0% found this document useful (0 votes)
1K views1 page

ST Nerf 30 Septic Tank Details ST Nerf 30

The document appears to be a technical drawing showing dimensions for a reinforced concrete cover slab and septic tank system. It includes dimensions and notes for a 200mm thick reinforced concrete cover slab, a 3850mm x 3850mm septic tank, and a soak way pit. Dimensions are provided for elements including the cover slab, septic tank, soak way pit, and relevant technical notes.

Uploaded by

mhazarath murari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

ST Nerf 30 Septic Tank Details ST Nerf 30

The document appears to be a technical drawing showing dimensions for a reinforced concrete cover slab and septic tank system. It includes dimensions and notes for a 200mm thick reinforced concrete cover slab, a 3850mm x 3850mm septic tank, and a soak way pit. Dimensions are provided for elements including the cover slab, septic tank, soak way pit, and relevant technical notes.

Uploaded by

mhazarath murari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

200mm THICK REINFORCED CONCRETE

COVER SLAB
3850
3850 NOTES:
225 1975 225 1200 225 700
1975 1200 225 THE ORIENTATION OF SEPTIC TANK AND SOAK WAY PIT
225 +0.050 225 225 +0.050 225 FGL
1500
±0.000 225 1500 225
SHOULD REFER TO SITE LAYOUT
T.O,S T.O,S
-0.100 -0.100

225
200

200

225
TWL
50 min TWL
INLET 150Ø T20Ø
150Ø
(TOP & BOTTOM 50
BOTH LAYERS) x
di
T20Ø a
(TOP & BOTTOM
BOTH LAYERS)

2350
1900

1500
75mm(TYP)
VARIES

150Ø

50mm
(TYP)
1500

WATER STOP
100 L
WATER STOP

225

B
OPENING

225
250
250

600x600 MANHOLE
OPENING WITH HEAVY
25mm PROTECTION SCREED 600 600 DUTY COVER (TYP.)
4mm MEMBRANE 300THK ,20 GRADE BLACK B
TYP.BELOW
GRADE SLAB
TORCH APPLIED
50mm BLINDING
SECTION - A AGGREGATE
WF1 LONG T20Ø 50 x dia
SCALE -1:25 (TOP & BOTTOM
SUBGRADE COMPACTED TO
95% M.D.D
NOTE:- ALL INTERNAL AND EXTERNAL WALL OPENING SHOULD BE STRUCTURAL G.A. PLAN AT COVER SLAB ( SEPTIC BOTH LAYERS)
INLINE WITH MEP AND SITE CONDITIONS, SHOP DRAWINGS
SHALL BE PROVIDED FOR ENGINEER'S REVIEW. TANK )
SCALE -1:25
TYPICAL REINFORCEMENT DETAILS
3850 200mm THICK REINFORCED AROUND OPENING IN FLOOR
100 225 1975 225 1200 225 100 CONCRETE COVER SLAB
2350 SLAB/WALL HAVING LARGER
200 225 1500 225 200 DIMENSIONS OF MORE THAN
225 1900 225
600 600 500mm.
NOTE : FOR OPENINGS HAVING LARGER DIMENSIONS LESS
225 100

THAN 500mm, THE ABOVE STEEL BARS SHALL BE


REPLACED BY 16Ø AND 300mm SHORTER BARS.

200
600
C1 C1
WF1 TWL

45
225

Ø
(M
IN
200THK INFILLED BLOCKWALLS

)
LAID ON HORIZONTAL MORTAR
SOAKPIT 2T16 BARS (EF)
BED WITH 20mm WIDE OPEN VERTICAL 45Ø(MIN)
PAINTING NITOCOAT JOINTS BACKED CLEAN
225
EPW-100
BITUPAINT 1000MICRON
2550

1900

WF1

WF1
MAIN BARS : 4T16
A LINKS : T8-200

VARIES
BITUMEN PAINT C1
PROTECTIVE COATING

1500
GEOTEXTILE 1000GUAGE +POLYTHENE SHEET+
PLYWOOD PROTECTION
WF1

C1 C1 100
100
100 225

20 GRADE BLACK
AGGREGATE

TYPICAL REINFORCEMENT DETAIL

250
B VOIDS IN CONCRETE BLOCKS TO BE
FILLED WITH CONCRETE AND AROUND CIRCULAR OPENINGS
REINFORCED WITH 1 NO. T16 VERTICAL
BAR POSITIONED ON CENTER AND
STRUCTURAL G.A. PLAN AT BASE SLAB PASSING THROUGH ALL BLOCKWORK

( SEPTIC TANK )
COURSES. SECTION - B
SCALE -1:25 SCALE -1:25

T12-200EW (T&B) T10-200EW (T&B) T12-200EW (T&B)

0 26.07.2021 ISSUED FOR CONSTRUCTION HM

KINGDOM OF BAHRAIN
ELECTRICITY AND WATER AUTHORITY
T12-200(V)EF PLANNING & STUDIES
1500

T12-200(V)EF T12-200(V)EF T12-200(V)EF COL. C-1 COL. C-1


T12-200(H)EF
INTERNATIONAL
T12-200(H)EF T12-200(H)EF T12-200(H)EF Consulting Engineers to the Energy Sector
P.O. Box 5922, Manama, Kingdom of Bahrain
Tel: (+973) 1770 8118 Fax: (+973) 1770 0115

ISMAIL KHONJI ASSOCIATES


250

220/66 KV TRANSMISSION DEVELOPMENT


4T12
T12-200EW (T&B) WF1 WF1 600 T12-200EW (T&B)
T12-200

SEPTIC TANK REINFORCEMENT DETAILS FOR SECTION - A SEPTIC TANK REINFORCEMENT DETAILS FOR SECTION - B
SUBSTATION CIVIL WORK

66 kV CITY TYPE SUBSTATION


AT NEW EAST RIFA'A
SEPTIC TANK AND SOAK PIT DETAILS
STRUCTURAL G.A PLAN , SECTIONS & REINF'T DETAILS
HM IYP MAY'21 AS SHOWN

Rev
HM TMS 1154 ST-NERF-30