Buklet TELSCADA

The document discusses challenges with the existing distribution network and proposes solutions using smart grid technologies. Specifically, it notes that the existing system lacks monitoring and remote control capabilities. It also faces risks from obsolete equipment, long outages, and high maintenance costs. The document proposes distribution automation using reclosers, sectionalizers, and substation automation to address these issues and enable integration of renewable energy in an efficient way.

Uploaded by

Ivan Jeremic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views9 pages

Buklet TELSCADA

The document discusses challenges with the existing distribution network and proposes solutions using smart grid technologies. Specifically, it notes that the existing system lacks monitoring and remote control capabilities. It also faces risks from obsolete equipment, long outages, and high maintenance costs. The document proposes distribution automation using reclosers, sectionalizers, and substation automation to address these issues and enable integration of renewable energy in an efficient way.

Uploaded by

Ivan Jeremic
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Smart Grid Solution

Distribution automation challenges

No monitoring and remote control over the distribution


network without the use of SCADA.

MV Disconnector Disconnector MV
Primary distribution Primary distribution

Main substation Main substation

Distribution Distribution
transformer transformer
MV MV
SF6 RMU SF6 RMU

Distribution
generation

Long list of potential environmental and health Reconstruction of primary substations with regard to
risks associated with the use of obsolete replacement of switchgears and metering devices requires
equipment which is not suited for Smart Grid special attention from utilities, since existing equipment
are often nearing the end of their intended service life. This
applications. requires an effective strategy of replacing or upgrading existing
equipment with modern analogues, which will drastically
expand observability and controllability of the distribution
network – the part of power system with the greatest losses.

Manually operated disconnectors are not equipped with any


automation capabilities and require maintenance personnel
to restore power after long outage periods.
Long-time power outages and high maintenance
cost of the existing non-automated system. A controller can take current readings from outdated electric
energy meters only locally, which entails a large amount
of associated costs. Great complications are also caused
by the need to limit/disconnect the consumer or make changes
to their tariff schedule.

Old generation non-extensible RMU can no longer meet


feeder automaton requirements Use of environmentally
High technical and commercial losses in the and health hazardous SF6 is associated with the need for:
• Continuous monitoring of SF6 degradation;
electric energy transmission and distribution, • Special regulations for recycling of hazardous waste.
as well as high costs for personnel transfer to
collect meter readings. Global shift toward renewable energy is already underway.
How to handle integration of distributed energy resources in
the most efficient way?

3
Smart Grid Solution

Distribution automation
2 Distribution automation with Recloser and REZIP sectionalizer

TELSCADA Maintenance free Tavrida recloser with complete • Complete measuring system (4x current
Dispatch center measurement system, advanced protection and channels, 6x voltage channels, direction)
embedded RTU: • Power-quality monitoring
• Embedded auxiliary power supply system
• Advanced IED protection (ABR, Synchro-check,
Fault locator)
• Innovative REZIP sectionalizer algorithm
TELSCADA TELSCADA • Communication: IEC 104/DNP3.0/Modbus
Server and local workstation Server and local workstation

Remote communication
IEC101/103/104

3
DNP 3.0
IEC 61850 Substation automation solutions with Mile switchgear or Retrofit

Maintenance free MILE type air insulated Advanced flexible and reliable RTU
MV MV switchgear for primary and secondary systems for substation automation:
Primary distribution REZIP Primary distribution distribution network with Tavrida vacuum • IED protection
Recloser circuit breaker. • Communication: IEC 101/IEC 103/
sectionalizer
IEC 104/DNP3.0/IEC 61850 (option)
Alternative solution: innovative plug and • Measuring (voltage, current, direction)
play switchgear Retrofit solution with • Power-quality monitoring
Main substation Main substation Tavrida vacuum circuit breaker. • Auxiliary power supply system

Distribution Distribution
transformer MV transformer
MV

3
Secondary
iRMU
distribution

4
The Energomera automated electric energy management and metering system is designed for measurement of electric energy and power by
automatically collecting meter readings, monitoring commercial and technical losses, including through analysis of balance consumption groups,
consumer load control. Automatic readings collection and control of metering devices is carried out via communication channels: PLC, RF, GSM/
GPRS/3G/Cat.NB, LoRa WAN, Ethernet, RS485.

Distribution
generation • early detection of electric energy theft as well as technical losses
Recloser due to balance control (in homes, transformer substations,

1 2 4
enterprises);
• prompt response to attempts of unauthorized tampering with
metering devices due to the functions of unsolicited reports;
• ability to control the consumer load (ability to disconnect
defaulters remotely);
• automation of subscriber billing.

GENERAL DESCRIPTION
The Energomera AMI System includes:
• CE208 S7, CE208 C4 and CE209 single-phase multi-tariff
CE308 C36 CE208 S7 CE209 C3 metering devices;

1 Distribution automation with SCELL switchgear and iRMU • CE308 S34 and CE308 C36 three-phase multi-tariff direct
connection metering devices;
FEATURES AND ADVANTAGES • CE308 S31 three-phase multi-tariff semi-indirect and indirect
New alternative to SF6 gas-insulated RMU. Maintenance SCELL iRMU: • organization of reliable and operational electric energy metering connection metering devices;
free compact SCELL type air insulated switchgear for • IED protection for each subscriber; • DCU CE805M data concentrator unit;
secondary distribution network with Tavrida vacuum • Customized RTU system depending on the application • providing (using broadcast synchronization) a universal time system • AdminTools software for configuring elements of the system.
circuit breaker. • Communication: IEC 104/DNP3.0/IEC 61850 (option) for organizing multi-tariff metering; Automatic readings collection and control of metering devices is
• Measuring (voltage, current, direction) • reduction of energy losses due to control, analysis and elimination carried out via communication channels: PLC, RF, GSM/GPRS/3G/
SCELL Switchgear: • Power-quality monitoring of irrational use of electric energy in common facilities; Cat.NB, LoRa WAN, Ethernet, RS485.
• TLF/IED protection • Auxiliary power supply system
• Remote control up to 5 panels
• Communication: IEC 104/DNP3.0

4 5
Smart Grid Solution

Presentation TELSCADA provides continuous monitoring of the network to detect


any failures, abnormal situations or to collect data on supplied and Reducing maintenance
consumed electric energy, which reduces the need for scheduled and costs
emergency maintenance work.
The TELSCADA system is designed for real-time monitoring and control of primary and secondary equipment in electric energy distribution
and metering systems. It provides all the functionality that is expected from a SCADA system, allowing the operator to safely and effectively
interact with the protection and management equipment, achieving maximum network efficiency and reliability.

TELSCADA is optimized for controlling Tavrida and Energomera equipment in electric energy distribution and metering systems. However, The advanced distribution automation and management functions
it is compatible with any specialized computing device supporting standard industrial interfaces which allow utilities to integrate all of its reduce outage time from hours to minutes without the involvement Minimizing outage time
equipment into one system. of field personnel.

Because of high data transmission speed, TELSCADA provides collection and representation the following data from all the meters at the
same time:
• Voltage frequency The possibility of remote reprogramming of metering devices as well
• Phase currents as setting consumption limits allow to quickly optimize the system Maintenance cost reduction
• Phase voltages without involving additional personnel.
• Angles between current and voltage per phases
• Linear voltages
• Power factor per phases and in total
• Active power per phases and in total Redundant architecture enhances availability and increases the
reliability of the system. User-friendly and functional interface
Maximum reliability
• Reactive power per phases and in total and ease of use
guarantees safe and error-free operation.
• Apparent power per phases and in total

The company receives the following advantages by implementing a complex SCADA solution based on Tavrida and Energomera equipment:
• Loss reduction
Developed to meet industrial standards for data commu-nications
• Reliability increasing
such as such IEC 60870-5-101/103/104 and cyber security standards Standards compliance
• Improvement of SAIDI, SAIFI indexes such as IEC 62351.
• Bringing the voltage level to standard values network company operating costs reduction through new business processes implementation
• Power grid safety and ease of operation improvement

6 7
Smart Grid Solution

Features Technical summary


Platform and architecture
TELSCADA is based on the open source Enlogic software platform and is
EnLogic open-source software for industrial applications
intended for embedded controllers widely used in grid automation.
It supports Linux, WinCE, Win32 / 64, and eCos platforms. The system Supported platforms: WinCE, Win32/64, eCos
implements a client-server architecture that allows you to create a multi-
Microsoft SQL Server and Firebird SQL-based database management system
server automation system designed to support a large number of control points.
At the same time, SCADA is highly scalable and can be used for deployment of High performance and reliability
low-level single systems up to full-fledged distributed monitoring, metering System self-supervision
and control systems. This means that data collection servers, databases, and
operator workstations can be installed on either one or several computers, Multi-scale solutions for grid automation
allowing the implementation of multi-scale grid system automation projects. Communication interfaces
Supported communication protocols: IEC 60870-5-101/103/104, Modbus RTU/TCP, DNP3.0 RTU/TCP
Supported open interfaces: OPC DA 2 and OPC UA
HMI (Human Machine Interface) – the core component designed to display the
Standard libraries for simple integration with widely-used IEDs
power distribution system with real-time data acquisition.
The interface allows operators to remotely monitor and control equipment Energy distribution monitoring, metering and control
and to process historical data.
Real-time monitoring and metering and full control over remote objects
Flexible and user-configurable HMI allows you to create extensible simulate
charts with thousands of objects. Standard visualization features such Managing outages and reconfiguring the network
as dynamic coloring provide operators with quick access to information
Graphic display with dynamic coloring and visualization of disturbing objects
about power and non-power sections of the network, power consumption/
generation, load profile data for each customer, and equipment status (closed/ System performance analysis
open/grounded – for circuit breakers, load break switches, disconnectors; Advanced data logging and refinement
relay status, tamper events, network parameters – for metering devices ).
All disturbing objects are highlighted for clear identification and quick Power-quality monitoring: THD, active/reactive/apparent power and energy, power factor, etc.
response. Dynamic coloring combined with full object control ensures safe Extensive reporting facilities: event profile, measurements, outage reports
and correct operation of the system.
Network security
Database (DB) – Microsoft SQL Server and Firebird SQL-based database Encryption and security protocols such as VPN (OpenVPN, IPsec, GRE, L2TP, PPTP), DNP3.0 secure authentication
management system is designed to archive thousands of values and records
over long time periods in an accurate and easily accessible way. The ability to Malware security protection
export data from a SQL Server database to a Microsoft Excel worksheet, HTML Role-based user authorization and access control
or other text formats allows a user to create various customized reports. The
Event logging and reporting
backup and restore features provide an essential safeguard for protecting
critical data stored in the database.

Data Acquisition Server (DAS) is used to connect remote objects to


TELSCADA. It coordinates and sends commands to the connected object to
adjust parameters and provides the time synchronization feature which allows
accurate time-tagging of all events. Collected data is stored in the database.

The event logging module allows users to easily access and process data
about power consumption, faults, switching operations and various historical
events that create a solid base for accurate system analysis.

Alarm module is designed to signal any failures, malfunctions or warnings


which demand the operator’s attention to abnormal system conditions
requiring action.

Power monitoring – optional module for real-time power monitoring which


ensures that the system fulfils the requirements set for power quality. All
the important information (THD, active/reactive/apparent power and energy,
power factor and others) is stored in the database and can be easily converted
into the meaningful report.

8 9
Smart Grid Solution

TELSCADA application example TECHNICAL SOLUTION


Tavrida Electric offers utilities to easily integrate all existing and new reclosers with the
TELSCADA system, which continuously monitors the system and processes commands executed
by the operator.
GRID AUTOMATION WITH RECLOSERS
Remote control and monitoring functions are implemented over HSUPA/HSDPA/UMTS/EDGE/
Tavrida Electric Rec series reclosers provide protection from various faults, including: short circuits, earth faults, high impedance earth
GPRS network using IEC 60870-5-104 or DNP3.0 communication protocol. The recloser uses
faults, broken wires, islanding, incorrect tap changer operations, network overload and over- or under-generation. the embedded RTU and highly reliable and secure LTE router RUT955 specially developed
Embedded IED with the RTU (Remote Terminal Unit), protection and metering functions makes the recloser the perfect solution for grid for industrial applications. The RUT955 delivers high performance, mission-critical wireless
automation projects. Tavrida Electric reclosers allow utilities to implement Smart Grid philosophies and deploy advanced self-healing FDIR communication and GPS coordination. The dual SIM feature provides redundant cellular
(Fault Detection, Isolation and Restoration) systems. connection in a critical situation. The external LTE/GPS/WIFI outdoor antenna attached to the
recloser cubicle provides the best signal and possibility to remotely configure the router and
recloser settings over the wireless network.

Main features
Standard solutions for simple integration with the TELSCADA system
Maximum performance through the special TELSCADA design developed to provide full control over all the recloser functions
Parallel communication channel to access and configure the recloser settings
Possibility to use multiple data channels for communications
Secure data channel protects information against unauthorized access

RUT955 specification
Ethernet Hardware
• IEEE 802.3, IEEE 802.3u • High performance 560MHz CPU with 128MB DDR2 memory
• 3 x LAN 10/100 Mbps Ethernet ports • 2 pin industrial DC power socket
• 1 x WAN 10/100 Mbps Ethernet port • 4 pin industrial socket for 2/4 wire RS485
• Supports auto MDI/MDIX • 10 pin industrial socket for inputs/outputs
WiFi • DB9 socket for full-featured RS232
• IEEE 802.11b/g/n, 2.4 GHz, 2x2 MIMO • USB A socket for external devices
Rec15/25 Automatic Circuit Recloser: • 2 x SMA for LTE, 1 x SMA for GPS, 2 x RP-SMA for WiFi
• 64/128-bit WEP, WPA, WPA2, WPA&WPA2, EAP-PEAP
• SSID stealth mode and access control based on MAC address • Indication LEDs
• State of the art Outdoor Switching Module
Electrical, Mechanical & Environmental Software
• Sophisticated control and protection for Smart Grids
• OpenVPN, IPsec, GRE, L2TP, PPTP, PPPoE, VRRP
• Dimensions (H x W x D) 80 mm x 106 mm x 46 mm
• x6 combined current and voltage sensors built-in • Backup WAN, dynamic DNS, SNMP trap monitoring
• Weight 265 g
• Event logging
• Maintenance free • Power supply 9-30 VDC
• Firewall, web filter
• Power consumption <7W
• Lightest weight • RS232/485 serial console, RS232/485 over IP
• Operating temperature -40 °C to 75 °C
• SMS/e-mail control and indication
• Plug & Play design • Operating humidity 10 % to 90 % non-condensing
• Firmware update via WebUI, configuration backup
• 55,000 installations worldwide

Platform and architecture Rec15 Rec25


Rated voltage (Ur) 15.5 kV 27 kV
Rated continuous current (Ir) 630 A 630 A
Rated short-circuit breaking current (Isc) 16 kA 12.5 kA
Rated frequency (fr) 50/60 Hz
Operating cycles, rated current (CO-cycles) 30 000
Operating cycles, breaking current (CO-cycles) 200
Closing time, not more than 50 ms
Opening time, not more than 25 ms
Rated operating sequence O-0.1s-CO-1s-CO-1s-CO
Outdoor Switching Module weight 68 kg 72 kg
Service life 30 years

10 11
Smart Grid Solution

AMI System TECHNICAL SPECIFICATION

Meters
The Energomera automated electric energy management and metering system is designed for measurement of electric
Value
energy and power by automatically collecting meter readings, monitoring commercial and technical losses, including through Parameters
СЕ208 S7 CE308 S34 CE308 S31 CE208 C4 CE308 C36 CE209 С3
analysis of balance consumption groups, consumer load control and billing for the electric energy used by interacting with
1-phase 3-phase 3-phase 1-phase 3-phase 1-phase
billing systems. Connection circuit
2 wire 4 wire 3/4 wire 2 wire 4 wire 2 wire
The world's first
for board for board for board three-phase «DIN
Case type SPLIT SPLIT
mounting mounting mounting rail mountable»
SPLIT meter

CE208 DLMS CE308 DLMS Active/reactive energy


accuracy class
1/2 1/2
0.5S/0.5
or 0,2S/0.5
1/2 1/2 1/2

172…265 V or
Single-phase multi-tariff Three-phase multi-tariff Supply voltage range 127…265 V 172…265 V
35…66 V
127…265 V 172…265 V 184…276 V

electricity meters electricity meters Base (maximum)


5(80) A 5(100) A 5(10) A 5(80) A 5(100) A 5(80) A
current
Number of tariffs 8
Load Profile Storage
Up to 128 days for 6 parameters
Depth
Depth of storage of
energy indicators and 40 months
Maximum Demand
Power quality control In accordance with EN 50160:2010
Communication
Optoport and PLC or RF or GSM/GPRS/3G/Cat.NB or LoRa or Ethernet or RS485
interfaces
CE208 DLMS CE308 DLMS Communication
IEC 62056-21 or DLMS/HDLC
protocol
Single-phase multi-tariff Three-phase multi-tariff Control relay
Load up to 265 V Load up to 265 V External device Load up to 265 V Load up to 265 V Load up to 276 V
100 A 120 A up to 265 V 1 A 100 A 120 A 100 A
electricity meters electricity meters
Temperature range -40…+70 °С
1. С3 - the narrowest case in the industry, which provides the maximum group placement of meters in a cabinet.
Technical features 2. Maximum moisture protection due to the «upturned bucket» design.
3. Support of GOST IEC 62056-21 and DLMS/COSEM data exchange protocols or «Smart Metering» protocol.

DCU СЕ805М
Features and benefits:
Parameters Value
• organization of reliable and timely accounting of electricity for each subscriber;
• providing (with the use of broadcast synchronization) a single time system, for the organization of multi-tariff accounting; Supply voltage range 90-264 V

• educing energy losses by monitoring, analyzing and eliminating wasteful use of electricity in public areas; Interfaces for:

• timely detection of theft of electricity, as well as technical losses due to the control of balances (at home, transformer • data collection from meters RS485 2 channels, RF or PLC
substation, enterprise);
• collected DCU data reading and for DCU configuration Wi-Fi, USB-device, GSM/GPRS/3G
• prompt response to attempts of unauthorized interference in the operation of metering devices due to the functions (2 SIM), Ethernet, RS485
of initiative messages;
• communication with portable storage devices Micro-SD, USB-host
• the ability to manage the load of consumers (the ability to remotely disable non-payers);
Types of meters for data collection support DLMS, IEC 62056-21 protocols
• automation of subscriber account statements.
Number of supported meters, max 4000

Quality and reliability: Number of input discrete (output telecontrol) channels 4 (2)
• The production meets the international standard ISO 9000 and is certified by TuV Temperature range -40…+65 °C
• The meters comply with international standards IEC 62052-11, IEC 62053-21, IEC 62053-23, IEC 62055, IEC 62056.
• USPD meets international standards of IEC 60529:2013, IEC 61000-6-5:2001, IEC 60950-1-2014, IEC 61010-1:2001.
• The products are certified by: KEMA international laboratory; DLMS. Channel-forming equipment for power line data
transmission is certified by the G3 PLC Alliance.

12 13
Smart Grid Solution

References Reference summary

Experience and knowledge of complex grid automation

More than 10 turnkey large-scale SCADA government-backed projects


Yantarenergo
More than 50 small-scale SCADA projects
Russia, Kaliningrad
Over 2.5 thousand of objects integrated in SCADA
JSC Energomera, Tavrida electric and a consortium of partner companies
have implemented a distributed automation system for the 15 kV network 15 years of experience in the successful implementation of AMI Systems
in Mamonovsky and Bagrationovsky districts. Overhead line equipment and
substation switchgears integrated with the SCADA system provides control More than 4,000,000 metering points in the framework of the creation of AMI Systems
over the power distribution network. As a result of the project, utilities
reported a reduction in operating costs and power outages from 5 hours to
just 50 minutes. In the end, the Kaliningrad experience laid the Foundation
for a government-supported digital distribution model that will soon be
implemented in other regions of Russia.

Tulenergo
Russia, Tula

During the implementation of the project of an automated system for electricity


metering in Tula, more than 34,000 electricity meters were delivered. The
efficient operation of the system has reduced the SAIDI indicator by 53%, and
the SAIFI indicators by 73%, which has provided savings of more than 3 million
dollars in year.

Orenburgenergo
Russia, Orenburg

Tavrida Electric implemented a turn-key automation project which included


the supply of 100 reclosers integrated with the SCADA system in Orenburg
district. The total cost of SCADA deployment was less than 15% of the cost
of primary equipment.

The Egyptian Electricity Holding Company


Egypt

Tavrida Electric is the leading supplier of reclosers in Egypt. For the past 5
years over 400 reclosers have been successfully integrated in the TELSCADA
system. The key-customers are the secondary distrubution companies: North
and South Delta, El-Beheira, Alexandria, Middle and Upper Egypt.