

knockout
1, 1 1⁄4 , 1 1⁄2 , 2 and 2 3⁄16 in.
2 ⁄2 in. 2 places
1
BS2 SERIES & KIT D23


BS2 Series kit
200 A 600 V; oversize enclosure with PVC accessories

Product specifications • Supplied with screw type ring


• Conductor range: 6 AWG–250 kcmil • Weatherproof Type 3R enclosure
• Aluminum tunnel type connectors for both load • Primarily used in: Ontario only
and line sides Note: Supply from an underground network often requires use of stud
• For overhead, underground and combination type connector. Consult your local utility.

Approved for copper


or aluminum

Cat. no. Description Qty.


BS2-TCV-KIT2U Kit
BS2-TCV-KIT2U Kit – Meter socket with PVC accessories
Consists of
BS2-TCV 200 A meter socket 1
E943J 2 in. Terminal adaptor 1
E986J 2 in. LB access fitting 1
E995J 2 in. Meter offsets 2
E977JC 2 in. Clamps 2
UA9AJCB-CTN 2 in. Elbow 90° 1
CI1716 2 in. Nut 3
PH20 2 in. Hub 1

Diagrams

5 7⁄16 in.

Trade size
knockout
Trade size 1 1⁄4 , 1 1⁄2 ,
knockout 2 and 2 1⁄2 in.
1
⁄2 in. 3 places

17⁄8 in. 2 1⁄4 in.


5 3⁄8 in. 7
⁄8 in.
75⁄8 in. 1
⁄2 in.
1
⁄4 in. KO
Typical bottom

2 1⁄8 in.

2 3⁄16 in.
Trade size knockout
1, 1 1⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in.
2 places
D24 MICROLECTRIC METER SOCKETS


BS2-TCVFA
200 A, 120/240; single-phase service

Product specifications • Designed and manufactured in Canada


• Line #6 AWG to 350 kcmil, load 2 x #6–4/0 AWG • Primarily used in: All provinces
• Tunnel type connectors for both load and Manitoba Hydro approved for overhead only
line sides Application: When distance is a factor, larger conductors require larger
• For underground and above ground service connectors.

• Weatherproof Type 3R enclosure

Approved for copper


or aluminum

Dimensions (in.) Weight Each


Cat. no. Description H W D lb kg
BS2-TCVFA 4 Jaw
BS2-TCVFA Combination overhead and underground 277⁄16 12 57⁄16 14 6.3
200 A service

Diagrams

5 7⁄16 in.
1 1⁄32 in.

Trade size knockout


1 1⁄4 in., 1 1⁄2 in.,
Trade size 2 in., 2 1⁄2 in.
12 in. knockout 1⁄2 in. 3 places

1.475 in. 3.32 in.


2.5 in.
277⁄16 in.
2 1⁄4 in.
7
⁄8 in.

1 ⁄8 in.
7 5 3⁄8 in. 1
⁄4 in.
75⁄8 in. KO

2 1⁄8 in.
10.61 in.

Trade size knockout


1 in., 1 1⁄4 in., 1 1⁄2 in.,
2 in., 2 1⁄2 in.
2 places

5 7⁄8 in.
B S 2 -TC V FA , B S 2 L S E R I E S D25


BS2L Series
200 A 600 V; oversize enclosure lay-in lug

Product specifications • For overhead, underground and combination


• Same as BS2 series with the exception that lay-in overhead/underground
type connectors are provided • Supplied with screw type ring
• Conductor range: 6 AWG–250 kcmil • Weatherproof Type 3R enclosure
• Aluminum lay-in type connectors for both load • Primarily used in: B.C., Ont.
and line sides

Approved for copper


or aluminum

Dimensions (in.) Weight each


Cat. no. Description H W D lb kg
BS2L-TV 4 Jaw
BS2L-TV 200 A underground with lay-in lugs 171⁄8 12 57⁄16 16 7.2
BS2L-INTV 200 A underground with lay in lug, insolated neutral 17 ⁄81
12 57⁄16 16 7.2
BS2L-TCV 200 A over/under combination with lay-in lugs 171⁄8 12 57⁄16 16 7.2
BS2L-INTCV 200 A overhead-underground with lay in lugs, 171⁄8 12 57⁄16 16 7.2
isolated neutral
BS2L-TCVGN 200 A underground-overhead with lay in lugs comes 171⁄8 12 57⁄16 16 7.2
with ground lug on neutral
BS2L-TCVBCR 200 A over/under combination with lay-in lugs 171⁄8 12 57⁄16 16 7.2
(BC Hydro)
Factory-installed accessories
Include: -5 5th jaw standard capacity
-6 5 jaw full capacity, 6 o’clock position
th

-9 5th jaw full capacity, 9 o’clock position


-IN Insulated neutral

Diagrams
5 7⁄16 in.

Trade size
knockout
Trade size knockout 1
⁄2 in., 2 places
1 1⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in. Trade size knockout
Trade size
3 places 1, 1 1⁄4 , 1 1⁄2 , 2, 2 1⁄2 and 3 in.
knockout
2 places
1
⁄2 in.

17⁄8 in. 2 1⁄4 in. 4 3⁄16 in. 2 9⁄16 in.


5 3⁄8 in. 7
⁄8 in. 4 3⁄4 in. 1 3⁄16 in.
75⁄8 in. 1
⁄2 in. 9 7⁄8 in.
1
⁄2 in.
1
⁄4 in.
1
⁄4 in.

Typical bottom BC HYDRO bottom 2 1⁄8 in.

2 3⁄16 in.

Trade size knockout


1, 1 1⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in.
2 places
D26 MICROLECTRIC METER SOCKETS


BS2M Series
200 A 600 V; oversize enclosure, subfeed on load side

Product specifications • Dual lug subfeed for load side


• Conductor range: line: 6 AWG–250 kcmil, • Supplied with screw type ring
load: 12–1/0 AWG • Weatherproof Type 3R enclosure
• Aluminum tunnel type connector for line side • Primarily used in: All provinces
• For overhead service only

Approved for copper


or aluminum

Dimensions (in.) Weight each


Cat. no. Description H W D lb kg

4 Jaw
BS2M-V BS2M-V Overhead, hub opening 171⁄8 12 57⁄16 15 6.8

Diagrams
5 7⁄16 in.

Trade size
knockout
Trade size 1 ⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in.
1

knockout 3 places
1
⁄2 in.

17⁄8 in. 2 1⁄4 in.


5 3⁄8 in. 7
⁄8 in.
75⁄8 in. 1
⁄2 in.

Trade size
Bottom knockout
1
⁄4 in.

2 1⁄8 in.

2 3⁄16 in.

Trade size knockout


1 1⁄4 , 1 1⁄2 , 2 and 2 1⁄2 in.
2 places
BS2M SERIES, MO2 SERIESS D27


MO2 Series
200 A 600 V; underground only

Product specifications • Aluminum tunnel type connectors for load side,


• Conductor range: line: single 1⁄2 in. studs to 1
⁄2 in. studs on line side
accommodate compression lugs 350 kcmil max. • Supplied with screw type ring
(supplied by utility), load: 6 AWG–250 kcmil • Weatherproof Type 3R enclosure
• For underground service only • Primarily used in: Sask., Man., Ont., Que.

Approved for copper


or aluminum

Dimensions (in.) Weight each


Cat. no. Description H W D lb kg
MO2-V 4 Jaw
MO2-V Underground 1⁄2 in. studs 191⁄8 12 5 9 ⁄16 18 8.1
MO2-INV Underground ½ in. stud 191⁄8 12 5 9 ⁄16 18 8.1
comes with isolated neutral
MO2-VO Underground 1⁄2 in. studs for Ontario 191⁄8 12 5 9 ⁄16 18 8.1
MO2-INVO Underground ½ in. stud for ontario 19 ⁄8
1
12 5 9 ⁄16 18 8.1
comes with isolated neutral
Factory-installed accessories
Include: -M 2/0 AWG subfeed on load side

Diagrams

9 5⁄16 in.

Trade size Trade size


Trade size
knockout knockout
knockout
1 1⁄4 , 1 1⁄2 , 2 1, 1 1⁄4 , 1 1⁄2 , 2, 2 1⁄2 and 3 in.
7
⁄8 in.
⁄8 in.
7
and 2 1⁄2 in. 2 places
2 places
3 places

19 1⁄8 in.

17⁄8 in. 4 3⁄16 in.


5 3⁄8 in.
4 3⁄4 in.
7 ⁄8 in.
5
1
⁄4 in. 9 ⁄8 in.
7 1
⁄4 in.
MO2-VO bottom
MO2-V bottom
2 in.

2 5⁄16 in.
D28 MICROLECTRIC METER SOCKETS


MO2 Series Kit
200 A 600 V; underground only with PVC accessories

Product specifications • Aluminum tunnel type connectors for load side


• Conductor range: line: single 1⁄2 in. studs to • Supplied with screw type ring
accommodate compression lugs (supplied • Weatherproof Type 3R enclosure
by utility), load: 6 AWG–250 kcmil • Primarily used in: Ontario only
• For underground service only

Approved for copper


or aluminum

Cat. no. Description Qty.


MO2-VO-KIT2U Kit
MO2-VO-KIT2U Kit – Meter socket with PVC accessories
Consists of
MO2-VO 200 A meter socket 1
CI1716 2 in. Locknut 3
E943J 2 in. Male adaptor 1
E977JC 2 in. Pipe strap 2
E986J 2 in. Conduit bodies – LB type 1
E995J 2 in. Meter offsets 2
UA9AJCB-UPC 2 in. 90 o Elbow 1

Diagrams

5 9⁄16 in.

Trade size
knockout
1, 1 ⁄4 , 1 1⁄2 , 2 and 2 1⁄2
1
7
⁄8 in.
3 places

19 1⁄8 in.

17⁄8 in.
5 3⁄8 in.

75⁄8 in. ⁄4 in.


1

2 in.
MO2-VO bottom

2 5⁄16 in.
MO2 SERIES KIT D29


MO2 Series kit
200 A 600 V; underground only with PVC accessories

Product specifications • Aluminum tunnel type connectors for load


• Conductor range: line: single 1⁄2 in. studs to side, 1⁄2 in. studs on line side
accommodate compression lugs (supplied • Supplied with screw type ring
by utility), load: 6 AWG–250 kcmil • Weatherproof Type 3R enclosure
• For underground service only • Primarily used in: Quebec only

Approved for copper


or aluminum

Cat. no. Description Qty. Cat. no. Description Qty.


Kit Kit
MO2-V-KIT1-1/4U Meter socket with PVC accessories MO2-V-KIT2U Meter socket with PVC accessories
Consists of Consists of
MO2-V 200 A Meter socket 1 MO2-V 200 A Meter socket 1

CE942RL 3 in. PVC/DB2 adaptor 1 CE942RL 3 in. PVC/DB2 adaptor 1

CI1710 11⁄4 in. Nut 2 CI1716 2 in. Nut 2

CI1724 3 in. Nut 1 CI1724 3 in. Nut 1

CI-DUCT-1 Duct seal 1 CI-DUCT-1 Duct seal 1

E943G 1 ⁄4 in. Male adaptor


1
2 E943J 2 in. Male adaptor 2
MO2-V-KIT1-1/4U E943L 3 in. Male adaptor 1
E943L 3 in. Male adaptor 1
E945L 3 in. Expansion fitting 1 E945L 3 in. Expansion fitting 1

E977GC 11⁄4 in. Pipe strap 1 E977JC 2 in. Pipe strap 1

E977LC-CAR 3 in. Pipe strap 1 E977LC-CAR 3 in. Pipe strap 1

E986G 11⁄4 in. Conduit bodies – 1 E986J 2 in. Conduit bodies – 1


LB type LB type

UA9AGCB-UPC 11⁄4 in. 90 o Elbow 1 UA9AJCB-UPC 2 in. 90 o Elbow 1

Diagrams

5 9⁄16 in.

Trade size Trade size


knockout knockout
7
⁄8 in. 1, 1 ⁄4 , 1 1⁄2 , 2, 2 1⁄2 and 3 in.
1

2 places 2 places

19 1⁄8 in.

4 3⁄16 in.
2 in.
4 3⁄4 in.

9 7⁄8 in. 1
⁄4 in.
2 5⁄16 in. MO2-V bottom