MV Disconnector Disconnector MV
Primary distribution Primary distribution
Distribution Distribution
transformer transformer
MV MV
SF6 RMU SF6 RMU
Distribution
generation
Long list of potential environmental and health Reconstruction of primary substations with regard to
risks associated with the use of obsolete replacement of switchgears and metering devices requires
equipment which is not suited for Smart Grid special attention from utilities, since existing equipment
are often nearing the end of their intended service life. This
applications. requires an effective strategy of replacing or upgrading existing
equipment with modern analogues, which will drastically
expand observability and controllability of the distribution
network – the part of power system with the greatest losses.
3
Smart Grid Solution
Distribution automation
2 Distribution automation with Recloser and REZIP sectionalizer
TELSCADA Maintenance free Tavrida recloser with complete • Complete measuring system (4x current
Dispatch center measurement system, advanced protection and channels, 6x voltage channels, direction)
embedded RTU: • Power-quality monitoring
• Embedded auxiliary power supply system
• Advanced IED protection (ABR, Synchro-check,
Fault locator)
• Innovative REZIP sectionalizer algorithm
TELSCADA TELSCADA • Communication: IEC 104/DNP3.0/Modbus
Server and local workstation Server and local workstation
Remote communication
IEC101/103/104
3
DNP 3.0
IEC 61850 Substation automation solutions with Mile switchgear or Retrofit
Maintenance free MILE type air insulated Advanced flexible and reliable RTU
MV MV switchgear for primary and secondary systems for substation automation:
Primary distribution REZIP Primary distribution distribution network with Tavrida vacuum • IED protection
Recloser circuit breaker. • Communication: IEC 101/IEC 103/
sectionalizer
IEC 104/DNP3.0/IEC 61850 (option)
Alternative solution: innovative plug and • Measuring (voltage, current, direction)
play switchgear Retrofit solution with • Power-quality monitoring
Main substation Main substation Tavrida vacuum circuit breaker. • Auxiliary power supply system
Distribution Distribution
transformer MV transformer
MV
3
Secondary
iRMU
distribution
4
The Energomera automated electric energy management and metering system is designed for measurement of electric energy and power by
automatically collecting meter readings, monitoring commercial and technical losses, including through analysis of balance consumption groups,
consumer load control. Automatic readings collection and control of metering devices is carried out via communication channels: PLC, RF, GSM/
GPRS/3G/Cat.NB, LoRa WAN, Ethernet, RS485.
Distribution
generation • early detection of electric energy theft as well as technical losses
Recloser due to balance control (in homes, transformer substations,
1 2 4
enterprises);
• prompt response to attempts of unauthorized tampering with
metering devices due to the functions of unsolicited reports;
• ability to control the consumer load (ability to disconnect
defaulters remotely);
• automation of subscriber billing.
GENERAL DESCRIPTION
The Energomera AMI System includes:
• CE208 S7, CE208 C4 and CE209 single-phase multi-tariff
CE308 C36 CE208 S7 CE209 C3 metering devices;
1 Distribution automation with SCELL switchgear and iRMU • CE308 S34 and CE308 C36 three-phase multi-tariff direct
connection metering devices;
FEATURES AND ADVANTAGES • CE308 S31 three-phase multi-tariff semi-indirect and indirect
New alternative to SF6 gas-insulated RMU. Maintenance SCELL iRMU: • organization of reliable and operational electric energy metering connection metering devices;
free compact SCELL type air insulated switchgear for • IED protection for each subscriber; • DCU CE805M data concentrator unit;
secondary distribution network with Tavrida vacuum • Customized RTU system depending on the application • providing (using broadcast synchronization) a universal time system • AdminTools software for configuring elements of the system.
circuit breaker. • Communication: IEC 104/DNP3.0/IEC 61850 (option) for organizing multi-tariff metering; Automatic readings collection and control of metering devices is
• Measuring (voltage, current, direction) • reduction of energy losses due to control, analysis and elimination carried out via communication channels: PLC, RF, GSM/GPRS/3G/
SCELL Switchgear: • Power-quality monitoring of irrational use of electric energy in common facilities; Cat.NB, LoRa WAN, Ethernet, RS485.
• TLF/IED protection • Auxiliary power supply system
• Remote control up to 5 panels
• Communication: IEC 104/DNP3.0
4 5
Smart Grid Solution
TELSCADA is optimized for controlling Tavrida and Energomera equipment in electric energy distribution and metering systems. However, The advanced distribution automation and management functions
it is compatible with any specialized computing device supporting standard industrial interfaces which allow utilities to integrate all of its reduce outage time from hours to minutes without the involvement Minimizing outage time
equipment into one system. of field personnel.
Because of high data transmission speed, TELSCADA provides collection and representation the following data from all the meters at the
same time:
• Voltage frequency The possibility of remote reprogramming of metering devices as well
• Phase currents as setting consumption limits allow to quickly optimize the system Maintenance cost reduction
• Phase voltages without involving additional personnel.
• Angles between current and voltage per phases
• Linear voltages
• Power factor per phases and in total
• Active power per phases and in total Redundant architecture enhances availability and increases the
reliability of the system. User-friendly and functional interface
Maximum reliability
• Reactive power per phases and in total and ease of use
guarantees safe and error-free operation.
• Apparent power per phases and in total
The company receives the following advantages by implementing a complex SCADA solution based on Tavrida and Energomera equipment:
• Loss reduction
Developed to meet industrial standards for data commu-nications
• Reliability increasing
such as such IEC 60870-5-101/103/104 and cyber security standards Standards compliance
• Improvement of SAIDI, SAIFI indexes such as IEC 62351.
• Bringing the voltage level to standard values network company operating costs reduction through new business processes implementation
• Power grid safety and ease of operation improvement
6 7
Smart Grid Solution
The event logging module allows users to easily access and process data
about power consumption, faults, switching operations and various historical
events that create a solid base for accurate system analysis.
8 9
Smart Grid Solution
Main features
Standard solutions for simple integration with the TELSCADA system
Maximum performance through the special TELSCADA design developed to provide full control over all the recloser functions
Parallel communication channel to access and configure the recloser settings
Possibility to use multiple data channels for communications
Secure data channel protects information against unauthorized access
RUT955 specification
Ethernet Hardware
• IEEE 802.3, IEEE 802.3u • High performance 560MHz CPU with 128MB DDR2 memory
• 3 x LAN 10/100 Mbps Ethernet ports • 2 pin industrial DC power socket
• 1 x WAN 10/100 Mbps Ethernet port • 4 pin industrial socket for 2/4 wire RS485
• Supports auto MDI/MDIX • 10 pin industrial socket for inputs/outputs
WiFi • DB9 socket for full-featured RS232
• IEEE 802.11b/g/n, 2.4 GHz, 2x2 MIMO • USB A socket for external devices
Rec15/25 Automatic Circuit Recloser: • 2 x SMA for LTE, 1 x SMA for GPS, 2 x RP-SMA for WiFi
• 64/128-bit WEP, WPA, WPA2, WPA&WPA2, EAP-PEAP
• SSID stealth mode and access control based on MAC address • Indication LEDs
• State of the art Outdoor Switching Module
Electrical, Mechanical & Environmental Software
• Sophisticated control and protection for Smart Grids
• OpenVPN, IPsec, GRE, L2TP, PPTP, PPPoE, VRRP
• Dimensions (H x W x D) 80 mm x 106 mm x 46 mm
• x6 combined current and voltage sensors built-in • Backup WAN, dynamic DNS, SNMP trap monitoring
• Weight 265 g
• Event logging
• Maintenance free • Power supply 9-30 VDC
• Firewall, web filter
• Power consumption <7W
• Lightest weight • RS232/485 serial console, RS232/485 over IP
• Operating temperature -40 °C to 75 °C
• SMS/e-mail control and indication
• Plug & Play design • Operating humidity 10 % to 90 % non-condensing
• Firmware update via WebUI, configuration backup
• 55,000 installations worldwide
10 11
Smart Grid Solution
Meters
The Energomera automated electric energy management and metering system is designed for measurement of electric
Value
energy and power by automatically collecting meter readings, monitoring commercial and technical losses, including through Parameters
СЕ208 S7 CE308 S34 CE308 S31 CE208 C4 CE308 C36 CE209 С3
analysis of balance consumption groups, consumer load control and billing for the electric energy used by interacting with
1-phase 3-phase 3-phase 1-phase 3-phase 1-phase
billing systems. Connection circuit
2 wire 4 wire 3/4 wire 2 wire 4 wire 2 wire
The world's first
for board for board for board three-phase «DIN
Case type SPLIT SPLIT
mounting mounting mounting rail mountable»
SPLIT meter
172…265 V or
Single-phase multi-tariff Three-phase multi-tariff Supply voltage range 127…265 V 172…265 V
35…66 V
127…265 V 172…265 V 184…276 V
DCU СЕ805М
Features and benefits:
Parameters Value
• organization of reliable and timely accounting of electricity for each subscriber;
• providing (with the use of broadcast synchronization) a single time system, for the organization of multi-tariff accounting; Supply voltage range 90-264 V
• educing energy losses by monitoring, analyzing and eliminating wasteful use of electricity in public areas; Interfaces for:
• timely detection of theft of electricity, as well as technical losses due to the control of balances (at home, transformer • data collection from meters RS485 2 channels, RF or PLC
substation, enterprise);
• collected DCU data reading and for DCU configuration Wi-Fi, USB-device, GSM/GPRS/3G
• prompt response to attempts of unauthorized interference in the operation of metering devices due to the functions (2 SIM), Ethernet, RS485
of initiative messages;
• communication with portable storage devices Micro-SD, USB-host
• the ability to manage the load of consumers (the ability to remotely disable non-payers);
Types of meters for data collection support DLMS, IEC 62056-21 protocols
• automation of subscriber account statements.
Number of supported meters, max 4000
Quality and reliability: Number of input discrete (output telecontrol) channels 4 (2)
• The production meets the international standard ISO 9000 and is certified by TuV Temperature range -40…+65 °C
• The meters comply with international standards IEC 62052-11, IEC 62053-21, IEC 62053-23, IEC 62055, IEC 62056.
• USPD meets international standards of IEC 60529:2013, IEC 61000-6-5:2001, IEC 60950-1-2014, IEC 61010-1:2001.
• The products are certified by: KEMA international laboratory; DLMS. Channel-forming equipment for power line data
transmission is certified by the G3 PLC Alliance.
12 13
Smart Grid Solution
Tulenergo
Russia, Tula
Orenburgenergo
Russia, Orenburg
Tavrida Electric is the leading supplier of reclosers in Egypt. For the past 5
years over 400 reclosers have been successfully integrated in the TELSCADA
system. The key-customers are the secondary distrubution companies: North
and South Delta, El-Beheira, Alexandria, Middle and Upper Egypt.
14 15